VISUAL COMFORT Co 14PRR62BSD Ceiling Fan Instruction Manual
- June 12, 2024
- VISUAL COMFORT Co
Table of Contents
FAN COLLECTION
14PRR62XXXD Series Fan
cETL Model NO. : 14PRR62(X)
Total fan weight with light: 11 kg/24.2 lbs
**Cautions and Warnings
**
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING READ AND SAVE THESE INSTRUCTIONS
Installation work and electrical wiring must be done by qualified person(s) in
accordance with applicable codes and standards (ANSI/NFPA 70), including fire-
rated construction.
Use this unit only in the manner intended by the manufacturer. If you have any
questions contact the manufacturer.
After making the wire connections, the wires should be spread apart with the
grounded conductor and the equipment-grounding conductor on one side of the
outlet box and ungrounded conductor on the other side of the outlet box. The
splices, after being made, should be turned upward and pushed carefully up
into the outlet box.
WARNING: Before you begin installing the fan, servicing or cleaning unit,
Switch power off at Service panel and lock service disconnecting means to
prevent power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
Be cautious! Read all instructions and safety information before
installing your new fan. Review the accompanying assembly diagrams.
When cutting or drilling into wall or ceiling, do not damage electrical wiring
and other hidden utilities.
Make sure the installation site you choose allows the fan blades to rotate
without any obstructions. Allow a minimum clearance of 7 feet from the floor to
the trailing edge of the blade.
WARNING: To Reduce The Risk Of Fire, Electric Shock, or Personal Injury,
Mount To Outlet Box Marked “Acceptable for Fan Support of 15.9 kg (35 lbs) or
less” And Use Mounting Screws Provided With The Outlet Box.
WARNING: To reduce the risk of personal injury, do not bend blade holders
during installation to motor, balancing or during cleaning. Do not insert
foreign object between rotating blades.
CAUTION: For Compliance with Local Codes and Regulations, If Installing
The Secondary Support Safety Cable in the U.S., Do Not Remove Knockouts In The
Outlet Box. Mount the secondary support safety cable through the reserved
nail/screw hole on the outlet box to the building structure (or the ceiling
joist).
Attach the mounting bracket using only the hardware supplied with the outlet
box.
WARNING: To Reduce The Risk Of Electric Shock, This Fan Must Be Installed
With a general use, isolating Wall Control/Switch.
WARNING: To reduce the risk of fire or electric shock, this fan should
only be used with fan speed control part no. DC8 manufactured by Carewell
Electric Technology (Zhongshan) Co.,Ltd.
WARNING: To reduce the risk of fire or electric shock, do not use this fan
with any other solid state fan speed control device, or variable speed
control.
If this unit is to be installed over a tub or shower, it must be marked as
appropriate for the application.
Never place a switch where it can be reached from a tub or shower.
The combustion airflow needed for safe operation of fuel-burning equipment may
be affected by this unit’s operation. Follow the heating equipment
manufacturer’s guideline safety standards such as those published by the
National Fire Protection Association (NFPA), and the American Society for
Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local
code authorities.
CAUTION: To Reduce the Risk of Electric Shock, Disconnect the electrical
supply circuit to the fan before installing the light kit.
CAUTION: The light source is designed for this specific application and
can overheat if serviced by untrained personnel. If any servicing is required,
the product should be returned to an authorized service facility for
examination or repair.
All set screws must be checked, and re-tightened where necessary, before
installation.
Note: Suitable for use in damp locations. Install the fan under covered
or enclosed patios or porches.
Tools Required for Assembly (not included): Electrical Tape, Phillips
Screwdriver, Pliers, Safety Glasses, Stepladder and Wire Strippers
Customer Service
847.410.4400
Customer Service Center
7400 Linder Ave.
Skokie, IL 60077
www.visualcomfort.com
-
Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel. Use AC 120V/60HZ power supply only.
-
Before installing this fan make sure the outlet box is properly installed to the house structure. To reduce the risk of fire, electric shock, or personal injury, mount to outlet box or supporting system acceptable for fan support. (Mounting must support at least 35 lbs.)
-
Use metal outlet box suitable for fan support and use only the screws provided with the outlet box (must support 35 lbs). Before attaching fan to outlet box, ensure the outlet box is securely fastened by at least two points to a structural ceiling member (a loose box will cause the fan to wobble). Remove the two outlet box screws provided with the box, aligning the holes of the mounting bracket with the holes of the outlet box. Reinstall the 2 outlet box screws securely.
-
Remove preassembled keeper pin and cross pin from downrod.
-
Place downrod over canopy, canopy bottom cap and yoke cover
-
Partially loosen downrod set screws from yoke at top of motor assembly. Thread lead wires and safety cable from motor assembly through downrod. Helpful hint: For easy assembling of the cross pin on the next installation step. After slip downrod into the motor yoke, carefully insert a Phillips screwdriver through the yoke and downrod (don’t damage the lead wires) as a guide and then push the cross pin and pull the screwdriver in the meantime as shown in the inset.
-
Slip downrod into motor housing yoke, aligning holes and install cross pin and keeper pin.
Insert cross pin through yoke and downrod until point appears on the other side, and insert keeper pin on cross pin.
Pull the downrod up tight against the cross pin, and then evenly tighten the downrod set screws on motor housing yoke.
Place Yoke cover on motor assembly.
Warning: Cross pin and keeper pin must be installed securely, failure to install them will result in serious injury. -
Install ball end of downrod into mounting bracket opening. Align (engage) slot on ball with tab on mounting bracket.
Warning: Failure to align slot on ball with tab may result in serious injury.
Important: If using the angle mount, make sure open end of mounting bracket is installed facing the higher point of the ceiling and make sure the ceiling angle is not steeper than 20º. -
Safety cable must be installed into the house structure using 3” lag screws, washers, and lock washers provided, required for outdoor applications and in Canada (All fans installed in Canada), and for USA fan and light kit combinations over 35lbs.
Make sure that when the safety cable is fully extended the lead wires are longer than the cable and no stress is placed on the lead wires.
Note: If Installing The Secondary Support Safety Cable in the U.S., Do Not Remove Knockouts In The Outlet Box. -
Make wiring connections using wire connectors provided as indicated above.
Red from fan to Red from remote marked Motor 1.
Purple from fan to Purple from remote marked Motor 2.
Gray from fan to Gray from remote marked Motor 3.
Blue from fan to Blue from remote marked FOR LIGHT.
White from fan to White from remote marked FOR LIGHT.
White (Neutral) from house to White from remote marked AC IN N.
Black (Live) from house to Black from remote marked AC IN L.
Connect all green grounded wires to Grounded wire from House.
Make sure that no filaments are outside of the wire connectors.
Insert the remote receiver into mounting bracket.
Insert the remote receiver into mounting bracket.
After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box. The splices after being made should be turned upward and pushed carefully up into the outlet box.
Caution: The installation has to be complete before operate the fan. Receiver has to be used on the fan and cannot be bypassed. -
Partially loosen one and remove one preassembled screw from mounting bracket. Save screw.
-
Lift canopy up, aligning its keyhole slot with the preassembled screw on mounting bracket and twist counterclockwise to lock in place. Reinstall the screw removed in step 11 and tighten all screws securely. Attach canopy bottom cap onto canopy by aligning its notch with the screws on mounting bracket and twist clockwise till tight.
-
Install blades, aligning the holes of blade bracket and blade.
Install blade bracket with blade by blade setscrews and washers provided. Tighten screws securely. Repeat this process for remaining blades. -
Install the blade assembly to motor using the preinstalled screws. Tighten screws securely. Repeat this process for remaining blade assemblies.
-
Loosen 2 and remove 1 preassembled screw from the plate on motor. Save screw for later use.
-
Place light pan over the light lead wires and attach it onto the plate on motor, aligning the keyhole slots on the light pan with the preassembled screws on the plate. Twist clockwise till lock. Reinstall the screw removed in step 15. Tighten all screws securely.
-
Remove 3 preassembled screw from the light pan. Save screws for later use.
Install LED Light Kit
-
Connect white wire from fan to white wire from LED module and then connect blue (or black) wire from fan to blue (or black) wire from LED module.
Note: If you don’t want to install the fan with LED light, go to step 20 for blanking plate installation. -
Attach LED light kit onto the light pan, aligning the holes on the LED light kit with the screw holes on light pan. Reinstall the screws removed in step 17. Tighten all screws securely.
Install Blanking Plate
- Attach blanking plate by locating dimples in light pan with grooves on the blanking plate and twist clockwise until tight. Note: Do not install LED light kit if use blanking plate.
REMOTE CONTROL SETTING and OPERATION
Transmitter Operation
Remove the battery cover from the remote control transmitter and install
battery, battery provided. Replace the cover.
Note: Use 2 1.5V/AAA battery.
Note: If not using for long period of time, remove battery to prevent
damage to remote transmitter, and store the remote transmitter away from
excess heat or humidity.
Dimming / Non Dimming Setting
The “DIM” selection is the light dimmable selection and the light will cycle
from bright to dim to bright until button is released. The “ON” selection is
the light ON/OFF only (non dimming function). Light will maintain last setting
if turned off.
Note: The remote controller is set with dimming function at factory,
Note: If the remote receiver has been wired with fan, turn power off by
wall switch before switch “DIM” and “ON/OFF” selection.
Universal Mode and Learning Mode
There are “Universal Mode” and “Learning Mode” with the remote controller.
If choosing “Universal Mode”, simply place dip (code) switch at UPPER
position. Your fan with the remote controller is ready to use.
Note: If using universal mode, your fan can be controlled with other
remote transmitters with the same setting.
To control the fan with specific remote transmitter, choose “Learning Mode” by
placing the dip (code) switch at LOWER position and then make learn function
setting as below.
Learn function setting
Important: Turn the power on for ONLY the specific fan you wish to pair
with the remote controller. Make sure to turn the power off for all other fans
with which you use the same remote controller.
Restore power source to your fan, press and hold the “LEARN” button for at
least 3 seconds. You must press the “LEARN” button within 60 seconds of
restoring power to the fan.
Note: If the power is on already, you must turn the power off for 10
seconds at least, and then turn the power back for remote control learn
function setting.
Note: If the fan is installed with light, light will twinkle 2 times. The
remote control setting process is complete and your fan is ready for use. For
fans without light, check operation using remote transmitter.
Note: If you want to control the fan with another transmitter, make the
same setting. A fan can be controlled by 2 transmitters maximum.
The receiver provides the following protective functions
Lock protection- The DC motor has a build-in safety feature against blade or
motor obstruction during operation. If something obstructs the fan blades or
motor, the motor will keep trying to run for 5 times and then stop operation
after about 60 seconds of interruption. Please remove obstacles and reset. To
reset it by turn the fan off by remote transmitter and then turn the fan on,
Or you may turn power off for 15 seconds then turn power back, and then turn
the fan on,
Over load protection (current limit)- The device will limits the maximum
current output from the receiver/drive when the fan or light load was
increased abnormally.
The remote control buttons control the fan speed as follows:
Fan speed
- minimum speed
- low speed
- medium low speed
- medium speed
- medium high speed
- high speed
This button turns the fan off.
Forward/Reverse button- This button is to control direction of fan rotation.
Press once to change direction of the fan rotation. Fan must be running to
reverse.
Light button- Press this button to turn light on or off. To dim light (Setting
at “DIM” position), hold down the button, the light will cycle from bright to
dim to bright until button is released.
Note: This remote controller has auto resume function, the fan and light
will maintain the last setting if power is turned off.
Wall mount cradle installation
Install Transmitter wall mount cradle with 2 screws provided.
User Tips
-
If your fan is operating automatically after installation, it is still using the factory setting. Follow the settings for Learn Mode above to reset.
-
If the fan or light isn’t working, reset power (turn the power off then turn the power back on) and follow the Universal Mode or Learn Mode remote control settings.
If you want to change it back to Universal Mode from Learn Mode, and you have made the Lean Mode setting twice, you will need to make the same Learn Mode setting on Universal Mode. -
If two or more fans in the same remote signal range are on the same power supply, they cannot be operated separately by remote control. Use a separate power supply for each fan, such as an individual wall switch, and restrict the power supply to only the fan which you are pairing with its transmitter in order to use the remote controller.
-
When the fan is turned on to oscillate in either forward or reverse direction, it may shudder briefly until fully engaged. This is a normal operation for this fan; the shuddering will quickly cease as movement is engaged.
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS. (1)THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
Troubleshooting
If you have difficulty operating your new ceiling fan, it may be the result of
incorrect assembly, installation, or wiring. In some cases, these installation
errors may be mistaken for defects. If you experience any faults, please check
this Troubleshooting Chart. If a problem cannot be remedied, or you are
experiencing difficulty in installation, please call our Customer Service
Center at the number printed on your parts list insert sheet.
Warning: Before you begin installing, servicing or cleaning the fan unit,
switch the power off at the service panel and lock the service panel to
prevent the power from being switched back on accidentally. If the service
panel cannot be locked to prevent the power from being switched on
accidentally, securely fasten a warning sign to the service panel.
Trouble | Suggested Remedy |
---|---|
1. If fan does not start: | 1. Check main and branch circuit fuses or circuit |
breakers.
2. Check line wire connections to fan and switch wire connections in switch
housing.
CAUTION: Make sure main power is turned off.
3. If this fan uses manual forward/reverse switch, make sure the switch is
pushed firmly either way. Fan will not operate when switch is in the middle.
4. If this fan uses a remote controller, make sure dip switches are in the
correct setting and make sure the battery works.
2. If fan sounds noisy:| 1. Check to make sure all screws in motor housing
are snug (not over tightened).
2. Check to make sure the screws which attach the fan blade holder to the
motor are tight.
3. Check to make sure wire nut connectors in switch housing are not rattling
against each other or against the interior wall of the switch housing.
CAUTION: Make sure main power is turned off before entering switch
housing.
4. Check to be sure lightbulb is tight in socket and not touching the glass
shade.
5. Some fan motors are sensitive to signals from Solid State variable speed
controls.
6. Allow “break-in” period of 24 hours. Most noises associated with a new fan
will disappear after this period.
3. If fan wobbles:| 1. If this is a downrod mount fan, make sure the ridge
on mounting bracket engages the notch in the downrod ball.
2. Make sure that canopy, mounting bracket or mounting plate are tightened
securely to ceiling junction box and junction box is mounted firmly to ceiling
joist.
3. Check that all blades are screwed firmly into blade holders.
4. Check that all blade holders are tightened securely to motor.
5. Most fan wobble problems are caused when blade levels are unequal. Check
this level by selecting a point on the ceiling above the tip of one of the
blades. Measure this distance from blade tip to ceiling. Keeping measure
within 1/8″, rotate the fan until the next blade is positioned for
measurement. Repeat for each blade. If all blade levels are not equal, you can
adjust blade levels by the following procedure. To adjust a blade tip down,
insert a washer (not supplied) between the blade and blade holder at the screw
closest to the motor. To adjust a blade tip up, insert washer (not supplied)
between the blade and blade holder at the two screws farthest from the motor.
Reverse the position of the washer if blades mount from top of blade.
6. If blade wobble is still noticeable, interchanging two adjacent blades can
redistribute the weight and possibly result in smoother operation.
If the above steps do not eliminate the wobble problem, you will need to
dynamically balance your fan with balancing kit provided.
4. If light does not work:| 1. Check blue wire from fan to make sure it is
connected to hot wire from house.
2. Check for loose or disconnected wires in fan switch housing.
3. Check for loose or disconnected wires in light kit.
4. Check for faulty lightbulb and make sure bulb is tight in socket.
5. Remove light kit and check the plug connections if they are present.
6. If this fan uses a remote controller, make sure dip switches are in the
correct setting and make sure the battery works.
CAUTION: Make sure main power is turned off before entering switch
housing and/or canopy.
Oct.2017
Jan.2018 update ETL listed model number and file number
Jun.2020 branding
Aug.2021 remote control wording
Jan.2023 VCC_FAN
© 2023 Visual Comfort & Co.. All rights reserved. The Visual Comfort & Co.
logo is a registered trademark of Visual Comfort & Co.
Visual Comfort & Co. reserves the right to change specifications for product
improvements without notification.
7400 Linder Ave., Skokie, IL 60077
T 847.410.4400 F 847.410.4500
www.visualcomfort.com
Documents / Resources
|
VISUAL COMFORT Co 14PRR62BSD Ceiling
Fan
[pdf] Instruction Manual
14PRR62BSD, 14PRR62AGPD, 14PRR62XXXD Series Fan, 14PRR62BSD Ceiling Fan,
Ceiling Fan, Fan
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>