REGENCY F180B-1 Renmark Freestanding Wood Fire Owner’s Manual
- June 6, 2024
- Regency
Table of Contents
Owners & Installation Manual
RENMARK FREESTANDING WOOD FIRE
Model: F180B-1
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
WARNING: Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. Refer to this manual. For
assistance or additional information consult an authorized installer, service
agency or the distributor.
FOR YOUR SAFETY Do not store or use petrol or other flammable vapours and
liquids in the vicinity of this or any other appliance. Installation and
service must be performed by an authorized installer, service agency or the
gas supplier.
Thank you for purchasing a
REGENCY FIREPLACE PRODUCT.
The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the REGENCY DEALER in your area.
Keep those REGENCY FIRES burning.
SAFETY NOTE: If this wood fire is not properly installed, a house fire may result. For your safety, follow the installation instructions, contact local building, fire officials, or authority having jurisdiction about restrictions and installation inspection requirements in your area. The authority having jurisdiction should be consulted before installation to determine the need to obtain a permit.
WARNING!
HOT GLASS WILL CAUSE BURNS
DO NOT TOUCH GLASS UNTIL COOLED
NEVER ALLOW CHILDREN TO TOUCH GLASS
SAFETY LABEL
This is a copy of the label that accompanies each F180B-1 Freestanding Wood Fire. We have printed a copy of the contents here for your review.
NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
UNIT DIMENSIONS
INSTALLATION
RESIDENTIAL INSTALLATION
- Please read this entire manual before you install and use your new wood fire. Failure to follow instructions may result in property damage, bodily injury, or even death. Be aware that local Codes and Regulations may override some items in this manual. Check with your local inspector.
- THE APPLIANCE AND FLUE SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH AS/NZS 2918:2001 AND THE APPROPRIATE REQUIREMENTS OF THE RELEVANT BUILDING CODE OR CODES. APPLIANCES INSTALLED IN ACCORDANCE WITH THIS STANDARD SHALL COMPLY WITH THE REQUIREMENTS OF AS/NZS 4013 WHERE REQUIRED BY THE REGULATORY AUTHORITY. ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED TO BE IN BREACH OF THE APPROVAL GRANTED FOR COMPLIANCE WITH AS/NZS 4013. CAUTION: MIXING OF APPLIANCE OR FLUE-SYSTEM COMPONENTS FROM DIFFERENT SOURCES OR MODIFYING THE DIMENSIONAL SPECIFICATION OF COMPONENTS MAY RESULT IN HAZARDOUS CONDITIONS. WHERE SUCH ACTION IS CONSIDERED, THE MANUFACTURER SHOULD BE CONSULTED IN THE FIRST INSTANCE.
- Select a position for your Regency Stove. Consult the minimum clearance chart for your model and set the stove in place. For close clearance installation use listed double-wall connector systems.
- To insure vertical alignment, suspend a plumb bob from the ceiling over the exact center of your stove flue and mark a spot on the ceiling to indicate the center of the chimney.
- Check that the area above the ceiling is clear for cutting. Re-confirm the clearance from the stove to combustibles to insure that they are within the prescribed limits.
- Mark the location of the pedestal base on the floor, then move the stove aside and mark the position of the floor protector.
- Install chimney according to chimney manufacturers instructions. The performance of your wood fire is governed to a very large part by the chimney system. Too short a chimney can cause difficult start-up, dirty glass, backsmoking when door is open, and even reduced heat output. Too tall a chimney may prompt excessive draft which can result in very short burn times and excessive heat output.
- The floor protector must be of non-combustible material. Refer to page 7 for floor protector clearances.
- When the floor protection is complete, position the stove with the flue collar centered under the installed chimney.
- In seismically active areas, Regency recommends that your unit is secured to the floor by using the bolt down holes inside the pedestal.
- Do not connect this unit to a chimney serving another appliance.
SAFETY GUIDELINES AND WARNINGS
- Never use petrol, petrol-type lantern fuels, kerosene, charcoal lighter fuel, or similar liquids to start or `freshen up’ a fire in your heater. Keep all such liquids well away from the heater while it is in use.
- Keep the door closed during operation and maintain all seals in good condition.
- Do not burn any quantities of paper, garbage, and never burn flammable fluids such as petrol, naptha, or engine oil in your stove.
- If you have smoke detectors, prevent smoke spillage as this may set off a false alarm.
- Do not overfire heater. If the chimney connector, flue baffle, or the stove top begin to glow, you are overfiring. Stop adding fuel and close the draft control. Overfiring can cause extensive damage to your stove including warpage and premature steel corrosion. Overfiring will void your warranty.
- Do not permit creosote or soot build-up in the chimney system. Check and clean chimney at regular intervals. Failure to do so can result in a serious chimney fire.
- Your Regency stove can be very hot. You may be seriously burned if you touch the stove while it is operating, keep children, clothing, and furniture away. Warn children of the burn hazard. For safety reasons a guard around the fire is recommended.
- The stove consumes air while operating, provide adequate ventilation with an air duct, or open a window while the stove is in use.
- Do not connect this unit to a chimney flue serving another appliance.
- Do not use grates or andirons or other methods for supporting fuel. Burn directly on the base or bricks where supplied.
- Open the draft control fully for 10 to 15 seconds prior to slowly opening the door when refuelling the fire.
- Do not connect your unit to any air distribution duct.
- Your wood fire should burn dry, standard firewood only. The use of cut timber, plywood, “mill ends”, etc. is not allowed as this fuel can easily overheat your wood fire. Evidence of excessive overheating will void your warranty. As well, a large portion of sawmill waste is chemically treated timber, which is illegal to burn in many areas. Salt drift wood and chemically treated fire logs also must not be burned in your wood fire.
- No combustible material should be closer than the clearances as specified on page 7.
- DO NOT OPERATE WITH BROKEN GLASS.
BRICK INSTALLATION
Firebrick comes installed in each stove and is made to extend the life of your stove and to radiate heat more evenly. Important: Remove the packing material from above and below the top bricks. Check to see that all firebricks are in their correct positions and have not become misaligned during shipping.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS **
**
| Flo-Met Super Single (1)| Hawkwind Standard (2)
Default Kit| *AHD Special Insulated (3)**
---|---|---|---
A| 450mm| 400mm| 450mm
B| 200mm| 100mm| 100mm
C| 325mm| 175mm| 175mm
D| 158mm| 100mm| 100mm
E| 120mm| 120mm| 120mm
F| 450mm| 350mm| 350mm
G| 880mm| 880mm| 880mm
H| 1105mm| 914mm| 914mm
Floor Protection
A combustible floor must be protected by non-combustible material (like tile,
concrete board, or as defined by local codes) extending beneath the heater as
follows;
From Sides: | Refer to Dimension E |
---|---|
From Front: | Refer to Dimension F |
From Back: | Refer to Dimension B |
The floor protector should consist of 12mm thick cement fibre sheet which has a thermal resistance of 0.8m 2 k/w for 4mm sheets of cement fibre sheet.
IMPORTANT
- The Flo-Met Super Single flue kit must be installed with a 130 x 900mm stainless reflective shield between deco mesh and active flue plus an additional 900mm x 130o stainless shield positioned 20mm behind deco mesh directly on top of the appliance.
- The Hawkwind Standard flue kit requires a 130o x 900mm stainless reflective shield between the decromesh casing and active flue. If no additional shielding is added to the Standard default Hawkwind kit the rear wall clearance is 325mm.
- The AHD Special Insulated flue kit must be installed with a 40mm air gap around the flue to any combustible surfaces and the ceiling ring must be spaced as such to provide an air gap of 20mm to the ceiling. An additional 130º x 900mm stainless shield must be positioned 25mm behind the active flue – directly on top of the appliance.
The flue pipe shall extend not less than 4.6m above the top of the floor
protector.
NOTE: Installation must be carried out by a licensed installer in
accordance with AS/NZS 2918:2001.
NOTE: A minimum clearance of 125mm (flat wall) or 150mm (corner wall) must be retained for all wall surfaces to allow for fan access and maintenance.
OPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS
With your unit now correctly installed and safety inspected by your local authority, you are now ready to start a fire. Before establishing your first fire, it is important that you fully understand the operation of your draft control.
