BEOK TCR7 WiFi RGB Colorful LCD Screen Smart Thermostat Instruction Manual
- June 6, 2024
- BEOK
Table of Contents
Verson:TCR71.0(04/2021)
View all BEOK thermostat manual
RGB Colorful LCD Screen Smart Thermostat
√ Scan QR code to finish network configuration swiftly, easily and
conveniently.
√ The programmable device, multiple periods allowed to set per day.
√ 2.8 inches ultra-large colorful LCD screen, delicate visual effect.
√ Work with TmallGenie, voice control available.
Parameter
Supply voltage | AC100~240V;50–60Hz |
---|---|
Power consumption | 1W Max (Wi-Fi 3W Max) |
Temp. setting range | 5~95°C |
Floor limited range | 20.90°C |
On/off deviation | 0.5~10°C, Factory setting ± 1°C |
Ambient temperature | -5,–50°C |
Protection level | |
Shell material | Anti-Flammable PC |
Product Overview
This series of thermostats has Floor Heating, Fan Coil, and Integrated version, meeting the requirements under different scenarios.
Version | System mode | Model | Application |
---|
Floor
heating| Heating| E P
Weekly programming
| Built-in & floor sensor, floor limit sensor +
WP| An NC/NO dual-output + Weekly programming
WP B| An NC/NO dual-output + Weekly programming+ Potential-free output
Fan Coil| Heating /Cooling / Ventilation| Ac2| Timer task + 2-pipe system
Ac2
485
| Timer task + 2-pipe system + 485Modbus (optional)
Ac4| Timer task + 4-pipe system + 485Modbus (optional)
Integrated| Heating / Cooling / Ventilation/Floor heating / Floor heating +
Heating| AW y| Floor heating & fan coil, weekly programming + Potential-free
output + Timer task + 485Modbus (optional) + Door card (optional)
Display Symbols
Temperature Control Mode(Floor Heating/Integrated)
Auto Mode Weekly-circled program, up to 6 heating events can be set per day.
Heating events, workdays, and temperatures can be separately customized based
on personal routines.
Manual Mode Thermostat works based on manually-set temperature, disconnecting
from auto mode.
Temporary Mode Thermostat works based on manually-set temperature temporarily
and then shifts back to auto mode till the next event.
User Operation
Power off Press “ ” shortly to turn on/off the thermostat.
Temp setting: Rotate handwheel” “to change the set temperature by 0.5°C.
System node: Press “ ” shortly to switch cooling/heating/ventilation. (Fan
Coil)
Press ” ” shortly to switch cooling/heating/ventilation/floor heating/ floor
heating + heating. (Integrated)
Enter menu: Press “ ” enter the menu interface.
Temp control mode: Press ” ” shortly to switch manual/auto mode. (Floor
heating)
Press ” ” shortly to switch manual/auto mode. (Integrated, floor heating)
Child-lock Press ” M ” + ” for 3 seconds to activate child-lock.
Auto-mode Setting
When device is off, press ” ” to enter menu page, choose “period setting” to set parameters, then press “ ” to save and exit.
Events | Time | Temperature |
---|---|---|
Default value | Modify | Default value |
Workdays | Sunrise | 0 6 |
Morning | 0 8 : | 0 0 |
Nooning | 11 : | 30 |
Afternoon | 12 : | 30 |
Evening | 17 : | 00 |
Night | 22 : | 00 |
Weekends | Sunrise | 06 : |
Night | 22 : | 00 |
Advanced Setting (Usually for Professional Technicians)
Choose “advanced setting” on the menu page and put in password 123456 to
enter the advanced setting page, set parameters then press “ ” to save and
exit.
Meaning | Rotate handwheel | Default value |
---|---|---|
Sensor Mode | Built-in Sensor |
Floor Sensor
Built-in Control&Floor Limitation
| IN
Buit4n Sensor Calibration| –5-5°C| —3°C
Buit-in Max Setting Value| 5-95°C| 50°C
Floor Max Setting Value| 10-95°C| 50°C
Limitation Value| 20-95°C| 35°C
Output Jitter Control| 0-5°C| 1*C
Anti-Freeze Protection| ON/OFF| OFF
Linkage Mode| Noninverting
Inverting Inverting Inverting and Anti-Freeze closed
| Noninverting
Linkage Time Delay| 0-5Min| 0Min
Weekday Mode| Monday to Friday/Monday to Saturday /Monday to Sunday/| 2-d a y
Boot Type| Function Off/Functon On/Function Saved| 0 F F
Temperature Unit| F/QC| QC
Child Lock Type| None
Lock All
All but power
| None
Control Mode| All/Air/Floor| Floor
Cloud Region| CN/US/EU| CN
Reset All Settings| /| /
RGB Colorful LCD Screen Smart Thermostat
Sensor failure
Please select the work mode of sensors correctly. When it shows EO/E1 error,
the thermostat will stay power-off till the error is eliminated.EO: the built-
in sensor is short-circuited or disconnected. El: floor sensor is short-
circuited or disconnected.
Timer Task Setting (Fan Coil/Integrated)
Press” “to enter the menu. Turn the knob” “, choose “Auto Mode”, and then
choose “Schedule”. Set the parameters by turning the knob, then press ” 8r to
save and exit to the home page
Mounting Steps
The thermostat adopts a pre-guide and limited snap-fit design. It is easy to
mount.
-
Release the front cover by inserting a head screwdriver into the bottom crack.
-
Insert the wires and then fix these wires with screws. The suggested wire-stripping length is 7-9mm.
-
Mount backing plate into wall-cassette, put screws, and then fix the thermostat. Make sure that the thermostat is fixed without deformation. Suggested torque is 0.2-0.4N.m (2.0-4. lkgf.cm).
-
Re-mount the front cover via a snap-fit connection.
Installation instructions
Connecting Diagram
The thermostat operates in full capacity in areas with an altitude of less
than 2500 above sea level. The power rating of external load should be less
than or equal to 80% rated power of the thermostat in areas with an altitude
of 2500m to 4200m.
Floor Heating
|
---|---
|
BEOK TCR7 WiFi Smart Thermostat Instruction Manual
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>