BEOK TR9B Ultra-Large Colorful Screen Capacitive Touch LCD Smart Thermostat Instruction Manual
- June 6, 2024
- BEOK
Table of Contents
BEOK TR9B-Ultra-Large Colorful Screen Capacitive Touch LCD Smart
Thermostat
Product Overview
This series of thermostats has Floor Heating, Fan Coil, and Integrated version, meeting the requirements under different scenarios.
Version | System mode | Model | Application |
---|
Floor heating
|
Heating
| EP| Built-in & floor sensor, floor limit sensor + Weekly programming
WP| A NC/NO dual-output + Weekly programming
WPB| A NC/NO dual-output + Weekly programming+ Potential-free output
Fan Coil
| Heating /Cooling / Ventilation| AC2| Timer task + 2-pipe system
AC2-485| Timer task + 2-pipe system + 485Modbus (optional)
AC4| Timer task + 4-pipe system + 485Modbus (optional)
Integrated
| Heating / Cooling / Ventilation/Floor heating / Floor heating + Heating|
AWY
| Floor heating & fan coil, weekly programming + Potential-free output + Timer task + 485Modbus (optional) + Door card (optional)
Display Symbols
Temperature Control Mode(Floor Heating/Integrated)
Auto Mode
In the weekly-circled program, up to 6 heating events can be set per day.
Heating events, workdays, and temperature can be separately customized based
on personal routines.
Manual Mode
The thermostat works based on manually-set temperature, disconnecting from
auto mode.
Temporary Mode
The thermostat works based on manually-set temperature temporarily and then
shifts back to auto mode till the next event.
- Customized exclusive temperature plan – up to 6 events allowed to set per day
- Sail-shape curved design – fashion, elegant and enduring
- UItra-large screen -better user interaction experience
- 485 Modbus and room card linkage – customized equipment (optional)
Parameter:
- Supply voltage: AC100-240V;50-60Hz
- Power consumption: 1W Max (Wi-Fi 3W Max)
- Temp. setting range: S-95’C (41-99’F)
- Floor limited range: 20-so·c csa-ss·F)
- Temp. Dif. 0.5-1D’C (1-10″F) , Factory setting ±1″C
- Ambient temperature: ~-so·c (23-122’F)
- Protection level: IP20
- Shell material: Anti-Flammable PC
User Operation
-
Power on/off:
Press “ shortly to turn on/off the thermostat. -
Auto-mode:
Press for 3 seconds to edit auto-mode settings. (Floor Heating/Integrated) -
Timer task:
Press for 3 seconds to edit the timer task. (Fan Coil/Integrated) -
Time setting:
Press for 3 seconds to set time. (Floor Heating)
Press twice for 3 seconds to set time. (Automatic time synch for Wi-Fi version) -
Temp setting:
Press or “ shortly to change setting temperature by 0.5°C. -
Child-lock:
Press ” + for 3 seconds to activate child-lock. -
System mode:
Press M shortly to switch cooling/heating/ventilation. (Fan Coil)
Press “M ” shortly to switch cooling/heating/ventilation/floor heating/floor heating + heating. (Integrated) -
Temp control mode: Press “M ” shortly to switch manual/auto mode. (Floor heating)
Press shortly to switch manual/auto mode. (Integrated, floor heating -
Fan speed setting: Press “ ” shortly to adjust fan speed.(Fan Cail/Integrated)
-
ECO mode: Press ”shortly to set to ECO mode 18°C(64°F). (Floor heating)
-
Advanced Setting (Usually for Professional Technicians)
Under power-off, press “ ” for 3 seconds to enter advanced setting mode, then re-press
“ M” to switch to next mode. Press “ ” to save and exit advanced setting mode.
Code
|
Meaning
|
“ ”or“ ”
| Default Value| Integrated| Fan Coil| Floor
Heating
---|---|---|---|---|---|---
| AC2-485
AC4
| AC2|
00| Postal address| Adjustment range 0x00~0xFA| 00| √| √| ×|
√
01| | -9.9~9.9℃(-9~9℉)| -3℃| √| √| √| √
02| Dead zone| 0.5~10℃(1~10℉)| ±1℃| √| √| √| √
03| | 5~95℃(41~99℉)| 50℃| √| √| √| √
04| | 5~47℃(41~99℉)| 5℃| √| √| √| √
05| Frost protection| ON: frost protection on
OFF: frost protection off
| OFF| √| √| √| √
06| | ℃/℉| ℃| √| √| √| √
07
|
Sensor selection
| |
IN
|
√
|
×
|
×
|
√
08| Floor limited temp.| 20~90℃(68~99℉)| 35℃| √| ×| ×| √
09| Weekly programming setting| 12345: 5/2 week mode 123456: 6/1 week mode
1234567: 7/0 week mode| 12345| √| ×| ×| √
10
|
Status of potential
-free and main power outputs
| 00: both outputs are normally open 01: main power output is normally
closed; potential-free output is normally open
02: both outputs are normally closed 03: both outputs are normally closed;
under power-off, frost protection is off either
|
00
|
√
|
×
|
×
|
√
11| Delay time of outputs| 0~5min| 0| √| ×| ×| √
12
|
Child-lock
| 00: Child-lock inactivate when screen off; lock all when child-lock activate
01: Child-lock activate when screen off; lock all when child-lock activate
02: Child-lock activate when screen off; lock all except Fan Speed, Up and Down when child-lock activate
03: Child-lock activate when screen off; lock all except Power on/off when child-lock activate
|
00
|
√
|
√
|
√
|
√
13| Power-on-reset| 00: stay power-off after Power-on-reset
01: stay power-on after Power-on-reset 02: recovery after Power-on-reset
| 02| √| √| √| √
14
|
Door card status
| 00: turn off door card function
01: set to ECO temp. after pulling door card out
02: stay power-off after pulling door
card out
|
00
|
√
|
√
|
×
|
×
15| Door card heating
ECO temp.
| 10~21℃(50-69℉)| 18℃| √| √| ×| ×
16| Door card cooling
ECO temp.
| 22~32℃(72-89℉)| 26℃| √| √| ×| ×
17| Fan coil mode setting| 00: Cooling and heating
01: Cooling only
| 00| √| √| √| ×
18| Weekly programming for Integrated| 00: turn on
01: turn off
| 01| √| ×| ×| ×
19| Reset| Press “ ”for 3 seconds to reset| /| √| √| √|
√
Auto-mode Setting (Floor Heating / Integrated)
Press “M ” for 3 seconds to edit auto-mode setting.
Timer Task Setting (Fan Coil / Integrated )
Press “ ” for 3 seconds to enter timer task setting; press “ M ” to change
settings;
Press “ ” or “ ” to adjust parameters; press “ ” to save and exit.
Dimensions (Unit: mm)
Mounting Steps
The thermostat adopts the pre-guide and limited snap-fit design. It is easy to
mount. 1)Release the front cover by inserting a head screw-driver into the
bottom crack.
Insert the wires and then fix these wires with screws. The suggested wire- stripping length is 7-9mm.
Mount backing plate into wall-cassette, put screws and then fix thermostat. Make sure that the thermostat is fixed without deformation. Suggested torque is 0.2~0.4N.m (2.0~4. 1kgf.cm).
Re-mount the front cover via snap-fit connection.\
Sensor failure
Connecting Diagram
The thermostat operates in full capacity in areas with the altitude of less
than 2500 above sea level. Power rating of external load should be less than
or equal to 80% rated power of the thermostat in areas with altitude of 2500m
to 4200m.