RENOGY RBT2425LFP-G1 Lithium Iron Phosphate Battery User Guide
- June 4, 2024
- Renogy
Table of Contents
RENOGY RBT2425LFP-G1 Lithium Iron Phosphate Battery User Guide
Safety Precautions
- Please use circuit breakers, fuses, or disconnects that are appropriately sized by certified electricians, licensed installers, or regional code authorities to protect all the electrical equipment in your system. The battery contains a battery management system (BMS) that protects the battery cells from over-charge, over-discharge, and over-current, however this alone will not protect your system from severe electrical conditions.
- Please verify the polarity before connecting wiring. Reverse polarity can and will destroy the battery.
- DO NOT short-circuit the battery terminals. Doing so can cause bursts in amperage and lead to irreversible damage to the system and the battery (and possibly cause an explosion).
- Please wear proper personal protective equipment when working on the battery.
- DO NOT string batteries in series. Doing so can cause catastrophic failure.
- Please ONLY connect identical batteries in parallel to ensure the best battery performance.
- If the battery shuts off due to low state of charge, please disconnect the battery from your equipment to eliminate parasitic loads and charge the battery as soon as possible.
- It is highly recommended to pair the battery with low voltage disconnect devices in the system setup.
Battery Installation
Safe and reliable installation requires trained and certified technicians. This section can only serve as a guideline as all scenarios cannot be covered.
-
Wear protective clothing and eyeglasses
-
Size the battery cables appropriately
Use high stranded copper and heavy gauge cables to handle possible loads from the battery. Make sure to maintain identical cable lengths. -
Verify correctpolarity
Reverse polarity can and will destroy the battery. Use a multimeter to determine proper polarity. -
Tighten the cable connections
Over-tightening cable connections can cause terminal breakage and loose cable connections can cause terminal meltdown or fire. -
Place the battery in a well-ventilated area
Battery Operation
-
Depending on shipping times and the time since manufacture, the battery may be received at a partial state of charge. Please fully charge the battery prior to the first use.
-
Standard charging consists of charging at 0.2C constant current until the battery reaches 29.0V. The battery is then charged at
a constant voltage of 29V while tapering the charging current. Charging is considered complete when the charging current has
tapered to 0.05C. Safe charging requires temperatures between 0°C and 55°C (32°F and 131°F ) and takes approximately 5.5
hours. -
For standard discharging, the battery is discharged at 0.2C constant current until the battery reaches 20V. Safe discharging
requires temperatures between-20 and 60°C (-4 and 140°F).
Battery Storage
- Please charge the battery to 30%~50% and store the battery in an open, well-ventilated, dry, clean area with temperatures of around 23ºC (73.4ºF ).
- Long periods of storage can deteriorate the battery performance. It is recommended to charge the battery at least once every three months to prevent over-discharge.
Battery Management System (BMS)
The BMS will protect and shut the battery down when it is over-discharged or short circuited. In these rare cases, the battery will show 0V voltage. Please activate the battery using an external charging source that has lithium battery activation function. Please contact our Tech Support team at (909)287-7111 for more information about the BMS.
Battery Specifications
Protection Circuit Module (PCM) Specifications
Renogy | www.renogy.com | techsupport@renogy.com | T: 909-287-7111 | F: 888-543-1164
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>