GE Personal Security Window and Door Alarm, 4 Pack, DIY Protection, Burglar Alert, Wireless, Chime/Alarm, Easy Installation-Complete Features/Instruction Manual
- June 5, 2024
- GE
Table of Contents
- GE Personal Security Window and Door Alarm, 4 Pack, DIY Protection,
- Specifications
- Introduction
- GAP BETWEEN ALARM AND MAGNETIC SENSOR
- BATTERY TEST AND INSTALLATION
- INSTALLATION
- OPERATION
- CARE AND MAINTENANCE
- WARNING
- 90 DAY LIMITED WARRANTY
- Caution
- FREQUENTLY ASKED QUESTIONS
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
GE Personal Security Window and Door Alarm, 4 Pack, DIY Protection,
Burglar Alert, Wireless, Chime/Alarm, Easy Installation
Specifications
- DIMENSIONS :.72 x 1.63 x 2.41 inches
- WEIGHT : 6.4 ounces
- ALARM SOUND: 120 dB
- BRAND: GE
Introduction
The GE Personal Security window and door alarm come with 4 alarms that can be used for doors or windows. Each of the alarms comes with 3 adjustable settings which are off, chime and alarm. They feature an alarm with a sound level of 120dB. This helps to alert you in case of an intruder. It doesn’t require any wiring or any hardware installation. These alarms are designed to be used for indoors only. It also features a built-in low battery test button which can be used to check the battery level. The alarms are powered by LR44 batteries each.
GAP BETWEEN ALARM AND MAGNETIC SENSOR
(Alsmi is activated when switched ON and gap between alarm and the magnetic sensor is greater than 0.5″).
BATTERY TEST AND INSTALLATION
The Magnetic Window Alarm requires (4) L044 button batteries (included). Average battery life for typical usage is 1 year.
- Slide cover off the battery compartment located on the front of the main unit.
- Push the ‘Battery Test’ pushbutton in the battery compartment. If the green light illuminates, the battery is still good. If it fails to illuminate, replace all batteries.
- Insert (4) LR44 button batteries noting polarity.
- Replace battery compartment cover.
IMPORTANT: Remove batteries before storing the Alarm for extended periods. Batteries corrode over time and may cause permanent damage to the unit. Different types of batteries or new and used batteries should not be mixed. Depleted batteries should be removed from the unit and disposed of properly.
INSTALLATION
Using the double-sided adhesive tape provided, mount the alarm and magnetic sensor on window, door, or cabinet to be protected, placing one of the units on the part of the fixture that opens (window) and the other unit on the stationary part of the fixture (frame). Mount so that when the window, door or cabinet is closed, the gap between the alarm and sensor is no more than 0.5″ (preferably less).
OPERATION
- To arm the unit, slide the cover off the battery compartment located on the front of the main unit. Toggle ON/OFF switch to the ON position. The window on the housing will become red. Replace the battery compartment cover. Whenever the protected window, door or cabinet is opened (causing the alarm to be separated from the magnetic sensor by more than 0.5″), the alarm siren will sound continuous until disarmed.
- To disarm the unit, slide the cover off the battery compartment. Toggle ON/OFF switch to OFF position. Make sure the window, door or cabinet is closed before rearming.
NOTE: To test, a cloth can be used to cover the alarm to reduce risk of hearing damage.
CARE AND MAINTENANCE
To clean the unit housing, use a soft cloth slightly dampened with water and wipe dry. Do not use chemical agents as this may damage and discolor the unit.
WARNING
Limitations of Alarm Products
This product should be tested weekly to make sure it is working properly. The product, if used properly, may reduce the risk of burglary, robbery, fire, or other adverse events. However, JASCO is not an insurer, this product is neither insurance nor a guarantee that such an event will be prevented, and users should protect themselves with proper insurance. JASCO makes no representation that this product cannot be compromised or circumvented, that it will provide an adequate warning, or that it will prevent any personal injuries, property damage, or other losses. Like any alarm product, including expensive commercial systems, it may be bypassed, it is subject to compromise, and it may fail to warn for a variety of reasons, including, but not limited to: improper installation or positioning; improper maintenance: tampering; dead or improperly installed batteries: sensing limitations; component failures; smoke may not reach detectors; for wireless systems, the functional range may be adversely affected by certain environmental conditions, radio frequency interference and obstructions between the transmitters and receivers; for systems using telephone lines, the lines may be out of service or disrupted; for infrared products, intrusions may be outside of a product’s designed range and certain environmental conditions may impact performance and audible alarm signals may be outside of hearing range, muted by doors, walls, and floors, unheard by deep sleepers or the hearing-impaired, or overwhelmed by other sounds.
90 DAY LIMITED WARRANTY
Jasco Products Company warrants this product to be free from manufacturing defects for a period of ninety days from the original date of consumer purchase. This warranty is limited to therepair or replacement of this product only and does not extend to consequential or incidental damage to other products that may be used with this unit This warranty is in lieu of all other warranties express or implied. Some states do not allow limitations on how long an implied warranty lasts or permit the exclusion or limitation of incidental or consequential damages, so the above limitations may not apply to you. This warranty gives you specific rights, and you may also have other rights which vary from state to state. If unit should prove defective within the warranty period, return prepaid with dated proof of purchase to:
Jasco Products Company 311 N.W. 122nd Oklahoma City, OK. 73114
Caution
Batteries may leak harmful liquids or ignable materials or explode causing injury and product damage
- Do not mix old and new or other battery types
- Replace all oatteriesatthe same time
- Replace fully discharged batteries immediately
FREQUENTLY ASKED QUESTIONS
-
When these alarms are set in chime mode, is it just the initial chime when opened, or does it chime continuously?
It has a double chime when opened. In alarm mode, it gives a continuous siren until turned off. -
Do this work with recessed doors or windows?
No, it doesn’t work with recessed doors or windows. -
Is this just one alarm?
Yes, the device is two pieces but consists of only one alarm. -
Does this alarm give you time to exit before it enters ready mode?
No, it doesn’t. -
Is this UL approved? Does it say it on the package or on the sticker behind it?
The alarms are operated by batteries and aren’t UL listed. -
Do they sound each time the window or door is opened?
Yes, they sound each time the window or door is opened or closed. -
How loud is the chime?
The chime is pretty loud alerting you finely. -
How do these work on a curved door frame, since the two connections won’t be flush with one another?
It can be secured on the curved door frame using double sided tape. -
Do they have a low battery indicator?
Yes, the alarms have an indicator light which indicates when the battery is low. -
Can these be used a car door?
Yes, it can be used on a car door.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>