Sealey 9001 A1 Filter Cartridge Pack of 2 Instruction Manual

September 28, 2024
SEALEY

Sealey 9001 A1 Filter Cartridge Pack of 2

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble-free performance.

REFER TO INSTRUCTIONS

IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

INTRODUCTION

A1 Filter provides protection against inorganic vapour with a boiling point higher than 65°C. Suitable for use with the Sealey 9000 half-face mask. Conforms to EN 14387:2004. Provides protection against inorganic vapor.

  • Type Examination Ref.: 0082/1694/079/12/21/0781
  • Notified Body : Apave Sudeurope sas (notified body number 0082)

SAFETY

IMPORTANT: The use limitations of these respirators depend on the type of filter they are used with as well as the conditions of the environment user works in, contaminant concentration, type of work, etc. For an effective and proper use of the filters, read car efully the following instructions and keep this document for further consultation.

  • These filters DO NOT supply oxygen (O2).
  • Use in adequately ventilated areas. DO NOT use in case of oxygen deficiency.
  • DO NOT use in explosive atmospheres.
  • Filters should NOT be used in fire-fighting or to work with open flames or molten metal since the combustion of the activated carbon contained in the filters can generate high levels of toxic substances.
  • The right filter must be chosen according to concentration and type of contaminant in each case.
  • DO NOT use as protection against carbon monoxide under any circumstances.
  • DO NOT modify or repair the filter or cover. In case of damage or loss of seal, replace the product with a new one.
  • Filters, combined filters and absorbers require no maintenance or repair.
  • Leave work if respiratory protection is damaged, if you have difficulty breathing and/or if you start to feel nauseous or dizzy.
  • DO NOT use respirators with filters or combined filters or absorbers in closed silos, wells, canals or other closed places without ventilation.
  • DO NOT use in an oxygen enriched atmosphere.
  • DO NOT use in an atmosphere with unknown air quality.
  • Use cleansers also as indicated in the respirator manual
  • DO NOT use if the storage took place under conditions other than those specified by the manufacturer. This may affect the shelf life.
  • DO NOT remove the adapter once installed during use.
  • Ensure the type of filter is the correct one for intended use, and that you have installed both filters of the same type.
  • Inspect the filters and respirator for any signs of damage before each use. If damaged or the item has expired it must be replac ed.
  • Only use filters that have been stored correctly in their original packaging as per these instructions. The use of filters must comply with current legislation, regulations about respiratory protection and regulations from various official bodies.

ASSEMBLY

BEFORE EACH USE

  1. Read instruction for use carefully. 2. Make sure the type of filter is the correct one for intende d use. 3. Make sure that you installed both filters of the same type. 4. Make sure that the filter as we ll as the respirator do not present any signs of tearing, disto rtions, dents, nor dirt Should this be the case, it must be disposed of. 5. Ma ke sure filter is in its original packaging. 6. Filter must be i nspected before its use. In case of contamination, distortion and/or expiration it must be replaced.

FITTING THE FILTERS
Match the plastic filter connection with the filter holder on the mask. Press and turn the filter all the way clockwise. Repeat with second filter.

PRE-FILTER
An additional pre-filter can be fitted if required. (Not supplied) Assembly of 9006 (pre-filter) and 9009 (cover). Place the 9006 pre-filter onto the 9001 filter with the printed side facing in. Place the 9009 cover on the filter and press together. Verify that the pre-filter covers the 9001 filter. Reverse the procedure to disassemble the product.

FILTER PROTECTION

MODEL STANDARD/TYPE/CLASS PROTECTION
9001 EN 14387:2004 + A1:2008 / A1 Organic gases and vapours of organic

substances with boiling point > 65°C
MARKS| MEANING
---|---
A| Filter against organic gases and vapors with a

boiling point > 65⁰C

AX| Filter against organic gases and vapours with a boiling point < 65⁰C
B| Filter against inorganic gases and vapors excluding carbon monoxide
E| Filter against sulfur dioxide and other acid gases
K| Filter against ammonia and organic vapours derived from ammonia
P| Filter against particulate (dust and aerosols)
R| Filter reusable
NR| Filter nonreusable
D| Filter passes the optional Dolomite clogging test
CLASS| GAS FILTERS| PARTICULATE FILTERS
---|---|---
1| Gas concentration 1000 ppm (0.1%)| Penetration 20%
2| Gas concentration 5000 ppm (0.5%)| Penetration 6%
3| Gas concentration 10000 ppm (1%)| Penetration 0.05%

SYMBOLS

STORAGE

Storage in conditions other than those specified by the manufacturer may affect shelf life. Keep in original hermetic packing for storage and/or transport. Store in a cool, dry environment away from contaminants. Avoid high levels of relative humidity >80%. DO NOT expose to heat or direct sunlight. Store the respirator without filters in the hermetically sealed bag supplied at room temperature, in a dry place away from contaminants. DO NOT expose the respirator to the heat temperature marked on the packaging. The ambient temperature in which the products can be used is shown on the packaging and on the product by the pictogram.

CLEANING & DISINFECTION

In case of damage or deterioration, replace the filter. DO NOT clean or maintain. The replacement of the filters must be determined through the implementation of a respiratory protection program which ensures that they are replaced before the end of their service life.

OBSOLESCENCE

Filters, combined filters, absorbers, and covers have the production date on the packaging and on the product. The use-by date is 5 years from the production date, which is valid when stored in the original packaging by the manufacturer’s recommendations.

FILTER DISPOSAL

Once filters have been used, they must be disposed of according to the current national legislation. This document has been drawn up according to Regulation (EU) 2016/425 as amended to apply to GB for Personal Protective Equipment. The declaration of conformity can be accessed at www.sealey.co.uk.

ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories, and packaging should be sorted, taken to a recycling center, and disposed of in a manner that is compatible with the environment. When the product becomes completely unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids according to local regulations.

  • Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications, and parts without prior notice.
  • Important: No Liability is accepted for incorrect use of this product.
  • Warranty: The guarantee is 12 months from the purchase date, proof of which is required for any claim.

EU | Sealey EU Ltd, Farney Street, Carrickmacross, Co. Monaghan, A81 PK68 Ireland UK | Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR 01284 757500 sales@sealey.co.uk www.sealey.co.uk