REGENCY EX110 Electric Fireplace User Guide

May 15, 2024
Regency

Onyx EX110/EX150/EX190
Electric Fireplace
REGENCY EX110 Electric Fireplace

MODELS Max. Power Consumption
EX110 120VAC (1500W)
EX150 120VAC (1500W)
EX190 120VAC (1500W)

Unit Dimensions

REGENCY EX110 Electric Fireplace - FRONT VIEW

MODEL A B C D E F G H

(inches/mm)
Onyx EX110| 45-7/16” (1154 mm)| 24-3/4″ (628 mm)| 44″ (1118 mm)| 17-7/16″ (443 mm)| 43-5/16″ (1100 mm)| 16-3/4″ (425 mm)| 4-3/8″ (111 mm)| 17-3/8″ (442 mm)
Onyx EX150| 61-3/16″ (1554 mm)| 24-3/4″ (628 mm)| 59-3/4″ (1518 mm)| 17-7/16″ (443 mm)| 59-1/16″ (1500 mm)| 16-3/4″ (425 mm)| 4-3/8″ (111 mm)| 17-3/8″ (442 mm)
Onyx EX190| 78-15/16″ (2005 mm)| 24-3/4″ (628 mm)| 77-1/2″ (1968 mm)| 17-7/16″ (443 mm)| 76-3/4″ (1950 mm)| 16-3/4″ (425 mm)| 4-3/8″ (111 mm)| 17-3/8″ (442 mm)
MODEL| I| J| K| L| M| N| O| P
(inches/mm)
Onyx EX110| 2-5/8″ (66-1/2 mm)| 17-1/2″ (445 mm)| 33-15/16″ (862 mm)| 11-13/16″ (300 mm)| 13-1/4″ (336 mm)| 7/8″ (22 mm)| 1/2″ (12 mm)| 8-1/2″ (216 mm)
Onyx EX150| 2-5/8″ (66-1/2 mm)| 17-1/2″ (445 mm)| 50-9/16″ (1284 mm)| 11-13/16″ (300 mm)| 13-1/4″ (336 mm)| 7/8″ (22 mm)| 1/2″ (12 mm)| 8-1/2″ (216 mm)
Onyx EX190| 2-5/8″ (66-1/2 mm)| 17-1/2″ (445 mm)| 69-7/16″ (1764 mm)| 11-13/16″ (300 mm)| 13-1/4″ (336 mm)| 7/8″ (22 mm)| 1/2″ (12 mm)| 8-1/2″ (216 mm)

Framing Installation (Single Sided)

NOTE : Framing may be constructed of combustible material (i.e. 2 x 4/2 x 6) and does not require steel studs.

NOTE : The appliance must be installed on a flat, solid, continuous surface (e.g. wood, metal, concrete).which must be the full width and depth of appliance.
This may be the floor, or raised up on a platform to enhance its visual impact.
Note : Measurement (B) does not include height of platform base if raised off the ground.
Example 1/2″(13 mm) thick platform base = 25-3/4″ (654mm) framing height.

ONYX A B C
EX110 44-13/16″
(1138 mm) 25-1/4″
(641 mm) 12-7/16″

(316 mm)
EX150| 60-9/16″
(1538 mm)| 25-1/4″
(641 mm)| 12-7/16″
(316 mm)
EX190| 78-1/4″
(1988 mm)| 25-1/4″
(641 mm)| 12-7/16″
(316 mm)

Framing

COMPLETING THE INSTALLATION (SINGLE SIDED)

The appliance is designed to be used with 1/2 in. (13 mm) wall sheathing materials such as drywall, plywood, wood composites, or noncombustible materials with the supplied decorative trim.
Thicker materials may also be used.
Thicker finishing materials would need to go around the perimeter of the decorative finishing trim. Ensure there is a minimum of 1/16″ (3 mm) gap around the perimeter of the decorative trim to ensure safe removal to clean glass or for servicing appliance.
See technical specifications in this manual for overall sizes of decorative trim.
Facing and/or finishing materials must never overhang into the glass opening.
Facing materials may be combustible or non-combustible. To cover cut/ exposed edges of the combustible facing material or any other finishing materials being used we suggest using J Style Trim or Metal Corner Bead purchased at your local hardware store.
Do not penetrate any screws into the body face.

