The 8310-806K(R) allows the operator to be set to one of three modes.
OFF – the operator will not respond to any input signals and open the
door.
AUTO – the operator will respond to input signals and open the door.
HOLD OPEN – the operator will open the door to 90° and remain there until
the selector switch is turned to another position.
Note: The key can be removed in any position (8310-806K only).
To install:
- Use stick-on template (provided) and place at desired position. Drill the (2) .116″ dia. holes and the (1) 1″ dia. hole as shown.
- Route the 6′ wire cable to the operator.
- Plug the switch into the 3-Pin connector on the controller.
- Use the key to put the operator in the desired mode.
NOTE: To use the 8310-806K(R) on the 4600 and 9100 Series operators, cut
the plug off, strip the wires about .25 inches, and attach to terminals, as
shown below.