GPS Air IDF-2 Ceiling Tile Fan Instruction Manual
- June 12, 2024
- GPS Air
Table of Contents
- GPS Air IDF-2 Ceiling Tile Fan
- Product Information
- Product Usage Instructions
- What’s Included
- Location
- Parts List
- Installation
- Wiring
- Operation
- Ionizer Cleaning Cycle
- Cleaning and Maintenance
- Troubleshooting
- Product Registration
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
GPS Air IDF-2 Ceiling Tile Fan
Product Information
The IDF-2TM air ionization system from GPS Air is a high-quality product
designed to improve air quality in various environments. It comes with a
comprehensive Installation, Operation & Maintenance Manual for easy setup and
maintenance. The system
includes the IDF-2 air ionization system, Installation, Operation &
Maintenance Manual, and a Remote Control. However, it does not include
electrical wiring, junction box, or receptacle for power connection.
Location
The IDF-2 should be installed in a suitable location where it can effectively improve air quality. Please refer to the Installation section in the manual for detailed instructions on proper placement.
Wiring
The IDF-2 requires a power source of 120-240 VAC. It is recommended to connect
the IDF-2 to a switched power source, such as a lighting circuit. If
connecting to a non-switched circuit, ensure there is a means of disconnecting
power from the fan. Follow
the provided instructions and use a 1/2 trade size conduit fitting or grommet
for incoming power connections.
Product Usage Instructions
Installation
- Remove the ceiling tile where the IDF-2 will be installed.
- Insert the IDF-2 diagonally through the opening and gently place it onto the 2′ x 2′ ceiling frame.
- Slide the adjacent ceiling tile away to allow easy access to the terminal block.
- Using a Philips-head screwdriver, remove the terminal block cover and keep the screws for reassembly.
Wiring
- The IDF-2 requires a 120-240 VAC power source.
- GPS recommends connecting the IDF-2 to a switched power source.
- If wiring to a non-switched circuit, ensure there is a means of disconnecting power from the fan.
- Using a 1/2 trade size conduit fitting or grommet, connect the incoming power wires as follows: Neutral/L2 Line/L1.
- Reattach the terminal block cover.
Operation
The IDF-2 can be operated using the included Remote Control. The Remote Control functions are as follows:
- Speed: High
- Speed: Medium
- Speed: Low
- Power: On
- Power: Off
Note: The remote control can be used to operate a single fan system or multiple fans simultaneously. Before powering up the appliance, ensure all guarding is installed properly.
Ionizer Cleaning Cycle
The IDF-2’s ionizer has a preset cleaning cycle to clean the emitters twice per day. No manual intervention is necessary for this cleaning cycle.
Cleaning and Maintenance
Cleaning and maintenance should only be performed by qualified personnel. Follow the steps below:
- Ensure that the IDF-2 is powered off.
- Support the diffuser with one hand and remove the diffuser cap by turning it counter clockwise.
- Use a clean cloth to wipe the diffuser and the area highlighted in blue (shown in the figure in the manual).
- To access the fan blades, remove the bottom housing. Use a Philips-head screwdriver to remove the screw on the side of the fan and rotate 4 thumb screws located on each corner of the fan counter clockwise.
- Once the screws are removed, gently allow the bottom housing to rotate downwards and use a clean cloth to wipe any visible dust and debris.
- Reassemble the bottom housing and fan in reverse order, ensuring not to cross-thread the thumb screws.
Please refer to the complete Installation, Operation & Maintenance Manual for more detailed instructions and safety information.
NOTICE: This product is to be used only as directed. Read entire manual before use. Do not use unless properly installed.
Thank you for purchasing an IDF-2™ air ionization system from GPS Air.
What’s Included
Before you start, confirm the contents of your shipment. Each IDF-2™ will consist of the following:
- IDF-2 air ionization system
- Installation, Operation & Maintenance Manual
- Remote Control
Not Included
- Electrical wiring, junction box, or receptacle to provide power to the IDF-2
- 1/2” trade size conduit fitting or grommet for incoming power connection
As part of the installation process, a Startup Document should be completed. For the latest version of the document, visit our website or utilize the QR code.\
Location
- Please read the operation manual before use.
- The IDF-2 shall be installed such that it is at least 7.5′ above the floor.
- The IDF-2 is to be mounted on a suspended ceiling system (24” x 24”) that can fully support it’s weight (11.5 lbs).
- For non drop ceilings use the ceiling box mount accessory (sold separately).
