MOXA DRP Series DIN Rail Computer Installation Guide

June 1, 2024
MOXA

DRP Series DIN Rail Computer

“`html

Specifications

  • Model: DRP Series
  • Version: 1.1
  • Release Date: November 2023
  • Manufacturer: Moxa Inc.
  • Support Contact: www.moxa.com/support
  • Package Contents: Refer to the Package Checklist

Product Overview

The DRP Series computers are designed for industrial use with
various models catering to different requirements. The panel
layouts provide a clear visual representation of the different
models available.

Package Checklist

Ensure all items listed in the package checklist are included
and in good condition. Notify your sales representative if any
items are missing or damaged.

Panel Layouts

The panel layouts showcase the front, top, and bottom views of
different DRP Series models. Refer to the specific layout for your
model for easy identification.

LED Indicators

LED Name Power Ethernet (10/100 Mbps) Ethernet (1000 Mbps) Status
Power Green OFF Green Yellow
Ethernet (CFast) OFF Yellow OFF

Installing the DRP Computer

DIN-rail Mounting

  1. STEP 1: Check the preinstalled DIN-rail
    bracket on the rear panel of the DRP computer.

  2. STEP 2: Insert the DIN rail into the slot
    below the upper hook of the mounting bracket.

  3. STEP 3: Press the computer towards the DIN
    rail until it snaps into place.

Removal:

  1. STEP 1: Pull down the latch on the mounting
    bracket with a screwdriver.

  2. STEP 2 & 3: Gently pull the computer
    forward and lift it up to unmount it from the DIN rail.

Note: Installation should be done by qualified
professionals in restricted access areas for safety reasons.

FAQ (Frequently Asked Questions)

Q: Can I install the DRP Series computer in a
non-industrial setting?

A: The computer is intended for industrial use
and should be installed accordingly for optimal performance and
safety.

Q: How do I know if my DRP computer is properly
mounted on the DIN rail?

A: Ensure that the mounting bracket snaps into
place securely, and there are no loose connections between the
computer and the DIN rail.

“`

DRP Series Quick Installation Guide
Version 1.1, November 2023
Technical Support Contact Information www.moxa.com/support
2023 Moxa Inc. All rights reserved. P/N: 1802001004011 1802001004011

Overview
The DRP series DIN-rail computers are powered by an Intel Atom®, Intel® Celeron®, or Intel® CoreTM i5/i7 processor. The computers come with a rich set of interface options including up to 8 softwareselectable RS-232/422/485 serial ports and up to 10 gigabit Ethernet ports. The communication interfaces are located on the front and rear sides of the product, enabling easy access and expansion for industrial applications. A dual-storage design that includes CFast and SD slots enables easy storage expansion. The unique battery fastener cover design for the battery slot secures the battery in place and ensures stability in all operating environments. Designed as compact fanless computers with operating temperature range of -30 to 60°C and built-in TPM 2.0 module, the DRP computers are ideal as reliable and secure computing platforms for both IT/ OT applications in extreme operating environments.
Package Checklist
Before installing the DRP Series, verify that the package contains the following items: · DRP series computer with DIN-rail bracket attached · 2-pin terminal block for DC power · Quick installation guide (printed) · Warranty card
NOTE Please notify your sales representative if any of the above items are missing or damaged.
Panel Layouts
The panel layouts of the DRP series computers are shown below: DRP-C100-T/C1-T/C5-T/C7-T/C1-T-Win10/C5-T-Win10/C7-TWin10 Models
Front View
– 2 –

Top View

Bottom View

DRP-C100-L-T/C1-8L-T/C5-8L-T/C7-8L-T Models Front View

Top View

Bottom View

– 3 –

DRP-C100-C-T/C1-6C-T/C5-6C-T/C7-6C-T Models Front View

Top View

Bottom View

DRP-C100-C1-2L4C-T/C5-2L4C-T/C7-2L4C-T Models Front View

– 4 –

Top View

Bottom View

DRP-A100-T/E2-T/E4-T/E2-T-Win10/E4-T-Win10 Models Front View

Top View

Bottom View

– 5 –

DRP-A100-L-T/DRP-A100-E2-8L-T/E4-8L-T Models Front View

Top View

Bottom View

– 6 –

DRP-A100-C-T/DRP-A100-E2-6C-T/E4-6C-T Models Front View

Top View

Bottom View

– 7 –

DRP-A100-E2-2L4C-T/E4-2L4C-T Models Front View

Top View

Bottom View

– 8 –

Dimensions
DRP-C100-T/C1-T/C5-T/C7-T/C1-T-Win10/C5-T-Win10/C7-TWin10 Models DRP-A100-T/E2-T/E4-T/E2-T-Win10/E4-T-Win10 Models
DRP-C100-L-T/DRP-C100-C1-8L-T/C5-8L-T/C7-8L-T Models DRP-A100-L-T/DRP-A100-E2-8L-T/ E4-8L-T Models
– 9 –

DRP-C100-C-T/C1-6C-T/C5-6C-T/C7-6C-T Models DRP-A100-C-T/DRP-A100-E2-6C-T/E4-6C-T Models
DRP-C100-C1-2L4C-T/C5-2L4C-T/C7-2L4C-T Models DRP-A100-E2-2L4C-T/E4-2L4C-T Models
– 10 –

LED Indicators

The following table describes the LED indicators located on the front panel of the DRP Series:

LED Name Power
Ethernet (10/100 Mbps) (1000 Mbps)

Status Green OFF Green
Yellow

Storage (CFast)

OFF Yellow
OFF

Function Power is ON No power input or any other power error Steady ON: 10/100 Mbps Ethernet link Blinking: Data is being transmitted or received Steady ON: 1000 Mbps Ethernet link Blinking: Data is being transmitted or received No Ethernet connection Blinking: Data is being accessed from the CFast card Data is not being accessed from the CFast card

Installing the DRP Computer
DIN-rail Mounting The DRP computers come with a DIN-rail bracket attached. To install the computers on to a DIN rail, do the following: STEP 1: Check the DIN-rail bracket that comes preinstalled on the rear panel of the DRP computers.

STEP 2: Insert the top of the DIN rail into the slot just below the upper hook of the DINrail mounting bracket.
STEP 3: Press the DRP computer towards the DIN rail until the mounting bracket snaps into place.

– 11 –

Removal:
STEP 1: Pull down the latch on the mounting bracket with a screwdriver.
STEP 2 & 3: Slightly pull the DRP computer forward and lift it up to unmount it from the DIN rail.
The specifications of the DIN-rail bracket mounting screws are shown in the illustration on the right. Adhere to these values if you need to buy replacement screws to attach and secure the DIN-rail bracket to the rear panel of the computer.

NOTE

This computer is intended to be installed only in an area with restricted access. In addition, for safety reasons, the computer should be installed and handled only by qualified and experienced professionals.

Connecting the Power
The DRP computers are provided with 2-pin power input connectors in a terminal block on the front panel. Insert the power-cord wires into the connectors and tighten them to secure the wires in place. Plug in the power cable to a power source. The power LED will light up to indicate that power is being supplied to the computer. It should take about 30 to 60 seconds for the operating system to complete the boot-up process.

Pin Definition

1

V+

2

V-

– 12 –

ATTENTION
This product is intended to be supplied by a Listed Power Supply with output marked LPS and rated to deliver the following power specifications: DRP-C100:12 VDC @ 6.82 A, 24 VDC @ 3.25 A DRP-A100: 12 VDC @ 5 A, 24 VDC @ 2.5 A and a minimum Tma=60°C. If you need assistance with purchasing a power adapter, contact the Moxa technical support team.

ATTENTION
Before connecting the DRP computer to the DC power input, ensure that the DC power source voltage is stable. · The wiring for the input terminal block must be installed by
qualified and experienced professionals. · Wire Type: Cu, FW2 · Use 18-12 AWG wire size and a torque value of 0.51 N-m
· Use only one conductor in a clamping point between the DC power source and the power input.

NOTE If using Class I adapter, the power cord adapter should be connected to a socket outlet with an earthing connection or the power cord and adapter must comply with Class II construction.

NOTE

For surge protection, connect the grounding connector located below the power connector with the earth (ground) or a metal surface. A 4 mm2 conductor must be used when the connection to the external grounding screw is utilized. The heat sink is grounded to the chassis by an internal screw.

Warning: Hot Surface
External metal parts of this equipment are hot!! Before touching the equipment, you must take special precautions to protect your hands and body from serious injury.

Warning

– 13 –

Connecting Displays
The DRP computer comes with a VGA and a HDIM display output located on the front panel for connecting to audio or video devices.
NOTE Use an HDMI-certified cables for a reliable audio or video connection.

Communications Connections

Ethernet Ports

The 10/100/1000 Mbps Ethernet ports use RJ45 connectors.

Pin 10/100 Mbps

1

ETx+

2

ETx-

3

ERx+

4

­

5

­

6

ERx-

7

­

8

­

1000 Mbps TRD(0)+ TRD(0)TRD(1)+ TRD(2)+ TRD(2)TRD(1)TRD(3)+ TRD(3)-

NOTE For reliable Ethernet connections, we recommend enabling the ports in standard temperatures and keeping them enabled in high/low temperature environment.

