Marvel MORE224SS41A 24-Inch Steel Outdoor Built-In Refrigerator with Lock, Door Storage and Maxstore Bin Owner’s Manual
- October 27, 2023
- Marvel
Table of Contents
- Marvel MORE224SS41A 24-Inch Steel Outdoor Built-In Refrigerator with
- IMPORTANT SAFETY INSTRUCTIONS
- UNPACKING YOUR APPLIANCE
- ELECTRICAL
- INTERIOR ADJUSTMENTS
- CARE AND CLEANING
- STAINLESS STEEL MAINTENANCE
- ENERGY SAVING TIPS
- OBTAINING SERVICE
- Warranty Claims
- Specifications & Handling
- System Diagnosis Guide
- HOUSEHOLD PRODUCT WARRANTY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Marvel MORE224SS41A 24-Inch Steel Outdoor Built-In Refrigerator with
Lock, Door Storage and Max store Bin
Welcome to the Marvel Experience
Thank you for choosing our quality American-built product to add to your home.
We are thrilled to welcome you to our growing community of Marvel owners who
trust in our products and our support.
The information in this guide is intended to help you install and maintain
your new Marvel undercounter model to protect and prolong its lifetime. We
encourage you to contact our Technical Support team at (616) 754-5601 with any
questions.
Got a Marvelous Design?
We would love to see how your Marvel product looks in its new home. Send us
photos at
marketing@marvelrefrigeration.com,
and we might feature your Marvel home design on our website and social media!
Thank you again for investing in Marvel for your home!
Warranty Registration
It is important you send in your warranty registration card immediately after taking delivery of your appliance or you can register online at www.marvelrefrigeration.com.
The following information will be required when registering your appliance.
- Service Number
- Serial Number
- Date of Purchase
- Dealer’s name and address
The service number and serial number can be found on the serial plate which is located inside the cabinet on the left side near the top. See figure below.
IMPORTANT SAFETY INSTRUCTIONS
Important Safety Instructions
Warnings and safety instructions appearing in this guide are not meant to
cover all possible conditions and situa-tions that may occur. Common sense,
caution, and care must be exercised when installing, maintaining, or operat-
ing this appliance.
Recognize Safety Symbols, Words, and Labels.
- WARNING – You can be killed or seriously injured if you do not follow these instructions.
- CAUTION-Hazards or unsafe practices which could re-sult in personal injury or property / product damage.
- NOTE-Important information to help assure a problem free installation and operation.
- State of California Proposition 65 Warning: This product contains one or more chemicals known to the State of California to cause birth defects or other reproductive harm.
- State of California Proposition 65 Warning: This product contains one or more chemicals known to the State of California to cause cancer.
- WARNING - This unit contains R600a (Isobutane) which is a flammable hydrocarbon. It is safe for regular use. Do not use sharp objects to expedite defrosting. Do not damage refrigerant circuit.
UNPACKING YOUR APPLIANCE
EXCESSIVE WEIGHT HAZARD
Use two or more people to move product. Failure to do so can result in
personal injury.
Remove Interior Packaging
Your appliance has been packed for shipment with all parts that could be
damaged by movement securely fastened. Remove internal packing materials and
any tape holding in-ternal components in place. The owners manual is shipped
inside the product in a plastic bag along with the warranty registration card,
and other accessory items.
Important
Keep your carton and packaging until your appliance has been thoroughly
inspected and found to be in good condi-tion. If there is damage, the
packaging will be needed as proof of damage in transit. Afterwards please
dispose of all items responsibly.
WARNING – Dispose of the plastic bags which can be a suffocation hazard.
Note to Customer
This merchandise was carefully packed and thoroughly inspected before leaving
our plant. Responsibility for its safe delivery was assumed by the retailer
upon acceptance of the shipment. Claims for loss or damage sustained in
transit must be made to the retailer.
NOTE
DO NOT RETURN DAMAGED MERCHANDISE TO THE MANUFACTURER – FILE THE CLAIM WITH
THE RETAILER.
CAUTION
If the appliance was shipped, handled, or stored in other than an upright
position for any period of time, allow the ap-pliance to sit upright for a
period of at least 24 hours before plugging in. This will assure oil returns
to the compressor. Plugging the appliance in immediately may cause damage to
internal parts.
WARNING
Help Prevent Tragedies
Child entrapment and suffocation are not problems of the past. Junked or
abandoned refrigerators are still dangerous – even if they sit out for “just a
few hours”. If you are getting rid of your old refrigerator, please fol-low
the instructions below to help prevent accidents. Before you throw away your
old refrigerator or freezer:
- Take off the doors or remove the drawers.
- Leave the shelves in place so children may not easily climb inside.
ELECTRICAL
Electrical Shock Hazard
WARNING
- Do not use an extension cord with this appliance. They can be hazardous and can degrade product performance.
- This appliance should not, under any circumstances, be installed to an un-grounded electrical supply.
- Do not remove the grounding prong from the power cord. (See Figure 2).
- Do not use an adapter. (See Figure 3).
- Do not splash or spray water from a hose on the appliance. Doing so may cause an electrical shock, which may result in severe injury or death.
Electrical Connection
A grounded 115-volt, 15-amp dedicated circuit is required.
This product is factory equipped with a power supply cord that has a three-
pronged, grounded plug. It must be plugged into a mating grounding type
receptacle in accordance with the National Electrical Code and applicable
local codes and ordinances (see Figure 4). If the circuit does not have a
grounding-type receptacle, it is the responsibility and obligation of the
customer to provide the proper power supply. The third ground prong should
not, under any circumstances, be cut or removed.
NOTE
Ground Fault Circuit Interrupters (GFCI) are prone to nuisance tripping
which will cause the appliance to shut down. GFCI’s are generally not used on
circuits with power equipment that must run unattended for long periods of
time unless required to meet local building codes and ordinances.
INTERIOR ADJUSTMENTS
CAUTION
Shelf load limit is 35 lbs. Overloading the shelf could result in
deflection and risk of injury.
CAUTION
Make sure your cantilever shelf is secure on the shelf supports by pressing
down on the shelf before loading the shelf.
To remove the crisper :
Pull out until it stops. Lift up on the front of the pan, and remove it from
the frame.
To Add or Remove a Shelf
Remove the stored products from the shelf. Do not try to remove a loaded shelf
from the appliance. Grasp the shelf front with both hands, rotate the front
upward and lift out. (See Figure 42b). To install a shelf insert the shelf in
the appliance and insert the top hooks into the shelf support slots and drop
the shelf down so the hooks drop over the bottom of the slots.
CAUTION
Never try to move a loaded shelf, remove everything from the shelf before
moving. Use both hands when moving a shelf.
CARE AND CLEANING
Front Grille
Be sure that nothing obstructs the required airflow open-ings in front of the
cabinet. At least once or twice a year, brush or vacuum lint and dirt from the
front grille area (see page 8).
CAUTION
SHOCK HAZARD: Disconnect electrical power from the appliance before cleaning with soap and water.
Cabinet
The painted cabinet can be washed with either mild soap and water and
thoroughly rinsed with clear water. NEVER use abrasive scouring cleaners.
Interior
Wash the interior compartment with mild soap and water. Do NOT use an abrasive
cleaner, solvent, polish cleaner or undiluted detergent.
Care of Appliance
- Avoid leaning on the door, you may bend the door hinges or tip the appliance.
- Exercise caution when sweeping, vacuuming, or mop-ping near the front of the appliance. Damage to the grille can occur.
- Periodically clean the interior of the appliance as needed.
- Periodically check and/or clean the front grille as needed.
In the Event of a Power Failure
If a power failure occurs, try to correct it as soon as pos-sible. Minimize
the number of door openings while the power is off so as not to adversely
affect the appliance’s temperature.
Light assembly replacement
All models use an LED to illuminate the interior of the ap-pliance. This
component is very reliable, but should it fail, contact a qualified service
technician for replacement of the LED.
The following suggestions will minimize the cost of operating your refrigeration appliance.
- Do not install your appliance next to a hot appliance (cooker, dishwasher, etc.), heating air duct, or other heat sources.
- Install product out of direct sunlight.
- Ensure the front grille vents at front of appliance be-neath the door are not obstructed and kept clean to allow ventilation for the refrigeration system to expel heat.
- Plug your appliance into a dedicated power circuit. (Not shared with other appliances).
- When initially loading your new product, or whenever large quantities of warm contents are placed within the refrigerated storage compartment, minimize door openings for the next 12 hours to allow contents to pull down to compartment set temperature.
- Maintaining a relatively full storage compartment will require less appliance run time than an empty compartment.
- Ensure door closing is not obstructed by contents stored in your appliance.
