About your new thermostat
This thermostat is used to control system, EM heat activation, adjustable compressor delay time and O/B changeover. It is with tempered touch sensitive button, quick connecting terminals to save installer’s time. 7 days programmable and four modes everyday make users’ life convenient and comfortable.
Thermostat passed FCC standard.
Thermostat box you will find
Thermostat | Manual | Screws | QC pass certificate |
---|---|---|---|
**** |
Service
We offer the warranty of 18 months from the sales day.
If it is not the problem of quality or beyond the warranty time, we will
charge for the after-sale service.
Technical Data of your thermostat
Sensor: NTC3977 10K Accuracy:±1℉
Temp. Range: 41℉ -95℉ Power Consumption:<1.5W
Timing error: <1%
Power Supply: AC24V, 50 ~60Hz
Shell Material: PC (Fireproof)
Dimension: 132x90x23.5mm
Installation box: US Standard box
Ambient Temp.: 0 ℉~ 113℉, 5 ~ 95%RH(Non condensing)
Storage Temp:- 41℉~ 140℉
Features of your thermostat
-
Apply with various kind of heating and cooling system.
Including Single stage, Multi-stage And Heat Pump (Up to 3-stage heat, 2-stage cool, with Aux. Or Emergency heat) -
Wireless WiFi: APPs for iOS and Android devices.
-
Voice control: Work with Amazon Echo and Google Assistant.
-
4’’ LCD display with backlight
-
7days 4 time periods scheduling. Set the target heating and cooling temperature respectively.
-
Both Vacation mold and hold duration mode available for comfort and energy saving
-
Temperature display of Celsius or Fahrenheit scale
Home screen quick reference
Operation
:Switching System Mode
Short press button to select system mode: HEAT, COOL, AUTO, EMER, OFF.
v:Comfirm button
Press this button to comfirm your settings.Press again select
Schedule、Permanent Hold and Energy saving
Fan Mode
Press this button to select fan on, auto and cycle
Setting the time
When connecting the thermostat to Wi-Fi, the time will sync automatically.
If not connecting to Wi-Fi, Press Auto Mode to set second-hour-weekf Short
press button to select Auto.Short press button to enter AUTO mode
Setting the Lock
Press and hold button at the same time over 7seconds to lock/unlock your
thermostat
WIFI reset
Long press seconds to reset WIFI when power off
Check external sensor temperature
(external sensor only)
Press and to check external sensor temperature
Setting a Schedule
When connecting the thermostat to Wi-Fi, the schedule is programmed based
on time and temperature set points from the Sensi app. If you are not
connecting to Wi-Fi, follow these steps to set a basic 7 day schedule with 4
mandatory set points.Long press button above 7secends to enter weekly program
funtion.Short press button to set week-hour-cool temperature-heat temperature
,Short press to return back.Press+/- to set the parameters Long press at the
same time over 7seconds to go back factory weekly program settings
Example Schedule
Week Period | Get up | Go outside | Go home | Sleep |
---|---|---|---|---|
Mon-Sun | Time | 6:00 | 8:00 | 18:00 |
Cool Temp | 79℉ | 83℉ | 79℉ | 83℉ |
Heat Temp | 72℉ | 61℉ | 72℉ | 61℉ |
Wiring Diagram
RH: Power for heating, 24V
RC: Power for cooling, 24V
G: Indoor blower (fan)
S: Connect to S on C-wire adapter
O/B: Changeover (reverse valve) connection for heat pump or zone panel
systems
Y: First outdoor stage cooling on conventional systems or first heat and
cool on heat pump systems
NTC+: Outer Sensor+
b Outer Sensor
C: Common wire, 24V
W /AUX: First indoor stage heat on conventional systems or first stage
auxiliary
Vocation function
Long press fan button over 7seconds to enter Vocation mode.Short press fan
button check days->cool temp
->heat temp.Long press button for 7 sec.When you see the parmeter flash.Short press fan button to set
the paremeters.Short press to excit Setting Energy Saving Mode Short press
button to enter energy saving.The LCD will show on. If you need change engery
saving temp.
Long press button and button at the same time over 7sfeconds.Short press time
button to set The order is ECO cool temp->ECO heat temp
Configuration Menu
No.| Menu item| Short Icon| Selection Range| Notes|
Default
---|---|---|---|---|---
1| Set Up HVAC Equipment (Outdoor)| OUT| Outdoor Setup AC1/HP1/None| | AC1
2| Set Up HVAC Equipment (Indoor)| IND| Indoor Setup GA1/EL1/None| When you
select heat pump (AUX) GA1/EL1/NON option| EL1
3| Circulatio fan switch| FA1| ON/OFF| | ON
4| Circulatio fan Setting range| FA2| 10%-100%| If you set the Circulating Fan
to 50%, the fan will run 30 minutes every hour. If any heat/cool cycles occur
during the hour, their runtime is subtracted from the overall fan run time.|
30%
5| Auto Mode| AUT| ON/OFF| | ON
6| Compressor 1 delay| CO1| 1-5min| | 3
7| Compressor 2 delay| CO2| 1-5min| | 3
8| Reversing Valve Position| OB| O/B O:Cool B:Heat| Only Item 1 select out.
HP1/HP2 workable| 0
9| External sensor| SEN| ON/OFF| | OFF
10| AUX lockout| APL| ON/OFF| Item 1 should be HP1 Item 2 should be
GA1/EL1 Item10 should ON. Only all of three items workable| OFF
11| AUX lockout Temp| AO| -15~20 , 5-68| Item 1 should be HP1 Item 2
should be GA1/EL1 Item10 should ON.Item 12 ON. Only all of four items
workable| 36
12| Heat Pump Lockout| COL| ON/OFF| Item 1 should be HP1 Item 2 should be
GA1/EL1 Item 10 should ON. Only all of three items workable| OFF
13| Heat Pump Lockout Temp| AC| -15~20 , 5-68| Item 1 should be HP1 Item 2
should be GA1/EL1Item10 should ON.Item 13 ON. Only all of four items workable|
32
14| Temperature Compensation| CL| -9~9| | 0
15| C/F selecable| FC| F/C| | F
16| Maxmum TemperatureRange| AH| 20-50℃ ,68-95℉| | 95
17| Minimum Temperature Range| AL| 5-20℃ ,41-68℉| | 41
18| Time| TI| 12 24| | 12
19| UV Reminder time setting| UU| 0-36| | 12
20| ChagPad Reminder Time Setting| PAD| 0-36| | 12
21| ChagFilter Reminder Time Setting| FIL| 0-36| | 12
Note:
Item 4: Circulating fan
Short press fan button to select cycle.Press to comfirm this function running.
If you want to circulate the air in your home using your indoor blower fan,
you can set this feature at the thermostat. A percentage is selected to
indicate how often the fan should run each hour, You can set 5% increments
from 10% – 100%.
EXAMPLE:
If you set the Circulating Fan to 50%, the fan will run 30 minutes every hour.
If any heat/cool cycles occur during the hour, their runtime is subtracted
from the overall fan run time Item 21 Select UV lamp replacement run time This
is the reminder to change UV lamp . Select starts to counting for 0 day to 360
days. The thermostat will display “Chg UV” when UV time (Xxdays).
APP will also reminder
item 22 Chg pad replacement run time
This is the reminder of replacement run time of Chgpad .
Select starts to counting for 0 day to 360 days.
The thermostat will display “Chg Pad” when Chg pad (XXdays).LCD will
display.APP will also reminder
item 23 Chg Filter replacement run time
This is the reminder of replacement run time of Chg Filter . Select starts to
counting for 0 day to 360 days.
The thermostat will display “Chg Filter” when Chg Filter (XXdays).LCD will
display.APP will also reminder All these three items you could check according
to bellow steps.
Long press Menu button over 7seconds to enter check page.Short press menu
button to next item.
Press+ and – button over 7seconds to reset.
Sensor broken
Er1: Inner sensor broken or not work
Er2: External sensor broken or not work
Installing your thermostat
This product is suitable for US standard wall box.
-
Connect the wire of power and other equipment into the terminals.Fix the wall plate into the wall box by a screwdriver.
-