MOXA ioLogik E2200 Series Smart Ethernet Remote Installation Guide
- June 6, 2024
- MOXA
Table of Contents
ioLogik E2200 Series Smart Ethernet Remote
Installation Guide
Package Checklist
- 1 ioLogik E2200 series remote I/O product
- Quick installation guide (printed)
- LDP1602 LCD Module (Optional)
Specifications
Ethernet Interface
10/100BaseT(X) Ports (R)45 connector)| 1
Magnetic Isolation Protection| 1.5 kV (built-in)
Ethernet Software Features
Configuration Options| Web Console (HTTP), Windows Utility
Industrial Protocols| CGI commands, Modbus TCP Server (Slave), Moxa AOPC
(Active Tag), MXIO Library, SNMPv1 Trap, SNMPv1/v2c/v3
Management| ioAdmin, BootP, IPv4, SMTP, DHCP Client, HTTP, Web Console, TCP/IP
MIB| Device Settings MIB
Time Management| SNTP
Serial Interface
Baudrate| 1200 bps to 115,200 kbps
Connector| Terminal block
No. of Ports| 1
Parity| None
Serial Standards| RS-485
Stop Bits| 8
Serial Signals
RS-485-2w| Data+, Data-, GND
Power Parameters
Input Voltage| 12 to 36 VDC
No. of Power Inputs| 1
Power Connector| 1 removable 6-contact terminal block
Power Consumption| ioLogik E2210 Series: 202 mA @ 24 VDC
ioLogik E2212 Series: 136 mA @ 24 VDC
ioLogik E2214 Series: 170 mA @ 24 VDC
ioLogik E2240 Series: 198 mA @ 24 VDC
ioLogik E2242 Series: 178 mA @ 24 VDC
ioLogik E2260 Series: 95 mA @ 24 VDC
ioLogik E2262 Series: 160 mA @ 24 VDC
Physical Characteristics
Dimensions| 115 x 79 x 45.6 mm (4.53 x 3.11 x 1.80 in)
Weight| 250 g (0.55 lb)
Installation| DIN-rail mounting, wall mounting
Wiring| I/O cable, 16 to 26 AWG Power cable, 16 to 26 AWG
Environmental Limits
Operating Temperature| Standard Models: -10 to 60°C (14 to 140°F) Wide Temp.
Models: -40 to 75°C (-40 to 167°F)
Storage Temperature (package included)| -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity| S to 950/0 (non-condensing)
Altitude| 2000 m (Please contact Moxa if you require products guaranteed to
function properly at higher altitudes.)
LED Indicators
LED | Light | Description |
---|---|---|
PWR | Off | System power off |
Red | System power on | |
RDY | Off | System not ready |
Green | System ready | |
Red | System error | |
Green, blinking | Click & Go running | |
Green/Red, blinking | System in Safe mode | |
Serial | Off | Serial port not connected |
Red | Serial port connected | |
Blinking | Data sending and receiving | |
Ethernet | Off | Ethernet port not connected |
Amber | 10 Mbps connected | |
Green | 100 Mbps connected | |
Blinking | Data sending and receiving | |
DI | Off | DI status off |
Green | DI status on | |
DO | Off | DO status off |
Red | DO status on | |
DIO | Off | DI or DO status off |
Green | DI mode and status on | |
Amber | DO mode and status on | |
AI | Off | AI channel disabled |
Transmitter not connected when in 4 to 20 mA mode
Green| AI channel enabled
RTD| Green| RTD status on
Red| RTD transmitter not connected
TC| Green| TC status on
Red| TC transmitter not connected
DO Power| Off| External power off or not connected
Red| External power on
I/O Wiring Diagrams
Contact Type | Power Source Requirement |
---|---|
Dry Contact | A dry Contact does not need to be connected to a power source to |
function properly.*
Wet Contact| A wet Contact must be connected to a power source to function
properly.
*Some users connect dry contacts to a power source for added stability.
Depending on your application, you can decide whether or not to connect your
dry contacts to power sources.
Mounting
There are two ways to mount the ioLogik E2200 Series: DIN rail or wall mounting.
-
Mounting on a DIN rail
Pull out the bottom slider; latch the unit onto the DIN rail, and then push the slider back in. -
Mounting on a wall
Pull out both the top and bottom sliders and align the screws accordingly. The heads of the screws should be less than 6.0 mm in diameter, and the shafts should be less than 3.5 mm in diameter, as shown in the figure.
Connecting to the ioLogik E2200
You have two ways to connect to the ioLogik E2200: by admin or by web console.
- Default IP Address: 192.168.127.254
- Subnet Mask: 255.255.255.0
NOTE Be sure to configure the host PC’s IP address to the same subnet as the ioLogik E2200. For example, 192.168.127.253
Restore Factory Defaults
There are three ways to restore the ioLogik to factory default settings.
- Hold the RESET button for 5 seconds.
- Right-click on the specific ioLogik in the admin utility and select Reset to Default.
- Select Load Factory Default from the web console.
NOTE Refer to the user’s manual for detailed configuration and settings information.
How to Download the Software
Step 1: Click on the following link to open the Support & Downloads
search tool: http://www.moxa.com/support/support_home.aspx?isSearchShow=1
Step 2: Type the model name in the search box or select a product from the
drop-down box and then click Search.
Step 3: Click the Software Packages link to download the latest software for the product.
www.moxa.com/support
P/N: 1802022000011