- Allow hot items to reach room temperature before placing in the product.
- Minimize door openings and duration of door openings.
- Use the warmest temperature control set temperature that meets your personal preference and provides the proper storage for your stored contents.
- When on vacation or away from home for extended periods, set the appliance to the warmest acceptable temperature for the stored contents.
- Set the control to the off position if cleaning the appliance requires the door to be open for an extended period of time.
- For wine storage products: When serving temperatures are not required, return the compartment(s) set temperature to the ideal red and white wine long term storage tem perature of 13°C / 55°F.
STAINLESS STEEL MAINTENANCE
Background
Stainless steel does not stain, corrode, or rust as easily as ordinary steel, but it is not stained or corrosion-proof. Stainless steels can discolor or corrode if not maintained properly. Stainless steels differ from ordinary carbon steels by the amount of chromium present. t is this chromium that provides an invisible protective film on the surface called chrome-oxide. This protective chrome-oxide film on the surface can be damaged or contaminated, which may result in discoloration, staining, or corrosion of the base metal.
Care & Cleaning
Routine cleaning of the stainless steel surfaces will serve to greatly extend the life of your product by removing contaminants. This is especially important in coastal areas which can expose the stainless to severe contaminants such as halide salts, (sodium chloride). It is strongly recommended to periodically inspect and thoroughly clean crevices, weld points, under gaskets, rivets, bolt heads, and any locations where small amounts of liquid could collect, become stagnant, and concentrate contaminates. Additionally, any mounting hardware that is showing signs of corrosion should be replaced. The frequency of cleaning will depend upon the installation location, environment, and usage conditions.
Choosing a Cleaning Product
The choice of a proper cleaning product is ultimately that of the consumer,
and there are many products from which to choose. Depending upon the type of
cleaning and the degree of contamination, some products are better than
others. cleaning of most stainless steel products is to give the sur-faces a
brisk rubbing with a soft cloth soaked in warm water and a gentle detergent,
or mild mixture of ammonia. Rub-bing should, to the extent possible, follow
the polish lines of the steel, and always insure thorough rinsing after
cleaning. Although some products are called “stainless steel clean-ers,” some
may contain abrasives which could scratch the and some many contain chlorine
bleach which will dull, tarnish or discolor the surface if not completely
removed. After the stainless surfaces have been thoroughly cleaned, a good
quality car wax may be applied to help maintain the finish.
NOTE
Stainless steel products should never be installed, or stored in close
proximity to chlorine chemicals. Whichever cleaning product you chose, it
should be used in strict accordance with the instructions of the cleaner
manufacturer.
ENERGY SAVING TIPS
The following suggestions will minimize the cost of operating your refrigeration appliance.
- Do not install your appliance next to a hot appliance (cooker, dishwasher, etc.), heating air duct, or other heat sources.
- Install product out of direct sunlight.
- Ensure the front grille vents at front of appliance be-neath door are not obstructed and kept clean to allow ventilation for the refrigeration system to expel heat.
- Plug your appliance into a dedicated power circuit. (Not shared with other appliances).
- When initially loading your new product, or whenever large quantities of warm contents are placed within refrigerated storage compartment, minimize door openings for the next 12 hours to allow contents to pull down to compartment set temperature.
- Maintaining a relatively full storage compartment will require less appliance run time than an empty compart-ment.
- Ensure door closing is not obstructed by contents stored in your appliance.
- Allow hot items to reach room temperature before plac-ing in product.
- Minimize door openings and duration of door openings.
- Use the warmest temperature control set temperature that meets your personal preference and provides the proper storage for your stored contents.
- When on vacation or away from home for extended pe- riods, set the appliance to warmest acceptable tem- perature for the stored contents.
- Set the control to the “off” position if cleaning the appliance requires the door to be open for an extended period of time.
- For wine storage products:
When serving temperatures are not required, return the compartment(s) set temperature to the ideal red and white wine long-term storage temperature of 13°C / 55°F.
OBTAINING SERVICE
If Service is Required:
- If the product is within the first-year warranty period please contact your dealer or call Marvel Customer Service at 616.754.5601 for directions on how to obtain warranty coverage in your area.
- If the product is outside the first-year warranty period, Marvel Customer Service can provide recommendations of service centers in your area. A listing of authorized service centers is also available at www.marvelre-frigeration.com under the service and support section.
- In all correspondence regarding service, be sure to give the service number, serial number, and proof of purchase.
- Try to have information or description of the nature of the problem, how long the appliance has been running, the room temperature, and any additional information that may be helpful in quickly solving the problem.
- Table “B” is provided for recording pertinent information regarding your product for future reference.
For Your Records
Date of Purchase|
Dealer’s name|
Dealer’s Address|
Dealer’s City|
Dealer’s State|
Dealer’s Zip Code|
Appliance Serial Number|
Appliance Service Number|
Date Warranty Card Sent (Must be within 10 days of purchase).|
Product Liability
Field service technicians are authorized to make an initial assessment in the
event of reported damages. If there are any questions about the process
involved, the technician should call Marvel for further explanation. While
inspecting for defects or installation issues, photos should be taken to
document any damages or issues found. During the assessment, if the service
technician is able to find the source of the damage and it can be resolved by
replacement of a part, the servicer is authorized to replace the part in
question. The part that caused the damage must be returned to Marvel in its
entirety. The part must be clearly labeled with the serial number of the unit
it was removed from, the date, and the servicer who removed the part.
If the service technician determines the damage is the result of installation
issues (water connection/drain, etc.), the consumer would be notified and the
issues shall be resolved at the direction of the consumer.
If damage is evident and the service technician is unable to find the source,
Marvel must be contacted at 616.754.5601 for further direction.
1260 E. Van Deinse St Greenville, MI 48838
T: +1.616.754.5601
Website:
www.marvelrefrigeration.com
The original refrigeration experts since 1892.
Warranty Claims
The following information defines the parameters for filing a warranty claim:
- Valid serial number needed
- Valid model number needed
- Claims must be submitted online at www.marvelservice.com
- 60 day submittal deadline from date of completed service
- Only one repair or unit per warranty claim
- Part order numbers will be required when submitting for warranty labor
- Units must be registered prior to warranty submittal. Customers may register at marvel refrigeration com. Proof of purchase is required. We also accept the following information to update the warranty:
- New construction occupancy documents
- Closing paperwork
- Final billing – Remodel
- Warranty parts will be shipped at no charge after Marvel confirms warranty status. Please provide the model, serial number, part number and part description. Some parts will require color or voltage information.
Ordering Replacement Parts
Parts may be ordered online at partsformarvel.com
Or contact:
www.marvelrefrigeration.com (Servicers
choose “Login” for service account).
Phone Number: (616) 754-5601
NOTICE
Use only genuine Marvel replacement parts. The use of non-Marvel parts can
reduce performance, damage the unit, and void the warranty.
Warranty parts will be shipped at no charge after Marvel confirms warranty status. Please provide the model, serial number, part number and part description. Some parts will require color or voltage information. Marvel requires the return of original parts, we will inform you when the parts order is taken. This requirement will be noted on your packing list. A prepaid shipping label will be emailed to you. Please enclose a copy of the parts packing list and be sure the model and serial numbers are legible on the paperwork. Tag the part with the reported defect. Customers and non-authorized servicers may order nonwarranty parts at www.partsformarvel.com. Authorized servicers with a servicer login may order non-warranty parts at www.marvelrefrigeration.com.
Specifications & Handling
WARNING
Flammability warnings for a pure-iso-butane refrigerant.
Gloves and Eye Protection must be used.
- R-600a is considered non-toxic, but is flammable when mixed with air.
- Keep a dry powder type fire extinguisher in the work area.
- R-600a is heavier than air, do not allow any leakage/migration to low areas such as basements and stairs.
- Never use a torch on a fully charged refrigeration system.
- Never substitute Marvel OEM replacement parts or methods of construction.
- R-600a must be stored and transported in approved containers.
WARNING
- Only skilled and well trained service technicians permitted to service R-600a-equipped products.
- All tools and equipment must be approved for use with R-600a refrigerant.
- Local, state and federal laws, standards must be observed along with proper certification and licensing.
- Ventilation is required during servicing.
- No conversions to R-600a from any other refrigerants. OEM R-600a equipped unit only.
- Service area must be free of ignition sources.
- No smoking is allowed in the service area.
- All replacement electrical components must be OEM and installed properly (sealed and covered).
- If the evaporator is cold prior to service, it must be thawed prior to service.
- When using a vacuum pump, start pump before opening refrigeration system.
- Vacuum pump and recovery equipment should be at least 10 feet from the work area.
- It is recommended that a simple LPG gas detector is on site during service.
