CYFAN
230V / 24V DC SELV Surface Mounted &
Semi-Recessed Domestic Extract Fans
**Installation Manual
IP×4
Wall / Window
Mounted
Installations Only
**
SAFETY INFORMATION
- The provision of the electrical supply and the connection of the unit to the electrical supply must be carried out by a qualified electrician in accordance with the latest edition of the wiring regulations.
- 24V fan units must be installed in accordance with these instructions and IEE Wiring Regulations BS7671 for SELV installations.
- In order to avoid a hazard due to inadvertent resetting of the thermal cut-out, this appliance must not be supplied through an external switching device, such as a timer, or connected to a circuit that is regularly switched on and off by the utility.
- All-pole disconnection from the mains as shown in the wiring diagram must be incorporated within the fixed wiring and shall have a minimum contact separation of 3mm in accordance with the latest edition of the wiring regulations.
- Isolate from the power supply before removing any covers. During installation/maintenance ensure all covers are fitted before switching on the mains supply.
- Ducting must be securely fixed with screws to the spigot to prevent access to live parts. Duct runs terminating close to the fan must be adequately protected by suitable guards.
- Precautions must be taken to avoid the back-flow of gases into the room from the open flue of gas or other fuel-burning appliances.
- This appliance should not be used by children or persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning the safe use of the appliance by a person responsible for their safety. Children shall not play with the appliance. Cleaning and user maintenance shall not be carried out by children.
1.1 Hazard Symbols
REFER TO INSTRUCTION MANUAL
Read and understand the installation and maintenance manual before installing,
operating, or maintaining this product.
1.2 Important Information
This manual contains important information on the safe and appropriate
assembly, transport, commissioning, operation, maintenance, disassembly, and
simple troubleshooting of the product. While the product has been manufactured
according to the accepted rules of current technology, there is still a danger
of personal injury or damage to equipment if the following general safety
instructions and the warnings contained in these instructions are not complied
with.
- Read these instructions completely and thoroughly before working with the product.
- Keep these instructions in a location where they are accessible to all users at all times.
- Always include the operating instructions when you pass the product on to third parties.
1.3 Personal Protective Equipment
The following minimum Personal Protective Equipment (PPE) is
recommended when interacting with Nuaire products:
-
Protective Steel Toed Shoes – when handling heavy objects.
-
Full Finger Gloves (Marigold PU800 or equivalent) – when handling sheet metal components.
-
Semi Fingerless Gloves (Marigold PU3000 3DO or equivalent)
– when conducting light work on the unit requiring tactile dexterity. -
Safety Glasses – when conducting any cleaning/cutting operation or exchanging filters.
-
Reusable Half Mask Respirators – when replacing filters that have been in contact with a normal room or environmental air. Nuaire would always recommend a site-specific risk assessment by a competent person to determine if any additional PPE is required.
INTRODUCTION
The Nuaire CYFAN centrifugal extract fan is a major advancement and has
been designed to meet the flow rates for all wet room applications such as the
bathroom, kitchen, utility, WC, etc.
The unit discharges air through a 100mm or 125mm diameter spigot which for
surface and semi-recessed mounted units exits at the rear of the unit. The
subsidiary spigot kit allows the fan to extract air through the side of the
fan via a 50mm diameter spigot.
The motor is a 24V brushless DC. Bearings are sealed, self-lubricating ball
types with integral locked rotor protection. Units are supplied with a
separate transformer enclosure if fans are required for SELV usage.
2.1 Unit Operation Includes 230V To 24V Conversion, Continuous Or
Intermittent
The fan can be converted to operate as a 24V DC SELV for zone 1 and 2
applications. The fan has the option to select continuous or intermittent
operation up to an installed performance of 60 l/s.
2.2 Mounting options
The CYFAN range can be:
- Surface Mounted
- Semi-Recessed Mounted : Using the optional extra Semi-Recessed mounting frame kit suitable for 100mm and 125mm diameter duct consists of the mounting plate and mounting flange.
- Window Mounted : Using the optional kit.
- Surface Mounted With Side Spigot : Using the optional kit (see section 2.3 for part numbers).
2.3 CYFAN Ancillaries
- Wall Mounting Kit
Part Number | Colour |
---|---|
CYFAN-WALLKIT-WH | White |
CYFAN-WALLKIT-BR | Brown |
CYFAN-WALLKIT-COT | Cotswold |
CYFAN-WALLKIT-TC | Terracotta |
- Optional window mounting kit – Part number: CYFAN-WKIT
- Optional spigot kit for ventilation of adjacent bathroom/ separate toilet – Part number : CYFAN-DKIT
- Semi-recessed mounting kit – Part number: CYFAN-RKIT
- Optional filter available – Part number: 7702017
2.4 Box Contents
The following components are included:
2.4.1 Fan Body
- Fan Scroll including Motor and Removable Impeller
- Control / PSU PCB, complete with Boost Pull Switch
- PCB Cover
- Front Grille
- Front Cover
- 100mm Spigot (fitted)
- Additional 125mm Ø Spigot
- 2x 100mm Back Draught Spigot
- 2x 125mm Back Draught Spigot
- 24V Transformer Enclosure
- 15mm deep mounting skirt
2.4.2 Fixing Kit
- 8x No6 x 3⁄4″ Pozi Pan Screw
- 6x No6 x 1⁄2″ Pozi Pan Screws
- 2x No8 x 3⁄8″ Pozi Pan Screws
- 3x Cable Clamps
- 1x Shutter Spring
2.5 Dimensions (mm)
2.5.1 CYFAN
2.5.2 Window Kit (Optional)
INSTALLATION PREPARATION
Before commencing any work read the following instructions carefully and
ensure you have the necessary competency to complete the work safely.
The installation must be completed by competent persons in accordance with
good industry practice and should conform to all governing and statutory
bodies i.e. IEE, CIBSE, HVCA, etc.
If the environment in which the product is installed also houses a fuel-
operating device (water heater, methane stove, etc., that is not a “sealed
chamber” type), it is essential to ensure adequate air intake, to ensure good
combustion and proper equipment operation.
Ensure adequate air return into the room in compliance with existing
regulations in order to ensure proper device operation. Ensure the fan’s
capability by checking the performance fan curve. Flexible ducting is not
recommended.
3.1 Spigot Change
For kitchen installations, it is recommended that the 125mm diameter spigot is
fitted.
- Remove the front cover and grille.
- Remove fan scroll from fan casing (Do not disconnect wiring).
- Using a PH2 screw head driver remove 4 of No.8 x 1/4″ screws.
- Remove spigot.
- Place the required spigot into position (Figure 4).
- Replace 4x No8 1⁄4″ screws.
- Replace the fan scroll on the fan casing.
- Replace front cover and grille.
3.2 Backdraught Shutter Installation
The CYFAN kit comes complete with back draught shutters for 100mm and 125mm
spigots however these are not fitted as standard and should not be used when
using your CYFAN in continuous operation.
It is also recommended that you should not fit back draught shutters if
your intermittent operation duties are below 15 l/s and for installations
other than directly through the wall application to avoid failure of the
shutters opening.
Please follow these simple steps to fit your back draught shutters if
required: It is advised to fit the shutters before installing the fan unit.
- Collect all required parts
- 125mm shutters (2 of 41285) or 100mm shutters (2 of 41286)
- Spring (Part of Fixing Kit 770173)
Fit 1 of the required diameter shutters with the part number facing in, by
placing the bottom pin into the bottom hole, slightly deflecting the shutter
and then fit the top pin into the top hole. Repeat this process for the other
shutter.
3.3 Conversion from 230V to 24V
- Unpack the fan unit, components, and transformer. Ensure that all parts listed on page 1 are present. If not please contact the manufacturer for replacement / missing parts.
- Place the front cover and inlet grille to one side.
- Remove the PCB cover by removing 2 off No.6 x 1/2″ screws.
- Partially remove the PCB assembly from the fan casing by placing a fingertip behind the dip switches and pulling the PCB away from the fan casing (Figure 6).
- Separate section 2 of the PCB from section 1 by cutting the tabs in the positions shown (Figure 7). Replace section 2 of the PCB into the fan unit.
3.4 Transformer Enclosure (24 Volt units only)
24V fan units must be installed in accordance with these instructions
and IEE Wiring Regulations BS7671 for SELV installations.
The enclosure containing the transformer is intended to be mounted out of
sight (e.g. in a loft, cupboard, under floorboards, etc.).
However, if this is not possible the transformer enclosure should be mounted
as close to the ceiling, or as far from the “splash zone” as possible (see
below for definition of the splash zone).
As can be seen from the table of wiring sizes, it is advisable to place the
enclosure as close to the fan as possible to reduce the costs of wiring and
assist in installation.
3.4.1 Splash Zone
The ‘Splash Zone’ can be considered to be an area within a bathroom or shower
room where a person using the bath or shower can effectively reach.
An arm’s reach is defined as 0.6 meters from the edge of the bath or shower up
to a height of 2.25 meters.
- Installing the Transformer
- Remove the transformer cover.
- Position the transformer base enclosure on the mounting surface and route cables through knockouts. Mark the fixing points on the mounting surface. Secure using suitable fixings (by others).
- Before fitting section 1 of the PCB into the transformer enclosure connect the wiring as shown in section “5.3.5 Window Kit Installation The procedure” on page 8. Fit section 1 of the PCB by first slotting the bottom edge (Figure 9) into the fixing clip inside the base of the transformer enclosure then press on the transformer and terminal block until the PCB clicks into place. Complete by replacing the transformer cover using the screws provided. Keep vents clear of obstruction.
- Complete the installation of components by securing the PCB cover on the fan. No earth is to be connected between transformer and fan.
3.4.2 Wire Sizes for Transformer Installation
It is important to note that the size of wire used between the transformer and
the fan unit can have an adverse effect on the units’ performance if the
following table is not adhered to.
To avoid cable insulation contact with a hot transformer, always use the
knockout at the PCB end.
Cable Type | Cable Size |
---|---|
Main Supply – 230V | 0.5 mm sq |
Transformer to Fan Cable Runs (max. 10 metres ) – 24V Units Only
Up to 2m| 0.75 mm sq
Up to 4m| 1.0 mm sq
Up to 6m| 1.5 mm sq
Up to 10m| 2.5 mm sq
ELECTRICAL INSTALLATION
Disconnection from the supply mains must be incorporated within the fixed
wiring in accordance with the wiring regulations and shall have a minimum
contact separation of 3mm in accordance with the latest edition of the IEE
Wiring Regulations.
Before commencing work, ensure the unit, is switched live and any controls
are electrically isolated from the electric supply.
4.1 Wiring Diagrams – 24V
4.1.1 Wiring – 24V SELV Via Remote Switch
4.1.2 Wiring – 24V SELV Via Pull Cord
4.2 Wiring Diagrams – 230V
4.2.1 Wiring – 230V Via Remote Switch
4.2.2 Wiring – 230V Via Pull Cord
4.3 Wiring Diagrams – 230V Two Rooms Via Side Spigot
4.3.1 Wiring – 230V Two Rooms Via Remote Switches
4.3.2 Wiring – 230V Two Rooms Via Pull Cords
MECHANICAL INSTALLATION
5.1 Surface Mounted Installation
5.1.1 Fan Installation
Installation must be completed by qualified personnel. A solid nonreverberant mounting position must be selected and passages for ductwork from the outlet spigot, as well as electrical connection, prepared. Compatible ductwork should have already been installed.
5.1.2 Required Tools
- Drill
- PH2 Screwdriver
- Terminal Screwdriver
- Tape Measure
- 100 / 125mm diameter core cutter
5.1.3 Surface Mounted Fan Installation Procedure
- Unpack the fan unit and other components, and ensure that all parts are listed in section “2.4 Box Contents” on page 2. If not please contact the manufacturer for replacement / missing parts.
- Place the front cover and inlet grille to one side.
- Remove the PCB cover by removing 2 off No.6 x 1/2″ screws.
- Partially remove the PCB assembly from the fan casing by placing a fingertip behind the dip switches and pulling the PCB away from the fan casing (Figure 17).
- Disconnect and remove the fan scroll from the assembly and completely remove the PCB assembly. If the pull cord is not required, remove it completely.
- Using the template in section “10.0 DRILL PATTERN TEMPLATE” on page 13, mark out the position of the spigot hole (depending on the spigot size chosen) and the four mounting holes.
- Core cut center and drill and plug mounting holes.
- Choose one of the four cable entries on the fan skirt for the supply wiring and carefully trim out or alternatively feed the cable through the hole in the wall.
- Secure skirt to the wall (fixings supplied by others). Note: use wood screws not countersink screws to avoid distorting the skirt.
- Feed cable through the back of the fan casing and wire cable into the PCB terminal block (see section “4.0 ELECTRICAL INSTALLATION” on page 5).
- Replace PCB into fan casing and secure the cable into place using cable clamps and screws provided in the CYFAN fixing kit.
- Secure unit to skirt using 4 off No.6 x 1/2″ screws provided.
- Replace fan scroll assembly and plug the motor into PCB, replace PCB fully into position by pushing the dip switches.
- Replace PCB cover by fitting with 2 off No.6 x 1/2″ screws.
- Fit front inlet grille using 4 off No.6 x 3/4″ screws found in the fixing kit.
- Remove the rubber gasket and adjust the control to the required settings shown in section “6.0 OPERATION” on page 12. Once required settings are complete and desired airflow rate is achieved replace the rubber gasket.
- Complete the fan installation by fitting (push-fit) the front cover.
5.2 Surface Mounted Installation
5.2.1 Fan Installation
Installation must be completed by qualified personnel. A solid nonreverberant
mounting position must be selected and passages for ductwork from the outlet
spigot, as well as electrical connection, prepared. Compatible ductwork should
have already been installed.
5.2.2 Required Tools
- Drill
- PH2 Screwdriver
- Terminal Screwdriver
- Tape Measure
- 100 / 125mm diameter core cutter
5.2.3 Semi-Recessed Fan Installation Procedure
- Unpack the fan unit and other components, and ensure that all parts are listed in section “2.4 Box Contents” on page 2. If not please contact the manufacturer for replacement / missing parts.
- Place the front cover and inlet grille to one side.
- Remove the PCB cover by removing 2 off No.6 x 1/2″ screws.
- Partially remove the PCB assembly from the fan casing by placing a fingertip behind the dip switches and pulling the PCB away from the fan casing (Figure 20).
- Disconnect and remove the fan scroll from the assembly and completely remove the PCB assembly. If the pull cord is not required, remove it completely.
- Using the template on page 13, mark out the position of the spigot hole (depending on the spigot size chosen) and the four mounting holes.
- For the ceiling, mounting use the Semi-Recessed mounting kit. First cut an aperture for the fan in the ceiling, cut and fit (A) timber supports (not supplied), and fit the fan as shown. Remove the shutters from the spigot if you are mounting CYFAN in the ceiling. Pull-cord must be removed.
- Core cut center and drill and plug mounting holes.
- Choose one of the four cable entries on the fan skirt for the supply wiring and carefully trim out or alternatively feed the cable through the hole in the wall.
- Secure skirt to the wall (fixings supplied by others). Note: use wood screws not countersink screws to avoid distorting the skirt.
- Feed cable through the back of the fan casing and wire cable into the PCB terminal block (see section “4.0 ELECTRICAL INSTALLATION” on page 5).
- Replace PCB into fan casing and secure the cable into place using cable clamps and screws provided in the CYFAN fixing kit.
- Secure unit to skirt using 4 off No.6 x 1/2″ screws provided.
- Replace fan scroll assembly and plug the motor into PCB, replace PCB fully into position by pushing the dip switches.
- Replace PCB cover by fitting with 2 off No.6 x 1/2″ screws.
- Fit front inlet grille using 4 off No.6 x 3/4″ screws found in the fixing kit.
- Remove the rubber gasket and adjust the control to the required settings (see section “6.0 OPERATION” on page 12). Once required settings are complete and desired airflow rate is achieved replace the rubber gasket.
- Complete the fan installation by fitting (push-fit) the front cover.
5.3 Window Mounted Installation
5.3.1 Fan Installation
Window mounting requires the optional mounting kit, Part number: CYFAN-
WKIT.
Installation must be completed by qualified personnel.
5.3.2 Required Tools
- Drill
- PH2 Screwdriver
- Terminal Screwdriver
- Tape Measure
5.3.3 Window Fan Installation Procedure
- Unpack the fan unit and window kit components, and ensure that all parts listed are present (see sections “2.4 Box Contents” on page 2 & “5.3.4 Window Kit Contents” on page 8). If not please contact the manufacturer for replacement / missing parts.
- Place the front cover and inlet grille to one side.
- Remove the PCB cover by removing 2 off No.6 x 1/2″ screws.
- Partially remove the PCB assembly from the fan casing by placing a fingertip behind the dip switches and pulling the PCB away from the fan casing (see “22” on page 8).
- Disconnect and remove the fan scroll from the assembly and completely remove the PCB assembly. Note: if the pull cord is not required, remove it completely.
- Feed wiring flex through the back of the fan casing and secure into place using cable clamps and screws provided in the CYFAN fixing kit.
- Secure the case to the window kit. Note: care must be taken not to twist or distort the case whilst fitting.
- Partially replace PCB into the fan casing and wire flex into the terminal block.
- Replace fan scroll assembly and plug the motor into PCB, replace PCB fully into position by pushing the dip switches.
- Replace PCB cover by fitting with 2 off No.6 x 1/2″ screws.
- Fit front inlet grille using 4 off No.6 x 3/4″ screws found in the fixing kit.
- Remove the rubber gasket and adjust the control to the required settings (see section “6.0 OPERATION” on page 12). Once required settings are complete and desired airflow rate is achieved replace the rubber gasket.
- Complete the fan installation by fitting (push fit) the front cover.
5.3.4 Window Kit Contents
CYFAN-WKIT Checklist
Quantity | Description | Part No. |
---|---|---|
1 off | Window Cover | 041351 |
1 off | Outside Clamp | 041350 |
1 off | Inner Clamp | 041349 |
2 off | Back-draught Shutter | 041286 |
1 off | Screw Kit Containing Shutter Spring | 772285 |
Screw-Kit (772285) Checklist
Quantity | Description | Part No. |
---|---|---|
2 off | No.8 x 1” CSK HD Supascrew | 691646 |
4 off | No.8 x 1-1/2” CSK HD Supascrew | 680193 |
4 off | No.8 x 1-3/4” CSK HD Supascrew | 691647 |
2 off | No.8 x 2-1/4” CSK HD Supascrew | 691648 |
3 off | No.8 x ¾” Panhead Pozi (Main Case to Inner Clamp) | 180394 |
1 off | Spring | 580069 |
5.3.5 Window Kit Installation Procedure
The window kit is designed for mounting the unit into windows 4mm to 32mm thick using a 125mm diameter hole in the glass (Figure 24).
- Employ a qualified glazier to cut a hole 125mm diameter in the glass or, alternatively, replace your window with new glass incorporating a pre-cut hole.
- The outer assembly consists of a cover complete with a clamping plate and an ‘O’ ring seal. The clamping plate incorporates a moulded spigot which is designed to locate inside the 125mm diameter hole in the glass.
- Back draught Shutters (Figures 5 & 25) are clipped into the Inner clamp and the spring is fitted in the lower position).
- Position the assembly on the outside of the glass. If only one person is installing the fan it may be helpful to tape the assembly to the outside glass at this stage during installation as all fixings and assembly are completed from inside.
- Working from inside the room with the clamp. Position this inner clamp over the hole in the glass and line up the 4 mounting holes.
- Select appropriate screws from the screws kit supplied for mounting into different thicknesses of glass, see section “5.3.6 Window Mounting Screws”. Should the screws foul on the back of the grille during installation, replaced with the next size down. There are 2 long and 2 short screws for each thickness of glass with the shorter screws located at the top.
- Using four screws locate the screw bosses in the outer assembly and draw the inner and outer assemblies together. Remove any tape supporting the outer assembly and continue to draw the units together until the ‘O’ ring is compressed on the window. Do not overtighten the fixing screws as this may distort the assembly.
- Wire unit in accordance with the appropriate wiring diagram. A cable clamp is provided inside the case. The remaining installation procedures for Window Mounting are as the description in section “5.3.3 Window Fan Installation Procedure”.
5.3.6 Window Mounting Screws
Window Thickness | Quantity | Screw Size |
---|---|---|
4 – 11 mm | 2 off | No.8 x 1” CSK HD Supascrew |
2 off | No.8 x 1-1/2” CSK HD Supascrew | |
12 – 21 mm | 2 off | No.8 x 1-1/2” CSK HD Supascrew |
2 off | No.8 x 1-3/4” CSK HD Supascrew | |
22 – 32 mm | 2 off | No.8 x 1-3/4” CSK HD Supascrew |
2 off | No.8 x 2-1/4” CSK HD Supascrew |
5.4 Surface Mounted With Side Spigot Installation
CYFAN-DKIT is recommended for Intermittent Extract Only.
5.4.1 Fan Installation
Surface mounting with a side spigot requires the optional mounting kit, part
number: CYFAN-DKIT.
Installation must be completed by qualified personnel. A solid
nonreverberant mounting position must be selected and passages for ductwork
from the outlet spigot, as well as electrical connection, prepared. Compatible
ductwork should have already been installed.
5.4.2 Required Tools
- Drill
- PH2 Screwdriver
- Terminal Screwdriver
- Tape Measure
5.4.3 Spigot Kit Contents
- Replacement Outer Fan Skirt with 50mm diameter hole in one side
- Replacement Fan Body with 55mm diameter hole in each side
- 50mm diameter Spigot
- 3M of 50mm Duct
- Inlet Grille with Filter
- Reduction Filter
5.4.4 Installation Procedure
- Unpack the fan unit and components, and the subsidiary spigot kit. Ensure that all parts are present. If not please contact the manufacturer for replacement / missing parts.
- Place the front cover to one side.
- Place the reduction filter over the grille. Secure the filter by pressing the filter under the lugs located around the grille (Figure 29).
- Remove the PCB cover by removing 2 off No.6 x 1/2″ screws.
- Partially remove the PCB assembly from the fan casing by placing a fingertip behind the dip switches and pulling the PCB away from the fan casing (Figure 30).
- Disconnect and remove the fan scroll from the assembly and completely remove the PCB assembly. if the pull cord is not required, remove it completely.
- If using surface-mounted wiring the 15mm fan skirt must be used, see point 13 onwards.
- Core cut a hole through the mounting surface at the desired mounting position to suit the size of the discharge spigot required, 100mm or125mm diameter.
- Place the fan casing in the mounting position (spigot placed into the core cut hole) and use the base as a template to mark the mounting screw hole positions (x4). Remove casing once marks are made.
- Drill and plug (if necessary) the mounting surface.
- Feed wiring flex through the back of the fan casing and secure into place using cable clamps and screws provided in the CYFAN fixing kit.
- Secure the case to the surface (fixings supplied by others). Care must be taken not to twist or distort the case whilst fitting.
- Partially replace PCB into the new fan casing and wire flex into the terminal block (see section “4.0 ELECTRICAL INSTALLATION” on page 5).
- Whilst utilizing the fan skirt, use the template in section “10.0 DRILL PATTERN TEMPLATE” on page 13 to mark out the position of the spigot hole (depending on spigot size chosen) and the four mounting holes.
- Core cut center and drill and plug mounting holes.
- Choose one of the four cable entries and carefully trim it out.
- Secure skirt to the wall (fixings supplied by others). Use wood screws not countersink screws to avoid distorting the skirt.
- Feed the cable through the skirt and offer up a fan case to the skirt. Feed cable through the unit and secure unit to skirt using 4x No.6 x 1/2″ screws provided.
- Replace fan scroll assembly and plug the motor into PCB, replace PCB fully into position by pushing the dip switches.
- Replace PCB cover by fitting with 2 off No.6 x 1/2″ screws.
- Fit front inlet grille with reduction filter fitted using 4 off No.6 x 3/4″ screws found in the fixing kit.
- Remove the rubber gasket and adjust the control to the required settings (see section “6.0 OPERATION” on page 12). Once required settings are complete and desired airflow rate is achieved replace the rubber gasket.
- Complete the fan installation by fitting (push fit) the front cover.
5.4.5 Setting the Fan for Intermittent Use
The unit should be configured for intermittent use. To achieve 17L/s through
the CYFAN front grille, and 6L/s through the subsidiary spigot the boost speed
control should be set approximately to the 11 O’clock position.
OPERATION
The grille of this unit contains a small magnet, used to confirm the grille is in position prior to the unit operating. If the grille is not fitted or the agent is missing the unit will not operate.
6.1 Default Settings
As default Cyfan units are set as follows:
- Intermittent setting – Fan will only operate from pull-cord or switched live to boost flow rate.
- Continuous running (background ventilation) – OFF
- Humidity sensing – OFF
- Air flow rate (boost) – 15 l/s
- Run-on timer (from switched live only) – 1 minute
6.2 Building Regulations Part F 2010 Flow Rates
Room | Intermittent Extract | Continuous Extract |
---|---|---|
Minimum Rate | Minimum High Rate | **Minimum* Low Rate** |
Kitchen | 30 l/s adjacent to hob; or 60l/s elsewhere. | 13 l/s |
Utility Room | 30 l/s | 8 l/s |
Bathroom | 15 l/s | 8 l/s |
Sanitary Accommodation | 6 l/s | 6 l/s |
*Recommended values, please refer to Part F for further information.
6.3 Continuous / Intermittent Switch
Continuous – Fan running to provide background ventilation. The amount of
airflow can be set between 6 to 30 l/s. Operating the pull cord or remote
switch will boost the fan to the adjustable setpoint available between 8 to
60l/s.
Intermittent – Fan does not operate continuously but only when the pull
cord or remote switch is activated. The amount of airflow is adjustable from 8
to 60 l/s.
6.4 Humidity Tracker Switch
The default setting is off. Switching to ‘ON’ will enable the unit to sense
the humidity in the room. The fan will switch itself on when the humidity
rises above 60% and will slowly speed up as the humidity rises, as per the
example table below.
Relative Humidity| Intermittent Boost Set at 60 l/s|
Intermittent Boost Set at 30 l/s
---|---|---
60%| 20 l/s| 10 l/s
70%| 30 l/s| 15 l/s
80%| 40 l/s| 20 l/s
90%| 50 l/s| 25 l/s
100%| 60 l/s| 30 l/s
6.5 Run-on Timer
The run-on timer is adjustable from 1 to 30 minutes and can operate off a
remote switch (e.g. bathroom light switch).
6.6 Airflow Adjustment
The unit adjustment dials have been set for a unit that has been installed
directly through a wall and with a 125mm spigot. If the 100mm spigot is used
and resistance is placed on the fan (long duct runs) the airflow should be
checked using an appropriate measuring instrument.
MAINTENANCE
It is important that maintenance checks are recorded and that the schedule is
always adhered to, in all cases, the previous report should be referred to.
Before any maintenance or cleaning operation, switch off the fan and
disconnect from the power supply.
7.1 Routine Maintenance
Before any maintenance or cleaning operation, switch off the fan and
disconnect from the power supply.
The push-fit front cover can be removed and cleaned with water and a mild
detergent using a soft cloth and the motor fan assembly can be cleaned with a
dry brush or dry cloth. Any other maintenance or cleaning should be carried
out by properly qualified personnel.
Ensure the unit does not come into contact with any kind of liquid or solvent.
If this should occur, contact a qualified technician before reassembling the
fan.
The motor does not require lubrication as it is of the maintenance-free
“sealed for life” type.
WARRANTY
The 5 year warranty starts from the day of delivery and includes parts and
labor for the first year. The remaining period covers replacement parts only.
This warranty is void if the equipment is modified without authorization, is
incorrectly applied, misused, disassembled, or not installed, commissioned,
and maintained in accordance with the details contained in this manual and
general good practice.
The product warranty applies to the UK mainland and is in accordance with
Clause 14 of our Conditions of Sale. Customers purchasing from outside of the
UK should contact the Nuaire International Sales office for further details.
Failure to maintain the unit as recommended will invalidate the warranty.
END-OF-LIFE AND RECYCLING
Where possible Nuaire uses components that can be largely recycled when the product reaches its end-of-life:
- Fans, motors, controls, actuators, cabling, and other electrical components can be segregated into WEEE recycling streams.
- Sheet metal parts, aluminum extrusion, heating/cooling coils, and other metallic items can be segregated and fully recycled.
- EPP, plastic ducting, nylon corner pieces, plastic heat exchangers, packaging material, and other plastic components can be segregated into mixed plastic and widely recycled.
- Cardboard packaging, wood, used filters and other paper components can be largely recycled or fully processed in energy from waste centers.
- Remaining Items can be further segregated and processed in accordance with the zero waste hierarchy. Please call After-Sales Support for further information on items not listed above.
Ensure that Nuaire product is made safe from any electrical / water/refrigerant supplies before dismantling commences. This work should only be undertaken by a qualified person in accordance with local authority regulations and guidelines, taking into account all site-based risks.
DRILL PATTERN TEMPLATE
AFTER SALES AND REPLACEMENT PARTS
For technical assistance or further product information, including spare parts
and replacement components, please contact the After Sales Department.
If ordering spares please quote the serial number of the unit together with
the part number, if the part number is not known please give a full
description of the part required. The serial number will be found on the
identification plate attached to the unit casing.
Telephone 02920 858 400
aftersales@nuaire.co.uk
Technical or commercial considerations may, from time to time, make it
necessary to alter the design, performance, and dimensions of the equipment,
and the right is reserved to make such changes without prior notice.
NOTES
Installation Manual
CYFAN
Nuaire | Western Industrial Estate | Caerphilly | CF83 1NA |
nuaire.co.uk
18. 02. 21. Document Number 671886