Televes 719604 EUROswitch 9x Satellite MultiSwitch User Manual

June 6, 2024
Televes

EUROswitch 9x
User manual

Important safety instructions

Safe installation

  1. Read these instructions before handling or connecting the equipment. Keep these instructions. Heed all warnings. Follow all instructions.
  2. Clean only with dry cloth.
  3. Do not use this apparatus near water. Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such as glasses, shall be placed on the apparatus.
  4. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. Please allow air circulation around the equipment.
  5. Do not place the equipment in a highly humid environment.
  6. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. Do not place naked flames, such as lighted candles on or near the product.
  7. Do not place the equipment in a place where it can suffer vibrations or shocks.
  8. Only use attachments/accessories specified by the manufacturer.

Safe operation of equipment

  • Ambient temperature should not be higher than 45ºC.
  • Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

Warning

  • This apparatus must be securely attached to the floor/wall in accordance with the installation instructions. Do not connect the equipment to the mains supply until it is screwed to the wall.

| | |
---|---|---|---
Symbology| Equipment designed for indoor use.| The equipment complies with the CE mark requirements.| The product is EAC certified

PRODUCT RANGE

Description Ref / Art. Nr.
9x9x8 Euroswitch 719601

MSE98C
9x9x12 Euroswitch| 719602
MSE912C
9x9x16 Euroswitch| 719603
MSE916C
9x9x24 Euroswitch| 719604
MSE924C
9x9x32 Euroswitch| 719605
MSE932C
9×9 Ampli4  er| 719609
MSE927V
PSU 12V V V| 593203
732101
732210
732802| 2,0A
0,8A
1.5A
2,8A
PSU 18V V V| 732010
732001| 2,0A

EUROSWITCH MSW 9x

719601- MSE98C 9x9x8
719602 – MSE912C 9x9x12
719603 – MSE916C 9x9x16
719604 – MSE924C 9x9x24
719605 – MSE932C 9x9x32

EUROSWITCH AMPLIFIER 9x

719609 – MSE927V 9×9
New range of input/multiple output switches, (from 8 to 32, according to reference). It can be used as a cascade element since it has 9 outputs to connect to other switches and increase the number of users. Main specs are:

  • Highly compact.
  • Poor tap and through losses.
  • Wide range of power supply voltage : 12­-18V .
  • Low power consumption.
  • Power up distributed along the installation.
  • High insulation between inputs and outputs.

This range of products has been designed with the ECO system: as the number of users decreases, the power consumption of the system will decrease as well. The range is completed with the line amplifier 9x, which allow to restore the level of signals when these have reached a low value to continue their distribution.

EUROSWITCH MSW 9x

1.- Input satellite connectors/ Output to satellite trunk lines
2.- Input terrestrial connector/Output to terrestrial trunk line
3a.- Output users connectors (1…8)
3b.- Output users connectors (9…16)| 4.- DC power supply input jack
5.- Tforce terrestrial amplifier switch
6.- Trunk lines autoload switch| 7.- Ground connection
8a.- SAT gain switch for outputs 1…8
8b.- SAT gain switch for outputs 9…16 ( *)- Not available
---|---|---

TFORCE SWITCH
Tforce ampli# er control of the terrestrial signal in the user outputs:
Active mode (Tforce ON): 0 dB
Passive mode (Tforce OFF): -30 dB
The values are approximate and are relative to the signal level in the terrestrial trunk.

AUTOLOAD SWITCH
Autoload ON: Single Multiswitch installation (stand alone) or terminal Multiswitch in a cascade.
Autoload OFF: Multiswitch installed in the middle of a cascade.
Note: Active Mode (Tforce ON) and Autoload ON require that an element in the installation powers it up.

SAT GAIN SWITCH
Gain in the SAT band can be selected individually for each group of users (see cover) to provide a balanced output.

EUROSWITCH AMPLIFIER 9x

1.- Input satellite connectors/Output to satellite trunk lines
2.- Input terrestrial connector/Output to terrestrial trunk line
3.- DC power supply input jack| 4.- Terrestrial trunk line power-up switch
5.- Gain level and slope adjusting of output signals
6.- Ground connection
---|---

TERR DC switch allows powering the terrestrial trunk line to power the installed head-end elements in Euroswitch ampli# ers.

All the elements of the installation, whether Multiswitches or ampli# ers which have a power supply, connect this power supply to the satellite trunk lines. As a result of this, they power themselves up, and besides, they provide power supply to other elements in the installation lacking a power source, like for instance other Multiswitches or ampli# ers and also the LNBs.
The power supplies available in the installation are shared by all its elements, which allow to minimize their number. The dimensioning of the number of power supplies will be carried out as a function of the total power consumption of the installation, with the corresponding security margin, equally distributed throughout it. In case of large installations that require the use of ampli# ers, these will be the reference elements to place the power supplies.
The installation can also be powered up by other means, the satellite trunk lines of some of their elements. In all cases, the maximum allowed current in each satellite trunk line must be taken into account. The terrestrial trunk line is isolated of the satellite trunk lines and does not provide power to the installation, though it allows voltage pass to power up installed Head-end elements (BOSS antenna or preampli# er). Such powering could be provided by the installation ampli# ers, activating to ON the Switch “TERR DC” (4).
When the installation does not have any power supply, he Multiswitch will continue to correctly working, assuming that the signals in the trunk lines are powered up/provided by other means. in this case, neither the active mode of the Tforce Terrestrial ampli# er will be available (passive mode working) nor the autoload of the trunk lines.

powering

719601- MSE98C
719602 – MSE912C
719603 – MSE916C
719604 – MSE924C
719605 – MSE932C

719609- MSE927V

Installation mode

  1. Stand alone

Examples of implementation

2. Cascade multi switches installation

Powered from trunk lines

• DECLARATION DE CONFORMITE https://doc.televes.com

Manufacturer
Televes, S.A.U., CIF: A15010176, Rua/Benefica de Conxo, 17, 15706 Santiago de Compostela, A Coruña, SPAIN,
tel.: +34 981 522200, [email protected].

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Televes User Manuals

Related Manuals