exqUISIT CM 30752 we Mobil Air-Condition Instruction Manual
- June 5, 2024
- EXQUISIT
Table of Contents
- exqUISIT CM 30752 we Mobil Air-Condition
- Getting to know your appliance Scope of supply/accessories
- Description of control panel / remote control
- Description of the LED display
- Your safety
- Unpacking and setting up the appliance
- Installation
- Before using for the first time
- Operation
- Cleaning
- Troubleshooting
- Technical data
- Disposal of old appliances
- General warranty terms
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
exqUISIT CM 30752 we Mobil Air-Condition
Intended use
The mobile air conditioner is designed exclusively for conditioning,
ventilating and dehumidifying the air in closed rooms. It is intended
exclusively for use in private households and is not suitable for commercial
use.
Use the mobile air conditioner only as described in these operating
instructions. Any other form of use does not constitute an intended use and
can result in material damage or even personal injury. The mobile air
conditioner is not a toy. The manufacturer or dealer accepts no liability for
damage or injury resulting from improper use or use for other than the
intended purpose.
Getting to know your appliance Scope of supply/accessories
- Rear panel
- Control panel
- Front panel
- Air outlet incl. air outlet grille
- Transport rollers
- Mains plug
- Filter holder
- Filter
Description of control panel / remote control
- a LED Cool, Dehum, Fan
- b Activate/deactivate timer c Setting the fan speeds
- d Set mode (cooling, dehumidifying, fan)
- e Signal receiver
- f High temperature
- g Low temperature
- h Switch appliance ON/OFF
Description of the LED display
LED DISPLAY | FUNCTION |
---|---|
W.F. | Water tank full |
DEHUM | Dehumidification mode |
FAN | Ventilation mode |
COOL | Cooling mode |
HIGH | High fan speed |
LOW | Low fan speed |
Push the exhaust air hose into the appliance from above (see red arrow).
Your safety
Safety and responsibility
Safety of children and persons with limited capabilities This appliance can be
used by children above 8 years of age, and by persons with limited physical,
sensory or mental aptitude or lack of experience and knowledge if they are
supervised or have been instructed in the safe use of the appliance and
understand the associated hazards. Children must not be allowed to play with
the appliance. Cleaning and servicing by the user must not be carried out by
children without supervision. Children must be able to operate the mobile air
conditioner correctly and understand the risks highlighted in these operating
instructions. Children must be supervised when the mobile air conditioner is
in operation to ensure that they do not play with the appliance.
Safety and warnings
- Never operate several appliances from the same plug socket, e.g. using a multiple socket strip.
- Connect the mobile air conditioner only to an easily accessible plug socket in order to be able to disconnect the mains power cable from the mains power supply in the event of a fault.
- If you connect the mobile air conditioner to the mains power supply using an extension lead, the extension lead must satisfy the applicable safety regulations.
- Do not operate the mobile air conditioner if it shows visible signs of damage or the mains power cable or mains plug is defective.
- Pull the mains plug out of the plug socket immediately if the mobile air conditioner:
- Develops unusual noises, odours or smoke.
RISK OF EXPLOSION AND POISONING!
Do not operate, store or transport the mobile air conditioner in poorly
ventilated rooms.
CAUTION
RISK OF INJURY!
Improper use of the mobile air conditioner can lead to a risk of injury.
- Ensure that the air conditioner cannot catch any loose objects, e.g.
- Blinds and curtains,
- Long hair,
- Neck ties, etc.
There is a risk of the air current drawing in such objects.
ATTEBTION
APPLIANCE DAMAGE!
Improper use of the mobile air conditioner can result in damage to the
appliance.
Unpacking and setting up the appliance
Take care when opening the packaging.
- Remove the mobile air conditioner from the packaging.
- Check that the delivery is complete.
- Check the mobile air conditioner and all the individual parts for damage.
In the event of damage, please contact After Sales Service www.domest.nl
RISK OF DAMAGE!
Do not use sharp knives or other pointed objects to open the packaging. This
could result in damage to the mobile air conditioner. Setting up the appliance
FLAMMABLE SUBSTANCES!
The appliance may only be installed, operated and stored in rooms with a
minimum area of 4 m².
Observe the minimum clearances when installing the mobile air conditioner.
- Above: 50 cm
- To the sides: 30 cm
- Distance to wall: 30 cm
Operate the mobile air conditioner only at the following ambient temperatures:
OPERATING MODE | °C |
---|
COOL
Cooling mode
| 17°C – 35°C
DEHUM
Dehumidification mode
| 16°C – 35°C
- Install the mobile air conditioner:
- In an easily accessible location,
- On a level, dry and sufficiently stable surface.
- Do not place the mobile air conditioner on the edge of a surface.
- Never completely close the ventilation flap during operation.
- Never cover the ventilation openings on the top and back of the mobile air conditioner.
- Never place the mobile air conditioner on or near hot surfaces (e.g. cooker hotplates, etc.).
- Do not allow the mains power cable to come into contact with hot parts.
- Never expose the mobile air conditioner to high temperatures (radiators, etc.) or the weather (rain, etc.).
- Never pour liquids into the mobile air conditioner.
- Do not use the mobile air conditioner if the plastic components are cracked, split or deformed.
- Have damaged components replaced only by suitable OEM spare parts.
- Always transport, operate and store the mobile air conditioner upright.
Installation
Install the accessories supplied before using the mobile air conditioner.
- First install the appliance connection adapter and the window panel adapter on the exhaust air hose.
- Push the appliance connection adapter into the fitting on the side until it engages.
- Connect the window panel adapter to the window panel (see Fig. 5 / 6).
NOTE
Installation is possible for the following window sizes:
IMPORTANT
- A kinked exhaust air hose will detract from the performance of the mobile air conditioner.
- Do not kink the exhaust air hose.
- Observe the following minimum and maximum heights.
- For the window type Fig. 5, please note that the Hot air stop can be purchased from our service department or via our homepage to seal the top and bottom surfaces
NOTE
The better the windows or openings are sealed, the better the cooling effect
of the mobile air conditioner.
Ventilate the room in which the mobile air conditioner is installed at regular
intervals.
IMPORTANT
Do not extend the exhaust air hose. Do not reduce the diameter of the exhaust
air hose.
Before using for the first time
Basic cleaning
Clean the mobile air conditioner and all individual parts before using for the
first time as described in section “Cleaning” to remove any packaging dust
residues.
Allow the mobile air conditioner to stand upright for 12 hours before using
for the first time.
In order to remove any production-related residues, operate the mobile air
conditioner for 1 hour with the window open.
If odors occur during the operation of the mobile air conditioner, this is
normal and disappears after a short time. It is not a malfunction. Ventilate
sufficiently.
Electrical connection
WARNING
RISK OF ELECTRIC SHOCK!
A faulty electrical installation or excessively high mains voltages can result
in electric shocks! Connect the mobile air conditioner only
- to a properly installed plug socket with earthing contact
- when the main power supply of the plug socket corresponds to the data on the type plate.
Operation
The fan of the air conditioner draws in room air and blows the cooled air out again through the refrigeration system. During this process, the moisture in the air condenses and is collected in the internal water tank.
ATTENTION
RISK OF DAMAGE!
Improper handling can result in damage to the mobile air conditioner.
Switching on the mobile air conditioner
- Switch the mobile air conditioner on and off with button “h”.
- The mobile air conditioner starts automatically.
- The preset temperature can be seen on the display (e.g. 22°C).
Setting the room temperature
Set the temperature in °C with buttons “g” and “f” (TEMP+/TEMP-).
Press button “g” or “f” several times to increase or decrease the temperature
in steps of 1°C (max. 35°C and min.16C).
Remote control
Point the remote control at the signal receiver “e” of the mobile air
conditioner.
The maximum distance between the appliance and the remote control is 5 meters.
APPLIANCE DAMAGE!
- Do not drop the remote control.
- Keep away from direct sunlight.
- Do not leave in the vicinity of heat sources.
Replacing the batteries
- Remove the protective cover on the back of the remote control.
- Replace the empty batteries with two new ones.
ATTENTION
RISK OF ENVIRONMENTAL
DAMAGE!
Batteries are harmful to the environment. Dispose of the batteries in
accordance with the applicable statutory regulations.
Timer function
The mobile air conditioner has a timer function that lets you preset the
desired operating time (hours) and a delayed starting time (in hours). At the
end of the set time, the mobile air conditioner switches on or off
automatically.
Activating/deactivating the timer Set the operating time
- With the mobile air conditioner in operation, press button (b).
- Set the desired operating time between 1 and 24 hours with buttons (b) and “F”.
- The set time appears on the display.
Set the starting time
- With the mobile air conditioner in stand-by mode, press button (b).
- Repeat the steps described under: “Set the operating time”
- As soon as the set time has elapsed, the mobile air conditioner switches on or off automatically.
Connecting the water drain hose
Note that the water drain hose connected to the mobile air conditioner must
not run higher than the position of the hose connection on the mobile air
conditioner at any point. Otherwise, condensation may flow back into the
mobile air conditioner and damage the appliance. See Fig. 5
- Disconnect the mobile air conditioner from the mains power supply before installing the water drain hose.
- Remove the water plug on the rear of the appliance from the drain hole.
- Attach the water drain hose to the connection.
- Route the free end of the water drain hose into a suitable drain or container into which the condensation is to drain.
NOTE If the internal water tank is full, the appliance automatically switches to standby, LED “W.F” lights up.
Setting the fan speed
Use the SPEED button (c) to select the fan speed between “HI” and “LOW”.
Description of the operating modes
Use the MODE button (d) to select the mode COOL, DEHUM or FAN:
- COOL: Cooling mode Temperature and fan speed can be set as required.
- FAN: Ventilation mode The compressor does not run. Set fan speed as required.
- DEHUM: Dehumidification mode The mobile air conditioner always runs fully automatically at 2°C below the current room temperature. The fan speed is automatically LOW and cannot be altered.
NOTE Do not place any objects on the mobile air conditioner.
Cleaning
Clean the mobile air conditioner according to use and degree of soiling, but
at least every 4 weeks.
Always allow the mobile air conditioner to cool down completely before
cleaning!
Cleaning the appliance
- Clean the ventilation openings and the filter at regular intervals (approx. every 2 weeks) to prevent the performance of the mobile air conditioner from deteriorating.
- Wipe down the outside of the mobile air conditioner with a dry or slightly damp cloth.
- Then rub the mobile air conditioner completely dry.
- Remove dust and soiling from the ventilation openings using a suitable soft brush.
Cleaning the filter
- Pull out the filter holder.
- Clean the filter holder with a suitable brush or vacuum cleaner.
- Place the foam filter and the filter grille into the filter holder again.
WARNING
RISK OF ELECTRIC SHOCK!
- Never immerse the mobile air conditioner or the remote control in water for cleaning.
- Do not use steam cleaners for cleaning.
ATTENTION
APPLIANCE DAMAGE RESULTING FROM INCORRECT OPERATION!
Improper cleaning can result in damage to the mobile air conditioner.
- Do not use:
- Aggressive cleaning agents
- Brushes with metal or nylon bristles, or
- Sharp, metallic cleaning aids such as knives, hard spatulas, etc.
These can damage the surfaces.
Troubleshooting
FAULT | POSSIBLE CAUSES | MEASURES |
---|---|---|
The mobile air conditioner does not start. | The mains plug is not plugged into | |
the plug socket. | Check whether the mains plug has been plugged incorrectly. |
Display “W.F” lights up (water
tank full).
| Empty the water tank.
The room temperature is lower than the set temperature.| Lower the set
temperature.
The mobile air conditioner is not operating with the expected effectiveness.
Insufficient cooling.
| Doors and/or windows are not properly closed.| Close all doors and windows,
etc. through which warm air may enter.
There are additional heat sources in the room.| Remove the heat sources, if
possible.
The temperature is set too high.| Lower the set temperature.
Air inlet or outlet is blocked.| Remove objects from the air inlet/outlet.
Clean the air filter and air outlet. Observe the minimum clearances.
Air is not blown out.| The air filter or air outlet is blocked.| See above.
Operating noises.| The mobile air conditioner is not standing on a level and
stable surface.| Ensure that the mobile air conditioner is standing on a level
and stable surface.
Air filter or air outlet blocked.| See above.
The appliance makes “flowing”
noises.
| Flowing noise of the refrigerant. No measures are necessary.
FAULT| POSSIBLE CAUSES| MEASURES
---|---|---
Water runs out.| The water drain hose has come loose or is damaged.| Inspect
the water drain hose for damage and check for correct installation; replace or
install correctly, as necessary.
The water drain hose is blocked.| Remove any obstacles and straighten the
water drain hose.
The drain hole not properly closed. The drain plug is damaged.| Check whether
the drain hole is properly closed.
The plug is damaged.
Close the drain hole properly or replace the plug.
Maximum cooling capacity is not achieved.| The ambient temperature is not 35°C and not 40% relative humidity.| The appliance achieves the maximum cooling capacity only with the following parameters:
– Ambient temperature 31°C
– Indoor humidity 40%
Error messages on the display
Display codes | Meaning |
---|---|
In the event of any error codes, | contact After Sales Service: |
Repair
- Have the mobile air conditioner been repaired only by authorized and certified specialist personnel?
- Have a damaged mobile air conditioner mains power cable repaired only by an authorized and qualified electrician to avoid possible risks.
Unauthorized and unqualified repairs and improper or incorrect connections will void all warranty claims.
Technical data
MODEL | CM 30752 WE / CM 40753 BL |
---|---|
Article No. | 5050091 |
EAN | 4016572103014 / 8717202123117 |
Electrical connection (voltage – frequency) | 220-240 V~50 Hz |
Rated power | 785 W |
Protection class | I |
Operating temperature | 16 – 35°C |
Refrigerant / capacity | R 290 / 140g |
Weight | 18 kg |
Noise level | 65 dB(A) |
Intake pressure | 2.6 / 1.0 MPa |
Minimum room floor area | 4 m² |
Hot Air Stop accessories (online under the Service address www.domest.nl )| 5050050 HAS01
Refrigerant
This mobile air conditioner contains the refrigerant R290. R290 is a
fluorinated greenhouse gas with a relative global warming potential (GWP) of 3
as defined by the Kyoto Protocol. The greenhouse gas may be harmful to the
environment and contribute to global warming if it is allowed to escape into
the atmosphere.
CE mark
At the time of its placement on the market, this product conforms to the
requirements laid down in the Council directives on the approximation of the
laws of the Member States relating to electromagnetic compatibility, Directive
2014/30/EU, of electrical equipment designed for use within certain voltage
limits (2014/35/EU). This product is identified with the CE mark and is
supplied with a declaration of conformity for examination by the market
supervisory authority.
Disposal of old appliances
This product is marked in accordance with the European Waste Electrical and Electronic Equipment (WEEE) Directive 2012/19/EU. This directive lays down the regulations for proper disposal of the product. Environmentally-friendly disposal prevents possible negative impacts on health that could be caused by improper disposal. The symbol on the product or packaging indicates that this product must not be disposed of with the normal domestic waste. The user must return the product to a collection point for the recycling of electrical and electronic waste. The prevailing local regulations must be observed for disposal. For further information, please contact your local authority.
General warranty terms
WARRANTY TERMS & CONDITIONS
- These warranty conditions apply exclusively to the original buyer and for domestic use of the appliance in the Netherlands. If the appliance is resold from user to user, the warranty becomes null and void.
- The warranty only applies if, in the event of a warranty claim, this warranty certificate with the original purchase invoice is shown by the original buyer.
- No guarantee shall apply to defects caused by: damage, rough or injudicious handling, negligence on the part of the user, use of the appliance at an incorrect voltage or use for a purpose other than that for which it was supplied.
- Nor can the warranty be invoked when the rating plate with serial number has been changed or removed and/or when the device has been worked on by unqualified persons.
- Not covered under the terms of this warranty: glass(ceramic), lighting, plastic/metal parts and/or accessories (i.e. filters, grills, pan supports), wire baskets and/or separation partitions, lacquer and/or enamel damage.
- The warranty period commences on the day of purchase and covers:
- A two-year guarantee on the entire device and its electrical parts such as a thermostat, thermal protection, relay, ventilation fan, transformer, switch, etc. with the exception of all parts mentioned under 4.
- The warranty only covers the replacement of defective- or damaged parts in accordance with the stated responsibility in these warranty conditions.
- Call-out charges, labor costs, transport and/or packaging costs as well as the transportation risk (for equipment that can only be repaired in our service department) are not covered by the guarantee and will be charged to the user. Please also read the ‘Service Terms’ below in which, among other things, calculation of call-out charges and labour costs are specified.
- P.S. Repair costs must be paid directly in cash. If invoicing of the mechanic’s costs is required, please take into account that additional administration costs will be charged.
- We are not responsible for any work- and/or repair costs carried out by third parties, not commissioned by by us. Nor are we, at any time, responsible for any (extra) costs and/or any consequences thereof, in any case, directly or
- indirectly resulting from a malfunction, defect or injudicious use of the device caused by a 3rd party not deployed by Exquisit, its importer and/or suppliers.
- Replacement of parts does not extend the original warranty period.
SE RVICE TERMS EXQUISITE
- Do not use damaged appliances upon receipt, but report this immediately to your supplier. It is not possible to return damaged, used appliances!
- During the first 24 months after the date of purchase on the original invoice, no costs will be charged for services that are covered by these applicable warranty terms and conditions.
- After a warranty period of two years, starting on the date of purchase on the original invoice, costs wil be charged for:
- a. Call-out costs
- b. Labour costs
- c. All replaced parts
- In case of a visit to the customer all costs and materials used, must be paid directly in cash in accordance with the stipulations stated in point 7 in the Warranty Terms & Conditions and in points 2-4 in the Service Terms Exquisit, regardless of the nature of the work.
- Dispatch of any parts will always take place under the conditions of cash on delivery, C.O.D.
For service → EXQUISITE www.domest.nl – see
service
Phone 0314 – 362244 (optie 2)
Fax 0314 – 378232
E-mail: service@domest.nl
This limitation shall not apply to faultless work carried out by a qualified
person using our original parts to adapt the appliance to the technical safety
regulations of another EU member state. Scope Our warranty applies to
appliances purchased in an EU member state and operated in the Federal
Republic of Germany or Austria. For appliances purchased in one EU member
state and moved to another EU member state, defect remedies will be carried
out within the framework of the national warranty terms. The obligation to
provide services under warranty shall apply only as long as the appliance
satisfies the technical regulation of the country in which the warranty claim
is made.
For repairs outside the warranty period:
- If an appliance is repaired, the repair invoices are payable immediately without deduction.
- If an appliance is inspected or a started repair is not completed, flat-rate traveling expenses and labor costs will be invoiced. Advice from our After Sales Service centre is free of charge.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>