Overview
The MGate 5101-PBM-MN is an industrial Ethernet gateway for PROFIBUS-to- Modbus-TCP network communication.
Package Checklist
Before installing the MGate 5101-PBM-MN, verify that the package contains the following items
- 1 MGate 5101-PBM-MN gateway
- Quick installation guide (printed)
- Warranty Card
Please notify your sales representative if any of the above items are missing or damaged
Optional Accessories (can be purchased separately
- CBL-F9M9-150: DB9-female-to-DB9-male serial cable, 150 cm
- CBL-F9M9-20: DB9-female-to-DB9-male serial cable, 20 cm
- Mini DB9F-to-TB: DB9-female-to-terminal-block connector
- WK-36-01: Wall-mounting kit
Hardware Introduction
LED Indicators
LED | Color | Function |
---|---|---|
PWR1 | Green | Power is on |
Off | Power is off | |
PWR2 | Green | Power is on |
Off | Power is off |
Ready
| ****
Green
| Steady on: Power is on and the MGate is functioning normally
Blinking: The MGate has been located by the
MGate Manager’s Location function
Red
| Steady on: Power is on and the MGate is booting up
Blinking: Indicates an IP conflict, or the DHCP or
BOOTP server is not responding properly
Off| Power is off or fault condition exists
COMM
| Off| No data exchange
Green| Data exchange with all slaves
Green,
flashing
| Data exchange with at least one slave (not all
configured slaves can communicate with gateway)
Red| Bus control error
CFG| Off| No PROFIBUS configuration
Green| PROFIBUS configuration OK
PBM
| Off| PROFIBUS master is offline
Red| PROFIBUS master is in STOP mode
Green,
flashing
| PROFIBUS master is in CLEAR mode
Green| PROFIBUS master is in OPERATE mode
TOK| Green| Gateway holds the PROFIBUS token
Off| Gateway is waiting for the PROFIBUS token
LED| Color| Function
---|---|---
Ethernet
| Amber| Steady: 10Mbps, no data is transmitting
Blinking: 10Mbps, data is transmitting
Green| Steady: 100Mbps, no data is transmitting
Blinking: 100Mbps, data is transmitting
Off| Ethernet cable is disconnected
Reset Button
The reset button is used to load factory defaults. Use a pointed object such as a straightened paper clip to hold the reset button down for five seconds. Release the reset button when the Ready LED stops blinking
Hardware Installation Procedure
STEP 1: Connect the power adapter. Connect the 12-48 VDC power line or
DIN-rail power supply with the MGate 5101-PBM-MN device’s terminal block. Make
sure the adapter is connected to an earthed socket.
STEP 2: Use a PROFIBUS cable to connect the unit to a PROFIBUS slave
device.
STEP 3: Connect the unit to the Modbus TCP device.
STEP 4: The MGate 5101-PBM-MN series is designed to be attached to a DIN
rail or mounted on a wall. For DIN-rail mounting, push down the spring and
properly attach it to the DIN-rail until it “snaps” into place. For wall
mounting, install the wall-mount kit (optional) first and then screw the
device onto the wall
Wall or Cabinet Mounting
Two metal plates are provided for mounting the unit on a wall or inside a
cabinet. Attach the plates to the unit’s rear panel with screws. With the
plates attached, use screws to mount the unit on a wall. The heads of the
screws should be 5 to 7 mm in diameter, the shafts should be 3 to 4 mm in
diameter, and the length of the screws should be more than 10.5 mm.
For each screw, the head should be 6 mm or less in diameter, and the shaft
should be 3.5 mm or less in diameter.
The following figure illustrates the two mounting options
Software Installation Information
To install MGate Manager, please download it from Moxa’s website at http://www.moxa.com. For more detailed information about MGate Manager, click the Documents button and select the MGate 5101-PBM-MN User’s Manual.
The MGate 5101 also supports login via a web browser
- Default IP address: 192.168.127.254
- Default account: admin
- Default password: moxa
Pin Assignments
PROFIBUS Serial Port (Female DB9)
PIN | Signal Name |
---|---|
1 | – |
2 | – |
3 | PROFIBUS D+ |
4 | RTS |
5 | Signal common |
6 | 5V |
7 | – |
8 | PROFIBUS D- |
9 | – |
Power Input and Relay Output Pinouts
Specifications
Power Input | 12 to 48 VDC |
---|
Power Consumption
(Input Rating)
| 12 to 48 VDC, 360 mA (max.)
Operating Temperature| Standard Models: 0 to 60°C (32 to 140°F) Wide Temp.
Models: -40 to 75°C (-40 to
167°F)
Storage Temperature| -40 to 85°C (-40 to 185°F)
ATEX and IECEx Information
- ATE X Certificate number: DEMKO 14 ATEX 1288
- IECEx number: IECEx UL 14.0023X
- Certificate string: Ex nA IIC T4 Gc
- Ambient range: 0°C ≤ Tamb ≤ 60°C (for suffix without –T)
- Ambient range: -40°C ≤ Tamb ≤ 75°C (for suffix without –T)
- Standards covered:
- EN 60079-0: 2012+A11:2013/IEC 60079-0: Ed 6.0
- EN 60079-15:2010/IEC 60079-15: Ed 4.0
- Field-wiring connection: The device uses a terminal block, solder on the power distribution board, suitable for 12-24 AWG wire size, torque value 4.5 lb-in (0.51 N-m).
- Battery information: Battery is not user-replaceable.
- Installation instructions:
- A 4 mm2 conductor must be used when the connection to the external grounding screw is utilized.
- Conductors suitable for use at an ambient temperature of 84°C must be used for the power supply terminal.
- Special conditions for safe use:
- The device is to be installed in an IECEx/ATEX Certified IP54 enclosure and accessible only through the use of a tool.
- The device is for use in an area of not more than pollution degree 2 in accordance with IEC 60664-1.
ATTENTION
- For installations in hazardous locations (Class 1, Division 2): These devices are to be installed in an enclosure with a tool-removable cover or door, suitable for the environment
- For installations in hazardous locations (Class 1, Division 2): These devices are to be installed in an enclosure with a tool-removable cover or door, suitable for the environment
- Do not disconnect equipment unless the power has been switched off, or the area is known to be nonhazardous.
- Substitution of any components may impair suitability for Class 1, Division 2.
- EXPOSURE TO SOME CHEMICALS MAY DEGRADE THE SEALING PROPERTIES OF MATERIALS USED IN THE FOLLOWING DEVICE: Sealed Relay Device U21
Moxa Inc. No. 1111, Heping Rd., Bade Dist., Taoyuan City 334004, Taiwan
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>