Qlima H 408 Humidifier – 5600 ml – 313 ml – h Instruction Manual
- June 6, 2024
- Qlima
Table of Contents
H 408
**OPERATING MANUAL
**
Dear Sir, Madam,
Congratulations on the purchase of your humidifier. You have acquired a high-
quality product that will give you many years of pleasure if you use it
responsibly. Please read the user’s manual first in order to ensure the
optimum life span of your humidifier. On behalf of the manufacturer, we
provide a two-year warranty on the material- or manufacturing defects.
Enjoy your humidifier.
Yours sincerely,
PVG Holding B.V.
Customer Service Department
- PLEASE READ THE USER’S MANUAL FIRST.
- IF YOU HAVE ANY DOUBTS, CONSULT YOUR DEALER.
IMPORTANT COMPONENTS
- Mist nozzle
- Aroma box
- Water tank
- Water softening filter (not included)
- Ultrasonic Transducer
- Ash damper
- Control knob
- Night light switch
SAFETY
- Read this user manual carefully before you use the appliance and keep it for future refer
- The installation must be completely in accordance with local regulations, ordinances and
- This product is only suitable for use as a humidifier in normal indoor household operations.
- The appliance is suitable for mains voltages ranging from 220-240V – 50/60Hz.
- The capacity of the humidifier depends on the temperature and the humidity in the room.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
- The electricity supply to the device must be checked by a recognized professional if you have any doubts regarding the compatibility.
- Always take the plug out of the socket when the device is not in use.
- Do not insert objects into the openings of the
- Keep the spraying. mouth from directly facing fur-nature or electronic equipment to avoid damage.
- Never turn it on when waterless.
- Never move the appliance when there’s water
- Never submerge the product in water or other
- Due to the emission of steam care should be taken when using the appliance.
- Tap water can only be used when the hardness of the water is between 40 and 75 mg of Calcium Carbonate per liter. Water with a higher level of Calcium Caronate will likely cause scaling inside the product and/or on surfaces or items surrounding the product (f.e. furniture). Hard water can cause the product to be damaged and to break. This is not covered by the warranty.
- Use a de-scaling fluid to remove scaling.
- To prevent legionella infections, it is necessary to replace the water in the water tank at least once a week.
- Never turn on the unit, when the water in the water tank is in there for over a week.
- Do not add other fluids to the (demineralised) water to the water container. Fluids like aroma oils could cause damage to the product.
- This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved.
- Children shall not play with the appliance.
- Cleaning and user maintenance shall not be made by children without supervision.
- Unplug the appliance during filling and cleaning.
- The appliance should always be placed on a firm, flat, waterproof surface at least 1.2 m away from the bedside and 30 cm from the wall.
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons in order to avoid a hazard.
- WARNING: Micro-organisms that may be present in the water or in the environment where the appliance is used or stored, can grow in the water reservoir and be blown in the air causing very serious health risks when the water is not renewed and the tank is not cleaned properly every 3 days.
INSTALLATION
- Do not place this machine near the human body to avoid the discomfort to human body;
- Do not place this machine near wooden furniture to prevent furniture become damp and damaged;
- Do not permit the area around the humidifier to become damp or wet. If dampness occurs, turn the output of the humidifier down. If the humidifier output volume cannot be turned down, use the humidifier intermittently. Do not allow absorbent materials, such as carpeting, curtains, drapes, or tablecloths, to become damp.
- Be aware that high humidity levels may encourage the growth of biological organisms in the environment.
- Place this machine evenly and keep a distance from the wall at least 30 cm to keep it running normally;
ATTENTION
Before use please check the ultrasonic transducer first. When the ultrasonic
transducer is damaged, do not use this machine.
-
Be sure the humidifier is switched off (knob turned all the way to the left). Remove the tank from the main housing. Bring the tank to the sink, turn it upside down, and twist off the tank cap by turning counterclockwise. Fill the tank with cool, fresh tap water. DO NOT fill with warm water as this may cause leaking. Replace the cap on tank IRMLY. Place tank back onto the base. The tank will immediately begin to empty into the base.
-
Connect this machine with a 220-240V power socket, then it enters standby status.
To turn the unit on, turn the Volume Control knob clockwise, and the LED indicator would turn to green color. Turning the knob all the way to the right will produce the
highest moisture. Turning to the left will produce lower moisture with a longer run time. -
When the humidifier runs out of water, the LED indicator will turn red, and the transducer and fan will automatically shut off. Once the tank is empty, turn the Power Off and unplug the unit.
-
There is an aroma box in the mist nozzle, you can open the nozzle and put a few drops of essential oil in the sponge, then fix the nozzle. When the humidifier is turned on, the aroma would come out together with the mist.
OPERATION
- Turn the power knob clockwise, the power indicator is on in green color; Turn the knob counterclockwise to OFF position, the indicator light is OFF;
- To turn the unit on, turn the Volume Control knob clockwise. Turning the knob all the way to the right will produce the highest moisture. Turning to the left will produce lower moisture with a longer run time.
- Press the night light button would turn on the night light, and press it again to turn off the night light.
- When the water level is low, the water shortage indicator would turn to red color and the humidifier would turn off automatically, please refill the water tank.
WARNINGS
- Never fill the water reservoir with water hotter than 30°C.
- Never fill the reservoir through the mist nozzle.
- Ensure that the filler cap of the reservoir is not leaking. Close the filler cap tightly.
- Ensure that the device and the reservoir are always clean. Remove any dirt before using the device.
- Do not position the outlet of the cold mist nozzle too close to the equipment, furniture, etc. to avoid water damage.
- Check the actual air humidity regularly in the room to prevent any damage to furniture, equipment, etc. from too high humidity.
MAINTENANCE
WARNING
Before cleaning and maintaining this machine, do turn it off and pull out the
plug.
Make sure the machine is powered off to avoid electric shock;
A. CLEAN OSCILLATING PLATE
- Take out the water tank of the humidifier.
- Pour out residual water in the water sink
- Use a clean brush to clean the oscillating plate. Do not use household cleaners to clean oscillating plates which will affect their lifetime. Do not suggest exposing the humidifier under candle/ lampblack, fireplace ash, and smoke.
ATTENTION
Do wear gloves when cleaning oscillating plates to avoid hand scald by hot
water in the water sink.
B. CLEAN OUTER APPEARANCE OF HUMIDIFIER
- Power off and pull out the plug
- Dip a little soap water on a towel to clean the outer appearance of the humidifier
- Do not make water flow inside of the machine. It may cause damage to your machine and electric shock.
- After cleaning, place this machine in ventilating place to make it dry (do not expose it to the sun). Only when the machine is completely dry can you use it.
C. CLEAN WATER TANK
Empty the tank and refill every third day. Before refilling, clean it with
fresh tap water or cleaning agents if required by the manufacturer. Remove any
scale, deposits, or film that has formed on the sides of the tank or on
interior surfaces, and wipe all surfaces dry.
ATTENTION
- Never leave water in the reservoir when the appliance is not in use.
- Empty and clean the humidifier before storage.
- Clean the humidifier before the next use.
FAULTS
Common problems
| Failure analysis|
Solutions
---|---|---
The machine doesn’t work|
- The power switch is not on
- Forget to plug the power
- Water shortage
- The floating ball has a failure
|
- Open switch button
- Check whether power is connected
- Fill water
- Check if floating ball is assembled in the proper place
Bad mist effect|
- The mist outlet is blocked
- The water level in the water sink is too high
|
- Check and make sure the mist outlet is not blocked
- Empty the water tank and the basin and refill the tank with cool tap water
TECHNICAL SPECIFICATIONS
Model | H 408 |
---|---|
Mains | 220-240~50/60Hz |
Electrical consumption | 23 W |
Capacity water container | 5.6 l |
Maximum evaporation capacity | 7.5 l/day |
Dimensions mm (w x d x h ) | 259x182x328 |
Net weight | 2.30 KG |
CONDITIONS OF WARRANTY
There is a two-year warranty on your humidifier from the date of purchase. All
material or
manufacturing defects will be repaired free of charge. The following applies:
- All claims for compensation, including consequential damage, will not be entertained.
- Any repairs or replacement of components during the warranty period will not result in an extension of the warranty period.
- The warranty will expire if any alterations have been made, no genuine components have been fitted or if the humidifier has been repaired by a third party.
- Components subject to normal wear and tear, such as the air filter, are not covered by the warranty.
- The warranty is only valid on the presentation of the original, unaltered, and date-stamped purchase receipt.
- The warranty does not cover damage caused by actions that deviate from those as described in the user’s manual or by neglect.
- Transportation costs and the risks involved during the transportation of the humidifier or components shall always be for the account of the purchaser.
To prevent unnecessary expenses, we recommend that you always carefully read
the user’s manual first. If this does not provide a solution, take the
humidifier to your distributor for repair.
Do not dispose of electrical appliances as unsorted municipal waste, use
separate collection facilities. Contact your local government for information
regarding the collection systems available. If electrical appliances are
disposed of in landfills or dumps, hazardous substances can leak into the
groundwater and get into the food chain, damaging your health and well-being.
When replacing old appliances with new ones, the retailer is legally obligated
to take back your old appliance for disposal at least free of charge.
INTERNET
In order to better be able to be of service to you the most recent version of the user, installation, and/or service guide can be downloaded from www.qlima.com.
www.Qlima.com
Distributed in Europe by PVG Holding B.V.
If you need information or if you have a problem, please visit our website
(www.qlima.com) or contact our sales support ( T:
+31 412 694
694).PVG Holding BV
Kanaalstraat 12 C – 5347 KM Oss
the Netherlands
P.O. Box 96 – 5340 AB Oss
the Netherlands
MarCom
mvz©220118
man_H408 (’22) V1
References
- Qlima homepage
- Welcome to Comfortable Living: Explore Qlima's Home Page for Innovative Heating and Cooling Solutions
- Home page Qlima.es
- Page d'accueil Qlima
- Qlima, esperti del comfort domestico
- Qlima homepage
- Qlima
Read User Manual Online (PDF format)