761217 Wall Mounted Filtered Water
Cooler
User Manual
System 761217 certified by IAPMO R&T against NSF/ ANSI/CAN 372 for lead free compliance
Read this manual thoroughly prior to installation, operation or maintenance. Keep these instructions in a safe location for future reference. For questions, visit globalindustrial.com or contact Customer Service at 1-800-645-2982.
WARNING
- Keep compressor in an upright position for 24 hours before water connections and initial power-on. Failure to do so will void the warranty.
- For indoor commercial use only.
- All installation work must be performed by authorized service personnel.
- Two or more people are recommended to lift and install the unit.
- To avoid the risk of property damage and/or personal injury, mount the unit to a flat finished wall surface with adequate support.
- Check local codes for plumbing requirements prior to installation.
- Prior to initial installation, install a shut-off valve (not included) from the water supply.
- Thoroughly flush all water lines and fittings of all foreign matter before connecting to the cooler. Failure to do so will void the warranty.
- Check for any leaks before the initial operation.
- DO NOT attempt to repair or replace any part of your appliance unless it is specifically recommended in this manual. All other services should be referred to a qualified technician.
- For use with clean, clear potable drinking water only.
- Shut off the water supply during installation to reduce the risk of water damage.
- Ensure proper ventilation by allowing appropriate clearance of housing louvers to the wall on each side of the cooler, as specified in the rough-in guide.
- NEVER wire the compressor directly to an electrical supply.
- DO NOT allow children to play with the appliance.
- The Interior of the unit may contain sharp edges. Wear gloves when handling or servicing the unit.
- Failure to follow installation instructions will void warranty.
Note: These fixtures are intended for indoor commercial use only. Do not
expose to freezing temperatures.
The grounding of electrical equipment to water lines is a common procedure.
This grounding may be in the building or occur away from the building. This
grounding
can cause electric feedback into the water cooler creating electrolysis which
creates a metallic taste or causes the water metal content to increase.
Connect to the water supply using non-conductive materials.
Risk of Electrical Shock
- Disconnect power before servicing the unit.
- Electric supply must be identical in voltage, cycle, and phase to those specified in the specifications below. The unit must be plugged into a GFCI outlet.
- Always pull the plug – not the cord – when disconnecting from the outlet
- DO NOT use if the power cord is worn or damaged. Power cords should only be replaced by qualified service technicians using genuine replacement parts.
- Check local codes for electrical requirements.
- DO NOT disassemble or modify the unit.
- Use Global Industrial Filter only-Model 670336
Voltage/Hertz | 115V/60Hz |
---|---|
*Chilling Capacity | 5.3 GPS |
Full-Load Amps | 1.9 Amps |
Rated Watts | 185 W |
Filter Capacity | 4750 or 3600 Gallons |
Quick-Fill Rate | 1.0 GPM |
Water Flow | Laminar |
Overall Dimensions | 181/8″W x 16″D x 195/16″H |
Certification | UL399 and CAN/CSA 22.2 No. 120 ADA |
Compliant
System 761217 certified by IAPMO R&T against NSF/ANSI/CAN 372 for lead-free
compliance
Filter 670336 certified by NSF to NSF/ANSI 42153
- At 46° – 54° (F) against ambient air temperature of 77° (F)
Package Contents:
Box 1 – 761214 Top Assembly for Water Fountain
Box 2 – 761212 Cooling System for Water Fountain
Note:
- Prior to installation, consult with local, state, and federal codes for proper mounting height.
- All installation and service should only be performed by authorized personnel.
- The dimensions are shown below comply with ADA requirements at the time of printing.
- Allow 4″ minimum clearance on both sides to allow for proper ventilation through cabinet louvers.
- Thoroughly flush all water lines and fittings of all foreign matter before connecting to the Cooling System.
Failure to do so will void warranty.
Required Tools:
- Safety Glasses
- Safety Gloves
- Electric Drill
- Phillips Head Screwdriver
- Flathead Screwdriver
- Tape Measure
- Pencil
- Level Device
- (8) 75-lb. Capacity Flat Head Wall Anchors (appropriate for your wall type)
- (8) Flat Head Anchor Screws
WARNING
- Review manual thoroughly and verify rough-ins before installation. Keep these instructions in a safe location for future reference.
- Keep compressor in an upright position for 24 hours before water connections and initial power-on. Failure to do so will void warranty.
- It is recommended to assemble this product on a tabletop or bench.
- The fixture must be mounted to a flat finished industry standard wall surface. The wall surface must have adequate support to secure the fixture, with the addition of wall anchors (not included) is required.
- All receptacles must be wired to a GFCI-protected circuit. The fixture must be earth grounded per National Electric Code (NEC).
- Inspect fixture and all parts for damage.
Assembly Instructions
CONTENTS
Ref.| Qty.| Description
1| 1| Cooling System
2| 1| Lower Cover
3| 1| Mounting Bracket
4| 1| Stainless Steel Pan
5| 1| Filter Access Door
6| 1| Water Fitter
H1| 4| M4 x 8mm Lg. Torx
a Head Anti-Theft Screw
2| 1| Torx Key
H3| 2| ST4.2*12 Phillips tapping screw
H4| 2| M4 x0 .7x 8mm Lg. Phillips Flat Head Screw
H5| 2| Filler Access Door Key
Remove Lower Cover
Using the Anti-Theft Screw Star Key, remove the (4) screws at the bottom of
the Lower Cover. Set Lower Cover aside and save screws for reinstallation.
WARNING
Assembly and installation of equipment should be performed by 2 people.
Remove mounting bracket
Using a Phillips head screwdriver, remove the Mount Bracket from the rear of
the Cooling System by removing (1) screw. Set bracket aside and save screws
for reinstallation
Connect Water Lines
- Connect water line (#1) from the Stainless Steel Pan to the Water Control Valve (#1) in the Cooling System. Push line until locked into place.
WARNING
Use 2 people when completing steps 3A – 3C.
Connect Wire Connectors
- Connect white Activation Connector (A) to Power Supply (A).
- Connect (2) blue Activation Connectors (B) to the Solenoid Valve (B).
Attach stainless steel pan
- Feed the Reset Button Connection through the Cooling System’s frame and carefully lower the Stainless Steel Pan on top of the Cooling System.
- Attach the Stainless Steel Pan to the Cooling System using (2) H3 screws and (2) H4 screws
CAUTION
Avoid crossing wires against sharp edges
WARNING
installation of equipment should be performed by 2 people.
Attach the mounting bracket to the wall
Note: To comply with ADA requirements, the base of the stencil must be
installed 11″ to 14 /4″ from the floor. See Rough-in Guide for additional ADA
requirements.
Note: Before installing the bracket to the wall, check the location of
the power source, water line, and drain.
- Affix stencil with tape to appropriate wall. It is recommended to use a level to ensure the stencil is hung straight horizontally.
- Drill (6) holes appropriate for the wall anchors (75 lb. minimum each) as indicated on the mounting bracket on the stencil. Use appropriate anchors for your wall type.
- Drill (2) holes appropriate for the wall anchors (75 lb. minimum each) as indicated on the bottom support holes on the stencil. Use appropriate anchors for your wall type.
- Remove stencil from the wall and install bracket onto the wall using appropriate anchors.
CAUTION
Hanging assembled unit on the wall
Carefully hang the assembled unit onto the wall by lowering it onto the
mounting bracket.
Valve Control
- Ensure water control valves are turned to the closed position.
- Attach 2 screws (not included) through the frame of the Cooling System and into the bottom support holes previously drilled into the wall.
- Connect the building’s water supply to the Filter Head Connection. This connection must be made through the back of the Cooling System.
- Connect the internal drain line to the building’s external drain. This connection must be made through the back of the Cooling System.
Note: If the cooling system is on its side or back for more than 10 minutes, allow it to stand in the upright position for 24 hours before water connections and initial power-on.
Install water filter
- Remove the receiver protective cover from the water filter.
- Insert filter into the filter head by turning clockwise until locked into place.
- Turn water control valve #1 to the open position.
- Keep water control valve #2 in the closed position
- Check all connections for leaks. If leaks are detected ensure all connections are tight and are fully inserted.
Check local codes for plumbing requirements prior to installation.
-
Turn on buildings’ water supply and check all connections for leaks.
-
Fix any leaks before continuing.
-
Plug the power cord into the outlet.
-
Remove the filter access door using the provided key.
Reattach lower cover
- Reattach the Lower Cover to the Cooling System using (6) H1 anti-theft screws.
WARNING
Risk Of Electrical Shock
- Turn off power prior to performing any maintenance.
- Verify supply voltage accuracy.
- Ensure all electrical and grounded connections are in accordance with the National Electrical Code and any other applicable local code requirements.
- All wiring connections should be capped with approved wire connectors. The warnings, precautions, and instructions discussed cannot cover all possible conditions and situations that may occur. Failure to heed these warnings may result in property damage and personal injury.
General Safety Information
- To reduce the risk of property damage, personal injury, electric shock, falling equipment, and other hazards please read all instructions and warnings.
- Installation, service, and maintenance should be
- All parties must follow proper safety procedures and precautions at all times.
- Do Not Install Damaged Products!
CAUTION
Make sure all wires are tucked in before attaching the cover plate to the
lower cover.
Connect the reset cable to the activation button
- Connect the Reset Button connection cable to the Activation Buttons located at the top of the filter access door frame.
- Reinstall the filter access door using the provided key.
- Unit is now ready for use.
