GOODWE GW6000-EH EH Series Hybrid Inverter Installation Guide

October 28, 2023
GOODWE

GOODWE LOGO

GOODWE GW6000-EH EH Series Hybrid Inverter

Safety Precautions

General Disclaimer

  • The information in this quick installation guide is subject to change due to product updates or other reasons. This guide cannot replace the product labels or the safety precautions inthe user manual unless otherwise specified. All descriptions here are for guidance only.
  • Before installations, read through the quick installation guide. For additional information, please see the user manual.
  • All operations should be performed by trained and knowledgeable technicians who are familiar with local standards and safety regulations.
  • Check the deliverables for correct model, complete contents, and intact appearance. Contact the manufacturer if any damage is found or any component is missing.
  • Use insulating tools and wear personal protective equipment when operating the equipment to ensure personal safety. Wear anti-static gloves, clothes, and wrist strip when touching electronic components to protect the inverter from damage. The manufacturer shall not be liable for any damage caused by static electricity.
  • Strictly follow the installation, operation, and configuration instructions in this guide and user manual. The manufacturer shall not be liable for equipment damage or personal injury if you do not follow the instructions. For more warranty details, please visit https://en.goodwe.com/warranty.
Safety Disclaimer

Warning

DC Side:

  1. Ensure the component frames and the bracket system are securely grounded.
  2. Connect the DC cables using the delivered PV connectors. The manufacturer shall not be liable for equipment damage if other connectors are used.
  3. Ensure the DC cables are connected tightly, securely, and correctly. Inappropriate wiring may cause poor contacts or high impedances, and damage the inverter.
  4. Measure the DC cable using the multimeter to avoid reverse polarity connection. Also, the voltage should be under the max DC input voltage. The manufacturer shall not be liable for the damage caused by reverse connection and extremely high voltage.
  5. To avoid shock hazards, ensure the minimum impedance of the PV string to the ground exceeds R, R=Max. Input Voltage (V)/30mA.
  6. Keep the battery off, and the inverter disconnects with PV panels and other AC power before connecting the battery and the inverter. The rated voltage of the battery shouldmeet specifications of the inverter.
  7. The PV modules used with the inverter must have an IEC61730 class A rating.

AC Side:

  1. The voltage and frequency at the connecting point should meet the on-grid requirements.
  2. Additional protective devices like circuit breakers or fuses are recommended on the AC side. Specification of the protective device should be at least 1.25 times the maximum AC output current.
  3. PE cable of the inverter must be connected firmly.
  4. You are recommended to use copper cables as AC output cables. If you prefer aluminum cables, remember to use copper to aluminum adapter terminals.

Product:

  1. Do not apply mechanical load to the terminals, otherwise the terminals can be damaged.
  2. All labels and warning marks should be visible after the installation. Do not scrawl, damage, or cover any label on the device.
  3. Do not touch the running equipment to avoid being hurt as its temperature may exceed 60℃. Do not install the equipment at a place within children’s reach.
  4. Unauthorized dismantling or modification may damage the equipment, the damage is not covered under the warranty.
  5. Do not start the BACK-UP function if the inverter is not connected to the battery.
  6. If there is any radio or wireless communication equipment below 30MHz near the inverter, you have to:
    • Install the inverter at least 30m far away from the wireless equipment.
    • Add a low pass EMI filter or a multi winding ferrite core to the DC input cable or AC output cable of the inverter.
  7. Warning labels on the inverter are as follows.

GOODWE GW6000-EH EH Series Hybrid Inverter-1

Check before Power-on

No. Check Item
1 The product is firmly installed at a clean place that is well-ventilated

and easy-to-operate.
2| The PE, DC input, AC output, and communication cables are connected correctly and securely.
3| Cable ties are intact, routed properly and evenly.
4| Unused ports and terminals are sealed.
5| The voltage and frequency at the connection point meet the inverter grid connection requirements.

EU Declaration of Conformity

GoodWe Technologies Co., Ltd. hereby declares that the inverter with wireless communication modules sold in the European market meets the requirements of the following directives:

  • Radio Equipment Directive 2014/53/EU (RED)
  • Restrictions of Hazardous Substances Directive 2011/65/EU and (EU) 2015/863 (RoHS)
  • Waste Electrical and Electronic Equipment 2012/19/EU
  • Registration, Evaluation, Authorization and Restriction of Chemicals (EC) No 1907/2006 (REACH)

GoodWe Technologies Co., Ltd. hereby declares that the inverter without wireless communication modules sold in the European market meets the requirements of the following directives:

  • Electromagnetic compatibility Directive 2014/30/EU (EMC)
  • Electrical Apparatus Low Voltage Directive 2014/35/EU (LVD)
  • Restrictions of Hazardous Substances Directive 2011/65/EU and (EU) 2015/863 (RoHS)
  • Waste Electrical and Electronic Equipment 2012/19/EU
  • Registration, Evaluation, Authorization and Restriction of Chemicals (EC) No 1907/2006 (REACH)
    You can download the EU Declaration of Conformity on https://en.goodwe.com.

LED Indicators

GOODWE GW6000-EH EH Series Hybrid Inverter-2

Introduction

Product Introduction

GOODWE GW6000-EH EH Series Hybrid Inverter-3

  1. DC Switch[1]

  2. PV Input Terminal
    (PV1/PV2)[2]

  3. Battery Terminal (BAT+/-)

  4. Communication Module
    Port (WiFi or LAN)

  5. BMS Communication Port

  6. Meter Communication Port

  7. Back-Up Port

  8. On-Grid Port

  9. DRED Communication Port

  10. RS485 Communication Port

  11. Wi-Fi Reset

  12. Indicators

  13. PE Terminal

  14. Heat Sink

  15. Mounting Plate
    [1][2] Only for EH Series & EH Plus Series.

Dimensions

Inverter Installation

GOODWE GW6000-EH EH Series Hybrid Inverter-5

N = Quantity depends on the inverter model.
[1] Only for EH series and EH Plus series.

Space Requirements

GOODWE GW6000-EH EH Series Hybrid Inverter-6

GOODWE GW6000-EH EH Series Hybrid Inverter-7

Angle Requirements

GOODWE GW6000-EH EH Series Hybrid Inverter-8

Installing the Inverter

GOODWE GW6000-EH EH Series Hybrid Inverter-9

Electrical Connection

PE Cable

GOODWE GW6000-EH EH Series Hybrid Inverter-10

AC Cable (ON-GRID)

GOODWE GW6000-EH EH Series Hybrid Inverter-11

AC Cable (BACK-UP)

GOODWE GW6000-EH EH Series Hybrid Inverter-12

DC Cable (PV)

  • Only for EH Series & EH Plus Series.

GOODWE GW6000-EH EH Series Hybrid Inverter-13

GOODWE GW6000-EH EH Series Hybrid Inverter-14

Battery Cable (BATTERY)

Phoenix

GOODWE GW6000-EH EH Series Hybrid Inverter-15

MC4

GOODWE GW6000-EH EH Series Hybrid Inverter-16

Vaconn

GOODWE GW6000-EH EH Series Hybrid Inverter-17

Communication Connection

  • DRED: for Australia and New Zealand.

GOODWE GW6000-EH EH Series Hybrid Inverter-18

Remote Shutdown Communication Cable

GOODWE GW6000-EH EH Series Hybrid Inverter-19

Connecting BMS or Smart Meter or RS485

GOODWE GW6000-EH EH Series Hybrid Inverter-20

Communication Module

Power On and Off

Recommended Circuit Breaker

EH Series & EH Plus Series

Model 1 2 3 4 5
GW3600-EH/GW3600N-EH 40A/600V DC Isolator 50A/230V AC Breaker Depends on

loads
GW5000-EH/GW5000N-EH| 50A/230V AC Breaker
GW6000-EH/GW6000N-EH| 63A/230V AC Breaker

BH Series

Model 1 2 3 4 5
GW3K-BH

40A/600V DC

Isolator

| 50A/230V AC Breaker| 32A/230V AC Breaker|

Depends on loads

GW3600-BH| 50A/230V AC Breaker| 32A/230V AC Breaker
GW5000-BH| 63A/230V AC Breaker| 32A/230V AC Breaker
GW6000-BH| 63A/230V AC Breaker| 40A/230V AC Breaker

EH Series & EH Plus Series

GOODWE GW6000-EH EH Series Hybrid Inverter-24

BH Series

GOODWE GW6000-EH EH Series Hybrid Inverter-25

Commissioning and Monitoring

Commissioning via PV Master APP

GOODWE GW6000-EH EH Series Hybrid Inverter-26

Monitoring via SEMS Portal App

GOODWE GW6000-EH EH Series Hybrid Inverter-27

For more detailed instructions, scan the QR codes below.

GOODWE GW6000-EH EH Series Hybrid Inverter-28

GoodWe Technologies Co., Ltd.
No. 90 Zijin Rd., New District, Suzhou, 215011, China
www.goodwe.com
service@goodwe.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals