HEYLO 1 200 066 Filter Housing 6000 User Manual

June 6, 2024
HEYLO

HEYLO 1 200 066 Filter Housing 6000

General aspects

CAUTION: Read carefully before starting up!
Please observe the notes in the operating instructions carefully. In case of non-observation, the warranty claims will become void. The manufacturer shall not be liable for any damage and/or consequential damage resulting.

The mobile filter housing is a piece of accessory for the HEYLO axial ventilator PowerVent 6000 (Art.-No. 1110824).
By using coarse of fine dust filters, the mobile filter system can also be used for extracting dust. Dust that does not fall under the Ordinance on Hazardous Substances can be extracted and filter using the filter combination consisting of the pre-filter G4 and the fine dust filter F9. The combination of filter housing incl. dust filter and PowerVent 6000 produces the “Dust Stop” system.

Mounting

Use of the Dust Stop

The Overspray/Dust Stop with the double lip seal (A) is pushed into the hose connection adapter of the PowerVent 6000. That way, a dust-tight connection results between the filter housing and the ventilator PowerVent.

A hose adapter (B) can be mounted to connect a hose to the filter housing.

Dust (Dust filter G4 / F9)

  • Insert filter the same way as with a paint filter
  • Observe direction of air
  • Insert the G4 pre-filter on the suction side.
  • Insert F9 fine dust filter inside (on the ventilator side)
  • Put on the filter cover (C) back again and fix it

CAUTION
When using the optional dust filter, it is absolutely necessary to observe the recommendations of the professional associations in terms of air exchange rates, such as BGR 128 – at least 6- to 8-fold air exchange (HEYLO recommends a 15- to 20-fold air exchange)
The filters must be replaced when the air performance is not sufficient any more.
In case of hazardous substances, intermediate cleaning of the filters is not permissible.

  • Pre-filter: G4 filter according to EN 779
  • Main filter: F9 according to EN 779 / filter class M according to EN 60335

Use / Safety instructions

When using the Overspray/Dust Stop, the following safety instructions have to be observed:

  • Operate the ventilator PowerVent only on suitable sockets with protective conductor.
  • It is absolutely necessary to observe the operating instructions of the “PowerVent 6000” ventilator. www.heylo.de – Downloads / Bedienungsanleitungen
  • Do not draw and filter any potentially explosive gases!
  • Overspray/Dust Stop and PowerVent must not be used in explosive environments.
  • An area exposed to fire hazard (a so-called special area) has to be established in the surrounding area of 5 m of the processing place.
  • Replace filter only by using gloves and eye protection and respiratory protection, if necessary.
  • Dispose of contaminated filter material professionally.
  • Ventilation of the room must always ensure a 5-fold air exchange.
  • Air that is discharged into the atmosphere may contain not more than 3 mg paint solids /m³ exhaust air (value acc. to TA Air).

Installation guidelines

The legal regulations of the respective country have to be observed for the installation and use of the Dust Stop. In Germany, the following regulations have to be observed among others:

  • German Workplace Ordinance: Section (5) and (14)
  • German Workplace Regulations: ASR 5
  • Accident Prevention Regulations: VBG 43
  • Ordinance on Hazardous Substances: OHS
  • Technical Rules: RBS 1203
  • Trade Association Regulations and Rules: BGI 740 , BGR 128, BGR 132, BGR 231, BGR 500
  • Standards: EN 12215, EN 13355, EN 13463-1 to 8
  • Information on explosion protection: TRBS 1203

HEYLO does not accept any liability for damage which is caused by incorrect and irregular installation and use of the Dust Stop and the PowerVent 6000.
Decommissioning and disposal of the unit
HEYLO units have been designed for many years of operation. If it has to be disposed of, the competent legal regulations have to be observed in environmentally-gentle manner.

Technical data

Model Overspray / Dust Stop
Dimensions (Height x Width x Depth) 690 x 640 x 445 mm
Filter size 600 x 600 mm

Air performance in combination with PowerVent 6000 Ventilator


Weight

| 3.400 m³/h (in case of free dust filter package: Pre-filter G4 + main filter F9 correspond to M class)

20kg

Accessories (spare parts / consumables)

  • Course dust filter G4 (set of 3) (Art. No. 1 110 949)
  • Fine dust filter F9 (Art. No. 1 110 885)
  • Hose adapter Ø 420 mm (Art. No. 1 200 068)
  • Air hose (Pressure) Ø 420 mm, 7.6 m (Art. No. 1 250 073)
  • Air hose (Suction) Ø 420 mm, 7.6 m (Art. No. 1 250 004)

Do you have any questions? Don’t hesitate to contact us!

HEYLO customer service

Tel. +49 (0) 42 02 – 97 55 15
Fax +49 (0) 42 02 – 97 55 97
Email service@heylo.de

HEYLO products

HEYLO bietet das komplette Programm an mobilen Luftsystemen für Bau, Industrie und Gewerbe. HEYLO provides the complete program of mobile air systems for construction, industry and craft.

HEYLO tip

Do you already know our cleaning range
“HEYLO POWER CLEAN”? Use the metal cleaner in combination with the air disinfectant spray for cleaning finned heat exchangers.HEYLO-1-200-066
-Filter-Housing-6000-fig5

Devices notes

  • Device No.
  • Delivery Date
  • Other

HEYLO GmbH Im Finigen 9 28832 Achim info@heylo.de www.heylo.de

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals