dacor DRT304S Slide-In Gas Rangetops

WARNING

  • Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information.
  • This appliance must be installed in accordance with the accompanying installation instructions.

Product Dimensions

dacor DRT304S Slide-In Gas Rangetops 1

RANGETOP WIDTH (A)

DRT304S| 29 7/8” (75.9 cm)
DRT366S| 35 7/8” (91.1 cm)

dacor DRT304S Slide-In Gas Rangetops 2

Electrical and Gas Supply Requirements

ELECTRIC CIRCUIT REQUIREMENTS

Circuit Required| Total Connected Load
120 Vac 60Hz, 15 Amp. (3 wire)| 1.0 Amp @ 120 Vac, 60 Hz.
**GAS SUPPLY PRESSURE REQUIREMENTS***

Gas Type| Manifold Pressure| Minimum Gas Supply Pressure
Natural Gas| 5” Water Column| 6” Water Column
Propane (LP)| 10” Water Column| 11” Water Column

  • Maximum gas supply pressure for all models is 1/2 p.s.i.

Cabinet and Countertop Layout

Installation of a non-combustible material* (up to the hood) or a backsplash is always recommended, and mandatory if the distance to the back wall from the rangetop is less than 2 1/2” (Figure 2). When installing a backguard, use only Dacor model number AEB3609.

dacor DRT304S Slide-In Gas Rangetops 3

dacor DRT304S Slide-In Gas Rangetops 4

CABINET/COUNTERTOP DIMENSIONS -ISO VIEW

  1. Vertical to combustible surface from cooktop grate level; if installing an overhead vent hood, also check the hood specifications for minimum required clearances.
  2. See Cabinet/Countertop Dimensions – Top View
  3. Not applicable for cabinets more than a horizontal distance of 10” (25.4 cm) from the edge of the rangetop.

dacor DRT304S Slide-In Gas Rangetops 5

Model No. B C
DRT304S 30” (76.2 cm) 30” (76.2 cm)*

36” (91.4 cm)**

DRT366S| 36” (91.4 cm)| 36” (91.4 cm)*

42” (106.7 cm)**

  • Minimum ** Recommended

Cutout tolerances: +1/16” (+1.6 mm), -0, unless otherwise stated

dacor DRT304S Slide-In Gas Rangetops 6

Model No. B – Cutout Width D E
DRT304S 30” (76.2 cm) 13 3/8” (34.0 cm) 10 1/8” (25.7 cm)
DRT366S 36” (91.4 cm) 16 5/8” (42.2 cm) 11 3/16” (28.4 cm)

dacor DRT304S Slide-In Gas Rangetops 7

NOTE: Gas and electrical connections may only be routed through the bottom of the rangetop when installed with a downdraft vent.

Model No. B – Cutout Width D E F – Vent Cutout

DRT304S

with ERV3015*

| 30”

(76.2 cm)

| 13 3/8”

(34.0 cm)

| 10 1/8”

(25.7 cm)

| 27 1/2” (69.9

cm)

DRT366S

with ERV3615*

| 36”

(91.4 cm)

| 16 5/8”

(42.2 cm)

| 11 3/16”

(28.4 cm)

| 33 1/2”

(85.1 cm)

  • Use only downdraft vent model specified. Downdraft vent is not compatible with DRT rangetops having a serial number starting with letters “SA.”