Product Summary:
TGT70 series thermostats are luxurious programmable thermostats with large screen displays. It is applied to temperature control of the industrial, commercial, and domestic room, and start of control heating appliance, especially used in the floor-heating systems.
Technical Parameter:
Power Supply | 200 ~ 240V 50 ~60Hz |
---|---|
Current Load | ≤3A(water heating) |
≤16A(electric heating)
Power Consumption| <0.3W
External Material| PC+ABS (flame retardant)
Sensing Element| NTC
Set Temp. Range| 5-99℃ (factory setting 5-35℃)
Floor Set Temp. Range| 5-99℃
Accuracy| ±1℃
Dimension| 86x86x13.3mm
Ambient Temp.| 0-45℃,5-95%RH(Non-condensing)
Storage Temp.| -5~55℃
Timing Error| <1%
Main Functions and Characteristics
- Modern design is similar to a cell phone.
- Large screen display and touch button.
- Power-off memory function.
- Real-time data save function.
- 5+2 or 6+1or 7days six periods program schedule.
- Selectable 80mmx80mm European hidden box.
- Precise comfort control keeps temperature within1°C of the level you set.
User Interface Explanation
V. Model Definition
WP: For Water Heating System, 3A
EP: For Electric Floor Heating System, 16A
For example TGT70-EP TGT70-WP
VI. Model Spec
Model| Current Loading| External Sensor| Week Programmable| Child Lock| Drop
up
---|---|---|---|---|---
TGT70-EP| 16A| ✓| ✓| ✓| Optional
1-GT70-WP| 3A| ✓| ✓| ✓| Optional
Operation Instruction
-
Setting Power on/off
Press to turn on/off the power. -
Setting Temperature
Press. -to set the temperature. -
Setting the Clock
Press to set the minute, hour, and week.
Press, for adjusting. -
Setting the Manual Mode. Manual mode means non-programmable mode.
Press then ‘ will display in the screen, it is in manual mode.
Press. to set the temperature.
Press to set the minute, hour, and week. -
Setting the Child Lock Long press to enter into child lock mode, 8 will display. Long press again, the child lock will be disappeared.
-
Setting the Programmable Mode.
Press and hold ( into programmable mode. LOOP and 12345 will display.
Press. v” to select the control way: 5+2 or 6+1 or 7 days programmable. 12345 display in the position of the week means 5+2; 123456 display in the position of the week means 6+1; 1234567 display in the position of the week means 7 days programmable.
Press to select the periods. Press to changes the temperature;
Press to do time adjustment. Pressao7fto change the time;
Press again to select the weekend’s temp.
If you want to make temporary adjustments in any period,
press to then . will flash. When finish the setting, all will confirm te Windom automatically. sO settingstoactiva
Press to switch operation between manual mode and programmable mode.
Period | Period Icon | Defaulted Time | Defaulted Temp. |
---|
Week
| 1|
| 6:00| 20℃
2| | 8:00| 15℃
3| | 11:30| 15℃
4| | 12:30| 15℃
5| | 17:30| 22℃
6| | 22:00| 15℃
Weekend
| 1|
| 8:00| 22℃
2|
| 23:00| 15℃
Remark:
- The defaulted temperature of period3 and period4 is the same as period2. Please change it according to the request.
- When the set temperature is 00, this period is powered off.
- How to check floor temp?
During power-on, press and hold then press the button of power to check floor temp.. OUT TEMP will display. Press again to display room temp.
Advanced Setting
In the state of power-off, long press and hold then press into advanced setting mode. Then press to set relative item.
Display Code Function | Setting And Options | Factory Default |
---|---|---|
SEN | Sensor mode | 0:Internal sensor 1:Floor sensor |
2:Both internal sensor and floor sensor | 0 | |
LIV | Set temp. the range for the floor sensor | 5-99°C |
DIF | Precision | |
floor temp. | 1-9°C | |
2°C | 2℃ | |
SAVE | High limit temp. for internal sensor | 5-99°C |
35°C | 35℃ | |
SVL | Low limit temp for internal sensor | 5-99°C |
ADJ | Measure temp. | Check and calibrate the actual room temp. |
calibrate
FRE| Anti-frozen| 00 : Close anti-frozen 01 : Open anti-frozen| 00
PON| Power memory| 00: Power memory off
01 : Power memory on| 00
DFI| Precision for room temp.| 0.5-3°C| 1°C
FAC| Factory setting| 00: Return to factory setting
08 : Just display| 08
Remark:
Deadzone for floor temp.: i.e. the setting deadzone for floor sensor is 2, OSV
is 42℃ when actual temp. reach 44℃, the relay will stop working; when actual
temp. is back to 40℃, the relay starts working again. It works when room temp.
is lower than set temp.
Sensor error:
Please select the right sensor mode. If select a different mode or there is an
error of the sensor, Err will display on the LCD screen, the thermostat will
stop heating till the problem is solved.
Installation Instruction
This product is suitable for standard 80*80mm wall boxes and 60 mm European round box.
- Connect the line of power and valve into the terminals. Fix the wall plate into the wall box by a screwdriver.
- Connect the lines with the LCD board.
- Connect the LCD board into the wall plate.
NOTICE : The installation wire should be 1.5-2.5mm2.
X. ATT:
Thank you for buying this product!
Please read this manual for complete instructions on installing and operating
your thermostat. If you require further assistance, please feel free to
contact us.
In the box you will find:
Model | TGT70-EP | TGT70-WP |
---|---|---|
Thermostat | √ | √ |
User Manual | √ | √ |
Screws | √ | √ |
Dryer | √ | √ |
External sensor | √ |
Our Service:
We offer a warranty of 24 months from the sales day.
During the warranty, if it belongs to the quality issue, we will fix or
replace them for you by free after testing them.
If it is not a quality problem or beyond the warranty time, we will charge for
the after-sales service.