Serial Ports

The serial ports use DB9 connectors. Each port can be configured by software as a RS-232, RS-422, or RS-485 port. The pin assignments for the ports are shown below:

Pin RS-232

1

DCD

2

RxD

3

TxD

4

DTR

5

GND

6

DSR

7

RTS

8

CTS

RS-422
TxDA(-) TxDB(+) RxDB(+) RxDA(-)
GND ­ ­ ­

RS-485 (4-wire) TxDA(-) TxDB(+) RxDB(+) RxDA(-)
GND ­ ­ ­

RS-485 (2-wire)
­ ­ DataB(+) DataA(-) GND ­ ­ ­

– 14 –

USB Hosts
The DRP Series has 3 USB 3.0 Type-A connectors located on the front panel. The ports support keyboard and mouse devices and can also be used to connect a flash disk for storing large amounts of data.
Inserting SD/CFast Card
The DRP computer comes with two slots that allow users to insert one SD card and one CFast card. To install the cards, do the following: 1. Unfasten the two screws on the slot cover.
2. Remove the cover and find the location of the SD and CFast card slots.
3. Insert the SD and CFast cards in the designated slots. Refer to the image printed beside the slots for the correct direction to insert the cards. When the cards are successfully inserted, you will hear a click.
4. To remove the cards, simply push them in to release them and take them out.
Replacing the Battery
The DRP computer comes with one slot for a battery on the bottom panel of the computer. A lithium battery (3 V / 200 mAh) is preinstalled in the slot. To replace the battery, do the following:
1. Unfasten the two screws on the battery cover.
2. Take off the cover. The battery is attached to the slot cover as indicated in the image.
– 15 –

3. Unplug the connector of the battery-cover assembly from the internal wire of the slot.
4. Remove the two screws on the metal plate attached to the battery holder.
5. Place a new battery in the battery holder, replace the metal plate, and fasten the two screws on to the frame to secure the battery.
6. Plug in the connector of the battery-cover assembly to the internal wire of the slot.
7. Place the battery holder back in the slot and secure it by fastening the two screws on the cover.
Warning
· Be sure to use the correct type of battery. Incorrect battery may cause system damage. Contact Moxa’s technical support staff for assistance, if necessary.
· To reduce the risk of fire or burns, do not disassemble, crush, or puncture the battery; do not dispose of in fire or water and do not short external contacts.

– 16 –

BSMI Certification for Taiwan

Declaration of the Presence Condition of the Restricted Substances Marking

: : DRP-C100-C7-T/DRP-C100-C7-8L-T/

Equipment name

DRP-A100-E4-T/DRP-A100-E4-8L-T Type designation (Type)

Restricted substances and its chemical symbols

Unit

Lead (Pb)

Mercury (Hg)

Cadmium

Hexavalent chromium

Polybrominat ed biphenyls

Polybrominated diphenyl ethers

(Cd)

(Cr+6)

(PBB)

(PBDE)

//

1. ” 0.1 wt %” ” 0.01 wt %”
Note 1: “Exceeding 0.1 wt %” and “exceeding 0.01 wt %” indicate that the
percentage content of the restricted substance exceeds the reference percentage value of presence condition.

– 17 –

2. “”
Note 2: “” indicates that the percentage content of the restricted substance does not exceed the percentage of reference value of presence.

3. “”

Note 3: The “-” indicates that the restricted substance corresponds to the exemption.

Moxa +886-3-2737575 1111
DRP-C100-T DRP-C100-L-T DRP-C100-C-T DRP-C100-C1-T DRP-C100-C1-T-Win10 DRP-C100-C5-T DRP-C100-C5-T-Win10 DRP-C100-C7-T DRP-C100-C7-T-Win10 DRP-C100-C1-8L-T DRP-C100-C5-8L-T DRP-C100-C7-8L-T DRP-C100-C1-6C-T DRP-C100-C5-6C-T DRP-C100-C7-6C-T

DRP-C100-C1-2L4C-T DRP-C100-C5-2L4C-T DRP-C100-C7-2L4C-T DRP-A100-T DRP-A100-L-T DRP-A100-C-T DRP-A100-E2-T DRP-A100-E2-T-Win10 DRP-A100-E4-T DRP-A100-E4-T-Win10 DRP-A100-E2-8L-T DRP-A100-E4-8L-T DRP-A100-E2-6C-T DRP-A100-E4-6C-T DRP-A100-E2-2L4C-T DRP-A100-E4-2L4C-T

– 18 –

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals