INSTALLATIONS

Unpack

Note 1: Subject to modification. Actual product and accessories may differ in appearance.

Find additional manuals, the datasheet, the EU Declaration of Conformity, and the latest firmware for this product at: https://tkhsecurity.com/

Installation Notices

CAUTION:
INSTALLATION SHALL BE PERFORMED BY QUALIFIED PERSONNEL ONLY. INSTALLATION SHALL BE IN ACCCORDANCE WITH LOCAL PROCEDURES. IT’S NOT RECOMMENDED TO USE WIPER WITHOU WASHER TANK. IT WILL CAUSE THE UNREPAIRABLE SCRATCH ON THE GLASS. PLEASE APPLY APPROPRIATE PROTECTION TO THE EYES WHEN INSTALL IR MODULE ON THE HOUSING.

Connectors

I/O Terminal Block Connection

I/O Description
DO2 Connect to tank water pump.
DI2 Wiper control, connects to IP camera’s DO for manually

triggering washer.

RS485+|

Serial port to control IR, wiper and washer.

RS485-
DO+| +5V VCC
DI-| GND
DO1| IR LED status, connect with camera input to control IR cut filter(default)
DI1| IR control by camera

**Connection diagram

**

RS485 Control

Configuration parameters

Protocol     Baud rate    Data bits     Parity          Stop bit

Pelco-D       2400            8                  None           1

Pelco-D command

Control                              Pelco-D Command

Wiper On                            Aux 1 On

Wiper Off                           Aux 1 Off Wiper and Washer On Aux 2 On Wiper and Washer Off   Aux 2 Off IR Led Force On                      Aux 3 On

IR Led Force Off                 Aux 3 Off

HSG04-IR Wide                  Zoom Wide

HSG04-IR Tele                    Zoom Tele

HSG04-IR Stop                    Zoom Stop

Note 2 : Once RS485 control the IR Led, the IR mode will be in RS485 control. Please switch to “Light Sensor mode” by “ FF 01 00 18 02 02 1D” Pelco-D command. The Light sensor

at lamp will control the lamp by the lighting condition.

Complete HSG04 housing with accessories

TK-HSECURITY-HSG04-All-Weather-
Outdoor-Camera-Housing-3

Optional Accessory – HSG04-IR

  1. Remove the metal cover from underneath the housing.
  2. nstall HSG04-IR module and ensure the rubber gasket is in place.TK-HSECURITY-HSG04-All-Weather-Outdoor-Camera-Housing-4
  3. Adjust the IR distance by DIP switch.

TK-HSECURITY-HSG04-All-Weather-Outdoor-Camera-
Housing-14

DIP Switch LL LH HL HH
Beam angle 10° 20° 30° 40°
Distance (meter) 140m 110m 80m 50m

Optional Accessory – HSG04-Wall Mount

  1. Fasten 2 screws to secure the intersection bracket at the bottom of housing.
  2. Install the housing by pressing the spring mortise and hook the bracket onto the groove in the spring mortise. Fasten the screws on the side.
  3. Connect the safety wire between wall mount and the housing.
  4. Fasten the wall mount to the mounting holes as indicated above.

Optional Accessory – HSG04-Pole Mount
HSG04-pole mount can be used with HSG04-wall as well as HSG04-power box. The different mounting holes are indicated below.

Optional Accessory – HSG04-Power Box
HSG04-Power box can be installed with HSG04-Wall as well as HSG04-Pole. The different mounting holes are indicated below.

Optional Accessory –
Water Tank, WP10-10m-24Vac
Install the washer nozzle with bracket to the side of the HSG04. Connect a piece of Ø8mm hose to the nozzle and use Ø8-4 hose adapter as the bridge to the hose included in WP10-10m-24Vac. Secure each connections with cable tie.