MLRE224 24-In Built-In Compact Refrigerators
Owner’s Manual
MLRE224 24-In Built-In Compact Refrigerators
WELCOME
Welcome to the Marvel Experience
Thank you for choosing our quality American-built product to add to your
home. We are thrilled to welcome you to our growing community of Marvel owners
who trust in our products and our support.
The information in this guide is intended to help you install and maintain
your new Marvel undercounter model to protect and prolong its lifetime. We
encourage you to contact our Technical Support team at (616) 754-5601 with any
questions.
Got a Marvelous Design?
We would love to see how your Marvel product looks in its new home. Send us
photos at marketing@marvelrefrigera-tion.com, and we might feature your Marvel home design on
our website and social media!
Thank you again for investing in Marvel for your home!
Warranty Registration
It is important you send in your warranty registration card immediately after
taking delivery of your appliance or you can register online at
www.marvelrefrigeration.com.
The following information will be required when registering your appliance.
Service Number
Serial Number
Date of Purchase
Dealer’s name and address
Online registration available at
www.marvelrefrigeration.com
The service number and serial number can be found on the serial plate which is
located inside the cabinet on the left side near the top. See figure below.
Tip: Click on any section below to jump directly there
IMPORTANT SAFETY INSTRUCTIONS
Warnings and safety instructions appearing in this guide are not meant to
cover all possible conditions and situations that may occur. Common sense,
caution, and care must be exercised when installing, maintaining, or
operating this appliance.
Recognize Safety Symbols, Words, and Labels.
CAUTION
NOTE
CAUTION-Hazards or unsafe practices which could result in personal injury
or property / product damage.
WARNING
State of California Proposition 65 Warning:
This product contains one or more chemicals known to the State of California
to cause cancer.
WARNING
WARNING – You can be killed or seriously injured if you do not follow
these instructions.
NOTE-Important information to help assure a problem free installation and
operation.
WARNING
State of California Proposition 65 Warning: This product contains one or more
chemicals known to the State of California to cause birth defects or other
reproductive harm.
WARNING
WARNING - This unit contains R600a (Isobutane) which is a flammable
hydrocarbon. It is safe for regular use. Do not use sharp objects to expedite
defrosting. Do not damage refrigerant circuit.
UNPACKING YOUR APPLIANCE
WARNING
EXCESSIVE WEIGHT HAZARD
Use two or more people to move product. Failure to do so can result in
personal injury.
Remove Interior Packaging
Your appliance has been packed for shipment with all parts that could be
damaged by movement securely fastened. Remove internal packing materials and
any tape holding internal components in place. The owners manual is shipped
inside the product in a plastic bag along with the warranty registration card,
and other accessory items.
Important
Keep your carton and packaging until your appliance has been thoroughly
inspected and found to be in good condition. If there is damage, the packaging
will be needed as proof of damage in transit. Afterwards please dispose of
all items responsibly.
WARNING
WARNING – Dispose of the plastic bags which can be a suffocation hazard.
Note to Customer
This merchandise was carefully packed and thoroughly inspected before leaving
our plant. Responsibility for its safe delivery was assumed by the retailer
upon acceptance
of the shipment. Claims for loss or damage sustained in transit must be made
to the retailer.
NOTE
DO NOT RETURN DAMAGED MERCHANDISE TO THE MANUFACTURER – FILE THE CLAIM WITH
THE RETAILER.
CAUTION
If the appliance was shipped, handled, or stored in other than an upright
position for any period of time, allow the appliance to sit upright for a
period of at least 24 hours before plugging in.
This will assure oil returns to the compressor.
Plugging the appliance in immediately may cause damage to internal parts.
WARNING
WARNING – Help Prevent Tragedies
Child entrapment and suffocation are not problems of the past. Junked or
abandoned refrigerators are still dangerous – even if they sit out for “just a
few hours”.
If you are getting rid of your old refrigerator, please follow the
instructions below to help prevent accidents.
Before you throw away your old refrigerator or freezer:
- Take off the doors or remove the drawers.
- Leave the shelves in place so children may not easily climb inside.
ELECTRICAL
WARNING
Electrical Shock Hazard
- Do not use an extension cord with this appliance. They can be hazardous and can degrade product performance.
- This appliance should not, under any circumstances, be installed to an un-grounded electrical supply.
- Do not remove the grounding prong from the power cord. (See Figure 2).
- Do not use an adapter. (See Figure 3).
- Do not splash or spray water from a hose on the appliance. Doing so may cause an electrical shock, which may result in severe injury or death.
Electrical Connection
A grounded 115 volt, 15 amp dedicated circuit is required.
This product is factory equipped with a power supply cord that has a three-
pronged, grounded plug. It must be plugged into a mating grounding type
receptacle in ccordance with the National Electrical Code and applicable local
codes and ordinances (see Figure 4). If the circuit does not have a grounding
type receptacle, it is the responsibility and obligation of the customer to
provide the proper power supply.
The third ground prong should not, under any circumstances, be cut or removed.
NOTE
Ground Fault Circuit Interrupters (GFCI) are prone to nuisance tripping which
will cause the appliance to shut down.
GFCI’s are generally not used on circuits with power equipment that must run
unattended for long periods of time, unless required to meet local building
codes and ordinances.
INSTALLING THE ANTI TIP DEVICE
WARNING
- ALL APPLIANCES CAN TIP RESULTING IN INJURY.
- INSTALL THE ANTI-TIP BRACKET PACKED WITH THE APPLIANCE.
- FOLLOW THE INSTRUCTIONS BELOW
Anti-Tip Device
** WARNING
If your beverage center is not located under a counter top (free standing),
you must use an anti-tip device installed as per these instructions. If the
beverage center is removed from its location for any reason, make sure that
the device is properly engaged with the anti-tip bracket when you push the
beverage center back into the original location. If the device is not properly
engaged, there is a risk of the beverage center tipping over, with the
potential for property damage or personal injury.
NOTE
If installing on a concrete floor, concrete fasteners are required, (not
included with the anti-tip kit).
CAUTION
Any finished flooring should be protected with appropriate material to avoid
damage when moving the unit.
Floor Mount Installation**
The anti-tip bracket is to be located on the floor in the left or right rear
corner of the wine cellar as shown in Figure 14.
Step by step instructions for locating the position of the bracket:
- Decide where you want to place the beverage center. Slide it into place, being careful not to damage the floor, leaving 1″ (2.5 cm) of clearance from the rear wall to allow room for the anti-tip bracket.
- Raise the rear leveling legs approximately 1⁄4″ (6 mm) to allow engagement with the anti-tip bracket. Level the unit by adjusting all the leveling legs as required. Turning the leveling leg counterclockwise will raise the unit and clockwise will lower the unit.
- Make sure the beverage center is in the desired location, then mark on the floor the rear and side corner of the cabinet where the anti-tip bracket will be installed. If the installation does not allow marking the rear corner of the cabinet, then make temporary lines on the floor marking the front corner of the cabinet, excluding the door. Slide the beverage center out of the way. From the temporary line extend the sidewall line back 21 1⁄2″ (54.6 cm) as shown in Figure 15.
- Align the anti-tip bracket to the marks on the floor so the side of the bracket lines up with the side of the cabinet mark, and the “V” notches on the anti-tip bracket line up with the end of the 21 1⁄2″ (54.6 cm) line (Rear of cabinet line).
- Fasten the anti-tip bracket to the floor using the supplied screw. (See Figure 15).
- Slide the cabinet back into position, making sure the rear cabinet leveling leg slides under the anti-tip bracket engaging the slot.
INSTALLING THE ANTI TIP DEVICE
NOTE
When the floor mounted anti-tip bracket is used the minimum adjusted height of
the cabinet is increased by 3⁄8″ (9 mm).
INTERIOR ADJUSTMENTS
CAUTION
Never try to remove a loaded shelf, remove everything from the shelf before
removing. Use both hands when removing the shelf.
To remove a shelf:
Extend the shelf out of the cabinet until it stops.
Unload the shelf (see Figure 33).
Depress the locking tabs on both sides of the shelf and pull the shelf straight out (see Figure 29a). When the shelf is removed, push the extended cabinet mounted shelf exten- sions back into the cabinet.
To re-install a shelf:
Pull out the cabinet mounted shelf extensions to assist the engagement with
the wire rack shelf. Insert the wire rack side track into the cabinet mounted
shelf extensions on both sides.
Push the wire rack completely into the cabinet to engage the locking tabs.
Pull the shelf out, (unloaded), to verify the wire rack is locked into the
side rails. If the wire rack falls out, the locking tabs are not engaged;
repeat the installation.
Load the shelf as required.
CARE AND CLEANING
Front Grille
Be sure that nothing obstructs the required air flow openings in front of the
cabinet.
At least once or twice a year, brush or vacuum lint and dirt from the front
grille area (see page 8).
**CAUTION**
SHOCK HAZARD: Disconnect electrical power from the appliance before
cleaning with soap and water.
Cabinet
The painted cabinet can be washed with either a mild soap and water and
thoroughly rinsed with clear water. NEVER use abrasive scouring cleaners.
Interior
Wash interior compartment with mild soap and water. Do NOT use an abrasive
cleaner, solvent, polish cleaner or undiluted detergent.
Care of Appliance
- Avoid leaning on the door, you may bend the door hinges or tip the appliance.
- Exercise caution when sweeping, vacuuming or mopping near the front of the appliance. Damage to the grille can occur.
- Periodically clean the interior of the appliance as needed.
- Periodically check and/or clean the front grille as needed.
In the Event of a Power Failure
If a power failure occurs, try to correct it as soon as possible. Minimize the
number of door openings while the power is off so as not to adversely affect
the appliance’s temperature.
Light assembly replacement
All models use an LED to illuminate the interior of the appliance. This
component is very reliable, but should it fail, contact a qualified service
technician for replacement of the LED.
The following suggestions will minimize the cost of operating your refrigeration appliance.
- Do not install your appliance next to a hot appliance (cooker, dishwasher, etc.), heating air duct, or other heat sources.
- Install product out of direct sunlight.
- Ensure the front grille vents at front of appliance beneath door are not obstructed and kept clean to allow ventilation for the refrigeration system to expel heat.
- Plug your appliance into a dedicated power circuit. (Not shared with other appliances).
- When initially loading your new product, or whenever large quantities of warm contents are placed within refrigerated storage compartment, minimize door openings for the next 12 hours to allow contents to pull down to compartment set temperature.
- Maintaining a relatively full storage compartment will require less appliance run time than an empty compartment.
- Ensure door closing is not obstructed by contents stored in your appliance.
- Allow hot items to reach room temperature before placing in product.
- Minimize door openings and duration of door openings.
- Use the warmest temperature control set temperature that meets your personal preference and provides the proper storage for your stored contents.
- When on vacation or away from home for extended pe riods, set the appliance to warmest acceptable tem perature for the stored contents.
- Set the control to the “off” position if cleaning the appliance requires the door to be open for an extended period of time.
- For wine storage products:
When serving temperatures are not required, return the compartment(s) set temperature to the ideal red and white wine long term storage tem perature of 13°C /55°F.
STAINLESS STEEL MAINTENANCE
Background
Stainless steel does not stain. corrode, or rust as easily as ordinary steel,
but it is not stain or corrosion proof. Stain-less steels can discolor or
corrode if not maintained prop-erty.
Stainless steels differ from ordinary carbon steels by the amount of chromium
present. It is this chromium that provides an invisible protective film on the
surface called chrome-oxide. This protective chrome-oxide film on the surface
can be damaged or contaminated, which may result in discoloration, staining,
or corrosion of the base metal.
Care & Cleaning
Routine cleaning of the stainless steel surfaces will serve to greatly extend
the life of your product by removing contami-nants. This is especially
important in coastal areas which can expose the stainless to severe
contaminants such as halide salts, (sodium chloride).
It is strongly recommended to periodically inspect and thor-oughly clean
crevices, weld points, under gaskets, rivets, bolt heads, and any locations
where small amounts of liquid could collect, become stagnant, and concentrate
contami-nates. Additionally, any mounting hardware that is showing signs of
corrosion should be replaced.
Frequency of cleaning will depend upon the installation location,
environmental, and usage conditions.
Choosing a Cleaning Product
The choice of a proper cleaning product is ultimately that of the consumer,
and there are many products from which to choose. Depending upon the type of
cleaning and the degree of contamination, some products are better than
others.
Typically the most effective and efficient means for routine cleaning of most
stainless steel products is to give the sur-faces a brisk rubbing with a soft
cloth soaked in warm water and a gentle detergent, or mild mixture of ammonia.
Rub-bing should, to the extent possible, follow the polish lines of the steel,
and always Insure thorough rinsing after cleaning.
Although some products are called “stainless steel clean-ers,” some may
contain abrasives which could scratch the surface. (compromising the
protective chrome-mide film). and some many contain chlorine bleach which will
dull, tarnish or discolor the surface If not completely removed. After the
stainless surfaces have been thoroughly cleaned. a good quality car wax may be
applied to help maintain the finish.
NOTE
Stainless steel products should never be installed, or stored in close
proximity to chlorine chemicals.
Whichever cleaning product you chose, it should be used in strict accordance
with the instructions of the cleaner manufacturer.
ENERGY SAVING TIPS
The following suggestions will minimize the cost of operating your refrigeration appliance.
- Do not install your appliance next to a hot appliance (cooker, dishwasher, etc.), heating air duct, or other heat sources.
- Install product out of direct sunlight.
- Ensure the front grille vents at front of appliance beneath door are not obstructed and kept clean to allow ventilation for the refrigeration system to expel heat.
- Plug your appliance into a dedicated power circuit. (Not shared with other appliances).
- When initially loading your new product, or whenever large quantities of warm contents are placed within refrigerated storage compartment, minimize door openings for the next 12 hours to allow contents to pull down to compartment set temperature.
- Maintaining a relatively full storage compartment will require less appliance run time than an empty compartment.
- Ensure door closing is not obstructed by contents stored in your appliance.
- Allow hot items to reach room temperature before placing in product.
- Minimize door openings and duration of door openings.
- Use the warmest temperature control set temperature that meets your personal preference and provides the proper storage for your stored contents.
- When on vacation or away from home for extended pe riods, set the appliance to warmest acceptable tem perature for the stored contents.
- Set the control to the “off” position if cleaning the appliance requires the door to be open for an extended period of time.
- For wine storage products:
When serving temperatures are not required, return the compartment(s) set temperature to the ideal red and white wine long term storage tem perature of 13°C /55°F.
EXTENDED NON-USE
Vacation/Holiday, Prolonged Shutdown
The following steps are recommended for periods of extended non-use:
- Remove all consumable content from the unit.
- Disconnect the power cord from its outlet/socket and leave it disconnected until the unit is returned to service.
- If ice is on the evaporator, allow ice to thaw naturally.
- Clean and dry the interior of the unit. Ensure all water has been removed from the unit.
- The door must remain open to prevent formation of mold and mildew. Open door a minimum of 2″ (50 mm) to provide the necessary ventilation.
Winterization
If the unit will be exposed to temperatures of 40° F (5° C) or less, the steps
above must be followed.
For questions regarding winterization, please call Marvel at (616) 754-5601.
CAUTION
Damage caused by freezing temperatures is not covered by the warranty.
OBTAINING SERVICE
If Service is Required:
- If the product is within the first year warranty period please contact your dealer or call Marvel Customer Service at 616.754.5601 for directions on how to obtain warranty coverage in your area.
- If the product is outside the first year warranty period, Marvel Customer Service can provide recommendations of service centers in your area. A listing of authorized service centers is also available at www.marvelrefrigeration.com under the service and support section.
- In all correspondence regarding service, be sure to give the service number, serial number, and proof of purchase.
- Try to have information or description of nature of the problem, how long the appliance has been running, the room temperature, and any additional information that may be helpful in quickly solving the problem.
- Table “B” is provided for recording pertinent information regarding your product for future reference.
For Your Records|
---|---
Date of Purchase|
Dealer’s name|
Dealer’s Address|
Dealer’s City|
Dealer’s State|
Dealer’s Zip Code|
Appliance Serial Number|
Appliance Service Number|
Date Warranty Card Sent (Must|
be within 10 days of purchase).|
Table B
Product Liability
Field service technicians are authorized to make an initial assessment in the
event of reported damages. If there are any questions about the process
involved, the technician should call Marvel for further explanation.
While inspecting for defects or installation issues, photos should be taken to
document any damages or issues found.
During the assessment, if the service technician is able to find the source of
the damage and it can be resolved by replacement of a part, the servicer is
authorized to replace the part in question. The part that caused the damage
must be returned to Marvel in its entirety. The part must be clearly labeled
with the serial number of the unit it was removed from, the date, and the
servicer who removed the part.
If the service technician determines the damage is the result of installation
issues (water connection/drain, etc.), the consumer would be notified and the
issues shall be resolved at the direction of the consumer.
If damage is evident and the service technician is unable to find the source,
Marvel must be contacted at 616.754.5601 for further direction.
1260 E. Van Deinse St• Greenville, MI 48838
T: +1.616.754.5601
Website: www.marvelrefrigeration.com
The original refrigeration experts since 1892.
Warranty Claims
The following information defines the parameters for filing a warranty claim:
- Valid serial number needed
- Valid model number needed
- Claims must be submitted online at www.marvelservice.com
- 60 day submittal deadline from date of completed service
- Only one repair or unit per warranty claim
- Part order numbers will be required when submitting for warranty labor Units must be registered prior to warranty submittal. Customers may register at www.marvelrefrigeration.com. A proof of purchase is required. We also accept the following information to update warranty:
- New construction occupancy documents
- Closing paperwork
- Final billing – Remodel
Warranty parts will be shipped at no charge after Marvel confirms warranty
status. Please provide the model, serial number, part number and part
description. Some parts will
require color or voltage information.
Ordering Replacement Parts
Parts may be ordered online at partsformarvel.com
Or contact:
www.marvelrefrigeration.com (Servicers
choose “Login” for service account).
Phone Number: (616) 754-5601
NOTICE
Use only genuine Marvel replacement parts. The use of non-Marvel parts can
reduce performance, damage the unit, and void the warranty.
Warranty parts will be shipped at no charge after Marvel confirms warranty
status. Please provide the model, serial number, part number and part
description. Some parts will
require color or voltage information.
Marvel requires the return of original parts, we will inform you when the
parts order is taken. This requirement will be noted on your packing list. A
prepaid shipping label will be emailed to you. Please enclose a copy of the
parts packing list and be sure the model and serial numbers are legible on the
paperwork. Tag the part with the reported
defect.
Customers and non-authorized servicers may order non warranty parts at
www.partsformarvel.com. Authorized servicers
with a servicer login may order non-warranty
parts at www.marvelrefrigeration.com.
R-600A Specifications & Handling
WARNING
Flammability warnings for a pure-iso-butane refrigerant.
Gloves and Eye Protection must be used.
R-600a is considered non-toxic, but is flammable when mixed with air.
Keep a dry powder type fire extinguisher in the work area.
R-600a is heavier than air, do not allow any leakage/migration to low areas
such as basements and stairs.
Never use a torch on a fully charged refrigeration system.
Never substitute Marvel OEM replacement parts or methods of construction.
R-600a must be stored and transported in approved containers.
Only skilled and well trained service technicians permitted to service R-600a
equipped products.
All tools and equipment must be approved for use with R-600a refrigerant.
Local, state and federal laws, standards must be observed along with proper
certification and licensing.
Ventilation is required during servicing.
No conversions to R-600a from any other refrigerants. OEM R-600a equipped unit
only.
Service area must be free of ignition sources.
No smoking is allowed in the service area.
All replacement electrical components must be OEM and installed properly
(sealed and covered).
If the evaporator is cold prior to service, it must be thawed prior to
service.
When using a vacuum pump, start pump before opening refrigeration system.
Vacuum pump and recovery equipment should be at least 10 feet from the work
area.
It is recommended that a simple LPG gas detector is on site during service.
Ensure that all R-600a is removed from the system prior to brazing any part of
the sealed system.
Only a clean, dry leak free system should be charged with R-600a.
R-600A SPECIFICATIONS/LABELING
R-600a equipped products are labeled (both the unit and the compressor).
R-600a is colorless and odorless.
R-600a is considered non-toxic, but is flammable when mixed with air.
Do not remove or alter any R-600a labeling on the product.
Use only a refrigerant grade R-600a from a properly labeled container.
RECOVERING/RECLAIMING R-600A
(R-600a has been exempted from recovery/reclaiming requirements by the US EPA)
Recovery/Reclaiming equipment must be approved for use with R-600a.
Ensure the evaporator is at room temperature prior to recovery /reclaiming
R-600a.
Use a common piercing pliers or piercing valve to remove
R-600a from the compressor process tube. (Note: Piercing devices must not be
lelt on the system and must be replaced with a Schrader type valve.)
Evacuate/reclaim via the piecing pliers to ensure the system is empty of R-600a before any system work is performed.
The recovery cylinder must be evacuated (no air inside) prior to accepting
R-600a.
The recovery cylinder must not be filled more than 45% safe fill level and
refrigerants must not be mixed.
The recovery cylinder must be clearly marked with R600a and Flammable Warning
labels.
Ensure proper ventilation during recovery/reclaiming of R600a.
Start vacuum pump/recovery pump prior to piercing the compressor process tube.
Follow recovery/reclaim OEM instructions for the specific equipment used.
SYSTEM REPAIR
Ensure no residual R-600a refrigerant is left within the system prior to
repair (simple venting is not sufficient).
Evacuate and charge with dry nitrogen for leak checks.
Repair leaks or replace system parts as required.
When re-brazing, the system must be purged with dry nitrogen and at least one
access point open to the atmosphere.
When re-brazing, proper ventilation is required along with constant monitoring
for the presence of R600a refrigerant.
The filter dryer must be replaced any time the sealed system is serviced.
No system should be open to the atmosphere for longer than 15 minutes to avoid
moisture migration into the system components.
LEAK DETECTION
After removal of the R-600a, the unit can be charged with dry nitrogen or
helium.
Electronic leak detection or soap solution can be used to check for
nitrogen/helium leaks.
Never use a halide torch or lighted match to check the system for leaks at any
time.
The high side of the refrigeration system (compressor discharge to outlet of
drier) must be leak tested with the compressor running.
The low side of the refrigeration system (evaporator, compressor and suction line) must be leak tested with the compressor off (equalized pressure).
RECHARGING
No air is ever to be allowed inside the refrigeration system (R-600a
refrigerant or dry nitrogen only). Never use a torch on a fully charged
refrigeration system.
Install a Schrader Type access port on the compressor process stub.
Evacuate the system to 100 microns prior to charging.
Weigh in the R-600a charge using a refrigerant scale. (run compressor an extra
two minutes to clear the charging hoses).
Seal the Schrader Type access port, a proper cap and seal must be used to
close the system.
SUMMARY
Safely handling R-600a requires proper procedures and training.
R-600a approved service tools must be used.
R-600a labeling must not be removed or altered.
Proper ventilation during service is required.
Never apply a torch to a charged R-600a refrigeration system.
Use OEM replacement service parts and do not alter the construction of the
unit.
System Diagnosis Guide
REGRIGERATION SYSTEM DIAGNOSIS GUIDE
System Condition| Suction Pressure| Suction Line| Compressor
Discharge| Condenser| Capillary Tube| Evaporator|
Wattage
---|---|---|---|---|---|---|---
Normal| Normal| Slightly
below room temperature| Very hot| Very hot| Warm| Cold| Normal
Overcharge| Higher than normal| Very cold may frost heavily| Slightly
warm to hot| Hot to warm| Cool| Cold| Higher than normal
Undercharge| Lower than normal| Warm-
near room temperature| Hot| Warm| Warm| Extremely
cold near
inlet – Outlet below room temperature| Lower than normal
Partial Restriction| Somewhat
lower than normal vacuum| Warm-
near room temperature| Very hot| Top passes warm –
Lower
passes cool (near room temperature) due to liquid| Room temperature (cool) or
colder| Extremely
cold near
inlet – Outlet below room temperature backing up| Lower than normal
Complete Restriction| In deep
vacuum| Room temperature (cool)| Room temperature (cool)| Room temperature
(cool)| Room temperature (cool)| No refrigeration| Lower than normal
No Gas| 0 PSIG to 25″| Room temperature (cool)| Cool to hot| Room
temperature (cool)| Room temperature (cool)| No refrigeration| Lower than
normal
Compressor Specifications
DANGER
Electrocution can cause death or serious injury. Burns from hot or cold
surfaces can cause serious injury. Take precautions when servicing this unit.
Disconnect the power source.
Do not stand in standing water when working around electrical appliances.
Make sure the surfaces you touch are not hot or frozen.
Do not touch a bare circuit board unless you are wearing an anti-static wrist
strap that is grounded to an electrical ground or grounded water pipe.
Handle circuit boards carefully and avoid touching components.
| EMX2OCLC
---|---
REFRIGERANT| R600A
VOLTAGE| 115 VAC
FREQUENCY| 60 Hz
START WINDING| 7 Ohm at 77° F
RUN WINDING| 13 Ohm at 77° F
RUN TO START| 20 Ohm at 77° F
LRA| 3.7 A
FLA| 0.55 A
STARTING DEVICE| Run Cq)12VF 250V P2
OVERLOAD| OLP 4TM302KFBYY5
*All resistance readings are ± 10%
HOUSEHOLD PRODUCT WARRANTY
Marvel Refrigeration (Marvel) Limited Warranty
ONE YEAR LIMITED PARTS & LABOR WARRANTY
For one year from the date of original purchase, this warranty covers all
parts and labor to repair or replace any part of the product that proves to be
defective in materials or workmanship. For products installed and used for
normal residential use, material cosmetic defects are included in this
warranty, with coverage limited to 60 days from the date of original purchase.