CAUTION: THIS APPLIANCE MUST BE MAINTAINED AND OPERATED AT ALL TIMES IN
ACCORDANCE WITH THESE INSTRUCTIONS.
CAUTION: THE USE OF SOME TYPES OF PRESERVATIVE-TREATED WOOD AS A FUEL CAN
BE HAZARDOUS.
WARNING: ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN
WRITING BY THE TESTING AUTHORITY IS CONSIDERED AS BREACHING AS/NZS 4013.
WARNING: DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS TO START OR REKINDLE
THE FIRE.
WARNING: DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS IN THE VICINITY OF THIS
APPLIANCE WHEN IT IS OPERATING.
WARNING: DO NOT STORE FUEL WITHIN HEATER INSTALLATION CLEARANCES.
WARNING: OPEN AIR CONTROL (AND DAMPER WHEN FITTED) BEFORE OPENING FIRING
DOOR.
For safety reasons and in order to avoid over firing of your unit do not burn
your fire with the door open or ajar.
AIR SLIDE CONTROL
Both the primary and air wash drafts are controlled by the control rod located on the right side of the unit (when facing the unit). To increase your raft pull open, and to decrease push closed. All units have a secondary draft system that continually allows combustion air to the induction ports at the top of the firebox, just below the flue baffle.
WARNING: To build a fire in ignorance or to disregard the information contained in this section can cause serious permanent damage to the unit and void your warranty!!
FIRST FIRE
When your installation is completed and inspected you are ready for your first fire.
-
Open control fully.
-
Open firebox door and build a small fire using paper and dry kindling on the firebox base. Secure door on the firebox and wait a few minutes for a good updraft in the flue to establish the fire. (Leaving the door slightly open will help your fire start more rapidly.)
CAUTION: Never leave unit unattended if door is left open. This procedure is for fire start-up only, as unit may overheat if door is left open for too long. -
With the draft still in the fully open position add two or three seasoned logs to your fire. Form a trench in the ash bed to allow air to reach the rear of the firebox prior to closing the door.
-
After about 45 minutes, when your wood has begun to burn strongly, adjust your draft control down to keep the fire at a moderate level. WARNING: Never build a roaring fire in a cold stove. Always warm your stove up slowly!
-
Once a bed of coals has been established on the base of the firebox, you may adjust the draft control to a low setting to operate the unit at its most efficient mode.
-
During the first few fires, keep the combustion rate at a moderate level and avoid a large fire. Only after 5 or 6 such fires can you operate the stove at its maximum setting, and only after the metal has been warmed.
-
For the first few days, the stove will give off an odour from the paint. This is to be expected as the high-temperature paint becomes seasoned. Windows and/or doors should be left open to provide adequate ventilation while this temporary condition exists. Burning the stove at a very high temperature the first few times may damage the paint. Burn fires at a moderate level the first few days.
-
Do not place anything on the stovetop during the curing process. This may result in damage to your paint finish.
-
During the first few days, it may be more difficult to start the fire. As you dry out your firebrick and your masonry flue, your draft will increase.
-
For those units installed at higher elevations or into sub-standard masonry fireplaces, drafting problems may occur. Consult an experienced dealer or mason on methods of increasing your draft.
-
Some cracking and popping noises may be experienced during the heating-up process. These noises will be minimal when your unit reaches temperature.
-
Before opening your door to reload, open draft fully for approximately 10 to 15 seconds until fire has been re-established. This will minimize any smoking.
-
All fuel-burning appliances consume oxygen during operation. It is important that you supply a source of fresh air to your unit while burning. A slightly opened window is sufficient for the purpose. If you also have a fireplace in your home, a downdraft may be created by your Regency Stove causing a draft down your chimney. If this occurs, slightly open a window near your unit.
CAUTION: If the body of your unit, flue baffle, or any part of the chimney connector starts to glow, you are overfiring. Stop loading fuel immediately and close the draft control until the glow has completely subsided. -
Green or wet wood is not recommended for your unit. If you must add wet or green fuel, open the draft control fully until all moisture has been dispersed by the intense fire. Once all moisture has been removed, the draft control may be adjusted to maintain the fire.
-
If you have been burning your stove on a low draft, use caution when opening the door. After opening the damper, open the door a crack, and allow the fire to adjust before fully opening the door.
-
The controls of your unit or the air supply passages should not be altered to increase firing for any reason.
-
If you burn the unit too slowly or at too low a setting your unit will not be operating as efficiently as it can. An easy rule of thumb says that if your glass is clean, then your flue is clean and your exhaust is clean. Burn the stove hot enough to keep your glass clean and you won’t need to clean your flue as often.
MAINTENANCE
CREOSOTE
When wood is burned slowly, it produces tar and other organic vapours, which when combined with moisture, form creosote. The creosote vapours condense in the relatively cool chimney flue of a slow-burning fire. As a result, creosote residue accumulates on the flue lining. When ignited, this creosote can result in an extremely hot fire.
WARNING: Things to remember in case of a chimney fire:
- Close all draft and damper controls.
- CALL THE FIRE DEPARTMENT.
Ways to Prevent and Keep Unit Free of Creosote
- Burn stove with the draft control wide open for about 10-15 minutes every morning during burning season.
- Burn stove with draft control wide open for about 10 – 15 minutes every time you apply fresh wood. This allows the wood to achieve the charcoal stage faster and burns up any unburned gas vapours which might otherwise be deposited within the system.
- Only burn seasoned wood! Avoid burning wet or greenwood. Seasoned wood has been dried at least one year.
- A small hot fire is preferable to a large smouldering one that can deposit creosote within the system.
- The chimney and chimney connector should be inspected at least once every two months during the heating season to determine is a creosote buildup has occurred.
- Have chimney system and unit cleaned by competent chimney sweeps twice a year during the first year of use and at least once a year thereafter or when a significant layer of creosote has accumulated (3 mm/1/8″ or more) it should be removed to reduce the risk of a chimney fire.
WOOD STORAGE
Store wood under cover, such as in a shed, or covered with a tarp, plastic, tar paper, sheets of scrap plywood, etc., as uncovered wood can absorb water from rain or snow, delaying the seasoning process.
MAINTENANCE
It is very important to carefully maintain your fireplace stove, including burning seasoned wood and maintaining a clean stove and chimney system. Have the chimney cleaned before the burning season and as necessary during the season, as creosote deposits may build up rapidly. Moving parts of your stove require no lubrication.
GLASS MAINTENANCE
Your Regency stove is supplied with 5 mm Neoceram ceramic glass that will
withstand the highest heat that your unit will produce. In the event that you
break your glass by impact, purchase your replacement from an authorized
Regency dealer only, and follow our step-by-step instructions for replacement.
Allow the stove to cool down before cleaning the glass, do not clean the glass
when it is hot. Do not use abrasive cleaners.
DOOR LATCH ADJUSTMENT
The door latch may require adjustment as the door gasket material compresses
over time.
Follow the steps below to allow the latch to be moved closer to the door
frame, causing a tighter seal;
- Unscrew latching sleeve.
- Remove Allen screw.
- Spin door handle clockwise to desired depth.
- Re-install allen screw and latching sleeve.
- Adjust set screw to proper depth to ensure that the handle does not rotate 360 degrees.
Rear View of Door shown
PARTS LIST
STOVE ASSEMBLY
| Part #| Description
---|---|---
1)| F180-917| Fan Assembly (optional)
3)| 1154202| Back Shield
4)| 8010107| Air Slide
5)| 1141704| Firebrick Retaining Bracket
6)| 8010108| Firebrick Set
7)| 1143200| Pedestal
8)| 8010102| Ash Lip Panel
10)| 8010110| Door Assembly (without handle)
11)| 8010114| Door Handle Sets
12)| 8010106| Glass Neoceram w/Gasket
13)| 1154400| Heat Shield L
14)| 1154500| Heat Shield R
15)| 8010201
8010104
8010611
7510206| Top Panel
Stainless Steel Air Bar
Steel Baffle (optional) (A)
Cast Plate Set (optional) (B)
16)| 8010115| Glass Retainer Bracket
17)| 8010113| Metal lip inside firebox
18)| 936-233| Door rope seal 5 ft. (not shown)
WARRANTY
Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. Fireplace Products Australia Pty. Ltd. is pleased to extend this warranty to the original purchaser of a Regency Product. This warranty is not transferable.
