HTR230(20) is a surface-mounted (or on a flush-box) room thermostat dedicated for surface heating/cooling control, characterized by high thermal inertia. It is connected to the wiring center, through which you can lower the set temperature on it, receiving a signal NSB (night temperature reduction) from the weekly thermostat. The room temperature could be set by knob use. Thanks to the built-in algorithms, it offers much better temperature control accuracy than traditional mechanical thermostats. The thermostat is characterized by silent operation.
Product compliance
The product complies with the following EU directives: 2014/30/EU, 2014/35/EU, 2011/65/EU. Full information is available at www.saluslegal.com
Note!
This document is a quick guide to the installation and operation of the
product and indicates its main features and functions. Detailed information is
available in the full manual, which is available at
www.Saluscontrols.eu and must be used for
proper installation and operation of the product.
SAFETY INFORMATION
Use in accordance with national and EU regulations. Use the device as intended
and keep it dry. Product for indoor use only. Please read the entire manual
before starting the installation and using the product.
INSTALLATION
Installation must be carried out by a qualified person, with appropriate
electrical authorizations, in accordance with national and EU standards and
regulations. The manufacturer shall not be liable for failure to comply with
the manual.
NOTE
There may be additional protection requirements for the entire installation.
The installer shall be responsible for compliance with such requirements.
Package content
**Proper thermostat location
**
The ideal position for thermostat mounting is about 1,5m under floor level far from heating or cooling sources. In addition, the thermostat should not be installed behind curtains or other obstacles or in places with high humidity, as this will prevent accurate measurements of room temperature. The thermostat must not be exposed to sunlight. Do not place the thermostat on an outer wall.
**Connection description
**
Note: The thermostat is compatible with the following Salus wiring center models: KL06 230V, KL08NSB 230V, KL04NSB 230V, or directly to the actuator.
Symbols explanation
Terminal | Description |
---|---|
L, N | Power supply (230V AC) |
NSB | Night temperature reduction (230V output) |
SL | 230 V AC output signal |
CO | Switching jumper between heating and cooling (input 230V AC) |
Montage
- Make sure that the thermostat is not connected to the 230V AC. Remove the knob by pulling it towards you, and then open the front cover as shown in the figure above.
- Connect the thermostat. Please refer to the “Connection Description” section. Mount the thermostat using the designed screw holes.
- Fold front and back housing of thermostat. The thermostat is configured. Use the knob to set the temperature setpoint.
**Jumpers for additional settings
**
The functions of the HTR230(20) thermostat can be switched on and off by
jumpers. Please refer to the table below:
Jumpers 1 to 5 correspond to the number of actuators connected. This jumper is
factory set to position 1, which means that the thermostat controls one
actuator. Depending on the number of actuators used, the jumper position must
be changed to ensure optimal operation of the temperature thermostat.
Selecting the heating or cooling mode
The heating or cooling mode is based on the voltage sent to the CO terminal.
0V AC at the CO terminal – the thermostat is in heating mode. 230V AC at the
CO contact – the thermostat is in cooling mode.
Cooling blocking function
Cooling on: Set the jumper to ON. The thermostat will work in cooling mode if 230V AC will appear at the CO terminal. The LED lights up blue when the thermostat sends a signal for cooling.
Night setback – NSB function
The NSB (Night Set Back) function enables automatic reduction of the
temperature setpoint on the daily thermostats, via the programmable thermostat
connected to the wiring center. The temperature change takes place between day
and night temperatures. When the night mode is activated, the programmable
thermostat sends a voltage signal to the daily thermostats via the wiring
center. Then, the HTR230(20) thermostat automatically reduces the temperature
setpoint on the knobby 2° or 4° (as set on the SETBACK jumper). In heating
mode, the temperature is lowered when 230 V AC voltage appears at the NSB
input.
Note: For the proper NSB function work, an appropriate cable connection is required. the connection description is on the previous page.
Valve Protection
Set the jumper to ON – to enable or OFF – to disable the function. This
function activates the thermostatic valve for 5 minutes once a week to prevent
the valve from stuck (caused by limescale).
Operation algorithm selection
The thermostat gives a possibility to choose the mode of controlling the room
temperature by PWM algorithm (default) or hysteresis +/-0.5°C. The PWM
algorithm is designed for underfloor heating (for heating systems with high
inertia) – to precisely maintain the room temperature.
Technical information
Power supply | 230V AC 50 Hz |
---|---|
Max. load | TRIAC 0.5 A |
Output signal | 230V AC 50 Hz |
Temperature control range | 5 – 30°C |
Control method | PWM or Hysteresis: ±0.5°C |
Communication | Wired |
Dimension [mm] | 85 x 85 x 30 |
SALUS CONTROLS DISTRIBUTOR: QL CONTROLS Sp. z o.o., Sp. k. ul. Rona 4, 43-262 Kobielice, Poland Importer: SALUS Controls Plc Units 8-10 Northfield Business Park Forge Way, Parkgate Rotherham S60 1SD United Kingdom
www.Salus-controls.eu
SALUS Controls is a member of the Computime Group. In accordance with the
product development policy, SALUS Controls plc reserves the right to change
specifications, design, and materials used in production, presented in this
manual, without prior notice.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>