BLAUPUNKT KPT-R1 Wireless Remote Keypad with Proximity Tags Instruction Manual

June 6, 2024
Blaupunkt

BLAUPUNKT KPT-R1 Wireless Remote Keypad with Proximity Tags

Wireless Remote Keypad with Proximity Tags (KPT-R1)

Parts Description

  1. Active LED (Blue/Orange)

  2.  Status LED (Blue/Red)

  3.  Fault LED (Orange)

  4.  Away Arm Key

  5.  Home Arm Switch

  6.  Status Key

  7.  Disarm Key

  8. Panic Alarm
    Press both 1 and 3 keys to trigger a Panic alarm

  9.  Fire Alarm
    Press both 4 and 6 keys to trigger the Fire alarm

  10.  Emergency Alarm
    Press both 7 and 9 keys to trigger an Emergency alarm

  11.  Battery Insulator

  12.  Mounting Knockouts

  13.  Tamper Switch
    The Tamper switch protects the PIR from unauthorized cover opening.

  14.  RFID TAG

Package Content

  • 1 x Remote Keypad
  • 2 x wall plugs and screws
  • 2 x RFID Tags
  • 1 x 3V lithium batteries (pre-installed)
  • NOTE: This device works with a genuine Rolling Code encryption. Please only use it with a control panel with Rolling Code, otherwise won’t be possible to pair the device.

Learning

For learning the Remote Keypad

  1.  Put the Control Panel into learning mode.
  2.  Press both # and * keys to transmit learn code
  3.  Refer to Control Manual to complete the learning process.

Installation

The Remote Keypad has 2 knockouts on the back where plastic is thinner for wall mounting.

  1.  Use the two knockouts on the back to mark the position on the wall at chest height. Open the back cover.
  2.  Drill holes into the wall using the knockouts as a template.
  3.  Fix the keypad base onto the wall with the screw and plugs provided.
  4.  Replace the keypad cover onto the base.

Operation

Standby Mode
The Remote Keypad features a power-saving feature. When no key is pressed for 5 seconds, the Remote Keypad will turn off automatically to conserve power. When any key is pressed, the Remote Keypad will wake up and turn on the Active LED to indicate it is now under normal operation.
Keypad Settings
The Remote Keypad features a Test (programming) mode for you to customize its setting. Before you start using the Remote Keypad, you should first finish configuration setting.
The Remote Keypad also features a Keypad PIN code which is used to access the Test mode, To enter Test Mode, Enter “0000”(Default Keypad PIN code) + “*” key, the Active Orange LED will light up. Under Test Mode, the following functions include

Key Function
“*” + “1” Tag Management
“*” + “7” Transmit learn code (same as pressing both # and * keys under

normal mode)
” + “2”| Enable dual key Panic Alarm function
” + “3”| Enable dual key Fire Alarm function
” + “4”| Enable dual key Medical Alarm function
” + “5”| Disable all dual key functions
“*” + “6”| Change Keypad PIN Code:

1. Enter old code + “Status” Key

2. Enter new 4-digit code + “#” key

“*” + “8” Enable Arming without Use PIN code function
“*” + “9” Enable Arm with User PIN code function (Default)
“*” + “0” Enable Arming with KP PIN code function
“Disarm” twice To leave Test Mode

RFID TAG Management
The Keypad can function with the RFID tags included in the package. By assigning a User PIN Code to a Tag, you can use the Tag to Arm/Home/Disarm the Control Panel with a simple swipe.
Up to 6 tags can be stored in the Keypad and assigned to User PIN Codes for panel control
Add New Tag

  1.  Enter Keypad Test Mode.
  2.  Enter “*”+“1” for Tag Management. Red Status LED will light up.
  3.  Enter a 4-digit “Control Panel User PIN Code” + “#” key.
    Status RED LED flashes| Success
    ---|---
    Status Blue LED flashes with 4 beeps| Error: Wrong PIN Code length
    Status Red LED flashes with 4 beep| Error: Keypad already stored 6 Tags
  4.  Put the TAG close to the Keypad when Status Red LED is flashing.
    Status RED LED On with 2 beeps| Success
    ---|---
    Status Red LED On with 1 bee| Same PIN Code already assigned to this Tag
    Status Red LED On with 4 beeps| Error: Tag already assigned to ano- ther User PIN Code
  5. After finishing adding new Tag, press the “Disarm” key to exit Tag Management

Remove Existing Tag

  1.  Enter Keypad Test Mode.
  2.  Enter “*”+“1” for Tag Management. Red Status LED will light up.
  3.  Enter the User PIN Code of the Tag you want to remove, then press the Status key.
  4.  The Keypad will emit a long beep, the Tag info is removed.

Arm/Home/Disarm

If Remote Keypad is set to “Arm with Use PIN code” (“*” + “9” under Test Mode)

Away Arm| 1. Enter a Control Panel User PIN Code + “Arm” Key.

2. Press “Arm” Key + put Tag on Keypad.

---|---
Home Arm| 1. Enter a Control Panel User PIN Code + “Home” Key.

2. Press “Home” Key + put Tag on Keypad.

Disarm| 1. Enter a Control Panel User PIN Code + “Disarm” Key.

2. Press “Disarm” Key + put Tag on Keypad.

If Remote Keypad is set to “Arm without Use PIN code” (“*” + “8” under Test Mode)

Away Arm Press “Arm” Key
Home Arm Press “Home” Key
Disarm Enter a Control Panel User PIN Code

+ “Disarm” Key

If Remote Keypad is set to “Arm with Keypad PIN code” (“*” + “0” under Test Mode)

Away Arm Enter Keypad PIN Code + “Arm” Key
Home Arm Enter Keypad PIN Code + “Home” Key
Disarm Enter Keypad PIN Code + “Disarm” Key

Checking Control Panel Status

Press the Status key to inquire about Control Panel status, the Status LED will light up according to Control Panel mode.

Red LED On Away Arm mode
Red LED Flash Home Arm mode
Blue LED on Disarm mode

Dual Key Alarm Function

The dual Key Alarm function will activate the alarm when both keys are pressed at the same time. To use the functions, please enable them under Test Mode. (Default are disabled)

“1” + “3” Panic Alarm
“4” + “6” Fire Alarm
“7” + “9” Emergency Alarm

LEDs Active LED

The Active LED light-up whenever any key is pressed.

Off Keypad in Standby Mode
Blue LED On Keypad in Normal Operation
Blue LED Flash Keypad in Normal Operation and under Low Battery
Orange LED On Keypad in Test Mode
Orange LED Flash Keypad in Test Mode and under Low Battery

Status LED
The Status LED light up during operation or when the “Status” key is pressed to inquire Control Panel status

Red LED On Away Arm mode
Red LED Flash Home Arm mode
Blue LED On Disarm mode
Blue LED Flash No reply from Control Panel Incorrect PIN code

Request for Home arm when under Away arm mode

Request for Force Arm

Fault LED
The Fault LED light-up whenever faults are detected in the alarm system.

Orange LED On Alarm in memory
Orange LED Off Fault exists in system

Battery

The Remote Keypad uses one 3V lithium battery as its power source. It also features low battery detection function to notify the Control Panel when battery voltage is low.
When the Remote Keypad is on low battery, follow the procedure below to change the batteries.

  1.  Open the back cover
  2.  Remove the old batteries
  3.  Press any key several times to fully discharge.
  4.  Insert the new batteries observing correct polarity.
  5.  Replace the back cover.

Factory Reset

If you forget your Keypad PIN code or the Remote Keypad has any problem, you can reset the Remote Keypad to factory default.

  1.  Open the back cover and remove the battery
  2.  Press and hold the “3” key and insert the battery
  3.  The Remote Keypad will sound 3 short beeps
  4.  Release “3” key, the reset process is now complete

Specification Environmental Condition
10°C to 40°C, relative humidity 85% non-condensing. Radio 868 MHz

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Blaupunkt User Manuals

Related Manuals