HEYLO HL 800 Design-Air Cleaner User Manual

June 10, 2024
HEYLO

HEYLO HL 800 Design-Air Cleaner

Heylo HL 800 Air Purifier

User Manual

General Information:

The Heylo HL 800 Air Purifier is a design-air cleaner that should be installed, maintained and used in accordance with recognized technical rules, basic safety and health requirements of the “Machinery Directive” as well as the provisions and standards mentioned below:

Applicable EU Directives:

  • Machinery Directive 2006/42/EC
  • Low Voltage Directive 2014/35/EU
  • EMC Directive 2014/30/EU

Applied Standards:

  • DIN VDE 0700 Part 1 and Part 30
  • DIN EN 55014-1:2012-05
  • DIN EN 60 335-1
  • DIN EN 60 335-2-69

Date: 10/2021 Art.-Nr. 1 960 007+1 960 009

Delivery Contents:

  • Air Purifier unit (HL 800)
  • User Manual (in German and English)

Safety Instructions:

  • Read the user manual carefully before using the air purifier.
  • Keep the air purifier away from children and pets.
  • Do not touch the air purifier with wet hands or feet.
  • Do not try to repair or disassemble the air purifier yourself. Contact a qualified technician in case of any problems.
  • Do not use the air purifier if the power cord or plug is damaged or if the air purifier is damaged in any other way.
  • Target group : The manual is intended for the user who sets up and operates the device.
  • Copyright : The duplication of the manual in whole or in part is only permitted with written permission from HEYLO GmbH.
  • Reservation : HEYLO GmbH reserves the right to make changes and improvements to the product and manual at any time without prior notice.
  • Disposal : The device has been designed for many years of operation. If it has to be disposed of, the competent legal regulations have to be observed in environmentally gentle manner.
  • Keep away from children : Do not let children play with or in the vicinity of the unit.
  • Electrical connection : The air cleaner HL 800 is designed for operation with 230 V / 50 Hz. The connection must be fused with 10A.  Use shockproof plugs and shockproof sockets only! The sockets have to be earthed or protected by residual current circuit-breakers with at least 30 mA..
  • Protect the power cable from damage : Never use the device with a damaged power cable. If the power cable is damaged, replace it with a cable of the same type and dimension.
  • Extension cables : Only use approved extension cables.
  • Handle with care : Do not drop or throw the unit, as this may damage components or wiring. Work on a solid surface: Always place the device on a solid and plane surface.
  • Work on a solid surface : Always place the device on a solid and plane surface.
  • Keep dry : The device must not be operated in puddles or in standing water. Do not store or operate outdoors. If the electrical wiring or parts of the unit get wet, the unit must be thoroughly dried before re-using.
  • Keep the air openings free : Do not cover or block the air inlets and outlets.
  • Environment : Do not use in hazardous areas.

Application/Usage Areas:

The air purifier is suitable for use in private households, offices, and other indoor areas with normal air quality. Untreated room air normally contains numerous pathogens. This group includes mould spores, bacteria, animal hair and above all house dust allergens (mite faeces, excrements), but also heavy metals, soot and mineral fibres. Particularly on warm days or during the heating period, large quantities of these suspended particles develop and are swirled around with the house dust in the room air. After absorption via the respiratory tract, the particles then come into contact with our mucous membranes and trigger the known allergy symptoms. HEYLO air cleaners can significantly reduce the concentration of these suspended particles and gases in order to create healthy indoor air. The devices are typically used in the following areas: Private apartments, offices, conference and training rooms, schools and public authorities, surgeries and fitness centres. In all areas where people are present, the devices can significantly improve air quality. In areas where pathogens such as bacteria and viruses may be present, the risk of infection can be reduced.

Operating Instructions:
To operate the air purifier, follow these steps:

  1. Place the air purifier on a stable and level surface.
  2. Plug the air purifier into a wall socket.
  3. Press the power button to turn on the air purifier. The air purifier will start running on low fan speed by default.
  4. Press the fan speed button to adjust the fan speed to your desired level (low, medium or high).
  5. The air purifier also features a light sensor which enables it to automatically enter sleep mode when ambient light levels are low, such as during nighttime hours.

WIFI Function:
The air purifier comes with a WIFI feature that enables remote control via a mobile device, using the Heylo app. To use this feature:

  1. Download and install the Heylo app on your mobile device.
  2. Connect your mobile device to the same WIFI network as the air purifier.
  3. Open the Heylo app and follow the instructions to connect to the air purifier.

Air Quality Indicator:
The air purifier features an LED indicator system that reflects the current air quality in the room:

PM2.5 Value Indicator Color
Less than 100 Green
101-200 Orange
201-300 Red
Greater than 300 Dark Red

General aspects

ATTENTION: Always read before commissioning!

Please carefully follow the instructions in the operating manual. Non- observance will invalidate the warranty. The manufacturer accepts no liability for any damage or consequential damage arising from this.

The HL 800 is a mobile air cleaning unit. The air is drawn in from the environment and passed through a four-stage filtration system. The filter stages consist of a pre-filter, one 2in1 combination-filters for gases and particles as well as a plasma generator. The individual stages have the following functions:

1st stage
Prefilter A washable plastic filter is used as a pre-filter. The pre-filter filters coarse dust particles of more than 5 micrometers, such as house dust, scales, pollen. The filter can be washed out with water and can therefore be used several times. HEYLO recommends replacing the pre-filter annually.

2nd + 3rd stage
Effective formaldehyde filter The formaldehyde filter with activated carbon cleans the air of unwanted odours, gases and substances. It also cleans the air of harmful formaldehyde in a very short time. The substances are absorbed by the activated carbon and when the filter is saturated, it must be replaced. HEYLO recommends this every 6 months. In case of strong odour pollution, such as cigarette smoke, a more frequent change may also be advisable. Highly efficient HEPA filter (suspended matter filter) The HEPA filter filters airborne germs, smoke, and dust particles down to 1µm in size at a rate of 99% or more. In combination with the multifunctional filter, the HEPA filter can filter out microscopic particles with a diameter of more than 20 nanometres, including bacterial mould, dust, allergens, and some viruses. According to the World Health Organisation, the corona virus, avian flu virus, influenza virus and legionella bacteria are larger than 20 nanometres

4th stage
Ionization By applying strong electric fields, ionizers can electrically charge individual air particles and thus increase the ion concentration in the room air. The charged particles are more reactive and can thus destroy odour molecules and other pollutants. At the same time, differently charged particles attract each other and form larger lumps that sink to the ground faster and can be filtered out of the air more easily.

Scope of delivery

  • 1 x air cleaner HL 800
  • 1 x pre-filter
  • 1 x main filter as combination filter
  • 1 x remote control
  • 1 x instruction manual

Putting into service / operation

OVERVIEW

Filter change (filter installation)

  • The main filter change is displayed by the device.
  • The pre-filters should be cleaned regularly at least once a month.
  • The filter display flashes every 3000 hours
  • After changing the HEPA filter, reset the display by pressing the “Filter” button for 5 seconds.

Disposal of the filters :
The filters can be disposed of in household waste. If the unit has been used in polluted air, the used filters must be packed airtight in bags and disposed of properly. In case of contamination with viruses, please allow for a waiting period in which the viruses can die off or wear gloves and protective mask (min. FFP2) when changing the filter.

Cleaning and filter change

Pre-filter

pre-filter (coarse dust filter)

  • Pre-filter for the main filters
  • Filter for specific large dusts up to 3 µm
  • Deposition efficiency 85-98% at 10 µm and 30-55% at 1 µm
  • Asorption of coarse dust

Cleaning and filter change:

  • The surface can be vacuumed with a vacuum cleaner.
  • The filter can also be rinsed with clean water, but it must be completely dry before it is used again.
Main filter standard

Combination filter of carbon filter and EPA filter E11 according to EN1822

  • for suspended matter and particles up to 1 µm
  • separation efficiency 99,9%
  • suitable for rooms with the highest requirements

Cleaning and filter change:
The surface can be carefully vacuumed with a vacuum cleaner.

Optional anti-virus filter:
Combination filter of carbon filter and HEPA H14 filter according to EN1822

  • for suspended matter and particles up to 1 µm
  • separation efficiency 99.995 %
  • suitable for rooms with the highest requirements, in laboratories, industry and medicine.

Cleaning and filter change:
The surface can be carefully vacuumed with a vacuum cleaner.

Ionizer
The Ionizer is located inside the unit and cannot be replaced. The function is normally switched on. To switch the function off, press The “filter button” and the “mode button” until you hear an acoustic signal.

  1. tone : the function is on
  2. beeps : the function is switched off

Particle sensor
For the air quality display, a sensor measures the particles in the room air. This sensor should also be cleaned regularly.

To do this, open the flap on the back of the unit (Fig.1) and carefully wipe the sensor clean with a cotton swab.

Installation guidelines

For commercial use, the legal regulations of the respective country must be observed for the installation and use of the HL 800 air cleaner. In Germany the following regulations, among others, must be observed:

  • Workplace ordinance §§ 5 and 14
  • Workplace directive ASR 5
  • Accident prevention regulations VBG 43
  • Ordinance on hazardous substances of 01.01.2005

(available from: German Information Centre for Technical Rules (DITR) at DIN, Burggrafenstraße 6, 10787 Berlin). HEYLO does not accept any liability for damage which is caused by incorrect and irregular installation and use of the air cleaner HL 800.

Decommissioning and disposal

HEYLO units have been designed for many years of operation. If it has to be disposed of, the competent legal regulations have to be observed in environmentally-gentle manner The device can be returned to any specialist dealer for disposal free of charge.

Technical data

Type of unit HL 800
Air flow rate max. (m³/h) 800
CADR (Clean Air Delivery Rate) (m³/h) 800
CADR in terms of formaldehyde purified air (m³/h) 300
Air flow rate with H14 PTFE Filter max. (m³/h) 630
Anion concentration (mio/cm³)) 10
Air quality display good (green), average (blue), poor (yellow), very poor

(red)
Filter type / cleaning method| Prefilter, activated carbon + HEPA filter, ionisation
Filter class| EPA / HEPA
Room size EPA 11 (at 5x and 3x air exchange rate) (m²)| 66 / 111
Room size
HEPA 14 (at 5x and 3x air exchange rate) (m²)| 53 / 88
Electrical connection (V/Hz)| 230 / 50
Capacity (W)| 90
Noise level min (dB(A) / 3 m)| 33
Noise level max (dB(A) / 3 m)| 42
Cable length (m)| 2
IP class| 20
Length/width/height (mm)| 400 / 400 / 669
Weight (kg)| 14

Attention: The technical data can be changed in the course of further development without prior notice. Some values are approximate values.

Maintenance / fault finding

Warning : Danger of electric shock The device must be disconnected from the power supply system before any maintenance work is carried out on it. Electrical components must not be cleaned with a water hose or pressure washer, as water could penetrate the electrical component and cause an electric shock. When dismantling components, please turn the screws by hand to avoid damage to the threads! Fault detection and elimination

Problem Possible reason Solution
The unit does not respond to switch-on §  No power to the device

§  Device does not stand on a plain surface

§  Front cover is not closed properly

§  Child lock is active

| 1.   Make sure that the power plug is fully inserted into the power outlet, then press the power button to turn on the unit

2.   Make sure that the front cover is inserted correctly.

3.   Make sure that the product is properly installed on a plain surface.

4.  When the display shows the child-proof

lock, press the “Child-Lock” button for 5 seconds to deactivate the lock and use the

device.

Air is polluted but the display shows clean

(green)

| Device position is unfavourable| Position the unit differently so that the air in the room can be better absorbed.
The air quality display is still very poor (red), even though the product has been switched on for a

long time.

| Air sensor is dirty| Clean the particle sensor with a cotton bud as described in “cleaning and filter change”.
If a strange noise (knocking, chirping)

comes out of the device

| Ionizer i s dusty| Clean the ionizer head with a brush as described in section “cleaning and filter

change”.

If the product smells strange| Filter is saturated| 1. Clean the air inlet opening and internal filter (pre-filter, integrated filter).

2 If you have not replaced the filter for a

long time, buy a new filter and replace it.

If the product does not noticeably improve air quality even after a long period of operation| §  Filter not removed from protective packaging

§  Filter not inserted correctly

| 1.   Make sure that the packaging of the filter (plastic bag) inside the product has been properly removed

2.   Make sure that the order of the filter combination is correct

When the product is switched on and shortly after it is automatically put

into sleep mode

| Wrong operating mode| Please deactivate the sleep mode (night mode).

Optional accessories

Description HEYLO item no.
Pre-filter 1772001
Standard main filter (carbon filter / EPA H11) 1772002
Anti-virus filter (carbon filter / HEPA H14) 1772003
Spare remote control 1772004
Battery for Remote control (CR2032) 1772005

Wiring diagram

HEYLO Customer Service – Technical Support and Service

  • Tel. +49 (0) 42 02 – 97 55 15
  • Fax +49 (0) 42 02 – 97 55 97
  • E-Mail : service@heylo.de

HEYLO GmbH Im Finigen 9 28832 Achim

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals