BEOK TGP51-AC Fan Coil Thermostat User Guide

June 6, 2024
BEOK

TGP51-AC Fan Coil Thermostat

thermostat coil

View all BEOK thermostat manual

I. Product Summary:

Touch screen Series thermostats are designed to control the fans and valves
in air conditioner applications via comparison of the room temperature and
setting temperature as reaching the aim of comfort and saving energy.

II. Technical Parameter

technical program

III.Main Functions and Characteristics

  1. Modern design similar as a cell phone.
  2. Large glass screen display with White/Blue backlight.
  3. 2-pipe and 4-pipe for choose.
  4. 3 Fan speed+ auto timer switch for daily or week.
  5. Timer on/off function for daily or week.
  6. Room temp calibration function.
  7. Selectable 80mmx80mm hidden box.
  8. Precise comfort control keeps temperature within1°C of the level you set.

IV. User Interface Explanation (Thermostat Port)

V. Model Definition

AC 2: Two pipe, for air conditioning
AC 4: Four pipe, for air conditioning

For example: TGP51-AC2
TGP51-AC4

VI. Model Spec

VII. Dimension

VIII. Wiring Diagram

pipe setup

IX. Thermostat Opera

  1. Setting Power on/off Press to turn on/off the power.

  2. Setting Temperature Press AV to set the temperature

  3. Setting the System Mode
    Long press @ to select 3s heating, cooling or 4 ventilation in the on state. Factory Default is ventilation.

  4. Setting the Fan Speed
    Press “f to select the fan speed.
    SG is Low speed(Factory default);
    & is Mid speed;
    & is High speed;
    © is Auto speed.
    In auto mode, the fan will run according to the comparison of room temperature and set temperature.

  5. Setting the Real Time.

Press and hold “f” for 3 sec., hh will flash in the position of hh: mm.
Press AV to adjust the current hour.
Press , mmwill flash in the position of hh: mm.
Press AV to adjust the current minute.
Press @ , 1 will flash in the position of week: 1234567.
Press A‘V to adjust the current week.

6. Setting the Time-on(Regular Boot)

Press°f* for more than 3 seconds, after setting the time, continue to press ®
until Gand “hh” twinkling. Press AY7to adjust the hours.

After the adjustment of hours, press @ until the “mm” twinkling,
pressAV7 to adjust the minutes.

After the completion of all adjustments , press “f” to confirm, then C} does not twinkle,
Regular boot setup is complete.

The operation of canceling Regular boot is the same, press @ to the state of
Regular boot, then pressing the (> is twinkling, Regular boot has been canceled.

7. Setting the Timer off

After the setting of Regular boot, press © again, until {}> and “hh” twinkling,
press AV/to adjust the hours.

After the adjustment of hours is completed, press @until the“mm’twinkling,
press A‘ to adjust the minutes.

After the completion of all adjustment, press ‘to confirm, then{} does
not twinkling, Off timer setup is completed.

The operation of canceling Off timer is the same, press @ to the state of
Off timer, then pressing °f, the {XJ> is twinkling, Off timer has been canceled.

The setting of the third period and forth period are same with the first and
second period, the icons are {X= }> (on, offinto the house, out of the house)

8. Setting the Circulation of Timer Switch

After setting the time of timer switch, continue to press the ® , there will
be “LooP”, then press AY, week display area will displays the day of
the week, or the transformation of “12345” “123456”, or “1234567”,

Ifthe screen only displays the day of the week, then the timer switch setting
is valid only for the day.(= “Execute once” in App interface)

Ifit displays “12345”, then the timer switch is valid from Monday ~ Friday,
and Saturday and Sunday will be invalid

Ifit displays “123456”, then the timer switch is valid from Monday ~Saturday,
and Sunday will be invalid.

Ifit displays “1234567″, then the timer switch is valid from Monday ~ Sunday.

9.Advanced Setting Mode

In power-off state, press “f and ® meanwhile, to enter into Advanced Setting.
Press ® to switch dIF, Sh1, S12, Sh2, S12, ADJ, FAN, FrE, LOC, ADD, FAC.
display code

Deadzone:
Eg, when room set temperature =22’C, dif=1°C, in cooling mode.
When room temp drop to 21°C, the relay stop out putting.
When temp up to 22°C, the relay start output and refrigerate(cooling) again.

XII. Installation Instruction

The products suits for standard 80*80mm wall box or 60mm Europe round

  1. Connect the line of power and valve into the terminals.
    Fix the wall plate into the wall box by a screwdrive.

  2. Connect the lines with the LCD board.

  3. Connect the LCD board into the wall plate.

XIIL. Attention

Thank you for buying this product!

Please read this manual for complete instructions on installing and
operating your thermostat. If you require further assistance, please
feel free to contact us.

In the box you will find:

Our Service:
We offer the warranty of 24 months from the sales day.

During the warranty, if it is belong to the quality issue, we will fix or replace
by free after testing

Ifitis not quality problem or beyond the warranty time, we will charge for
the after-sales service.

Warning: The symbol means the unit is being installed, it may cause electrical shock hazard during maintaining, so please make sure it is operated by the professional technical worker.

BEOK TGP51-AC Fan Coil Thermostat User Guide