CHAUVET PROFESSIONAL 62643 Maverick Force S Profile Party Light User Guide
- June 5, 2024
- Chauvet Professional
Table of Contents
Maverick Force
S Profile
Quick Reference Guide
Model ID : MAVERICKFORCESPROFILE
About This Guide
The Maverick Force s Profile Quick Reference Guide (QRG) has basic product
information such as connection, mounting, menu options, and DMX values.
Download the User Manual from
www.chauvetnrofessional.com for more
details.
Disclaimer
The information and specifications contained in this QRG are subject to
change without notice.
LIMITED WARRANTY
FOR WARRANTY REGISTRATION AND COMPLETE TERMS AND CONDITIONS PLEASE VISIT OUR WEBSITE. For Customers in the United States and Mexico: www.chauvetliahtina.com/warrantv- registration.
For Customers in the United Kingdom, Republic of Ireland, Belgium, the
Netherlands, Luxembourg, France, and
Germany: www.chauvetliahtina.eu/warranty-
registration .
Chauvet warrants that this product shall be free from defects in material and workmanship under normal use, for the period specified in, and subject to the exclusions and limitations set forth in the full limited warranty on our website. This warranty extends only to the original purchaser of the product and is not transferable. To exercise rights under this warranty, you must provide proof of purchase in the form of an original sales receipt from an authorized dealer that shows the product name and date of purchase. THERE ARE NO OTHER EXPRESS OR IMPLIED WARRANTIES. This warranty gives you specific legal rights. You may also have other rights that vary from state to state and country to country. This warranty is valid only in the United States, United Kingdom, Republic of Ireland, Belgium, the Netherlands, Luxembourg, France, Germany, and Mexico. For warranty terms in other countries, please consult your local distributor.
Safety Notes
These Safety Notes include important information about installation, use,
and maintenance.
- This luminaire is intended for professional use only.
- DO NOT open this product. It contains no user-serviceable parts.
- DO NOT look at the light source when the product is on.
- CAUTION: Flashing light is known to trigger epileptic seizures. Users must comply with local laws regarding notification of strobe use.
- To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the product from power via a breaker or by unplugging it.
- CAUTION: When transferring product from extreme temperature environments, (e.g. cold truck to a warm humid ballroom) condensation may form on the internal electronics of the product. To avoid causing a failure, allow the product to fully acclimate to the surrounding environment before connecting it to power.
- CAUTION: This product’s housing may be hot when lights are operating.
- Mount this product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.
- The luminaire should be positioned so that prolonged staring into it at a distance closer than 15.4 ft (4.7 m) is not expected.
- DO NOT leave any flammable material within 20 cm of this product while operating or connected to power.
- USE a safety cable when mounting this product overhead.
- DO NOT operate this product outdoors or in any location where dust, excessive heat, water, or humidity may affect (IP20)
- DO NOT operate this product if the housing, lenses, or cables appear damaged.
- DO NOT connect this product to a dimmer or rheostat.
- ONLY connect this product to a grounded and protected circuit.
- ONLY use the hanging/mounting bracket or the handles to carry this product.
- If the external flexible cable or cord of this luminaire is damaged, it shall be replaced with a special cable or cord exclusively available from the manufacturer or its service agent.
- The light source contained in this luminaire shall only be replaced by the manufacturer, its service agent, or a similarly qualified person.
- The maximum ambient temperature is 113 °F (45 °C). Do not operate this product at higher temperatures. In the event of a serious operating problem, stop using immediately.
FCC Compliance
This device complies with Part 15 Part B of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
RF Exposure Warning for North America, and Australia
Warning! This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Contact
Outside the U.S., U.K., Ireland, Benelux, France, Germany, or Mexico, contact your distributor to request support or return a product. Refer to Contact t is at the end of this QRG for contact information.
What is Included
- Maverick Force s Profile 2 Omega brackets with mounting hardware
- Electronic Powerkon IP65 power cord Quick Reference Guide
AC Power
This product has an auto-ranging power supply that can work with an input voltage range of 100-240 VAC, 50/60 Hz. Power Linking
It is possible to link up to 2 Maverick Force s Profile products at 100 V, 2 products at 120 V, 5 products at 208 V,
4 products at 230 V, or 5 products at 240 V. Never exceed this number. Power- linking cords can be purchased separately.
AC Plug
Connection | Wire (U.S.) | Wire (Europe) | Screw Color |
---|---|---|---|
AC Live | Black | Brown | Yellow/Color |
AC Neutral | White | Blue | Silver |
AC Ground | Green/Yellow | Green/Yellow | Green |
To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the product from power via a breaker or by unplugging it.
Replacing the Fuse
- Disconnect the product from power.
- Using a flat head screwdriver, unscrew the fuse holder cap from the housing.
- Remove the blown fuse and replace it with a good fuse of the same type and rating.
- Screw the fuse holder cap back in place and reconnect the power.
DMX Linking
The Maverick Force s Profile will work with a DMX controller using a 3- or
5-pin DMX serial connection or a wireless DMX connection. A DMX Primer is
available from
www.chauvetprofessional.com .
DMX Connection
The Maverick Force s Profile uses a 3- or 5-pin DMX data connection or a
wireless DMX connection for its DMX personalities: 31Ch and 47Ch. See the
User Manual for information about connecting and configuring the product for
DMX operation.
RDM (Remote Device Management)
Remote Device Management, or RDM, is a standard for allowing DMX-enabled
devices to communicate bi-directionally along with existing DMX cabling. Check
the DMX controller’s User Manual or with the manufacturer as not all DMX
controllers have this capability. The Maverick Force s Profile supports the
RDM protocol that allows feedback to make changes to menu map options.
Download the User Manual from
www.Chauvetprofessional.com for more
details.
Signal Connection
The Maverick Force s Profile can link to controller software using an
Ethernet connection. If using other Art-Net” or sACN -compatible products with
the Maverick Force s Profile, you can control each individually on a single
network. See the User Manual for information about how to connect and
configure the product for these signals.
Art-NetTM Connection
ArtNetTM is an Ethernet protocol that uses TCP/IP which transfers a large
amount of DMX512 data using a Neutrik® etherCON® RJ45 connection over a large
network. An Art-NetTm protocol document is available from
www.chauvetprofessional.com . Chauvet
Professional recommends using unicast ArtNetTM for best results.
Art-Net” designed by and copyrighted Artistic Licence Holdings Ltd.
sACN Connection
Also known as ANSI E1.31, Streaming-ACN is an Ethernet protocol that uses
the layering and formatting of Architecture for Control Networks to transport
DMX512 data over IP or any other ACN compatible network.
Mounting
Before mounting this product, read the Safety Notes. Use at least two mounting points per product. Make sure the mounting clamps are capable of supporting the weight of the product. For our Chauvet line of mounting clamps, go to http://trusst.com/product/truss-clam Ds/.
Mounting Diagram
Control Panel Description
Button | Name | Function |
---|---|---|
< UP> | Navigates upwards through the menu list or increases the numeric |
value when in a function
< MENU>| Exits from the current menu or function
< DOWN>| Navigates downwards through the menu list or decreases the
numeric value when in a function
< LEFT>| Navigates leftwards through the menu list
< ENTER>| Enables the currently displayed menu or sets the currently
selected value into the selected function
< RIGHT>| Navigates rightwards through the menu list
Battery Powered Display
Press and hold until the menu screen appears (approximately 15 seconds).
Technician Mode
The technician mode disables the pan and tilt motors, allowing the output
of the product to be aimed by hand. To enable the technician mode of the
Maverick Force s Profile, hold < UP> and < LEFT> while the product is
powering on. When the product is turned off and back on, the pan and tilt will
return to normal function.
Menu Map
Refer to the Maverick Force s Profile product page on www.chauvetorofessional.com for the latest menu map.
Main Level | Programming Levels | Description |
---|---|---|
Address | 001 – 480 | Sets the starting address |
Network
Setup| | Manual| Manually set IP address
IP Mode| DHCP| Network sets the IP address
| Static| Product sets the IP address
Universe| 000 – 255 (Art-NetTM)
001 – 256 (sACN)| Sets the universe
ip| —————————-| Sets the IP address in Manual mode
SubMask| —————————-| Sets the Subnet Mask in Manual mode
Personality| Dmx Mode 31 CH| NO| Selects the 31-channel mode
YES
Dmx Mode 47 CH| NO| Selects the 47-channel mode
YES
Settings| Control Mode| DMX| Sets the control protocol
WDMX
ArtNet
sACN
Pan Reverse| NO| Normal pan
YES| Reversed pan
Tilt Reverse| NO| Normal tilt
YES| Reversed tilt
Screen Reverse| NO| Normal display
YES| Inverted display
AUTO| Automatic display orientation
Pan Angle| 540| 540° pan range
360| 360° pan range
180| 180° pan range
Tilt Angle| 270| 270° tilt range
180| 180° tilt range
90| 90° tilt range
BL 0. PR Move Move| | Do not blackout while panning/tilting
YES| Blackout while panning/tilting
BL. 0. Color Move| NO| Do not blackout while the color wheel moving
YES| Blackout while the color wheel moving
BL. 0. Gobo Move| NO| Do not blackout while gobo wheels moving
YES| Blackout while gobo wheels moving
Calibration| NO| Calibration disabled
YES| Calibration enabled
Touchscreen Lock| NO| Touch screen enabled
YES| Touch screen disabled
Lock Screen| NO| Lock the buttons and touch screen Passcode: 2323
YES
Swap XY| NO| Do not swap pan and tilt
YES| Pan controls tilt, tilt controls pan
Settings (coat.)| Backlight Timer| The 30S| The display turns off
after 30 seconds
---|---|---|---
1M| The display turns off after 1 minute
5M| The display turns off after 5 minutes
ON| Display stays on
Loss of Data| Hold| Holds the last signal received
Close| Blacks out fixture
Fans| Auto| Fan speed according to product temperature
Full| Fan speed set on high
ECO| Quiet mode
TV25| Maintains LED output up to an ambient temperature of 77 °F (25 °C)
(TV25) or 95 °F (35 °C) (TV35).
When using these fan modes, please set the PWM Options to 6000Hz or 15000Hz to prevent any possible harmonization noise.
TV35
Dimmer Curve| Linear| Sets the dimmer curve
Square
I Squad
S-Curve
Linear2
PWM Option| 600Hz| Sets the Pulse Width Modulation frequency
1200Hz
4000Hz
6000Hz
15000Hz
LED Power| 064-255| Sets the maximum LED output
Min Zoom Focus| NO| Enables/disables minimum zoom focus
YES
Preset Select| PRESET A| Recorded preset menu options
PRESET B
PRESET C
Preset Sync| NO| Allows recorded preset menu options to be
transferred to other Maverick Force s Profile fixtures in the DMX daisy chain
YES
USB Update| NO| Enables/disables updating by USB
YES
Reset
Function| Pan/Tilt| NO/YES| Reset individual functions or all
functions from start-up
Iris/Prism
Color/CMY/Blade
Gobo/Gobo Rotate
Frost
All
Factory Settings| NO| Reset to factory default settings
YES
Test| Auto Test| Autotest all functions