- Do not insert hands or materials into the diffuser grille or touch the fan when the tile fan is running.
- To avoid the risk of shock, disconnect the electricity before cleaning.
- Installation must be in accordance with local electrical wiring regulations.
- Regularly clean and maintain the fan.
- Handle remote controller with care.
- Do not allow anything to obstruct the fan or diffuser grille.
- Installation and maintenance must be performed by a trained professional.
- Children should be properly supervised to ensure that they do not come into contact with the appliance.
Parts List
Installation
- Remove the ceiling tile where the IDF-2 will be installed.
- Insert the IDF-2 diagonally through the opening and place gently onto the 2’ x 2’ ceiling frame.
- Slide the adjacent ceiling tile away to allow easy access to the terminal block.
- Remove the terminal block cover with a Philips-head screwdriver. Keep screws for reassembly.
Wiring
- The IDF-2 requires a 120-240 VAC power source.
- GPS recommends the IDF-2 be connected to a switched power source such as a lighting circuit.
- If wiring to a non-switched circuit, a means of disconnecting power from the fan is required.
- Using a 1/2” trade size conduit fitting or grommet on incoming power wires, connect as follows:
- Reattach the terminal block cover.
Caution: the ionizer secondary voltage is +- 3.5kV
Operation
BEFORE USE, BE SURE:
- There are no foreign objects inside the circulating fan.
- The power is connected.
- The circulating fan is installed securely.
REMOTE CONTROL FUNCTIONS:
- Speed: High
- Speed: Medium
- Speed: Low
- Power: On
- Power: Off
The fan will begin to spin each time it powers up. Ensure all guarding is installed before powering up the appliance.
Note: The remote control can be used to operate a single fan system or multiple fans at the same time.
Ionizer Cleaning Cycle
The ionizer in the IDF-2 comes with a preset cleaning cycle designed to clean the emitters twice per day.
Cleaning and Maintenance
Cleaning and maintenance should only be performed by qualified personnel
- Ensure that the IDF-2 is powered off
- Support the diffuser with one hand while removing the difuser cap (turn counter clockwise). Once removed use a clean cloth to wipe the diffuser (highlighted in blue).
- Use a clean cloth to wipe the area highlighted in blue (shown in the figure below).
- Remove the bottom housing for access to the fan blades.
- Use a Philips-head screwdriver and remove the screw located on the side of the fan.
- Remove 4 thumb screws located on each corner of the fan by rotating counter clockwise.
- Once the screw and 4 thumbs screws are removed gently allow the bottom housing to rotate downwards. Use a clean cloth to wipe any visible dust and debris.
- Reassemble in reverse order being careful to not cross thread the thumbscrews.
Troubleshooting
PROBLEM POSSIBLE CAUSE SOLUTIONS
Air movement fan does not operate| Main fan motor
malfunction| Contact GPS representative for additional assistance
---|---|---
Diffuser grille does not operate| Diffuser motor
malfunction| Contact GPS representative for additional assistance
---|---|---
Fan makes unusual noise| IDF-2 is vibrating / out of
balance| Ensure IDF-2 is installed correctly
---|---|---
Diffuser grille is in contact with main body| ****
Check and if necessary reattach the diffuser grille
Loose fan cap| Tighten the fan cap
IDF-2 is dirty| See ‘Cleaning and Maintenance’
Damage to motor bearing| Contact GPS representative for additional assistance
Product Registration
By registering your order, the standard limited warranty on eligible products
from your purchase is automatically extended to 3 years, at no additional
cost.
Register your products at www.gpsair.com/product-
registration or scan the QR code.
The information provided in this manual is up to date at the time of printing. Any revisions to this document will supersede the content included. For the latest applicable version of this manual, visit our website or utilize the QR code.
The health aspects associated with the use of this product and its ability to
aid in disinfenction of environmental air have not been investigated by UL.
This product shall not be installed behind a structural wall, ceiling, or
floor.
3101 Yorkmont Road • Suite 400 Charlotte, NC 28208 980-279-5622
To access a list of applicable patents, please visit www.gpspatents.com
© 2023 GPS Air
GPS Air is the owner of certain trademarks that appear in our materials.
Please visit www.gpsair.com/trademarks for
a list of our marks.
References
- GPS Air | Optimize Your Indoor Air Quality | GPS Air IAQ Solutions
- GPS Air | Optimize Your Indoor Air Quality | GPS Air IAQ Solutions
- GPS Air | Product Registration
- GPS Air | trademarks