All service provided by Marvel under the above warranty must be performed by a
Marvel factory authorized servicer, unless otherwise specified by Marvel.
Service provided during normal business hours.
TWO YEAR LIMITED PARTS & LABOR WARRANTY (MARVEL PROFESSIONAL PRODUCTS)
For two years from the date of original purchase, this warranty covers all
parts and labor to repair or replace any part of the product that proves to be
defective in materials or workmanship. For products installed and used for
normal residential use, material cosmetic defects are included in this
warranty, with coverage limited to 60 days from the date of original purchase.
All service provided by Marvel under the above warranty must be performed by a
Marvel factory authorized servicer, unless otherwise specified by Marvel.
Service provided during normal business hours.
AVAILABLE THIRD YEAR LIMITED WARRANTY (MARVEL PROFESSIONAL PRODUCTS)
For designated Marvel Professional product, Marvel offers a one year extension
of the two year warranty coverage from the date of purchase, free of charge.
To take advantage of this third year warranty, you must register your product
with Marvel within 60 days from the date of purchase at
marvelrefrigeration.com and provide proof of purchase.
LIMITED FIVE YEAR SEALED SYSTEM WARRANTY
For five years from the date of original purchase, Marvel will repair or
replace the following parts, labor not included, that prove to be defective in
materials or workmanship: compressor, condenser, evaporator, drier, and all
connecting tubing. All service provided by Marvel under the above warranty
must be performed by a Marvel factory authorized servicer, unless otherwise
specified by Marvel. Service provided during normal business hours.
WARRANTY TERMS
These warranties apply only to products installed in any one of the fifty
states of the United States, the District of Columbia, or the ten provinces of
Canada. The warranties do not cover any parts or labor to correct any defect
caused by negligence, accident or improper use, maintenance, installation,
service, repair, acts of God, fire, flood or other
natural disasters. The product must be installed, operated, and maintained in
accordance with the Marvel User Guide.
The remedies described above for each warranty are the only ones that Marvel
will provide, either under these warranties or under any warranty arising by
operation of law. Marvel will not be responsible for any consequential or
incidental damages arising from the breach of these warranties or any other
warranty, whether express, implied, or statutory. Some states do not allow the
exclusion or limitation of incidental or consequential damages, so the above
limitation or exclusion may not apply to you. These warranties give you
specific legal rights, and you may also have other rights which vary from
state to state.
Any warranty that may be implied in connection with your purchase or use of
the product, including any warranty of merchantability or any warranty fit for
a particular purpose is limited to the duration of these warranties, and only
extends to five years in duration for the parts described in the section
related to the five year limited warranty
above. Some states do not allow limitations on how long an implied warranty
lasts, so the abov elimitations may not apply to you.
- The warranties only apply to the original purchaser and are non-transferable.
- These warranties cover products installed and used for normal residential use only.
- The warranties apply to units operated outside only if designed for outdoor use by model and serial number.
- Replacement water filters, light bulbs, and other consumable parts are not covered by these warranties.
- The start of Marvel’s obligation is limited to four years after the shipment date from Marvel.
- In-home instruction on how to use your product is not covered by these warranties.
- Food, beverage, and medicine loss are not covered by these warranties.
- If the product is located in an area where Marvel factory authorized service is not available, you may be responsible for a trip charge or you may be required to bring the product to a Marvel factory authorized service location at your own cost and expense.
- Units purchased after use as floor displays, and/or certified reconditioned units, are covered by the limited one year warranty only and no coverage is provided for cosmetic defects.
- Signal issues related to Wi-Fi connectivity are not covered by these warranties.
For parts and service assistance, or to find Marvel factory authorized service
near you, contact Marvel Refrigeration:
MarvelRefrigeration.com •
techsupport@MarvelRefrigeration.com
• +616.754.5601
1260 E. Van Deinse St., Greenville, MI 48838
www.marvelrefrigeration.com
Marvel Refrigeration
1260 E. Van Deinse St.
Greenville MI 48838
616.754.5601
41015887 Rev A
12/14/20
All specifications and product designs subject to change without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, replacements or compensation for previously purchased products.
References
- Premium Undercounter Products for Home & Outdoor | Marvel Refrigeration
- tion.com
- Premium Undercounter Products for Home & Outdoor | Marvel Refrigeration
- partsformarvel.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>