Test
(cont.)| Manual Test| Pan| 000-255| Manually control and test all settings
through the control panel
---|---|---|---|---
Pan Fine
Tilt
Tilt Fine
PIT Speed
Dimmer
Dimmer Fine
Shutter
Virtual Shaking
Cyan
Magenta
Yellow
Color
Gobo
Gobo Rotate
Gobo Index
Gobo2
Bladel- 1
Bladel- 1 Fine
Bladel- 2
Bladel- 2 Fine
Blade2- 1
Blade2- 1 Fine
Blade2- 2
Blade2- 2 Fine
Blade3- 1
Blade3- 1 Fine
Blade3- 2
Blade3- 2 Fine
Blade4- 1
Blade4- 1 Fine
Blade4- 2
Blade4- 2 Fine
Blade Rotate
Blade Rotate Fine
Focus
Focus Fine
Focus Auto
Zoom
Zoom Fine
Prism
Prism Rotate
Iris
Frost
CMY Macro
CMY Macro Speed
Special Function
Information| Fixture
Information| Ver| V_| Shows firmware version
---|---|---|---|---
Running Mode|
— — — —
| Shows the current running mode
DMX Address|
— — — —
| Shows current starting address
Temperature|
— — —
| Shows current product temperature in °C
Fixture Hours|
— — — —
| Shows the number of hours the product has been powered on
Ip|
— — — —
| – Shows the current IP address
SubMask|
— — — —
| – Shows current Subnet Mask
MAC|
— — — —
| – Shows current MAC address
Fan
Information| Head Fan1 Speed| — — — — — —| Shows speed of head
and base fans in rpm
Head Fan2 Speed
Base Fan1 Speed
Base Fan2 Speed
Error Information| — — — — —| Shows any errors, or No Error!
Channel
Information| Pan| 000-255| Shows all current values from input
signals
Pan Fine
Tilt
Tilt Fine
PIT Speed
Dimmer
Dimmer Fine
Shutter
Virtual Shaking
Cyan
Magenta
Yellow
Color
Gobo
Gobo Rotate
Gobo Index
Gobo2
Blade1-1
Blade1-1 Fine
Blade1-2
Bladel- 2 Fine
Blade2- 1
Blade2- 1 Fine
Blade2- 2
Blade2- 2 Fine
Blade3- 1
Blade3- 1 Fine
Blade3- 2
Blade3- 2 Fine
Blade4- 1
Blade4- 1 Fine
Blade4- 2
Blade4- 2 Fine
Information
(cont.)| Channel Information
(cont.)| Blade Rotate| 000 – 255| Shows all current
values from input signals
---|---|---|---|---
Blade Rotate Fine
Focus
Focus Fine
Focus Auto
Zoom
Zoom Fine
Prism
Prism Rotate
Iris
Frost
CMY Macro
CMY Macro Speed
Special Function
DMX Values
Dmx Mode 47 CH
Channel | Function | Value | Percent/Setting |
---|---|---|---|
1 | Pan | 000 255 | 0-100% |
2 | Fine pan | 000 255 | Fine control (16-bit) |
3 | Tilt | 000 255 | 0-100% |
4 | Fine tilt | 000 255 | Fine control (16-bit) |
5 | Pan/tilt speed | 000 255 | Fast to slow |
6 | Dimmer | 000 255 | 0-100% |
7 | Fine dimmer | 000 255 | Fine control (16-bit) |
8 | Strobe | 000 003 |
004 007
008 076
077 145
146 215
216 255
| Closed
Open
Strobe, slow to fast Pulse strobe, slow to fast
Random strobe, slow to fast
Open
9| Virtual strobe| 000 001
002 128
129 255
| No function
Shaking strobe, slow to fast
Fading shake, slow to fast
10| Cyan| 000 255| 0-100%
11| Magenta| 000 255| 0-100%
12| Yellow| 000 255| 0-100%
13| Color wheel| 000 006
007 013
014 020
021 027
028 034
035 041
042 048
049 059
060 187
188 219
220 223
224 255
| Open
Red
Orange
Green
Magenta
UV
CRI
CTB
Split colors
Color scroll, fast to slow
Stop
Reverse color scroll, slow to fast
14
|
Gobo wheel 1 (rotating)
(see Gobo Desicins)
| 000 007
008 015
016 023
024 031
032 039
040 047
048 055
056 063
064 071
072 079
080 087
088 095
096 103
104 111
112 119
120 127
128 191
192 255| Open
Gobo 1 (sailboats)
Gobo 2 (radial dot)
Gobo 3 (mower blade)
Gobo 4 (bolts)
Gobo 5 (shower glass)
Gobo 6 (ballistic clouds)
Gobo 7 (four eyes)
Gobo 7 shaking
Gobo 6 shaking
Gobo 5 shaking
Gobo 4 shaking
Gobo 3 shaking
Gobo 2 shaking
Gobo 1 shaking
Open
Gobo scroll, slow to fast
Reverse gobo scroll, slow to fast
---|---|---|---
15
|
Gobo 1 rotation
| 000 063
064 145
146 149
150 231
232 255
| Gobo index
Gobo rotation, fast to slow
Stop
Reverse gobo rotation, slow to fast
Bounce effect, short to long
16| Find gobo 1 rotation| 000 255| Fine control (16-bit)
17
|
Gobo wheel 2 (static)
(see Gobo Desi.ns)
| 000 005| Open
006 011| Gobo 1 (beam)
012 017| Gobo 2 (bars)
018 023| Gobo 3 (circles)
024 029| Gobo 4 (breakup)
030 035| Gobo 5 (dots)
036 041| Gobo 6 (circuits)
042 047| Gobo 7 (triangles)
048 053| Gobo 8 (forest)
054 063| Gobo 9 (rainbows)
064 069| Gobo 9 shaking
070 075| Gobo 8 shaking
076 081| Gobo 7 shaking
082 087| Gobo 6 shaking
088 093| Gobo 5 shaking
094 099| Gobo 4 shaking
100 105| Gobo 3 shaking
106 111| Gobo 2 shaking
112 117| Gobo 1 shaking
118 127| Open
128 191| Gobo scroll, slow to fast
192 255| Reverse gobo scroll, slow to fast
18| Blade 1-1| 000 255| 0-100%
19| Blade 1-1 fine| 000 255| Fine control (16-bit)
20| Blade 1-2| 000 255| 0-100%
21| Blade 1-2 fine| 000 255| Fine control (16-bit)
22| Blade 2-1| 000 255| 0-100%
23| Blade 2-1 fine| 000 255| Fine control (16-bit)
24| Blade 2-2| 000 255| 0-100%
25| Blade 2-2 fine| 000 255| Fine control (16-bit)
26| Blade 3-1| 000 255| 0-100%
27| Blade 3-1 fine| 000 255| Fine control (16-bit)
---|---|---|---
28| Blade 3-2| 000 255| 0-100%
29| Blade 3-2 fine| 000 255| Fine control (16-bit)
30| Blade 4-1| 000 255| 0-100%
31| Blade 4-1 fine| 000 255| Fine control (16-bit)
32| Blade 4-2| 000 255| 0-100%
33| Blade 4-2 fine| 000 255| Fine control (16-bit)
34| Frame rotation| 000 255| 0-100%
35| Frame tine rotation| 000 255| Fine control (16-bit)
36| Focus| 000 255| 0-100%
37| Fine focus| 000 255| Fine control (16-bit)
38| Autofocus| 000 010
011 030
031 050
051 070
071 090
091 110 0
111 ****130
131 ****150
151 ****170
171 ****190
191 ****210
211 ****255
| No function
0-5 m
6 m
7 m
8 m
9 m
10 m
12.5 m
15 m
17.5 m
20-60 m
Auto-detect distance
39| Zoom| 000 **255| 0-100%
40| Fine zoom| 000 **255| Fine control (16-bit)
41| Prism| 000 004
005 255| No function Prism effect
42| Prism rotation| 000 127
128 189
190 193
194 255| Prism index
Prism rotation, fast to slow
Stop
Reverse prism rotation, slow to fast
43| Iris| 000 ****063
064 ****127
128 ****191
192 ****255
| 0-100%
Auto change, slow to fast
Slow expand, fast shrink (slow to fast)
Slow shrink, fast expand (slow to fast)
44| Frost| 000 **255| 0-100%
45| CMY macro| 000 **009
010 014
015 020
021 **255| No function
Full CTO
½ CTO
CMY macro
46| CMY macro speed| 000 **255| CMY macro speed, fast to slow
47| Control| 000 ****007
008 ****015
016 ****023
024 ****031
032 ****039
040 ****047
048 ****055
056 ****095
096 ****103
104 ****111
112 ****119
120 ****127
128 ****131
132 ****135
136 ****143
144 ****151
152 ****159
160 ****167
168 ****175
176 ****183
184 ****191
192 ****199
200 ****207
208 ****215
216 ****217
218 ****220
221 ****225
226 ****230
231 ****235
236 ****240
241 ****245
246 ****250
251 ****255
| No function
Pan tilt blackout
Color blackout
Gobo blackout
Pan tilt/color blackout
Pan tiltlgobo blackout
Pan tilt/color/gobo blackout
No function
Pan reset
Tilt reset
Color reset
Gobo reset
High color temperature gobo on
High color temperature gobo off
Prism reset
Frame shutter reset
All reset
Iris reset
Frost reset
Zoom reset
CMY reset
Fan ECO
Fan full
Fan auto
Fan TV25
Fan TV35
Iris fast mode
Iris smooth mode
Pan tilt swap on
Pan tilt swap off
Min Zoom Focus on
Min Zoom Focus off
No function
---|---|---|---
Dmx Mode 31 CH
Channel | Function | Value | Percent/Setting |
---|---|---|---|
1 | Pan | 000 ****255 | 0-100% |
2 | Fine pan | 000 ****255 | Fine control (16-bit) |
3 | Tilt | 000 ****255 | 0-100% |
4 | Fine tilt | 000 ****255 | Fine control (16-bit) |
5 | Pan/tilt speed | 000 ****255 | Fast to slow |
6 | Dimmer | 000 ****255 | 0-100% |
Strobe | 000 ****003 |
004 007
008 076
077 145
146 215
216 **255| Closed
Open
Strobe, slow to fast Pulse strobe, slow to fast
Random strobe, slow to fast
Open
7
8| Virtual strobe| 000 **001
002 ****128
129 ****255
| No function
Shaking strobe, slow to fast
Fading shake, slow to fast
9| Cyan| 000 **255| 0-100%
10| Magenta| 000 **255| 0-100%
11| Yellow| 000 **255| 0-100%
12| Color wheel| 000 **006
007 ****013
014 ****020
021 ****027
028 ****034
035 ****041
042 ****048
049 ****059
060 ****187
188 ****219
220 ****223
224 ****255
| Open
Red
Orange
Green
Magenta
CRI
UV
CTB
Split colors
Color scroll, fast to slow
Stop
Reverse color scroll, slow to fast
13| Gobo wheel 1 (rotating)
(see Gobo Designs)| 000 ****007
008 ****015
016 ****023
024 ****031
032 ****039
040 ****047
048 ****055
056 ****063
064 ****071
072 ****079
080 ****087
088 ****095
096 ****103
104 ****111
112 ****119
120 ****127
128 ****191
192 ****255
| Open
Gobo 1 (sailboats)
Gobo 2 (radial dot)
Gobo 3 (mower blade)
Gobo 4 (bolts)
Gobo 5 (shower glass)
Gobo 6 (ballistic clouds)
Gobo 7 (four eyes)
Gobo 7 shaking
Gobo 6 shaking
Gobo 5 shaking
Gobo 4 shaking
Gobo 3 shaking
Gobo 2 shaking
Gobo 1 shaking
Open
Gobo scroll, slow to fast
Reverse gobo scroll, slow to fast
14| Gobo 1 rotation| 000 ****063
064 ****145
146 ****149
150 ****231
232 ****255
| Gobo index
Gobo rotation, fast to slow
Stop
Reverse gobo rotation, slow to fast
Bounce effect, short to long
15| Gobo wheel 2 (static)
(see Gobo f)Asians)| 000 ****005
006 ****011
012 ****017
018 ****023
024 ****029
030 ****035
036 ****041
042 ****047
048 ****053
054 ****063
064 ****069
070 ****075
076 ****081
082 ****087
088 ****093
094 ****099
100 ****105
106 ****111
112 ****117
118 ****127
128 ****191
192 ****255
| Open
Gobo 1 (beam)
Gobo 2 (bars)
Gobo 3 (circles)
Gobo 4 (breakup)
Gobo 5 (dots)
Gobo 6 (circuits)
Gobo 7 (triangles)
Gobo 8 (forest)
Gobo 9 (rainbows)
Gobo 9 shaking
Gobo 8 shaking
Gobo 7 shaking
Gobo 6 shaking
Gobo 5 shaking
Gobo 4 shaking
Gobo 3 shaking
Gobo 2 shaking
Gobo 1 shaking
Open
Gobo scroll, slow to fast
Reverse gobo scroll, slow to fast
---|---|---|---
16| Blade 1-1| 000 **255| 0-100%
17| Blade 1-2| 000 **255| 0-100%
18| Blade 2-1| 000 **255| 0-100%
19| Blade 2-2| 000 **255| 0-100%
20| Blade 3-1| 000 **255| 0-100%
21| Blade 3-2| 000 **255| 0-100%
22| Blade 4-1| 000 **255| 0-100%
23| Blade 4-2| 000 **255| 0-100%
24| Frame rotation| 000 **255| 0-100%
25| Focus| 000 **255| 0-100%
26| Zoom| 000 **255| 0-100%
27| Prism| 000 **004
005 **255| No function Prism effect
28| Prism rotation| 000 **127
128 189
190 193
194 **255| Prism index
Prism rotation, fast to slow
Stop
Reverse prism rotation, slow to fast
29| Iris| 000 **063
064 127
128 191
192 **255| 0-100%
Auto change, slow to fast
Slow expand, fast shrink (slow to fast)
Slow shrink, fast expand (slow to fast)
30| Frost| 000 **255| 0-100%
31| Control| 000 ****007
008 ****015
016 ****023
024 ****031
032 ****039
040 ****047
048 ****055
056 ****095
096 ****103
104 ****111
112 ****119
120 ****127
128 ****131
132 ****135
136 ****143
144 ****151
152 ****159
160 ****167
168 ****175
176 ****183
184 ****191
192 ****199
200 ****207
208 ****215
216 ****217
218 ****220
221 ****225
226 ****230
231 ****235
236 ****240
241 ****245
246 ****250
251 ****255
| No function
Pan tilt blackout
Color blackout
Gobo blackout
Pan tilt/color blackout
Pan tilt/gobo blackout
Pan tilt/color/gobo blackout
No function
Pan reset
Tilt reset
Color reset
Gobo reset
High color temperature gobo on
High color temperature gobo off
Prism reset
Frame shutter reset
All reset
Iris reset
Frost reset
Zoom reset
CMY reset
Fan ECO
Fan full
Fan auto
Fan TV25
Fan TV35
Iris fast mode
Iris smooth mode
Pan tilt swap on
Pan tilt swap off
Min Zoom Focus on
Min Zoom Focus off
No function
---|---|---|---
Gobo Designs
Contact Us
General Information | Technical Support |
---|
Chauvet World Headquarters
Address: 5200 NW 108th Ave.
Sunrise, FL 33351
Voice: 954-577-4455
Fax: 954-929-5560
Toll-Free: 800-762-1084
| Voice: 844-393-7575
Fax: 954-756-8015
Email: chauvetcsechauvetlichtine.com
Website: www.
chauvetorofessional.com
Visit the applicable website above to verify our contact information and instructions to request support. Outside the U.S., U.K., Ireland, Mexico, France, Germany, or Benelux, contact the dealer of record.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>