BEOK TGR-85 Heating Thermostat User Guide

June 6, 2024
BEOK

BEOK TGR-85 Heating Thermostat

BEOK-TGR-85-Heating-Thermostat-

THERMOSTAT USER GUIDE

THIS THERMOSTAT IS SUITABLE FOR WATER HEATING, ELECTRIC HEATING AND GAS BOILER

Product packaging

  • Thermostat host—————1 PC
  • Qualification certificate——1 PC
  • Sensing line (optional)——-1 PC
  • Manual————— 1 PC
  • Screw—————– 2 PCS

Product Model

  • WP Plumbing 3A
  • EP Electric Heating 16A
  • WPB linkage, gas boiler 3A

Welcome

Thank you for your trust and support. By adopting higher-end technology and more perfect technology, your new thermostat will provide you with the right temperature environment every day in the future, making your life more comfortable and your living environment more stylish and beautiful. For detailed instructions on the installation and use of this thermostat, please read this manual carefully. Please contact a professional to install the thermostat for you and install and use the product to the extent permitted by law

Application

Intelligent digital temperature controller is a floor heating system suitable for room temperature control and household temperature control. It controls the operating state of the floor heating equipment by comparing the ambient temperature with the set temperature, which improves comfort and achieves energy saving. This digital temperature controller adopts microcomputer control technology and is equipped with full-screen display touch buttons, which is elegant in design and easy to use. The thermostat has manual automatic, programmable and state memory functions.

User Notes

  1. Please read this manual carefully. Improper operation may damage the product or cause dangerous conditions.
  2. The installation personnel must be well-trained and experienced service technicians.
  3. After installation, please read this manual carefully and operate the product according to the instructions.
    Caution: Risk of electric shock or equipment damage.

Wiring Diagram

Note: WP for water heating; EP for electric heating; WPB for gas boiler

Installation procedure

This product is installed with a standard 86 control switch (in compliance with European regulations)

  1. Turn the fixator so that the arrow is aligned with the display screen. Remove the mounting plate
  2. Remove the mounting plate in this direction
  3. Fix the mounting plate on the cassette with a screw
  4. Insert the thermostat into the mounting plate from top to bottom and reuse ,The screwdriver will rotate the fixator 180 degrees to complete the installation.

Description of display & IconBEOK-TGR-85-Heating-
Thermostat-7

Operating Instruction

  1. 1. Power on/off: press to turn on/off the thermostat.
  2. Press the key to switch between manual and automatic modes.
  3. In the automatic mode, press or to adjust the temperature to enter the automatic temporary mode. This mode runs for only one session.
  4. Long press key and key to enter the clock setting, press key to switch Settings Item, press and keys to adjust the value of each parameter.
  5. Press and for 5 seconds to add or cancel the child lock.

Time programming instructions

Press and hold the key to enter the programming setting, short press the key to switch the option, press the key or key to adjust each option parameter, and press the key to exit and save.BEOK-TGR-85-Heating-
Thermostat-8

Advanced options

When POWER OFF, press the key and the key for 5 seconds to enter the advanced option setting. Press to enter the next option, press and to adjust, and press to exit the height Level option.

1| Temperature compensation| The default value of the calibration room temperature is -2℃. Press the up and

down keys to adjust. The adjustable range is 9.9℃ to -9.9℃.

---|---|---
2| Sensor selection| The temperature sensor is selected as IN by default. Press the up and down keys to

adjust as IN respectively, indicating that the internal.

3| Modify the temperature limit| The default temperature limit value is 35℃. Press the up and down keys to adjust

the range from 5℃ to 60℃.

4| Temperature difference

start

| The default temperature difference is set to 1 ° C. Press the up and down keys to

adjust the range to 1-10 degrees.

5| Antifreeze function| Set the default anti-freeze function to OFF, display OFF, press the up key to turn

on anti-freeze and display ON

6| Holiday option and turn off weekly programming| Set the default rest day as double OFF. Press the up and down keys to adjust it to double OFF (1-5), single OFF (1-6), no OFF (1-7) and turn off week programming (OFF).

7

| Primary and secondary reverse selection| Set the default main and auxiliary reversal to 0. Press the up and down keys to

adjust 0 to turn off the main and auxiliary reversal. 01 means auxiliary reverse, 02 means auxiliary reverse, 03 means main and auxiliary reverse, shutdown and antifreeze is not on, stop output

8| Passive linkage output delay time| Set the default passive linkage delay time to 0. Press the up and down keys to adjust the range of 0-5 minutes.
9| Set upper temperature limit| The default value of the set temperature upper limit is 60℃, and the adjustment

range is 35-95℃ by pressing the up and down keys.

10| Restore Factory Defaults| Set to restore the factory default setting to display. Press the up button to adjust the display, press the enter button to restore the factory settings.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals