HEYLO HL 800 Virus Air Cleaner User Manual
- October 27, 2023
- HEYLO
Table of Contents
- HL 800 Virus Air Cleaner
- General aspects
- Scope of delivery
- Safety instructions
- Application / fields of operation
- Putting into service / operation
- Filter change (filter installation)
- Cleaning and filter change
- Installation guidelines
- Decommissioning and disposal
- Technical data
- Maintenance / fault finding
- Optional accessories
- Wiring diagram
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
HL 800 Virus Air Cleaner
User Manual
HL 800 Virus Air Cleaner
EC Declaration of Conformity, IIA
In conformity with EC Machinery Directive 2006/42/EC,
For device series: Air cleaner
Typ: HL 800
HEYLO GmbH, Im Finigen 9, 28832 Achim, Germany, declares that, if they are
fitted, maintained and used in conformity with the operating instructions and
the generally accepted engineering standards, the machines mentioned are in
keeping with the fundamental safety and health requirements of the “Machine
Ordinance” as well as with the regulations and standards mentioned
hereinafter.
Applicable EC directives:
Safety of machines: 2006/42/EC
Electromagnetic Compatibility (EMC): 2014/30/EU
RoHS: 2011/65/EU
The declaration loses its validity in case of unauthorized changes to the
machines.
Applied and partially applied standards:
DIN EN 60 335-1
DIN EN 60 335-2-65
Achim, 11.11.2020
General aspects
ATTENTION: Always read before commissioning!
Please carefully follow the instructions in the operating manual. Non-
observance will invalidate the warranty. The manufacturer accepts no liability
for any damage or consequential damage arising from this.
The HL 800 is a mobile air cleaning unit. The air is drawn in from the
environment and passed through a four-stage filtration system. The filter
stages consist of a pre-filter, one 2in1 combination-filters for gases and
particles as well as a plasma generator.
The individual stages have the following functions:
1st stage
Prefilter
A washable plastic filter is used as a pre-filter. The pre-filter filters
coarse dust particles of more than 5 micrometers, such as house dust, scales,
pollen. The filter can be washed out with water and can therefore be used
several times. HEYLO recommends replacing the pre-filter annually.
2nd + 3rd stage (combi-filter).
Carbon filter:
The formaldehyde filter with activated carbon cleans the air from unwanted
odors, gases and substances. It also cleans the air from harmful formaldehyde.
The substances are absorbed by the absorbed by the activated carbon.
Suspension filter: (are not included in the delivery)
Variant 1: H14 filter according to EN1822
HEPA filters of class H14 are used, among other things, in medical areas such
as intensive care units and laboratories, in clean rooms and in other hygienic
areas. For The selection of the filter class depends on the respective
application.
The filters are EN-compliant and certified. H14 filters capture 99.995 % of
all suspended particles from a size of size of 0.1 µm, so that virus filtering
is possible and e.g. coronaviruses are rendered harmless. are rendered
harmless
Variant 2: E11 filter according to EN1822
EPA filters of class E11, are used among other things in living and working
areas such as used. The selection of the filter class depends on the intended
use.
The filters are EN compliant and certified. E11 filters capture 99.5% of all
airborne particles from a size of size of 0.1 µm, so that dust, bacteria and
pollen filtration is possible.
4th stage
Ionization
By applying strong electric fields, ionizers can electrically charge
individual air particles and thus increase the ion concentration in the room
air. The charged particles are more reactive and can thus destroy odour
molecules and other pollutants. At the same time, differently charged
particles attract each other and form larger lumps that sink to the ground
faster and can be filtered out of the air more easily.
Scope of delivery
- 1 x HL 800 filter unit
- 1 x pre-filter
- 1 x remote control
- 1 x instruction manual
Safety instructions
Target group: The manual is intended for the user who sets up and
operates the device.
Copyright: The duplication of the manual in whole or in part is only
permitted with written permission from HEYLO GmbH.
Reservation: HEYLO GmbH reserves the right to make changes and
improvements to the product and manual at any time without prior notice.
Disposal: The device has been designed for many years of operation. If it
has to be disposed of, the competent legal regulations have to be observed in
environmentally gentle manner.
Keep away from children: Do not let children play with or in the vicinity
of the unit.
Electrical connection: The air cleaner HL 800 is designed for operation
with 230 V / 50 Hz. The connection must be fused with 10A.
Use shockproof plugs and shockproof sockets only! The sockets have to be
earthed or protected by residual current circuit-breakers with at least 30
mA..
Protect the power cable from damage: Never use the device with a damaged
power cable. If the power cable is damaged, replace it with a cable of the
same type and dimension.
Extension cables: Only use approved extension cables.
Handle with care: Do not drop or throw the unit, as this may damage
components or wiring. Work on a solid surface: Always place the device on a
solid and plane surface.
Work on a solid surface: Always place the device on a solid and plane
surface.
Keep dry: The device must not be operated in puddles or in standing
water. Do not store or operate outdoors. If the electrical wiring or parts of
the unit get wet, the unit must be thoroughly dried before reusing.
Keep air openings clear: Do not cover or block the air inlets and
outlets.
Environment: Do not use in hazardous areas.
Application / fields of operation
Untreated room air normally contains numerous pathogens. This group includes
mould spores, bacteria, animal hair and above all house dust allergens (mite
faeces, excrements), but also heavy metals, soot and mineral fibres.
Particularly on warm days or during the heating period, large quantities of
these suspended particles develop and are swirled around with the house dust
in the room air. After absorption via the respiratory tract, the particles
then come into contact with our mucous membranes and trigger the known allergy
symptoms.
HEYLO air cleaners can significantly reduce the concentration of these
suspended particles and gases in order to create healthy indoor air.
The devices are typically used in the following areas:
Private apartments, offices, conference and training rooms, schools and public
authorities, surgeries and fitness centres. In all areas where people are
present, the devices can significantly improve air quality. In areas where
pathogens such as bacteria and viruses may be present, the risk of infection
can be reduced.
Putting into service / operation
| To switch the unit on/off, press the power. to start the unit.
You start in automatic mode.
In this operating mode, the motor speed is controlled by a sensor.
The speed of the fan motor is automatically regulated in three stages,
depending on the air quality. The more particles in the air, the higher the
fan motor speed.
To switch off, press the button again and the unit goes into standby mode.
---|---
| Press the “Speed” button to change the fan speed. You can select 3 air
output levels by repeated tapping.
|
With the Mode button you can select 3 programmes
In automatic mode, the unit automatically selects the appropriate fan speed
depending on the air quality. At night, the unit automatically reduces the fan
speed. The ionisation function is in operation.
The turbo programme is useful in case of heavy air pollution, e.g. cigarette
smoke. The unit then runs at the highest fan speed.
Press the “Sleep” button to operate the machine manually at the quietest
level. This ends the automatic mode. All lights and displays are switched off
and the fan runs at the lowest speed. It no longer responds to the air sensor
| When the machine is switched on, you can press the “Timer” button to let the
machine run automatically for a certain period of time. You can select the
time period from 30 minutes to 12 hours. You press the button until the
desired time appears on the display. 5 seconds after the last press, the unit
switches back to the air quality display. (PM2.5 value). To switch off the
timer function again, press the button until none of the hour signals below
the display are lit up.
| Press the “Child Lock” button to activate the child lock. Press and hold the
child lock button for 5 seconds to cancel the function.
| The filter indicator lights up red after 3000 hours of operation.
You should then replace the main filters.
You can reset the display by pressing the button for 3 seconds.
Then the filter timer starts again from the beginning.
|
WIFI function
To turn on the WIFI function, press and hold the mode button for 5 seconds
(without turning on the device).
The WiFi pattern changes to flash status. Now set the mobile phone in pairing
mode. APP and machine are paired. For more information, refer to the WLAN
instructions of the mobile phone.
After the pairing is successful, the WiFi pattern is displayed.
If the machine is in an environment where there is no wireless LAN, the WIFI
icon will not light. After turning on the device, the WiFi icon flashes
slowly.
Only when the WiFi signal is received, the indicator lights up continuously.
