milwaukee M18 DFC 18V RedLithium Dual Charger Instruction Manual
- June 5, 2024
- Milwaukee
Table of Contents
Nothing but HEAVY DUTY
M18 DFC
Original instructions
Picture section
with operating description and functional description
Text section with Technical Data, important Safety and Working Hints and
description of Symbols
TECHNICAL DATA
BATTERY CHARGER
M18 DFC
Voltage range ……………………………… 220-240 V
Quick charge current ………………… 6 A
Maintaining charge current …………………………. 0,5 A
Weight according to EPTA-Procedure 01/2014 ……………… ≤1757 g
Recommended ambient charging temperature ………….. +5…+40 °C
**WARNING** Read all safety warnings, instructions, illustrations and
specifi cations provided with this power tool. Failure to follow all
instructions listed below may result in electric shock, fi re and/or serious
injury. Save all warnings and instructions for future reference.
SAFETY INSTRUCTIONS
Do not dispose of used battery packs in the household refuse or by burning
them. Milwaukee Distributors off er to retrieve old batteries to protect our
environment.
Only the following battery packs can be charged with this charger:
Battery Cat.
No.
M18B
M18BX
M18B2
M18B4
M18B5
M18B6
M18B9
M18HB3
M18HB4
M18HB5.5
M18HB8
M18HB12| Cell Type
Li-Ion
Li-Ion
Li-Ion
Li-Ion
Li-Ion
Li-Ion
Li-Ion
Li-Ion
Li-Ion
Li-Ion
Li-Ion
Li-Ion| DC Volts
18 V
18 V
18 V
18 V
18 V
18 V
18 V
18 V
18 V
18 V
18 V
18 V| Capacity
≤ 1.5 Ah
≤ 3.0 Ah
≤ 2.0 Ah
≤ 4.0 Ah
≤ 5.0 Ah
≤ 6.0 Ah
≤ 9.0 Ah
≤ 3.0 Ah
≤ 4.0 Ah
≤ 5.5 Ah
≤ 8.0 Ah
≤ 12.0 Ah| Cell No.
5
2 x 5
5
2 x 5
2 x 5
2 x 5
3 x 5
5
5
2 x 5
2 x 5
3 x 5
---|---|---|---|---
Do not try to charge non-rechargeable batteries with this charger.
Do not store the battery pack together with metal objects (short circuit
risk). No metal parts must be allowed to enter the battery section of the
charger (short circuit risk).
Never break open battery packs or chargers and store only in dry rooms. Keep
dry at all times. The battery clamps of the charger are fed by the main
supply. Do not touch the tool with conducting objects. Never charge a damaged
battery pack. Replace with a new one. Before use check the machine, cable, and
plug for any damages or material fatigue. Repairs should only be carried out
by authorized Service Agents.
This appliance is not intended to be used or cleaned by persons with reduced
physical, sensory or mental capabilities, or lack of experience or knowledge
unless they have been given instructions concerning the safe use of the
appliance by a person legally responsible for their safety. They should be
supervised whilst using the appliance. Children shall not use, clean, or play
with this appliance, which when not in use should be secured out of their
reach.
Warning! To reduce the risk of fi re, personal injury, and product damage
due to a short circuit, never immerse your tool, battery pack, or charger in fl
uid or allow a fl uid to fl ow inside them. Corrosive or conductive fl aids, such
as seawater, certain industrial chemicals, and
bleach or bleach-containing products, etc., can cause a short circuit.
SPECIFIED CONDITIONS OF USE
This charger charges 18V Milwaukee Li-Ion battery packs. This charger can charge two battery packs at the same time. Do not use this product in any other way as stated for normal use.
MAINS CONNECTION
Connect only to single-phase AC current and only to the system voltage indicated on the rating plate. It is also possible to connect to sockets without an earthing contact as the design conforms to safety class II.
CHARGING TIME
Battery Cat. No.
M18B
M18B2
M18BX
M18B4
M18B5
M18B6
M18B9
M18HB3
M18HB4
M18HB5.5
M18HB8
M18HB12| Volts
18 V
18 V
18 V
18 V
18 V
18 V
18 V
18 V
18 V
18 V
18 V
18 V| Capacity
≤ 1.5 Ah
≤ 2.0 Ah
≤ 3.0 Ah
≤ 4.0 Ah
≤ 5.0 Ah
≤ 6.0 Ah
≤ 9.0 Ah
≤ 3.0 Ah
≤ 4.0 Ah
≤ 5.5 Ah
≤ 8.0 Ah
≤ 12.0 Ah| Charging Time
approx.
21 min
27 min
35 min
48 min
63 min
73 min
101 min
≤ 35 min
≤ 35 min
≤ 60 min
85 min
128 min
---|---|---|---
LI-ION BATTERIES
The rechargeable batteries are partially charged. The LED on the battery indicates the state of charge. If it is not used for long periods, the rechargeable battery will switch to a non-operative state. When fully discharged the rechargeable battery switches off automatically (depth discharge not possible). Under extreme circumstances, the internal temperature of the battery could become too high. If this happens, the battery will shut down. Place the battery on the charger to charge and reset it. The state of charge can be read by pressing the button on the rechargeable battery. The battery can be left in the electric tool while the reading is taken but it must be switched off at least one minute beforehand (otherwise the display will be inaccurate). The number of LEDs illuminated indicates the state of charge. A fl ashing LED indicates a max. power reserve of 10%. As a general principle, if the electric tool should fail to work after inserting the rechargeable battery, then the battery should be plugged into the charger. The displays on the battery and charger will then provide information about the condition of the battery. In low temperatures work may continue at reduced output.
CHARACTERISTICS
After inserting the battery into the reception of the charger the battery will
automatically be charged (the red control lamp is illuminated continuously)
When a hot or cold battery pack is inserted into the charger (fl ashing red
lamp), charging will begin automatically once the battery reaches the correct
charging temperature (+5°C…+40°C). The max. charging current is fl owing when
the temperature of the Li Ion battery is between +5°C and +40°C. The battery’s
charging time is between 1 min and 20 min (at 1,5 Ah),
depending on the state of discharge. Once the battery is fully charged, the
LED on the charger changes from red to green. Remove the battery pack from the
tool for charging when convenient for you and your job. Milwaukee batteries do
not develop a memory when charged after only a partial discharge. It is not
necessary to run down the battery pack before placing it on the charger. As a
general practice, it is best to unplug battery chargers and remove batteries
when not in use. No battery pack damage will occur, however, if the charger
and battery pack are left plugged in. If both LEDs fl ash alternately then the
rechargeable battery is either not fully pushed in or there is a fault with
the battery or charger. Take the charger and battery out of use immediately
for safety reasons and have them inspected by a Milwaukee customer service
center. This charger can charge two battery packs at the same time.
LIGHT INDICATORS
| Continuous red| Charging
---|---|---
| Slow fl ashing green| Approaching full charge
| Continuous green| Charging is complete
| Fast fl ashing red| The battery is too hot/cold – Charging will begin when
the battery reaches the correct charging temperature
| Flashing red/green| Damaged or faulty battery pack
TRANSPORTING LITHIUM BATTERIES
Lithium-ion batteries are subject to the Dangerous Goods Legislation
requirements.
Transportation of those batteries has to be done in accordance with local,
national, and international provisions and regulations.
-
The user can transport the batteries by road without further requirements.
-
Commercial transport of Lithium-Ion batteries by third parties is subject to Dangerous Goods regulations. Transport preparation and transport are exclusive to be carried out by appropriately trained persons and the process has to be accompanied by corresponding experts.
When transporting batteries: -
Ensure that battery contact terminals are protected and insulated to prevent short circuits.
-
Ensure that the battery pack is secured against movement within the packaging.
-
Do not transport batteries that are cracked or leak. Check with the forwarding company for further advice
MAINTENANCE
If the supply cord of this appliance is damaged, it must only be replaced by a
repair shop appointed by the manufacturer, because special purpose tools are
required
Use only Milwaukee accessories and Milwaukee spare parts. Should components
need to be replaced which have not been described, please contact one of our
Milwaukee service agents (see our list of guarantee/service addresses). If
needed, an exploded view of the tool can be ordered. Please state Article No.
as well as the machine type printed on the label and order the drawing at your
local service agents or directly at: Techtronic Industries GmbH, Max-Eyth-
Straße 10, 71364 Winnenden, Germany.
SYMBOLS
| Please read the instructions carefully before starting the
machine.
---|---
| Do not burn used battery packs.
| Never charge a damaged battery pack. Replace it with a new one.
| Do not dispose of electric tools, batteries/or rechargeable batteries
together with household waste material. Electric tools and batteries that have
reached the end of their life must be collected separately and returned to an
environmentally compatible recycling facility. Check with your local authority
or retailer for recycling advice and collection point.
| This tool is only suitable for indoor use. Never expose tool to rain.
| Time-lag fuse 5 A
| Double isolated
| European Conformity Mark
| British Confomity Mark
| Ukraine Conformity Mark
| EurAsian Conformity Mark
Copyright 2020
Techtronic Industries GmbH
Max-Eyth-Str. 10
71364 Winnenden
Germany
+49 (0) 7195-12-0
www.milwaukeetool.eu
Techtronic Industries (UK) Ltd
Fieldhouse Lane
Marlow Bucks SL7 1HZ
UK (01.21)
4931 4703 44
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>