- Ensure that all R-600a is removed from the system prior to brazing any part of the sealed system.
- Only a clean, dry leak free system should be charged with R-600a.
R-600A SPECIFICATIONS/LABELING
- R-600a equipped products are labeled (both the unit and the compressor).
- R-600a is colorless and odorless.
- R-600a is considered non-toxic, but is flammable when mixed with air.
- Do not remove or alter any R-600a labeling on the product.
- Use only a refrigerant grade R-600a from a properly labeled container.
RECOVERING/RECLAIMING R-600A
- (R-600a has been exempted from recovery/reclaiming requirements by the US EPA)
- Recovery/Reclaiming equipment must be approved for use with R-600a.
- Ensure the evaporator is at room temperature prior to recovery /reclaiming R-600a.
- Use a common piercing pliers or piercing valve to remove R-600a from the compressor process tube. (Note: Piercing devices must not be lelt on the system and must be replaced with a Schrader type valve.)
Evacuate/reclaim via the piecing pliers to ensure the system is empty of R-600a before any system work is performed.
The recovery cylinder must be evacuated (no air inside) prior to accepting R-600a. The recovery cylinder must not be filled more than 45%safe fill level and refrigerants must not be mixed. The recovery cylinder must be clearly marked with R- 600a and Flammable Warning labels. Ensure proper ventilation during recovery/reclaiming of R- 600a. Start vacuum pump/recovery pump prior to piercing the compressor process tube. Follow recovery/reclaim OEM instructions for the specific equipment used.
SYSTEM REPAIR
Ensure no residual R-600a refrigerant is left within the system prior to
repair (simple venting is not sufficient). Evacuate and charge with dry
nitrogen for leak checks. Repair leaks or replace system parts as required.
When re-brazing, the system must be purged with dry nitrogen and at least one
access point open to the atmosphere. When re-brazing, proper ventilation is
required along with constant monitoring for the presence of R600a refrigerant.
The filter dryer must be replaced any time the sealed system is serviced. No
system should be open to the atmosphere for longer than 15 minutes to avoid
moisture migration into the system components.
LEAK DETECTION
After removal of the R-600a, the unit can be charged with dry nitrogen or
helium. Electronic leak detection or soap solution can be used to check for
nitrogen/helium leaks.
Never use a halide torch or lighted match to check the system for leaks at any time. The high side of the refrigeration system (compressor discharge to outlet of drier) must be leak tested with the compressor running.
The low side of the refrigeration system (evaporator, compressor and suction line) must be leak tested with the compressor off (equalized pressure).
RECHARGING
No air is ever to be allowed inside the refrigeration system (R-600a
refrigerant or dry nitrogen only). Never use a torch on a fully charged
refrigeration system. Install a Schrader Type access port on the compressor
process stub.
Evacuate the system to 100 microns prior to charging. Weigh in the R-600a charge using a refrigerant scale. (run compressor an extra two minutes to clear the charging hoses). Seal the Schrader Type access port, a proper cap and seal must be used to close the system.
SUMMARY
Safely handling R-600a requires proper procedures and training. R-600a
approved service tools must be used. R-600a labeling must not be removed or
altered. Proper ventilation during service is required. Never apply a torch to
a charged R-600a refrigeration system. Use OEM replacement service parts and
do not alter the construction of the unit.
System Diagnosis Guide
REFRIGERATION SYSTEM DIAGNOSIS GUIDE
WARNING
Only skilled and well trained service technicians permitted to service R-600a
equipped products. All tools and equipment must be approved for use with
R-600a refrigerant. Local, state and federal laws, standards must be observed
along with proper certification and licensing. Ventilation is required during
servicing. No conversions to R-600a from any other refrigerants. OEM R-600a
equipped unit only. Service area must be free of ignition sources. No smoking
is allowed in the service area. All replacement electrical components must be
OEM and installed properly (sealed and covered).If the evaporator is cold
prior to service, it must be thawed prior to service. When using a vacuum
pumP, start pump before opening refrigeration system. Vacuum pump and recovery
equipment should be at least 10 feet from the work area. It is recommended
that a simple LPG gas detector is on site during service. Ensure that all
R-600a is removed from thesystem prior to brazing any part of the sealed
system. Only a clean, dry leak free system should be charged with R-600a.
All resistance readings are + 10%
HOUSEHOLD PRODUCT WARRANTY
Marvel Refrigeration (Marvel) Limited Warranty
ONE-YEAR LIMITED PARTS & LABOR WARRANTY
For one year from the date of original purchase, this warranty covers all
parts and labor to repair or replace any part of the product that proves to be
defective in materials or workmanship. For products installed and used for
normal residential use, material cosmetic defects are included in this
warranty, with coverage limited to 60 days from the date of original purchase.
All service provided by Marvel under the above warranty must be performed by a
Marvel factory-authorized servicer, unless otherwise specified by Marvel.
Service provided during normal business hours.
TWO-YEAR LIMITED PARTS & LABOR WARRANTY (MARVEL PROFESSIONAL PRODUCTS)
For two years from the date of original purchase, this warranty covers all
parts and labor to repair or replace any part of the product that proves to be
defective in materials or workmanship. For products installed and used for
normal residential use, material cosmetic defects are included in this
warranty, with coverage limited to 60 days from the date of original purchase.
All service provided by Marvel under the above warranty must be performed by a
Marvel factory-authorized servicer unless otherwise specified by Marvel.
Service is provided during normal business hours.
AVAILABLE THIRD-YEAR LIMITED WARRANTY (MARVEL PROFESSIONAL PRODUCTS)
For designated Marvel Professional products, Marvel offers a one year
extension of the two year warranty coverage from the date of purchase, free of
charge. To take advantage of this third-year warranty, you must register your
product with Marvel within 60 days from the date of purchase at
marvelrefrigeration.com and provide proof of purchase.
LIMITED FIVE-YEAR SEALED SYSTEM WARRANTY
For five years from the date of original purchase, Marvel will repair or
replace the following parts, labor not included, that prove to be defective in
materials or workmanship: compressor, condenser, evaporator, drier, and all
connecting tubing. All service provided by Marvel under the above warranty
must be performed by a Marvel factory-authorized servicer unless otherwise
specified by Marvel. Service is provided during normal business hours.
WARRANTY TERMS
These warranties apply only to products installed in any one of the fifty
states of the United States, the District of Columbia, or the ten provinces of
Canada. The warranties do not cover any parts or labor to correct any defect
caused by negligence, accident or improper use, maintenance, installation,
service, repair, acts of God, fire, flood or other natural disasters. The
product must be installed, operated, and maintained in accordance with the
Marvel User Guide. The remedies described above for each warranty are the only
ones that Marvel will provide, either under these warranties or under any
warranty arising by operation of law. Marvel will not be responsible for any
consequential or incidental damages arising from the breach of these
warranties or any other warranty, whether express, implied, or statutory. Some
states do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitation or exclusion may not apply to you. These
warranties give you specific legal rights, and you may also have other rights
which vary from state to state. Any warranty that may be implied in connection
with your purchase or use of the product, including any warranty of
merchantability or any warranty fit for a particular purpose is limited to the
duration of these warranties and only extends to five years in duration for
the parts described in the section related to the five-year limited warranty
above. Some states do not allow limitations on how long an implied warranty
lasts, so the above limitations may not apply to you.
- The warranties only apply to the original purchaser and are non-transferable.
- These warranties cover products installed and used for normal residential use only.
- The warranties apply to units operated outside only if designed for outdoor use by model and serial number.
- Replacement water filters, light bulbs, and other consumable parts are not covered by these warranties.
- The start of Marvel’s obligation is limited to four years after the shipment date from Marvel.
- In-home instruction on how to use your product is not covered by these warranties.
- Food, beverage, and medicine loss are not covered by these warranties.
- If the product is located in an area where Marvel factory-authorized service is not available, you may be responsible for a trip charge or you may be required to bring the product to a Marvel factory-authorized service location at your own cost and expense.
- Units purchased after use as floor displays, and/or certified reconditioned units, are covered by the limited one year warranty only and no coverage is provided for cosmetic defects.
- Signal issues related to Wi-Fi connectivity are not covered by these warranties.
For parts and service assistance, or to find Marvel factory-authorized service near you, contact Marvel Refrigeration:
- MarvelRefrigeration.com
- techsupport@MarvelRefrigeration.com
- +616.754.5601
- 1260 E. Van Deinse St., Greenville, MI 48838
- www.marvelrefrigeration.com
References
- Premium Undercounter Products for Home & Outdoor | Marvel Refrigeration
- tion.com
- Premium Undercounter Products for Home & Outdoor | Marvel Refrigeration
- partsformarvel.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>