REGENCY EX110 Electric Fireplace - fig1

PAINTING
If desired finishing includes a painted wall, 100% acrylic latex, oil-based, or standard acrylic paints may be used. Follow paint manufacturer’s instructions for paint and primer application.

TWO SIDED VIEW INSTALLATION (LEFT/RIGHT SIDED)
Note : If glass is going to be on other side, simply reverse framing methods. Framing shown with small glass on left hand side.

REGENCY EX110 Electric Fireplace - INSTALLATION NOTE : The appliance must be installed on a flat, solid, continuous surface (e.g. wood, metal, concrete) which must be the full width and depth of appliance.
This may be the floor, or raised up on a platform to enhance its visual impact.
Note : Measurement (B) does not include height of platform base if raised off the ground.
Example 1/2″(13 mm) thick platform base = 25-3/4″ (654 mm) framing height.

ONYX A B C
EX110 44-7/16” (1128 mm) 25-1/4” (641 mm) 12-7/16″ (316 mm)
--- --- --- ---
EX150 60-3/16” (1528 mm) 25-1/4” (641 mm) 12-7/16″ (316 mm)
EX190 77-7/8” (1978 mm) 25-1/4” (641 mm) 12-7/16″ (316 mm)

COMPLETING THE INSTALLATION
TWO SIDED VIEW INSTALLATION (LEFT/RIGHT CORNER)
The appliance is designed to be used with 1/2 in. (13 mm) wall sheathing materials such as drywall, plywood, wood composites, or non-combustible materials.
Thicker materials may also be used.
Note: The decorative finishing trim is not used when installed as as a two sided view and will need to be recycled.
Facing and/or finishing materials must never overhang into the glass opening.
Facing materials may be combustible or non-combustible.
To cover cut/ exposed edges of the combustible facing material or any other finishing materials being used we suggest using J Style Trim or Metal Corner Bead purchased at your local hardware store.
Do not penetrate any screws into the body face.

REGENCY EX110 Electric Fireplace - Framing

PAINTING
If desired finishing includes a painted wall, 100% acrylic latex, oilbased, or standard acrylic paints may be used.
Follow paint manufacturer’s instructions for paint and primer application.

THREE SIDED VIEW INSTALLATION

REGENCY EX110 Electric Fireplace - THREE SIDED VIEW
INSTALLATION

NOTE: The appliance must be installed on a flat, solid, continuous surface (e.g. wood, metal, concrete).which must be the full width and depth of appliance. This may be the floor, or raised up on a platform to enhance its visual impact.
Note: Measurement (B) does not include height of platform base if raised off the ground. Example 1/2″(13 mm) thick platform base = 25 3/4″ (654 mm) framing height.

ONYX A B C
EX110 44-1/2″ (1130 mm) 25-1/4″ (641 mm)
EX150 60-1/4″ (1530 mm) 25-1/4″ (641 mm)
EX190 77-15/16″ (1980 mm) 25-1/4″ (641 mm)

COMPLETING THE INSTALLATION THREE SIDED VIEW INSTALLATION

The appliance is designed to be used with 1/2 in. (13 mm) wall sheathing materials such as drywall, plywood, wood composites, or non-combustible materials. Thicker materials may also be used.
Note: The decorative finishing trim is not used when installed as as a three sided view and will need to be recycled.
Facing and/or finishing materials must never overhang into the glass opening.
Facing materials may be combustible or non-combustible.
To cover cut/ exposed edges of the combustible facing material or any other finishing materials being used we suggest using J Style Trim or Metal Corner Bead purchased at your local hardware store.
Do not penetrate any screws into the body face.

REGENCY EX110 Electric Fireplace - THREE SIDED VIEW

PAINTING
If desired finishing includes a painted wall, 100% acrylic latex, oil based, or standard acrylic paints may be used.
Follow paint manufacturer’s instructions for paint and primer application.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Regency User Manuals

Related Manuals