GOODWE GM3000 Smart Meter User Manual

June 5, 2024
GOODWE

GOODWE GM3000 Smart Meter

GOODWE-GM3000-Smart-Meter-PRODUCT

OVERVIEW

SMART METER OVERVIEW

GOODWE-GM3000-Smart-Meter-1

  1. Power LED
  2. Energy Consumption LED
  3. Communications LED
  4. Reset Switch
  5. USB Port

INTRODUCTION

GoodWe Smart Meter is designed with high precision small dimensions, convenient operation and installation. It is available for both single-phase and three-phase grid system connection to detect voltage, current, power and energy, for working with inverters including SEMS systems for the purpose energy management. Any fault or damage caused by misoperation or disobeyal against the rules on manual is beyond GoodWe warrenty cover range.

PACKING LIST

  • 1* Smart Meter
  • 1* Screw Driver
  • 1* USB Seal
  • 1* CT (Current Transformer)[1]
  • 4* Cable Connection Terminals
  • 1* RJ45-to-Pin Cable[2]

NOTE:

  1. A three-phase Meter will contain 3 CT clamps. Specifications are subject to the physical product.
  2. Only suitable for RS485 cable connection on RJ45 port of GoodWe hybrid inverters

WIRING CONNECTION

WIRING FOR SINGLE-PHASE METER

GOODWE-GM3000-Smart-Meter-4

Correct direction of CT: House (K)→Grid (L). ncorrect connection or direction will cause incorrect data.

WIRING FOR THREE-PHASE METER

GOODWE-GM3000-Smart-Meter-5

  • Correct direction of CT: House (K)→Grid (L).
  • Ensure CT and corresponding supply cable are connected to the same phase.
  • Incorrect connection or direction will cause incorrect data and may damage the meter.

ELECTRICAL DATA

MODEL GM1000 GM3000
APPLICATION Single-phase Three-phase


Voltage

| Nominal Voltage| 230Vac| 3L+N/400Vac
Voltage Range| 0.7~1.2Un| 0.7~1.2Un
Frequency| 50Hz/60Hz


Current Input

| Nominal Current| CT in:120A/40mA
Current Range| 0.48A~120A
Self-Consumption| 3W max
Data Detection| Voltage/Current/Active Power/ Reactive Power/Power Factor/Frequency
Energy Calculation| Active/Reactive Power Energy



Precision

| Voltage/Current| Class 1
Active Power| Class 1
Reactive Power| Class 2
Comm.| With Inverter| RS485 (Bund Rate 9600 / ModBus Protocol / communication cable max. length 100m)

INTERFACE

INDICATORS

  • Power LED :
    Normal operation: ON

  • Energy Consumption LED:
    Consuming: On Generating: Blinking

  • Communication LED:
    Transmitting data: Blinking Resetting: Blink 5 times

RESET BUTTON

Press Function
<3s Meter Reset
5s Meter Settings Initialization
>10s Meter Initialize settings and clear energy data

USB PORT
For after-sales maintenance

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals