Yorkville LP-LED2M Battery Powered Stage Lighting Lightbar Owner’s Manual

June 5, 2024
Yorkville

Yorkville LP-LED2M Battery Powered Stage Lighting Lightbar

Yorkville
-LP-LED2M -Battery-Powered-Stage-Lighting-Lightbar-
PRODUCT

IMPORTANT SAFETY INSTRUCTIONS

  • This lightning flash with an arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
  • The DO NOT STACK symbol is intended to alert the user that the product shall not be vertically stacked because of the nature of the product.
  • The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
  • SEPARATE COLLECTION WEEE
  • DO NOT PUSH OR PULL
  • NOT TO BE SERVICED BY USERS
  • CAUTION: OVERHEAD LOAD
  • ATTENTION: CHARGE

FOLLOW ALL INSTRUCTIONS: Instructions pertaining to a risk of fire, electric shock, or injury to a person

CAUTION

TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE THE COVER (OR BACK). NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. THIS DEVICE IS FOR INDOOR USE ONLY! INSTALLED BATTERY PACKS SHALL NOT BE EXPOSED TO EXCESSIVE HEAT SUCH AS SUNSHINE, FIRE, OR THE LIKE.

  • Read Instructions: The Owner’s Manual should be read and understood before the operation of your unit. Please, save these instructions for future reference and heed all warnings.
  • Cleaning: Clean only with a dry cloth.
  • Packaging: Keep the box and packaging materials, in case the unit needs to be returned for service.
  • Warning: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. Do not use this apparatus near water
  • Warning: When using electric products, basic precautions should always be followed, including the following:

Power Sources

Your unit should be connected to a power source only of the voltage specified in the owner’s manual or as marked on the unit. This unit has a polarized plug. Do not use with an extension cord or receptacle unless the plug can be fully inserted. Precautions should be taken so that the grounding scheme on the unit is not defeated. An apparatus with CLASS I construction shall be connected to a Mains socket outlet with a protective earthing connection. Where the MAINS plug or an appliance coupler is used as the disconnect device, the disconnect device shall remain readily operable.

Hazards

Do not place this product on an unstable cart, stand, tripod, bracket or table. The product may fall, causing serious personal injury and serious damage to the product. Use only with cart, stand, tripod, bracket, or table recommended by the manufacturer or sold with the product. Follow the manufacturer’s instructions when installing the product and use mounting accessories recommended by the manufacturer. Only use attachments/accessories specified by the manufacturer. Equipment that is suspended overhead must use a secondary safeguard to prevent personal injury in the event the primary mounting mechanism fails. Safety eyebolts attached to the equipment and galvanized steel wire can be used together to implement a failsafe mounting thus ensuring the safety of the equipment and anyone positioned below the equipment. Improper installation can result in bodily injury or death. If you are not qualified to attempt the installation get help from a professional structural rigger.

Note

Prolonged use of headphones at a high volume may cause health damage to your ears. The apparatus should not be exposed to dripping or splashing water; no objects filled with liquids should be placed on the apparatus. Terminals marked with the “lightning bolt” are hazardous live; the external wiring connected to these terminals requires installation by an instructed person or the use of ready-made leads or cords. Ensure that proper ventilation is provided around the appliance. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. No naked flame sources, such as lighted candles, should be placed on the apparatus.

Power Cord

Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for the replacement of the obsolete outlet. The AC supply cord should be routed so that it is unlikely that it will be damaged. Protect the power cord from being walked on or pinched particularly at plugs. If the AC supply cord is damaged DO NOT OPERATE THE UNIT. To completely disconnect this apparatus from the AC Mains, disconnect the power supply cord plug from the AC receptacle. The main plug of the power supply cord shall remain readily operable. Unplug this apparatus during lightning storms or when unused for long periods of time.

Service

The unit should be serviced only by qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, requires battery pack replacement or has been dropped. Disconnect power before servicing The Lightning Flash with an arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product enclosure that may be of sufficient magnitude to constitute a risk of shock to persons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product

  1. Read these instructions.
  2. Keep these instructions.
  3. Heed all warnings.
  4. Follow all instructions.
  5. Do not use this apparatus near water.
  6. Clean only with a dry cloth.
  7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
  8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
  9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prongs are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for the replacement of the obsolete outlet.
  10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
  11. Only use attachments/accessories specified by the manufacturer.
  12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
  13. Unplug this apparatus during lightning storms or when unused for long periods of time.
  14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

WARNING

  • To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture and objects filled with liquids, such as vases, should not be placed on this apparatus.
  • To completely disconnect this apparatus from the ac mains, disconnect the power supply cord plug from the ac receptacle.
  • The mains plug of the power supply cord or an appliance coupler shall remain readily accessible.

CAUTION: TO PREVENT ELECTRIC SHOCK HAZARD, DO NOT CONNECT TO MAINS POWER SUPPLY WHILE THE GRILLE IS REMOVED.

LP-LED2M

The Yorkville Sound LP-LED2M is a compact and dual-powered (battery and AC) lighting system. The LP-LED2M uses 2 lighting fixtures, called pods, mounted on a stand-mountable bar/controller. The bar houses the user controls, the connectors for a separate controller, the power supply, the battery, an internal charger, and mounting options. Each light pod uses 4 very high-power multi-die LED emitters that comprise a red, a green, a blue, and a white die. The addition of the white die provides a much more complete light spectrum; a more accurate color rendering of the objects and/or people illuminated. The light output of each pod is roughly equivalent to 300-watt bulbs with gels. At a distance of 6 feet, the light beam has a diameter of 3 feet. The diameter of the light at 12 feet is 5 feet. The light is mixed in the lens so that the mixed light color is visible when looking at the lens. Each pod may be adjusted in 2 axes.

The LP-LED Bars may be used in several ways

  1. Stand alone, no separate controller is required
  2. Linked to other LP-LED Bars with one as master
  3. With a Yorkville Lighting Controller. The Yorkville Sound LP-C12 and LP-C4 controllers allow for more functionality than the LP-LED Bars on their own.
  4. The older Yorkville Sound LP-608 can also be used but has limited functionality (see more detailed description below). When a Yorkville Sound Color Controller is used, the controls on the LP-LED Bars become inactive except for the Brightness Control.
  5. With a DMX™ Controller. The DMX™ signals pass through internal integrated DMX™ processing via a 3-pin standard XLR. Five separate modes are available with DMX512 addressing standard protocol.
  6. Bluetooth Smart™ device. Using our dedicated Android and iOS apps via any Bluetooth Smart™ enabled device. Effects and full manual RGBW color controls are available, along with extended Bluetooth™ effects such as strobe.

Function Control & Stand-Alone Operation

The Function Control allows you to set the basic operation of the LP-LED Bars. It allows you to power the unit on, off, choose Bluetooth™ operation or set a manual setting. When an LP-LED Bar is operated by itself (stand-alone) there are a number of modes that are set by the Function control:

  • ALL ON Lamp Color control (5 identical positions)
  • Bluetooth™ operation 4 separate settings (A, B, C, D)
  • Chase (5 speeds)
  • Single Color fade (6 speeds)
  • Multi-Color fade (4 speeds)
  • Audio effects via internal microphone (4) or via ¼-inch jack, triggering (4) (inserting a jack bypasses the internal microphone)Yorkville -LP-LED2M -Battery-Powered-Stage-Lighting-Lightbar-FIG-1

Bluetooth™ Smart Device

You must install the Yorkville LP Control App on your smart device prior to use. The App is available on the Apple App Store and the Google Play Store. The Bluetooth™ app may change and this description may not reflect the particular version the user has. There also may be additional features and details that may change. The number of bars connected may change along with a number of factors such as the digital device (phone or tablet), the software version in the bar / Bluetooth™ receiver, and the amount of Bluetooth™ traffic in the vicinity. To connect to a light bar, simply open the dedicated app and tap on the “Add Bar” button at the top of the screen. It will prompt you to enter a 4-digit pin code – if a bar is currently unsecured, any desired pin code can be entered. Security pin codes are cleared when the light bar is powered off or can be removed from the app. You can connect up to 4 bars at once. Once at least one bar has been connected, “help” and “connected devices” buttons will appear beside the “Add Bar Button,” along with: channel selection, individual head controllers, effects selection, and scene selection.

  • Channel Selection: Four channels are available, labeled A, B, C, and D. These correspond with the channel each light bar has been set to on the back of the bar. Any bar set to the currently selected channel will follow the given commands. For example, if two bars are connected and set to channel A, changing the first head color to red will cause the first heads specifically those two light bars to become red.

  • Individual Head Controls: the controls will appear as a color knob, an intensity slider, and a manual RGBW assignment button. Rotating the knob will cycle through the corresponding wheel colors, adjusting the intensity will affect the brightness level, and pressing the RGBW button will allow for manual RGBW color assignments.

  • Effects Selection: Eight effects are available. The first seven correspond with the effects on the light bar, while the eighth is an additional strobe effect. Individual head controls are disabled for that channel and scene until the effect is switched off.

  • Scene Selection: each scene will retain the configured head controls or effect for all 4 channels. 10 scenes are available and are automatically saved to device storage.

  • Brightness Control: The brightness of all pods varies from a minimum to a maximum with 32 positions. This control varies the brightness of all pods from any function position or any control source.

    • Note: The maximum brightness controlled by DMX or the Bluetooth™ app will depend on the manual brightness setting on the actual light bar.
  • Lamp Color Control: If using the Lamp Color control, any pod can be turned off by setting the Color control to the off position. There are 31 colors and color choices which begin with red, followed by blue, white, amber yellow, and finally green. There are also several choices of color temperature for white.

  • Fade / Multicolor Fade: The color fade speeds are fairly slow and are intended for gradually changing the lighting for a mood effect, chase speeds are faster and are also multi-color.

  • Color Sound to Light: The LP-LED Bars have sophisticated audio-to-light (color organ) circuitry. The automatic level circuitry allows it to be used with signals from weak line levels up to strong loudspeaker levels. The voltage range on the ¼-inch phone jack is 50mV to 100V. The LP-LED Bars have an internal microphone with automatic sensitivity. The microphone triggers the same sophisticated audio to light (color organ) circuitry as is used in the audio input jack.

    • Note: the microphone is active unless a ¼-inch phone jack is inserted into the audio input.
  • Mounting: For mounting on a standard loudspeaker stand please refer to the diagram “LP-LED Overhead Truss Mounting Instructions for Tripod Speaker Stand.” The stand adapter has a removable pin to allow multiple light bars per stand. For overhead truss mounting please refer to the diagram “LP-LED Overhead Truss Mounting Instructions.” As shown in the diagram you must use a safety cable to protect people and equipment in case the primary mounting hardware fails. This is unlikely to happen if the C-clamps are properly connected to the truss system but the addition of the safety cable is still a requirement. Improper installation can result in bodily injury or death. If you are not qualified to attempt the overhead installation get help from a professional structural rigger.

  • Using Multiple LP-LEDs: The Yorkville proprietary protocol connections and the DMX connections both allow for daisy-chaining. If one bar is used as a master to control other bars the Yorkville Protocol connections should be used to daisy chain from the master. A unit under Bluetooth™ control will output signals on the Yorkville Protocol jacks to allow daisy-chaining that mimics the bar under Bluetooth™ control.

  • LP-LED2M 1,2/3,4 Switch: The LP-LED2M has 2 light pods but the Yorkville lighting controllers such as the LP-C4 or LP-C12 use a 4-channel signal. The 1,2/3,4 switch selects which 2 of the 4 channels the bar responds to.

  • Power Consumption: The advantage of using LED versus conventional incandescent lighting is two-fold, not only does the unit give off less heat but also consumes less than 5-20% of the energy. This eliminates the need for separate AC power circuits just to run the lights!
    Power consumption is rated under 200 watts which depends on the color choice and intensity. The light pods and the base are fan-cooled. The AC connector will mate with a standard IEC cable or with a special locking cable (sold separately). Line voltage can be anywhere from 100 to 240 volts AC enabling you to use the LP-LED Bars practically anywhere!

  • Battery Status Indicators: The LP-LED2M has a series of four green LEDs to indicate the approximate charge level. The upper green LED is illuminated if there is greater than 90% charge in the battery. The red LED only will indicate that the battery is critically low (less than 10% remaining) and needs immediate charging.

    • The indicators will be engaged only when the power switch is turned on.
  • Charging Indicator: Whenever AC is connected to the unit, the charging indicator will be turned on. If it is green, the unit is fully charged. If it is red, the unit is in the process of charging.

  • Charging the LP-LED2M: To charge the LP-LED2M, plug it into an AC power source using the included power cord. The charging indicator LED is the best indication of the charging status; even if all of the battery status LEDs are lit, there is still possibly some additional charging time required. The LP-LED2M can be safely left connected to AC power for charging indefinitely. It will intelligently control its own charging regime when plugged in long-term.

    • Note: The battery charge rate will drop to 1/8th when the unit is between the temperatures of 0°C-10°C
      (32°F-50°F), and also 35°C-45°C (95°C-113°C). Charging will be suspended when the unit is below 0°C (32°F) or above 45°C (113°F).
      If the LP-LED2M is going to be stored unused for a long period of time (greater than 6 months) it is advisable to periodically plug it in to charge up the battery.

    • If the LP-LED2M has been stored for a long period of time unused and has not been maintained, it is advisable to connect the charger and leave it plugged in for approximately 24 hours.

  • Yorkville sound LP-C12 and LP-C4 Controllers: The LP series controllers provide an easy way to control LP-series lights. The LP-C4 is a simple controller intended for foot-controlled applications and small applications. The LP-C12 provides extensive effects, effects patches, and scene controls in an especially easy-to-use format. The use of LP-series controllers also is the easiest way to synchronize effects between bars. The LP-C12 patch allows some pods to be under scene control while other pods are running effects.

  • Yorkville Sound LP-608 Lighting Controller: When operating with the Yorkville Sound LP-608 lighting controllers the color controls on the LP-LED Bars remain active. The Color control can be used to select the color of each pod or if the Color control is set to off then the LP-Controller’s intensity control becomes the color control (including off) but the intensity is not controllable.

    • Note: Operation with the legacy LP-608 controller will require a ‘gender reversing’ adapter in line with the XLR cable. This was done to prevent an accidental connection to a DMX™ controller from possibly causing damage.

Audio In

Yorkville -LP-LED2M -Battery-Powered-Stage-Lighting-Lightbar-
FIG-2

Hook Up with Controller

Yorkville -LP-LED2M -Battery-Powered-Stage-
Lighting-Lightbar-FIG-3

DMX™ Modes for the LP-LED Bars

Set unit to the off position in order to access DMX. Specific operating instructions for the DMX™ modes are available in the specific DMX™ controller operation manual. For specific LP-LED Bar DMX™ modes see the addendum at the end of the manual.

Mode 1 (4 DMX™ channels, ALL Dip switches OFF)

  • CH 1 – Intensity of Pod 1
  • CH 2 – Intensity of Pod 2
  • CH 3 – Intensity of Pod 3
  • CH 4 – Intensity of Pod 4

Note: The user must change the color on the Light Bar itself, and will not have control of it in this mode. Additionally, if the user needs MAXIMUM INTENSITY, the Brightness MUST be set to MAXIMUM on the Lightbar itself

Mode 2 (8 DMX™ Channels, dip switch #10 set to ON)

  • CH 1 – Intensity of Pod 1
  • CH 2 – Colour for Pod 1
  • CH 3 – Intensity of Pod 2
  • CH 4 – Colour of Pod 2
  • CH 5 – Intensity of Pod 3
  • CH 6 – Colour of Pod 3
  • CH 7 – Intensity of Pod 4
  • CH 8 – Colour of Pod 4

Mode 3 (20 DMX™ Channels, dip switch #11 set to ON)

  • CH 1 – Red for Pod 1
  • CH 2 – Green for Pod 1
  • CH 3 – Blue for Pod 1
  • CH 4 – White for Pod 1
  • CH 5 – Intensity for Pod 1
  • CH 6 – Red for Pod 2
  • CH 7 – Green for Pod 2
  • CH 8 – Blue for Pod 2
  • CH 9 – White for Pod 2
  • CH 10 – Intensity for Pod 2
  • CH 11 – Red for Pod 3
  • CH 12 – Green for Pod 3
  • CH 13 – Blue for Pod 3
  • CH 14 – White for Pod 3
  • CH 15 – Intensity for Pod 3
  • CH 16 – Red for Pod 4
  • CH 17 – Green for Pod 4
  • CH 18 – Blue for Pod 4
  • CH 19 – White for Pod 4
  • CH 20 – Intensity for Pod 4

Mode 4 (32 DMX™ Channels, dip Switch #10 and #11 set to ON)

  • CH 1 – Red for Pod 1
  • CH 2 – Green for Pod 1
  • CH 3 – Blue for Pod 1
  • CH 4 – White for Pod 1
  • CH 5 – Intensity for Pod 1
  • CH 6 – Strobe Speed for Pod 1
  • CH 7 – Strobe Intensity/Brightness for Pod 1 CH 8 – Sync (Master)
  • CH 9 – Red for Pod 2
  • CH 10 – Green for Pod 2
  • CH 11 – Blue for Pod 2
  • CH 12 – White for Pod 2
  • CH 13 – Intensity for Pod 2
  • CH 14 – Strobe Speed for Pod 2
  • CH 15 – Strobe Intensity/Brightness for Pod 2 CH 16 – Sync to Master CH 8
  • CH 17 – Red for Pod 3
  • CH 18 – Green for Pod 3
  • CH 19 – Blue for Pod 3
  • CH 20 – White for Pod 3
  • CH 21 – Intensity for Pod 3
  • CH 22 – Strobe Speed for Pod 3
  • CH 23 – Strobe Intensity/Brightness for Pod 3 CH 24 – Sync to Master CH 8
  • CH 25 – Red for Pod 4
  • CH 26 – Green for Pod 4
  • CH 27 – Blue for Pod 4
  • CH 28 – White for Pod 4
  • CH 29 – Intensity for Pod 4
  • CH 30 – Strobe Speed for Pod 4
  • CH 31 – Strobe Intensity / Brightness for Pod 4 CH 32 – Sync to Master CH 8

Mode 5 (Occupies 16 DMX Channels. Dip Switch 12 Up from the Right Only)

  • CH 1 – Chase Effect
  • CH 2 – Colour Fade Effect
  • CH 3 – Mixed Colour Fade Effect
  • CH 4 – Audio Modulated Sound Active (3 Band Slow or 4 Band Fast) CH 5 – Flash All Sound Active
  • CH 6 – Flash Pairs Sound Active
  • CH 7 – Audio Chase Sound Active

Battery Powered Stage Lighting

  • CH 8 – Audio Modulated Sound Active (3 Band Slow or 4 Band Fast) CH 9 – Intensity of Pod 1
  • CH 10 – Colour of Pod 1
  • CH 11 – Intensity of Pod 2
  • CH 12 – Colour of Pod 2
  • CH 13 – Intensity of Pod 3
  • CH 14 – Colour of Pod 3
  • CH 15 – Intensity of Pod 4
  • CH 16 – Colour of Pod 4

LP-LED Overhead Truss Mounting Instructions

Yorkville -LP-LED2M
-Battery-Powered-Stage-Lighting-Lightbar-FIG-12

The safety cable must have a ‘Working Load Limit’ in excess of 150 lb/f. A 3/32 inch stainless steel safety cable will meet this requirement

NOTE: A lock washer MUST be used on each bolt

  • ALWAYS mount the light to a secure approved truss with sufficient load-bearing capability to ensure a safe installation.
  • ALWAYS perform periodic safety inspections to ensure the installation is safe and secure.
  • ALWAYS ensure C-clamps are fully tightened with a thread-locker and properly orient the C-clamp for maximum security.
  • ALWAYS use a steel safety cable as a secondary safeguard to protect people and property in case the primary mounting mechanism fails.

Yorkville -LP-LED2M -Battery-Powered-Stage-Lighting-Lightbar-
FIG-13Yorkville -LP-LED2M -Battery-Powered-Stage-Lighting-Lightbar-
FIG-19

  1. Fully extend the tripod legs for maximum stability.
  2. Position the LP-LED unit/s at de-sired positions on poles and use thumbscrews and locking pins to help secure the position.
  3. Extend the Speaker Tripod pole to the desired height and use the locking pin and the thumbscrews to help secure the position.

IMPORTANT: ALWAYS use the speaker stand on a flat, level surface to ensure stability. The speaker stand must have sufficient load capacity

LP-LED2M Convenience Power Receptacle

  • The LP-LED2M provides a convenient outlet that can minimize wiring and improve overall safety when used properly. Please carefully read all of the important safety tips shown below for the long and safe use of your lighting equipment.

IMPORTANT

  1. Do not overload the convenience outlet. Make sure power drawn from the first outlet does not exceed the limits shown on the chassis. Some acceptable combinations are shown below.Yorkville -LP-LED2M -Battery-Powered-Stage-Lighting-Lightbar-FIG-17
  2. Always inspect the cords and plugs before use. Do not use outlets or cords that have exposed wiring, are worn or damaged. Replace electrical cords that have worn or damaged insulation and remember to pull the plug, not the cord to extend the life of the cord itself.
  3. The main plug of the power supply cord shall remain readily operable. It is important that the user can quickly get to the ac plug and disconnect the unit in the case of an emergency.
  4. The AC supply cord should be routed so that it is unlikely that it will be damaged. Protect the power cord from being walked on or pinched. If the AC supply cord is damaged DO NOT OPERATE THE UNIT. To completely disconnect this apparatus from the AC Mains, disconnect the power supply cord plug from the AC receptacle. Unplug this apparatus during lightning storms or when unused for long periods of time. Route cords away from traffic to avoid tripping hazards and unnecessary wear on the power cord.
  5. Never Break Off the Third Prong on a Plug. Replace broken 3-prong plugs and make sure the third prong is properly grounded.
  6. Keep line cords away from heat, water, and oil. They can damage the insulation and create a shock hazard.
  7. Do not tie cords in tight knots. Knots can cause short circuits and shocks. Loop the cords or use a twist lock plug.
  8. Be aware that unusually warm or hot outlets or cords may be a sign that an unsafe wiring condition exists. Check to ensure there are not too many devices in the chain drawing too much current from the line cord. Unplug any cords or extension cords from these outlets and do not use them until a qualified electrician has checked the wiring.

Specifications

  • Max AC Input Voltage 100-240VAC 50/60 Hz
  • Power Consumption LEDs 14 watts per LED (4 LEDs, 56 watts per pod)
  • Power Consumption 200VA, 1.7A @ 120VAC Nominal
  • Stand Mount Size 1 3/8 inch Round
  • Controller Cable Yorkville: Standard Shielded 3-pin XLR Cable
  • Other DMX: Standard Shielded 3-pin XLR Cable
  • Dimensions (LWH) 27 x 4.8 x 11.1 inches (68.6 x 12.25 x 28.2 cm)
  • Weight 22.5 lbs (10.2 kg)

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Unlimited Warranty

Yorkville’s two and ten-year unlimited warranty on this product is transferable and does not require registration with Yorkville Sound or your dealer. If this product should fail for any reason within two years of the original purchase date (ten years for the wooden enclosure), simply return it to your Yorkville dealer with the original proof of purchase and it will be repaired free of charge. This includes all Yorkville products, except for the YSM Series studio monitors, Coliseum Mini-Series, and TX Series Loudspeakers.
Freight charges, consequential damages, weather damage, damage as a result of improper installation, and damages due to exposure to extreme humidity, accident, or natural disaster are excluded under the terms of this warranty. The warranty does not cover consumables such as vacuum tubes or par bulbs. See your Yorkville dealer for more details. Warranty valid only in Canada and the United States.