The Warranty:
Covered under the agreement against manufacturer’s defects from the date of
purchase are the following components:
The Firebox for 10 years;
Steel Baffles for 12 months;
Cast Iron Liners / Baffles for 2 years;
Electrical components (ie. fans, switches) for 12 months.
The above will be covered for parts as noted above (exception of wood-burning
appliances – see below) with labour coverage for one year from date of
purchase.
Regency Fireplace Products is not liable for freight or labour on any wood
burning appliance replaced in field.
Repair/replacement parts purchased by the consumer from Regency Fireplace
Products after the original coverage has expired on the unit will carry a
90-day warranty, valid with a receipt only. Any item shown to be defective
will be repaired or replaced at our discretion. No labour coverage is included
with these parts.
Conditions:
Any part or parts of this unit which in our judgement show evidence of such
defects will be repaired or replaced at Regency Fireplace Product’s option,
through an accredited distributor or agent provided that the defective part be
returned to the distributor or agent Transportation Prepaid if requested. In
areas where there is not an approved service agent or the closest approved
service agent is situated more than thirty (30) kilometers from the
installation, Regency is not obliged to arrange warranty repairs and travel,
and/or additional labour charges will apply.
It is the general practice of Regency Fireplace Products to charge for larger,
higher-priced replacement parts and issue credit once the replaced component
has been returned to Regency Fireplace Products and evaluated for manufacturer
defect.
The authorised selling dealer is responsible for all in-field service work
carried out on your Regency product. Regency Fireplace Products will not be
liable for results or costs of workmanship from unauthorised service persons
or dealers.
At all times Regency Fireplace Products reserves the right to inspect product
in the field which is claimed to be defective.
All claims must be submitted to Regency Fireplace Products by authorized
selling dealers. It is essential that all submitted claims provide all of the
necessary information including customer name, purchase date, serial #, type
of unit, problem, and part or parts requested, without this information the
warranty will be invalid.
Exclusions:
This warranty does not extend to or include paint, door or glass gasketing,
neo-ceramic glass, firebrick, or trim. It does not cover installation and
operational related problems such as over-firing, use of corrosive driftwood,
downdrafts or spillage caused by environmental conditions, nearby trees,
buildings, hilltops, mountains, inadequate flueing or ventilation, excessive
offsets, negative air pressures caused by mechanical systems such as furnaces,
fans, clothes dryers, etc.
At no time will Regency Fireplace Products be liable for any consequential
damages which exceed the purchase price of the unit. Regency Fireplace
Products has no obligation to enhance or modify any unit once manufactured.
ie. as products evolve, field modifications or upgrades will not be performed.
Regency Fireplace Products will not be liable for travel costs for service
work.
Installation and environmental problems are not the responsibility of the
manufacturer and therefore are not covered under the terms of this warranty
policy.
Any unit which shows signs of neglect or misuse is not covered under the terms
of this warranty policy.
The warranty will not extend to any part which has been tampered with or
altered in any way, or in our judgment has been subject to misuse.
Freight damage to stoves and replacement parts is not covered by warranty and
is subject to a claim against the freight carrier by the dealer.
Regency Fireplace Products will not be liable for acts of God, or acts of
terrorism, which cause malfunction of the appliance.
Performance problems due to operator error will not be covered by this
warranty policy.
Products made or provided by other manufacturers and used in conjunction with
the operation of this appliance without prior authorisation from Regency
Fireplace Products may nullify your warranty on this product.
Register your Regency ® warranty online www.regency-fire.com.au
http://www.regency-fire.com.au/Customer-Care/Warranty-Registration.aspx
Reasons to register your product online today!
- View and modify a list of all your registered products.
- Request automatic email notification of new product updates.
- Stay informed about the current promotions, events, and special offers on related products.
- Help assure you get the most out of your warranty.
- Eliminate confusion and frustration if warranty service is required in the future.
Proof of purchase required at time of warranty request.
Installer: Please complete the following information
Dealer Name & Address: __
Installer:
Phone #:
Date Installed: __
Serial No.: __
© Copyright 2013, FPI Fireplace Products International Ltd. All rights reserved.
Regency Renmark Freestanding Wood Fire