BEOK BOT306RF-WiFi Boiler Thermostat User Guide
- June 6, 2024
- BEOK
Table of Contents
BEOK BOT306RF-WiFi Boiler Thermostat User Guide
View all BEOK thermostat manual
Product Summary
BOT series boiler thermostats are with LCD digital display big screen, and it is developed according to market’s requirements. Thermostats can be installed on the wall, or directly put on the table. This series thermostats are easy to operate, and with complete functions. It can be used to control boilers, motorized ball valves, motorized valves, electric valves, solenoid valves, etc.
Technical Parameter
Working Voltage | USB type C (SV) |
---|---|
Current Load | 3A |
Temperature Control Accuracy | ±1°C |
Setting Temperature Range | 5-60°C |
Limiting Temperature Range | 5-99°C |
Consumption | <0.3W |
Temperature Sensor | NTC |
Main Button Instruction
- : ON/OFF Switch;
- :Mode Button. Switch between Manual Mode , Auto Period Control Mode, Temporary Manual Mode. Long press to enter period setting.
- :Time Set. Hour, minute and week setting;
- :Up Button. To increase temperature. When press it with and it can set programmable function;
- ;Down Button. To reduce temperature. When press it with and it can set programmable function;
- : Key Lock. Long press 5 seconds to lock or unlock;
User Interface Explanation
Model Spec
Model | Wireless Function | Terminal Receiver | Wi-Fi Function |
---|---|---|---|
BOT-W306 | |||
BOT-X306 | / | / | |
BOT306RF-WIFI | / | / | / |
Operation Instruction
Time Setting
Press , the time area will display Minute, Hour and Week, then press or to modify time.
Programmable Period Temperature Setting
First step , long press , screen display LooP (Cycling Control), screen displays 12345 (From Monday to Friday); Press one time, it displays 123456(From Monday to Saturday); Press two times, it displays 1234567(From Monday to Sunday);
Second step , time and temperature setting in every period. When screen display 12345 or 123456 or 1234567, press to enter temperature setting. Press to enter time setting. To modify and save through or .
Att: When auto-control ,if user needs to reset the temperature, it can be changed to temporary manual control. Temporary manual control means when thermostat is in auto-control mode(program mode), user press or to modify temperature setting, thermostat now is in temporary manual control state. When next periods comes, thermostat will automatically return to acquiescent period program control mode.
Programmable Period Time Setting
First press , then press to change to time options, user can modify time in the period.
Default Program Data
Att
- The default temperature values of 3 and 4 period in workday is same with 2 period. If user need, please change this default temperature.
- Setting temperature is 00, it means this period is power off.
Advanced Setting
In the state of power-off, long press and hold then press into advanced setting mode. Then press to set relative item.
Display Code| Function| Setting And Options| Factory
Default
---|---|---|---
dIF| Limit temp. return difference| 0.5-4.5℃| 2℃
SVH| Set temp. upper Limit| 5-99℃| 35℃
SVL| Set temp. low limit| 5-99℃| 5℃
AdJ| Measure temp.| -5-5℃(0.5℃accuracy correction)| 0.0℃
FrE
| Anti-frozen| 00:Close anti-frozen
01:Open anti-frozen
| 00
LOC| Button lock function| 00: Unlock
01: except power switch, all buttons are locked
02: All buttons are locked
|
00
SNP| Set Sequence Number| 00:Close this function 01:Open this function| 0
FAC| Factory setting| 08:Just display
00:Return to factory setting
|
08
Wiring Diagram
The button inside receiver is Reset button. When status indicator light stay on or not on, user can press reset button to resume normal work.
Att
Installation wires should be changed to be 1.5-2.5mm² hard line. Please rightly connect the wires strictly according to the connect diagram. Don’t make water, mud and other debris into the thermostat, otherwise it will damage the thermostat.
WIFI Configure
Install APP on phone
For iOS system: Login in App Store, search “ Beok RF Boiler”, you can download it on your iphone.
For Android System: Login in Google Play, search “Beok RF Boiler ”, you can download it on your phone.
Connection Thermostat with Phone
Thermostat Setting
- Download and Install APP on phone.
- Press thermostat button for 10 seconds when thermostat is in turn-off state, then WIFI signal will appear and quickly twinkle.
- Enter your wifi name and password, then start connection configure.
APP Interface on the Phone
Thermostat Setting through Phone Operation
- Clock : You can press Time Matching switch to match your phone clock with thermostat clock.
- Children lock (screen locking ) : Press to lock the thermostat.
- Anti-Freezing : Press thermostat will show on the screen , it means Anti-freezing function open.
- Temperature setting : You can drag the pointer on Temperature Setting Dial to set temperature. Or press and to set temperature step. directly
- Period setting : Long press Period Display , then you will go into the Period Setting mode
- Advanced Setting: Long Press Senior , you will go into Advanced setting mode:
- Switch of Manual mode and Auto mode: Press to switch manual mode or Auto mode.
- Power off : Press to turn on or off thermostat.
Installation Instruction
Insert the equipped USB (Type-C) connector into the charger.
Set Sequence Number
-
Every thermostat has a matched receiver, and thermostat and receiver have a same group of sequence number. If user mix during installation, sequence number can be set through the following method.(Sequence number is unique)
-
In Advance Setting, SNP need to be set 01. Then to set SN through the following four steps.
The first step, press button under power off state, then press button, then press button to enter parameter setting;
The second step, after appearing SN1, press or to modify the number;
The third step, every time pressing once , it will appear SN2, SN3, SN4, SN5 and SN6 in order. Refer to second step, press or to modify.
The forth step, after SN is finished setting, if CHK Code is the same with bar code, it is correct. If not consistent, it is not correct. Please input again. 3.VAC: Control valves1-8 place numbers. The default value is 01. (This setting is only useful when thermostat is applied to control Wireless Main-Control Centralized Controller. If thermostat is used to control boiler, this setting must be 01.)
ATT
Thank you for buying this product!
Please read this manual for complete instructions on installing and operating
your thermostat. If you require further assistance, please feel free to
contact us.
In the box you will find:
Model | BOT-W306 | BOT-X306 | BOT306RF-WIFI |
---|---|---|---|
Thermostat | √ | √ | √ |
User Manual | √ | √ | √ |
Screws | √ | √ | √ |
Receiver | √ | √ | |
USB Cable | √ | ||
Support Bracket | √ |
Our Service:
We offer the warranty of 24 months from the sales day.
During the warranty, if it is belong to the quality issue, we will fix or
replace them for you by free after test them. If it is not quality problem or
beyond the warranty time, we will charge for the after-sales service.
Warning:
The symbol means the unit is being installed, it may cause electrical shock hazard during maintaining, so please make sure it is operated by the professional technical worker.
Beok BOT306RF-WIFI BOILER THERMOSTAT User Guide
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>