CHAUVET PROFESSIONAL STRIKE 1 LED Blinder User Guide
- June 3, 2024
- Chauvet Professional
Table of Contents
Quick Reference Guide Model ID: STRIKE1
STRIKE 1 LED Blinder
About This Guide
The STRIKE 1 Quick Reference Guide (QRG) has basic product information such as
connection, mounting, menu options, and DMX values. Download the User Manual
from www.chauvetprofessional.com for
more details.
Disclaimer
The information and specifications contained in this QRG are subject to change
without notice.
LIMITED WARRANTY
FOR WARRANTY REGISTRATION AND COMPLETE TERMS AND CONDITIONS PLEASE VISIT OUR
WEBSITE.
For Customers in the United States and Mexico: www.chauvetlighting.com
/warranty-registration.
For Customers in the United Kingdom, Republic of Ireland, Belgium, the
Netherlands, Luxembourg, France, and Germany: www.chauvetlighting.eu
/warranty-registration.
Chauvet warrants that this product shall be free from defects in material and
workmanship under normal use, for the period specified in, and subject to the
exclusions and limitations set forth in the full limited warranty on our
website. This warranty extends only to the original purchaser of the product
and is not transferable. To exercise rights under this warranty, you must
provide proof of purchase in the form of an original sales receipt from an
authorized dealer that shows the product name and date of purchase. THERE ARE
NO OTHER EXPRESS OR IMPLIED WARRANTIES. This warranty gives you specific legal
rights. You may also have other rights that vary from state to state and
country to country. This warranty is valid only in the United States, United
Kingdom, Republic of Ireland, Belgium, the Netherlands, Luxembourg, France,
Germany and Mexico. For warranty terms in other countries, please consult your
local distributor.
Safety Notes
- DO NOT open this product. It contains no user-serviceable parts.
- The luminaire should be positioned so that prolonged staring into the luminaire at a distance closer than 7.6 ft (2.3 m) is not expected.
- If the external flexible cable or cord of this luminaire is damaged, it shall be replaced by a special cord or cord exclusively available from the manufacturer or his service agent.
- The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person.
- The luminaire is intended for professional use only.
- To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the product from power via breaker or by unplugging it.
- DO NOT look at the light source when the product is on.
- CAUTION: Flashing light is known to trigger epileptic seizures. User must comply with local laws regarding notification of strobe use.
- CAUTION: This product’s housing may be hot when lights are operating.
- Mount this product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.
- DO NOT leave any flammable material within 7.9 in (0.2 m) to all exterior surfaces of the luminaire.
- CAUTION: When transferring product from extreme temperature environments, (e.g., cold truck to warm humid ballroom) condensation may form on the internal electronics of the product. To avoid causing a failure, allow product to fully acclimate to the surrounding environment before connecting it to power.
- USE a safety cable when mounting this product overhead.
- DO NOT submerge this product (IP65). Regular outdoor operation is fine.
- DO NOT operate this product if the housing, lenses, or cables appear damaged.
- DO NOT connect this product to a dimmer or rheostat.
- ONLY connect this product to a grounded and protected circuit.
- ONLY use the hanging/mounting bracket to carry this product.
- In the event of a serious operating problem, stop using immediately.
- The maximum ambient temperature is 113 °F (45 °C). Do not operate this product at higher temperatures.
Contact
Outside the U.S., U.K., Ireland, Benelux, France, Germany, or Mexico,
contact your distributor to request support or return a product. Refer to
Contact Us at the end of this QRG for contact information.
What is Included
- STRIKE 1
- Seetronic Powerkon IP65 power cord
- Multi-Bracket
- Quick Reference Guide
AC Power
This product has an auto-ranging power supply that can work with an input
voltage range of 100–240 VAC, 50/60 Hz.
Power Linking
You can link up to 6 STRIKE 1 products at 120 VAC, 10 at 208 VAC, or 11
products at 230 VAC. Never exceed this number. Power linking cords can be
purchased separately.
AC Plug
Connection | Wire (U.S.) | Wire (Europe) | Screw Color |
---|---|---|---|
AC Live | Black | Brown | Yellow/Brass |
AC Neutral | White | Blue | Silver |
AC Ground | Green/Yellow | Green/Yellow | Green |
To eliminate unnecessary wear and improve its lifespan, during periods of non-
use completely disconnect the product from power via breaker or by unplugging
it.
DMX Linking
The STRIKE 1 will work with a DMX controller using a 5-pin DMX serial
connection. A DMX Primer is available from
www.chauvetprofessional.com.
DMX Connection
The STRIKE 1 uses a 5-pin DMX data connection for its DMX personalities: 1 Ch,
3 Ch, 4 Ch, 5 Ch, and 6 Ch. See the User Manual for information about
connecting and configuring the product for DMX operation.
Master/Slave Connection
The STRIKE 1 uses the DMX data connection for its Master/Slave mode. See the
User Manual for information about how to connect and configure the product for
master/slave operation.
RDM (Remote Device Management)
Remote Device Management, or RDM, is a standard for allowing DMX-enabled
devices to communicate bi-directionally along existing DMX cabling. Check the
DMX controller’s User Manual or with the manufacturer as not all DMX
controllers have this capability. The STRIKE 1 supports RDM protocol that
allows feedback to make changes to menu map options.
Download the User Manual from
www.chauvetprofessional.com for more
details.
Mounting
Before mounting this product, read the Safety Notes.
STRIKE 1 Multi-Bracket
The STRIKE 1 Multi-Bracket allows the creation of multi-fixture banks with
ease. Link up to 4 products vertically from any mounting point. The included
spacer bar maintains horizontal pixel pitch. Make sure the mounting clamps are
capable of supporting the combined weight of the products. For our CHAUVET
Professional line of mounting clamps, go to http://trusst.com/products.
Multi-Bracket Overview
Multi-Bracket
| Spacer-bar
(maintains horizontal pixel pitch)|
Spacer
(stabilizes brackets)
Product Mounting Diagram
- Secure all safety cables to the mounting surface, NOT the multi-bracket.
- Do not mount more than 4 products vertically from one mounting point.
- Ensure any mounting surface you plan to use is capable of supporting the weight of all products being mounted.
Control Panel Description
Button | Function |
---|---|
< MENU> | Exits from the current menu or function |
< ENTER> | Enables the currently displayed menu or sets the currently |
selected value into the selected function
< UP>| Navigates upwards through the menu list or increases the numeric
value when in a function
< DOWN>| Navigates downwards through the menu list or decreases the
numeric value when in a function
Menu Map
Main Level | Programming Levels | Description |
---|---|---|
DMX Address | Address | < 001-512> |
channel restricted to personality chosen)
DMX Channel| 1 Ch| 1-channel: dimmer
3 Ch| 3-channel: dimmer, red shift, dimmer speed
4 Ch| 4-channel: 16-bit dimmer, red shift, dimmer speed
5 Ch| 5-channel: dimmer, red shift, strobe, auto, dimmer speed
6 Ch| 6-channel: 16-bit dimmer, red shift, strobe, auto, dimmer speed
Static| Dimmer| < 0-255>| Sets the intensity of the light
output
Strobe| Selects the strobe frequency
Auto Show| Auto 1-3| < 001-100>| Automatic programs
Red Shift| On| Turns on or off Red Shift (Amber LEDs imitate lamp
when dimming
Off
Master/Slave Mode| Master| Master mode
Slave| DMX mode (Slave mode)
Dimmer Mode| Off| No dimmer curve
Dimmer 1–3| Dimming curves Dimmer 1 (fast) to Dimmer 3 (slow)
Main Level| Programming Levels| Description
---|---|---
LED Frequency| 600Hz| PWM frequency
1200Hz
2000Hz
4000Hz
25KHz
Fan Mode| Auto| Fan Control
On
Back Light| On| Display backlight always on
10S| Turns off display backlight after 10 seconds of inactivity
20S| Turns off display backlight after 20 seconds of inactivity
30S| Turns off display backlight after 30 seconds of inactivity
Key Lock| On| Locks display (password is < UP>, < DOWN>,
< UP>, < DOWN>, < ENTER>)
Off
Information| Fixture Hours| Shows total product hours
Version| Shows installed software version
UID| Shows product ID
Reset Factory| No| Reset to factory defaults
Yes
**DMX Values
**
6 Ch
Channel | Function | Value | Percent/Setting |
---|---|---|---|
1 | Dimmer | 000 ⇔ 255 | 0-100% |
2 | Fine Dimmer | 000 ⇔ 255 | 0-100% |
3 | Red Shift | 000 | |
001 ⇔ 255 | On |
Off
4| Strobe| 000 ⇔ 010
011⇔ 255| No function
Strobe, slow to fast
5| Auto Program| 000 ⇔ 010
011 ⇔ 080
081 ⇔ 160
161 ⇔ 240
241 ⇔ 255| No function
Auto 1, slow to fast
Auto 2, slow to fast
Auto 3, slow to fast
No function
6| **Dimmer Speed***| 000 ⇔ 051
052 ⇔ 101
102 ⇔ 152
153 ⇔ 203
204 ⇔ 255| Current dimmer speed mode
Dimmer speed mode off (linear dimmer)
Dimmer speed mode 1 (fastest)
Dimmer speed mode 2
Dimmer speed mode 3 (slowest)
5 Ch
Channel | Function | Value | Percent/Setting |
---|---|---|---|
1 | Dimmer | 000 ⇔255 | 0-100% |
2 | Red Shift | 000 | |
001 ⇔ 255 | On |
Off
3| Strobe| 000 ⇔ 010
011 ⇔ 255| No function
Strobe, slow to fast
4| Auto Program| 000 ⇔ 010
011 ⇔ 080
081 ⇔ 160
161 ⇔ 240
241 ⇔ 255| No function
Auto 1, slow to fast
Auto 2, slow to fast
Auto 3, slow to fast
No function
5| **Dimmer Speed***| 000 ⇔ 051
052 ⇔ 101
102 ⇔ 152
153 ⇔ 203
204 ⇔ 255| Current dimmer speed mode
Dimmer speed mode off (linear dimmer)
Dimmer speed mode 1 (fastest)
Dimmer speed mode 2
Dimmer speed mode 3 (slowest)
*Hold desired dimmer speed value for 3 seconds, then release. This changes the dimmer speed setting in the menu.
4 Ch
Channel | Function | Value | Percent/Setting |
---|---|---|---|
1 | Dimmer | 000 ⇔ 255 | 0-100% |
2 | Fine Dimmer | 000 ⇔ 255 | 0-100% |
3 | Red Shift | 000 | |
001 ⇔ 255 | On |
Off
4| **Dimmer Speed***| 000 ⇔ 051
052 ⇔ 101
102 ⇔ 152
153 ⇔ 203
204 ⇔ 255| Current dimmer speed mode
Dimmer speed mode off (linear dimmer)
Dimmer speed mode 1 (fastest)
Dimmer speed mode 2
Dimmer speed mode 3 (slowest)
3 Ch
Channel | Function | Value | Percent/Setting |
---|---|---|---|
1 | Dimmer | 000 ⇔ 255 | 0-100% |
2 | Red Shift | 000 | |
001 ⇔ 255 | On |
Off
Channel| Function| Value| Percent/Setting
---|---|---|---
3| **Dimmer Speed***| 000 ⇔ 051| Current dimmer speed mode
052 ⇔ 101| Dimmer speed mode off (linear dimmer)
102 ⇔ 152| Dimmer speed mode 1 (fastest)
153 ⇔ 203| Dimmer speed mode 2
204 ⇔ 255| Dimmer speed mode 3 (slowest)
*Hold desired Dimmer Speed value for 3 seconds, then release. This changes the Dimmer Speed setting in the menu.
1 Ch
Channel | Function | Value | Percent/Setting |
---|---|---|---|
1 | Dimmer | 000 ⇔ 255 | 0-100% |
Contact Us
General Information | Technical Support |
---|
Chauvet World Headquarters
Address: 5200 NW 108th Ave.
Sunrise, FL 33351
Voice: 954-577-4455
Fax: 954-929-5560
Toll Free: 800-762-1084| Voice:
844-393-7575
Fax: 954-756-8015
Email:
chauvetcs@chauvetlighting.com
Website: www.chauvetprofessional.com
Chauvet Europe Ltd.
Address: Unit 1C
Brookhill Road Industrial Estate
Pinxton, Nottingham, UK
NG16 6NT
Voice: +44 (0) 1773 511115
Fax: +44 (0) 1773 511110| Email:
UKtech@chauvetlighting.eu
Website: www.chauvetprofessional.eu
Chauvet Europe BVBA
Address: Stokstraat 18
9770 Kruishoutem
Belgium
Voice: +32 9 388 93 97| Email:
BNLtech@chauvetlighting.eu
Website: www.chauvetprofessional.eu
Chauvet France
Address: 3, Rue Ampère
91380 Chilly-Mazarin
France
Voice: +33 1 78 85 33 59| Email:
FRtech@chauvetlighting.fr
Website: www.chauvetprofessional.eu
Chauvet Germany
Address: Bruno-Bürgel-Str. 11
28759 Bremen
Germany
Voice: +49 421 62 60 20| Email:
DEtech@chauvetlighting.de
Website: www.chauvetprofessional.eu
Chauvet Mexico
Address: Av. de las Partidas 34 – 3B
(Entrance by Calle 2)
Zona Industrial Lerma
Lerma, Edo. de México, CP 52000
Voice: +52 728-690-2010| Email:
servicio@chauvet.com.mx
Website: www.chauvetprofessional.mx
Visit the applicable website above to verify our contact information and instructions to request support. Outside the U.S., U.K., Ireland, Mexico, France, Germany, or Benelux, contact the dealer of record.
STRIKE 1 QRG Rev. 7
Documents / Resources
|
CHAUVET PROFESSIONAL STRIKE 1 LED
Blinder
[pdf] User Guide
STRIKE 1 LED Blinder, STRIKE 1, LED Blinder, LED, Blinder
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>