Operation
Note: Initial water flow may have sputter due to air in the water lines;
this will be eliminated once the air is purged from all water lines.
To operate the drinking fountain, push front or side activation buttons on the
stainless steel pan to dispense cooled filtered water from the bubbler.
Adjusting Settings
Water Flow Pressure: Adjust the water flow pressure as needed by turning the
water control valve. Turn clockwise to decrease the water pressure, or
counterclockwise to increase the water pressure.
Note: When adjusting, aim water flow to the center of the stainless steel
pan.
Note: Initial dispenses may have air in line which may cause a sputter.
Allow a few seconds for the air to be purged from the waterline.
Water Temperature: The machine comes with a preset water temperature of around
45°F. If a different temperature is required, remove Lower Cover and access
the thermostat on the front housing frame. Using a flathead screwdriver, turn
the thermostat screw clockwise to a lower temperature setting.
Note: Please allow 5-10 minutes for the water temperature to change.
Installing/Replacing Filter
- Remove the filter access door on the lower cover using the provided key (H4).
- Grasp the old filter and turn counterclockwise to remove it from the filter head.
- Insert new filter onto filter head by turning the filter clockwise until locked into place.
- Reinstall and lock the filter access door.
Replacement Filters: Model 670336
For more information visit: globalindustrial.com or call 1-800-645-2982.
Filter Status Lights
When the filter level is at 100%| 5 LED bars will be displayed
When the filter level is at 80%| 4 LED bars will be displayed
When the filter level is at 60%| 3 LED bars will be displayed
When the filter level is at 40%| 2 LED bars will be displayed
When the filter level is at 20%| 1 LED bar will be displayed
When the filter level is at 10%| 1 LED bar will be displayed and will FLASH
When the filter level is at 0%| 5 LED bars will be displayed and will FLASH
Programming Settings
Accessing the Programming Buttons:
To access the programming buttons, open the filter access door on the lower
cover using the provided key (H4). The two program buttons are located on the
top of the filter access door frame.
Resetting Filter Status
Note: This step is not required for initial use
- Press and hold the ENTER button for 5 seconds, until all 5 LED lights flash.
- Tap the SET button; all 5 LED lights will be displayed.
- Press and hold the ENTER button for 5 seconds to reset the filter status.
Select Filter Size
-
Press and hold ENTER button for 5 seconds, until all 5 LED lights flash.
-
Tap the SET button to access Filter Size mode:
• Tap the SET button 1 time to select the 3600-gallon filter option. 4 LED lights will be displayed.
• Tap the SET button 2 times to select the 3000-gallon filter option. 3 LED lights will be displayed.
• Tap the SET button 3 times to select the 1500 gallon filter option. 2 LED lights will be displayed.
• Tap the SET button 4 times to select the NO filter option. 1 LED light will be displayed. -
Tap ENTER button to confirm filter size.
Note:
- The system will timeout and revert to the previous setting if no selection is made within 2 minutes.
- If the “NO” filter option is selected, zero LED status bars will be displayed in the standard view.
- Filter size does not need to be reselected if replacing a filter with the same capacity as the previously used filter.
Maintenance
WARNING
ALWAYS disconnect power and shut off the main water supplier prior to
maintenance. Observe the entire unit for possible water leakage.
- Inspect the Cooling System every 6 months for leakage, proper operation, and performance.
- When cleaning, do not use harsh chemicals, or abrasive or petroleum-based cleaners. Doing so will void warranty.
- Exterior parts can be cleaned using a soft cloth with mild detergents or soapy water. Do not use steel soap pads. Rinse and towel dry.
- Extra caution should be used to clean mirror-finished stainless steel panels, as they can be easily scratched.
- Periodically clean cabinet ventilation louvers and condenser fins with a vacuum cleaner, or air hose to avoid excess dirt.
- Periodically remove the Lower Cover of the Cooling System and clean out the water drain.
Note: Wiping the surface clean to remove debris or build-up will not hurt the antimicrobial properties.
Troubleshooting
Issue | Possible Cause | Suggested Action |
---|---|---|
Water Temperature not Cool | The thermostat is set too high | Lower the water |
temperature on the thermostat
(see Adjusting Settings, page 8).
No power to the unit|
- Check power cord
- Check the electrical receptacle for power and correct voltage; the electric supply must be identical in voltage, cycle, and phase to that specified on the nameplate
- Check for loose wires within the Cooling System
- Check to see if the GFCI outlet tripped
Restricted or No Water
Flow| Water control valve(s) are closed| Access the water control valve and
turn it on. Adjust water
flow pressure as needed (see Adjusting Settings, pg 10)
Blockage in the water line| Check water supply lines and flush out any
blockage
The filter is blocked| Change fitter
Noisy Operation| Condenser fan blades not turning freely| Clear fan blades
free from any restrictions
Hardware rattling| Ensure hardware is tightened