BEOK HY316 Black Round Wifi Digital Heating Thermostat User Manual
- June 5, 2024
- BEOK
Table of Contents
BEOK HY316 Black Round Wifi Digital Heating Thermostat User Manual
Product Specifications
- Power: 90-240Vac 50/60HZ
- Display accuracy::0.5°C
- Probe sensor::NTC(10k)1%
- Contact capacity::3A/250V(WW);16A/250V(WE)
- Working environment temperature::0~90°C
- Range of temperature adjustment::5~35°C
- Range of temperature display::0~70°C
- Insulating condition: Normal environment
- Running program: Set per 1 week as a cycle
- Output: Switch relay
- Installation: Wall mounted or on battery seat
- Size(mm):868630
Before wiring and installing
- Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition.
- Check the ratings given in the instructions and on the product to make sure the produce is suitable for your application.
- Installer must be a trained experienced service technician.
- After installation is complete.check out produce operation as provided in these instructions
CAUTION
Electrical shock or equipment Damage Hazard. or short equipment circuitry.
Disconnect power supply before installation
Wiring Diagram
Water heating and gas wall-hung boiler heating, no contact wiring diagram,(disconnection when electric valve close)
Note: 3 & 4 connect with power, 5 & 6 connect with gas boiler,1& 2 connect with thermal actuator, please do not connect 1&2 to gas boiler,If you connect it wrongly, there will be Short circuit,our gas boiler board will be damaged.
Displays
Description of icon
Operation key
Programmable
5+2 (factory default),6+1 and 7 models 6 times period setting for user choose. In the advanced options choose model of you need, under power on state, long press for 3-5 seconds enter into programming mode setting, then short press choose: hour,minute, time period, and press and to adjust data, finished setting, about 10 seconds will automatic save and exist.
The optimum comfort temperature is 18℃-22℃.
Advanced options
A Advanced options
Under turn off state, long press for 3-5 seconds to access advanced setting. From A1 to AE, short press to choose the option, and adjust data by short press to switch next option.Remain about 10 seconds after finish setting will quit setting.
NO | Setting Options | Data Setting Function | Factory Default |
---|
A1
| Measure Temperature Calibration| -9-+9℃| 0.5℃
Accuracy
Calibration
A2| Temperature control return difference setting| 0.5-2.5℃| 1℃
A3| Children lock setting| 0:half lock 1:full lock| 0:half
lock
A4| Power with memory function| 0:Power with memory function 1:Shutdown
power after power off
2:Shutdown power after power on| 0
A5| Backlight Sleep time| time 5-30 Sec| 10 Sec
A6| Weekly programming selection| 0: 5+2
1: 6+1
2: 7
| 0
A7| Setting temperature lowest limit| 1-10℃| 5℃
A8| Setting temperature highest Limit| 20-70℃| 35℃
A9| Limit value of low temperature for external
sensor(anti-freeze protection)| 1. 1-10℃
2. Exceed 10℃, screen display【–】 , Low temperature protection was
cancelled.| 5℃
AA| Limit value of high temperature for external sensor| 1. 35℃-70℃
2. Under 35℃, screen display【–】 , high temperature protection was
cancelled| 45℃
AB| External sensors limit temperature control| 1-9℃| 2℃
| return difference| |
---|---|---|---
AC| Window ventilation function setting| Press ,display 10℃,when temperature
10℃ turn on window ventilation function, stop heating mode, press
display — , turn off Window ventilation
| Disabled —
AD| Window ventilation running time| 10-20 mins| 10mins
AE| Restore factory defaults| ,Display Ao ,long press key until whole
show|
B Advanced options
Under turn off state, long press for 3-5 seconds to access advanced setting. From BN to BO, short press to choose the option, and adjust data by short press to switch next option.Remain about 10 seconds after finish setting will quit setting.
NO | Setting Options | Data Setting Function | Factory Default |
---|---|---|---|
BN | Options of sensor control | N1:Built-in sensor (high temperature protection |
close) N2:External sensor (high temperature protection close)
N3:Built-in sensor control temperature ,external sensor limit temperature
(external sensor detect the temperature is higher than highest temperature of
external sensor, thermostat will disconnect relay,turnoff load)| N1
BC| Descaling function| 0:Close descaling function 1:Open descaling function (
valve is continuously closed over 100 hours,it will be opened for 3 minutes
automatically)| 0
BO| Procedure parameters| unchangeable| 10
Return difference: limit valve of external sensor is 45℃ for factory default (A6),value of external sensor control return difference (A3) is 2. when temperature rise to 45℃,then relay stop working and will remind high temperature production alarm. If temperature decline to 43℃relay continue to work and heating alarm will be relieved. (it can be operated ,only when indoor temperature is lower than setting temperature )
Sensor fault display: please choose correct working way of built-in and
external sensor, if choose wrongly or sensor fault (breakdown), “E1” or “E2”
will be displayed on the screen. Thermostat will stop heating until the fault
is eliminated Warranty:
We offer the warranty of 24 months, from the sales day. The products of our
company can have life time warranty ,if it is not the quality problems, or
beyond the warranty period, we will charge for the after-sale service.
WIFI APP Download And Sign Up And Pair Thermostat
Preparation required for Wifi Connection:
A 4G mobile phone and wireless router, reconnect the wireless router on the
mobile phone WLAN interface, and record the WIFI password [need to be used
when the thermostat is paired with the Wifi.
Note: Wifi from router must be 2.4G, 4G wifi from the other mobile phone
hotspot is also ok, 5G router wifi is not ok.
Step 1 Download your APP
Scan following QR cod and download APP through browser(Android also can search “ Smart life” at Google Play, IPhone also can search “Smart life” at App Store
Step 2 Register your account
- After install APP,click “register” (Fig 2-1)
- Please read the Privacy Policy and press Agree to proceed to the next step. (Fig 2-2)
- Registration account name uses your available Email Or mobile phone number, and please select Region, then click “Continue”(Fig 2-3)
- You will receive a 6-digit verification code from your email or SMS and enter your phone (Fig 2-4)
- Please set the account password, Password must contain 6-20 letters and numbers. click “Done”(Fig 2-5)
Step 3 Create family information(Fig 3-1)
- Fill in the family name(Fig 3-2 ).
- 2. Select or add a room(Fig 3-2).
- 3. Set location (Fig 3-4)
Step 4 Connect your Wi-Fi signal ( EZ distribution mode)
In the power-on state, long press “ ” for 3-5 seconds, the “OFF” and “ ” will flashing in the same time,short press “ ” to indicate the EZ distribution mode, the icon flashes to indicate the AP distribution mode, the icon indicates that the phone has been disconnected with the device. Press “Add Device” or “+” in the upper right corner to add the device (Fig 4-1) and select the device type”Thermostat”( Fig 4-2)
On your thermostat, Click Confirm icon rapidly blink. then select your network and back to your app to enter the password of your wireless router fig 4-4)and confirm.The app will connect automatically(Fig4-5)This may typically take up to 5~90 seconds to complete. This is Ez mode which provides fast network connection between your app and your device
Your room name could be edited when the device is connected,And you can choose the corresponding room location. For example, bedroom, kitchen, living room, etc
Step 5 AP distribution mode
If your router doesn’t support it or your wifi signal is weak or you can not connect by EZ mode, press the AP Mode on the upper right corner in (Fig 5-1)If you have connected your thermostat successfully, please ignore the app setting as blow On your thermostat Click Confirm icon rapidly blink then select your network and back to your app to enter the password of your wireless router(fig 4-4)and confirm.The app will go into the page in (Fig 5-2)Press Connect now to select the wifi signal Smartlife-XXXX of your thermostat(Fig 5-3)Go back to your app and click Connect now then the app will connect automatically(Fig 4-5) This may typically take up to 5~90 seconds to complete.
Step 6 APP Device interface operation and How to create a group
- Power on/off button
- Mode key: Manual mode, Auto mode, Holiday mode.
- Child lock: After the child lock turned on, the APP cannot be operated.
- Set key: After clicking on, you can select the programmed mode (5+2, 61, 7 days) and set the temperature and time for the six periods of the weekday and weekend. 5. Basic information page(Fig 6-1、Fig6-2)Device name: The device name can be modified according to your demand. Device location: Share device: Share the device to the mobile phone or email account of the registered family member Create Group: Add all the devices which need to operate at the same time to the created group for convenient operation. Device information;Contains virtual ID;IP address;Mac address;Device timezone Remove device: After deleting the device, you need to reconnect the network if you want to use it. Third-party controls supported: amazon alexa/google assistant/IFTTT, click to enter, you will seethe steps
Step 7 Family management(Fig6-3)
Add family: Family naming; family location setting; select room name, you can also add room name,upon completion, it will enter the Home Setting interface.
Step 8
What is your Smart Scene and How to use it? (Fig6-4)
set your home to automatically turn on thermostat on when you back home(fig
).Press +button into the setting
Step 1:You can set a condition for task like Temperature below 21 degree,then
click save,(condition:temp.,Humidity,weather,PM2.5,Air
Quality,Sunrise/Sunset,Device)
Step 2: Add a task. Press + to Select Device (Power,Set Temp,Lock Mode) to
act, then Save.If you want to delete the scene,you can press Delete in the
end.
NOTE: The room sound could be turned on/off in PROFILE- ETTING- SOUND.
The sound is matched with the default of your system
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>