Package Contents
- DIS-PWR40AC/RU power supply.
Installation
-
Always allow good ventilation clearances, 5 mm left and right, 40 mm above and 20 mm below, around the unit in use to prevent it from overheating. Also a 10-15 cm clearance must be kept when the adjacent device is a heat source.
-
The appropriate mounting orientation for the unit is vertical, the input terminals at the bottom and output on the top. Mounting orientations other than that, such as upside down, horizontal, or table-top mounting, is not allowed.
-
Use copper wire only, and recommended wires are shown as below.
AWG| 18| 16| 14
---|---|---|---
Rated Current of Equipment (Amp)| 7| 10| 15
Cross-section of Lead (mm2)| 0.8| 1.3| 2.1
Note: Current each wire carries should be de-rated to 80% of the current suggested above when using stranded wires connected to the unit.
Make sure that all strands of each stranded wire enter the terminal connection and the screw terminals are securely fixed to prevent poor contact. If the power supply possesses multi-output terminals, please make sure each contact is connected to wires to prevent too much current stress on a single contact.
-
Use wires that can withstand temperatures of at least 80 °C, such as UL1007.
-
Recommended wire strapping length is 6 mm (0.236”).
-
Recommended screwdriver is 3 mm, slotted type.
-
The recommended torque setting for terminals is shown as below. I/P: 3.4 kgf-cm (3.0 Lb-in). O/P: 5 kgf-cm (4.4 Lb-in).
-
Suggested fuse and maximum number of the power supply units that can be connected to a circuit breaker at 230 V are shown as below. Fuse: T3.15A/H250V. Circuit breaker: C16 – 7, D16 – 14.
-
DIN rail mounting:
Mount as shown in figure only, with input terminals down, or else sufficient cooling will not be possible. Admissible DIN rail: TS35/7.5 or TS35/15.- A. Tilt the unit slightly rearwards.
- B. Fit the unit over top hat rail.
- C. Slide it downward until it hits the stop.
- D. Press against the bottom for locking.
- E. Shake the unit slightly to check the locking action.
Connecting the Power Supply to a Switch
Connect the wires from the power supply to a compatible switch by inserting
the positive and negative wires into the corresponding contacts. Tighten the
wire clamp screws to prevent the wires from being loosened.
Specifications
Hardware
-
Output power: 60W
-
Output power: 48 V DC 1.25 A
-
Input range: stresses 85 V to 264 V AC
-
Input frequency range mains voltage: 47 Hz to 63 Hz
-
Input current: 1.2 A (115 VAC) 0.8 A (230 VAC)
-
Starting current: 30 A (115 V AC) 60 A (230 V AC) Efficiency 91%
Physical parameters
-
Dimensions: (L x W x H) 54.5 x 52.5 x 90 mm
-
Weight: 0.19 kg
Operating conditions
- Mounting options DIN rail mounting Operating temperature: from – rail 30 to +70 °С
- Storage: from rail 40 to +85 °C
- Humidity Operating: 20 to 90% (non-condensing)
- Storage: 10 to 95% (non-condensing)
Technical support
Software updates and documentation available on the website D Link. D-Link provides free customer support for warranty period.
Customers can contact the technical support team D-Link by phone or via the Internet. D-Link technical support works around the clock every day except public holidays. The call is free throughout Russia.
D-Link technical support:
8-800-700-5465
Online technical support: http://www.dlink.ru
e-mail: support@dlink.ru
Authorized representative, importer:
D-Link Trade LLC 390043,
Ryazan, Shabulina Ave., 16
Tel.: +7 (4912) 575-305
Office address in Russia: Moscow, Grafsky lane, 14
Tel.: +7 (495) 744-00-99
e-mail: mail@dlink.ru
**![Logo](https://manuals.plus/wp-content/uploads/2022/03/Screenshot_1-880-550x166.png)
**
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>