The unit can now be operated via the mobile phone in standby and operating
mode.
| Air quality indicator display| PM2.5 Value| Air quality|
Display colour
---|---|---
Smaller 100| Very good| Green
101-200| Good| Blue
201-300| Poor| Orange
➢ 300| Very poor| Red
| Light sensor:
In automatic mode, the product is put into sleep mode when the ambient light
falls below the value <5×. It exits the sleep mode again, after the ambient
light exceeds <5× for 3 minutes and then returns automatic mode
| This product is supplied with a remote control powered by 3V lithium dry
cells. (Please remove the dry cells if you do not use the remote control for a
long period of time). The controls on the user interface on the unit and on
the remote control are directly similar: all functions and operating modes are
basically identical.
Filter change (filter installation)
The main filter change is displayed by the device.
The pre-filters should be cleaned regularly at least once a month.
The filter display flashes every 3000 hours (approx. twice a year).
After changing the HEPA filter, reset the display by pressing the “Filter”
button for 5 seconds.
| Remove the
front cover on both sides.
---|---
| Remove the pre-filters.
Push down the two clips of the pre-filter to remove the pre-filter.
| You can pull the main filter out of the unit by the small clip
NOTE: Please make sure that the retaining strap points outwards.
NOTE: Before first use, the filters must be removed from their protective
packaging
| To clean the air outlet, lift out the grille on the side with the Δ symbol.
Now you can clean the area with a dust cloth.
| Cleaning the air quality sensor
On the back of the device there is a flap behind which the sensor is
installed.
Open the flap and carefully clean the sensor with a cotton swab.
NOTE: you should do this every 2 month or if the display permanently
shows poor quality
Disposal of the filters: The filters can be disposed of in household
waste.
If the unit has been used in polluted air, the used filters must be packed
airtight in bags and disposed of properly. In case of contamination with
viruses, please allow for a waiting period in which the viruses can die off or
wear gloves and protective mask (min. FFP2) when changing the filter.
Cleaning and filter change
Pre-filter:
Pre-filter (coarse dust filter) class G4 according to EN 779
- Pre-filter for the main filters
- Filter for specific large dusts up to 3 µm
- Deposition efficiency 85-98% at 10 µm and 30-55% at 1 µm
- Absorption of coarse dust
Cleaning and filter change:
- The surface can be vacuumed with a vacuum cleaner.
- The filter can also be rinsed with clean water, but it must be completely dry before it is used again.
Cleaning 2 x per month and filter change every 2 years
Optional E11 main filter:
Combination filter of carbon filter and EPA filter E11 according to EN1822
- for suspended matter and particles up to 1 µm
- separation efficiency 99,9%
- suitable for rooms with the highest requirements
filter change once a year
Optional anti-virus filter:
Combination filter of carbon filter and HEPA H14 filter according to EN1822
- for suspended matter and particles up to 1 µm
- separation efficiency 99.995 %
- suitable for rooms with the highest requirements, in laboratories, industry and medicine.
filter change once a year
Ionizer
The ionizer is located inside the unit and cannot be replaced.
The function is normally switched on. To switch off the function, press the
the “Filter key” and the “Mode key” until a sound signal is emitted.
- tone: the function is on
- tones: the function is switched off
Particle sensor
For the air quality display, a sensor measures the particles in the room
air. This sensor should also be cleaned regularly.
To do this, open the flap on the back of the unit (Fig.1) and carefully wipe the sensor clean with a cotton swab.
Installation guidelines
For commercial use, the legal regulations of the respective country must be observed for the installation and use of the HL 800 air cleaner. In Germany the following regulations, among others, must be observed:
- Workplace ordinance §§ 5 and 14
- Workplace directive ASR 5
- Accident prevention regulations VBG 43
- Ordinance on hazardous substances of 01.01.2005
(available from: German Information Centre for Technical Rules (DITR) at DIN,
Burggrafenstraße 6, 10787 Berlin).
HEYLO does not accept any liability for damage which is caused by incorrect
and irregular installation and use of the air cleaner HL 800.
Decommissioning and disposal
HEYLO units have been designed for many years of operation. If it has to be disposed of, the competent legal regulations have to be observed in environmentally-gentle manner The device can be returned to any specialist dealer for disposal free of charge.
Technical data
Type of unit | HL 800 |
---|---|
Air flow rate max. (m³/h) | 800 |
CADR (Clean Air Delivery Rate) (m³/h) | 800 |
CADR in terms of formaldehyde purified air (m³/h) | 300 |
Air flow rate with H14 PTFE Filter max. (m³/h) | 630 |
Anion concentration (mio/cm³)) | 10 |
Air quality display | good (green), average (blue), poor (yellow), very |
Filter type / cleaning method | Prefilter, activated carbon + HEPA filter, |
ionisation
Filter class| EPA / HEPA
Room size EPA E11 (at 5x and 3x air exchange rate) (m²)| 66 / 111
Room size HEPA H14 (at 5x and 3x air exchange rate) (m²)| 53 / 88
Electrical connection (V/Hz)| 230 / 50
Capacity (W)| 90
Noise level min (dB(A) / 3 m)| 33
Noise level max (dB(A) / 3 m)| 42
Cable length (m)| 2
IP class| 20
Length/width/height (mm)| 400 / 400 / 669
Weight (kg)| 14
Attention: The technical data can be changed in the course of further development without prior notice. Some values are approximate values.
Maintenance / fault finding
Warning: Danger of electric shock
The device must be disconnected from the power supply system before any
maintenance work is carried out on it. Electrical components must not be
cleaned with a water hose or pressure washer, as water could penetrate the
electrical component and cause an electric shock.
When dismantling components, please turn the screws by hand to avoid damage
to the threads!
Fault detection and elimination
Problem | Possible reason | Solution |
---|---|---|
The unit does not respond to switch-on | • No power to the device |
• Device does not stand on a plain surface
• Front cover is not closed properly
• Child lock is active| 1. Make sure that the power plug is fully inserted
into the power outlet, then press the power button to turn on the unit
2. Make sure that the front cover is inserted correctly.
3. Make sure that the product is properly installed on a plain surface.
4. When the display shows the child-proof lock, press the “Child-Lock” button
for 5 seconds to deactivate the lock and use the device.
Air is polluted but the display shows clean (green)| Device position is
unfavourable| Position the unit differently so that the air in the room can be
better absorbed.
The air quality display is still very poor (red), even though the product has
been switched on for a long time.| Air sensor is dirty| Clean the particle
sensor with a cotton bud as described in “cleaning and filter change”.
If a strange noise (knocking, chirping) comes out of the device| Ionizer i s
dusty| Clean the ionizer head with a brush as described in section “cleaning
and filter change”.
If the product smells strange| Filter is saturated| 1. Clean the air inlet
opening and internal filter (pre-filter, integrated filter).
2 If you have not replaced the filter for a long time, buy a new filter and
replace it.
If the product does not noticeably improve air quality even after a long
period of operation| • Filter not removed from protective packaging
• Filter not inserted correctly| 1. Make sure that the packaging of the
filter (plastic bag) inside the product has been properly removed
2. Make sure that the order of the filter combination is correct
When the product is switched on and shortly after it is automatically put into sleep mode| Wrong operating mode| Please deactivate the sleep mode (night mode).
Optional accessories
Description | HEYLO item no. |
---|---|
Pre-filter | 1772007 |
Standard main filter (carbon filter / EPA E11) | 1772008 |
Anti-virus filter (carbon filter / HEPA H14) | 1772006 |
Spare remote control | 1772004 |
Battery for Remote control (CR2032) | 1772005 |
Wiring diagram
Do you have any questions? We are happy to help you!
HEYLO Customer Service – Technical Support and Service
Tel. +49 (0) 42 02 – 97 55 15
Fax +49 (0) 42 02 – 97 55 97
E-Mail: service@heylo.de
Commercial advice
Tel. +49 (0) 42 02 – 97 55 – 0
Fax +49 (0) 42 02 – 97 55 97
E-Mail: info@heylo.de
Hire HEYLO products
For your construction site, production facility or event via the HEYLO rental
network:
www.heylo-mietservice.de
HEYLO GmbH
Im Finigen 9
28832 Achim
info@heylo.de
www.heylo.de
Stand: 10/2021
Art.-Nr. 1 960 009