BOT series boiler thermostats are with LCD digital display big screen, and it is developed according to market’s requirements. Thermostats can be installed on the wall, or directly put on the table. This series thermostats are easy to operate, and with complete functions. It can be used to control boilers, motorized ball valves, motorized valves, electric valves, solenoid valves, etc.

Technical Parameter

Working Voltage USB type C (SV)
Current Load 3A
Temperature Control Accuracy ±1°C
Setting Temperature Range 5-60°C
Limiting Temperature Range 5-99°C
Consumption <0.3W
Temperature Sensor NTC

Main Button Instruction

  • : ON/OFF Switch;
  • :Mode Button. Switch between Manual Mode , Auto Period Control Mode, Temporary Manual Mode. Long press to enter period setting.
  • :Time Set. Hour, minute and week setting;
  • :Up Button. To increase temperature. When press it with and it can set programmable function;
  • ;Down Button. To reduce temperature. When press it with and it can set programmable function;
  • : Key Lock. Long press 5 seconds to lock or unlock;

User Interface Explanation

User Interface Explanation

Symbols

Function button

Model Spec

Model Wireless Function Terminal Receiver Wi-Fi Function
BOT-W306
BOT-X306 / /
BOT306RF-WIFI / / /

Operation Instruction

Time Setting

Press , the time area will display Minute, Hour and Week, then press or to modify time.

Programmable Period Temperature Setting

Temperature Setting

First step , long press , screen display LooP (Cycling Control), screen displays 12345 (From Monday to Friday); Press one time, it displays 123456(From Monday to Saturday); Press two times, it displays 1234567(From Monday to Sunday);

Second step , time and temperature setting in every period. When screen display 12345 or 123456 or 1234567, press to enter temperature setting. Press to enter time setting. To modify and save through or .

Att: When auto-control ,if user needs to reset the temperature, it can be changed to temporary manual control. Temporary manual control means when thermostat is in auto-control mode(program mode), user press  or to modify temperature setting, thermostat now is in temporary manual control state. When next periods comes, thermostat will automatically return to acquiescent period program control mode.

Programmable Period Time Setting

First press , then press to change to time options, user can modify time in the period.

Default Program Data

Default Program Data

Att

  1. The default temperature values of 3 and 4 period in workday is same with 2 period. If user need, please change this default temperature.
  2. Setting temperature is 00, it means this period is power off.

Advanced Setting

Advanced Setting

In the state of power-off, long press and hold then press into advanced setting mode. Then press to set relative item.

Display Code| Function| Setting And Options| Factory Default
---|---|---|---
dIF| Limit temp. return difference| 0.5-4.5℃| 2℃
SVH| Set temp. upper Limit| 5-99℃| 35℃
SVL| Set temp. low limit| 5-99℃| 5℃
AdJ| Measure temp.| -5-5℃(0.5℃accuracy correction)| 0.0℃

FrE

| Anti-frozen| 00:Close   anti-frozen

01:Open   anti-frozen

| 00
LOC| Button lock function| 00: Unlock

01: except power switch, all buttons are locked

02: All buttons are locked

|

00

SNP| Set Sequence Number| 00:Close this function 01:Open this function| 0
FAC| Factory setting| 08:Just display

00:Return to factory setting

|

08

Wiring Diagram

Wiring Diagram
Wiring Diagram

The button inside receiver is Reset button. When status indicator light stay on or not on, user can press reset button to resume normal work.

Att

Installation wires should be changed to be 1.5-2.5mm² hard line. Please rightly connect the wires strictly according to the connect diagram. Don’t make water, mud and other debris into the thermostat, otherwise it will damage the thermostat.

WIFI Configure

Install APP on phone

For iOS system: Login in App Store, search “ Beok RF Boiler”, you can download it on your iphone.

For Android System: Login in Google Play, search “Beok RF Boiler ”, you can download it on your phone.

Connection Thermostat with Phone

Thermostat Setting

Thermostat Setting

  1. Download and Install APP on phone.
  2. Press thermostat button for 10 seconds when thermostat is in turn-off state, then WIFI signal will appear and quickly twinkle.
  3. Enter your wifi name and password, then start connection configure.
    Connection Thermostat with Phone
    Connection Thermostat with Phone

APP Interface on the Phone

APP Interface on the Phone

Thermostat Setting through Phone Operation

  1. Clock : You can press Time Matching switch to match your phone clock with thermostat clock.
  2. Children lock (screen locking ) : Press to lock the thermostat.
  3. Anti-Freezing : Press thermostat will show on the screen , it means Anti-freezing function open.
  4. Temperature setting : You can drag the pointer on Temperature Setting Dial to set temperature. Or press and to set temperature step. directly
  5. Period setting : Long press Period Display , then you will go into the Period Setting mode
  6. Advanced Setting: Long Press Senior , you will go into Advanced setting mode:
  7. Switch of Manual mode and Auto mode: Press to switch manual mode or Auto mode.
  8. Power off : Press to turn on or off thermostat.

Installation Instruction

Insert the equipped USB (Type-C) connector into the charger.

Set Sequence Number

  1. Every thermostat has a matched receiver, and thermostat and receiver have a same group of sequence number. If user mix during installation, sequence number can be set through the following method.(Sequence number is unique)

  2. In Advance Setting, SNP need to be set 01. Then to set SN through the following four steps.
    Set Sequence Number

The first step, press button under power off state, then press button, then press button to enter parameter setting;

Set Sequence Number

The second step, after appearing SN1, press or to modify the number;

Set Sequence Number

The third step, every time pressing once , it will appear SN2, SN3, SN4, SN5 and SN6 in order. Refer to second step, press or to modify.

Set Sequence Number

The forth step, after SN is finished setting, if CHK Code is the same with bar code, it is correct. If not consistent, it is not correct. Please input again. 3.VAC: Control valves1-8 place numbers. The default value is 01. (This setting is only useful when thermostat is applied to control Wireless Main-Control Centralized Controller. If thermostat is used to control boiler, this setting must be 01.)

ATT

Thank you for buying this product!
Please read this manual for complete instructions on installing and operating your thermostat. If you require further assistance, please feel free to contact us.

In the box you will find:

Model BOT-W306 BOT-X306 BOT306RF-WIFI
Thermostat
User Manual
Screws
Receiver
USB Cable
Support Bracket

Our Service:

We offer the warranty of 24 months from the sales day.
During the warranty, if it is belong to the quality issue, we will fix or replace them for you by free after test them. If it is not quality problem or beyond the warranty time, we will charge for the after-sales service.

Warning:

The symbol means the unit is being installed, it may cause electrical shock hazard during maintaining, so please make sure it is operated by the professional technical worker.

Beok BOT306RF-WIFI BOILER THERMOSTAT User Guide

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals