Danby DAC145EB6WDB-6 14500 BTU Window Air Conditioner Owner’s Manual
- June 5, 2024
- Danby
Table of Contents
- Danby D AC145EB6WDB-6 14500 BTU Window Air Conditioner
- Important Safety Information
- SAFETY PRECAUTIONS
- Information on servicing
- INSTALLATION INSTRUCTIONS
- REQUIRED TOOLS
- ACCESSORIES
- INSTALLATION
- OPERATING INSTRUCTIONS
- REMOTE CONTROL
- FREQUENTLY ASKED QUESTIONS
- TROUBLESHOOTING
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Danby D AC145EB6WDB-6 14500 BTU Window Air Conditioner
Welcome to the Danby family
We are proud of our quality products and we believe in dependable service. We
suggest that you read this owner’s manual before plugging in your new
appliance as it contains important operation information, safety information,
troubleshooting, and maintenance tips to ensure the reliability and longevity
of your appliance.
You are entitled to the warranty coverage as described in the owner’s manual
provided with your new appliance.
- Please write down your appliance information below. You must keep the original proof of purchase receipt to validate and receive warranty services.
- Register your product online and receive a FREE 2 MONTH WARRANTY EXTENSION after fi lling out a product survey, at www.danby.com/support/product-registration/
Need Help?
- Read your Owner’s Manual for installation help, troubleshooting, and maintenance assistance.
- Visit www.Danby.com to access self-service tools, FAQs and much more by searching your model number in the search bar.
- For the Quickest Customer Service, please fi ll out the web form at www.danby.com/support. Your submission will go directly to an expert on your particular appliance. Our average response times are between 20 minutes and 2 hours, during EST business hours.
- Call 1-800-263-2629 – please note that during peak hours, hold times can exceed one hour.
Important Safety Information
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
| WARNING| Shows that the appliance uses a flammable refrigerant. If the
refrigerant leaks and is exposed to an external ignition source, there is a
risk of fire.
---|---|---
| CAUTION| Shows that the operation manual should be read carefully.
****| CAUTION| Shows that service personnel should be handling this
equipment with reference to the installation manual.
| CAUTION| Shows that the information is available such as the operating
manual or the installation manual.
CAUTION: RISK OF FIRE
Flammable refrigerant used. When maintaining or disposing of the air conditioner, the refrigerant must not be allowed to vent into the open air.
SAFETY PRECAUTIONS
WARNING
- Installation must be performed according to the installation instructions. Improper installation can cause water leakage, electrical shock or fi re.
- Use only the included accessories and parts and specifi ed tools for the installation. Using non-standard parts can cause water leakage, electrical shock, fi re and injury or property damage.
- Make sure that the outlet you are using is grounded and has the appropriate voltage. The power cord is equipped with a three-prong grounding plug to protect against shock. Voltage information can be found on the nameplate of the unit.
- You unit must be used in a properly grounded wall receptacle. if the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker (the fuse of circuit breaker needed is determined by the maximum current of the unit. The maximum current is indicated on the nameplate located on the unit), have a qualifi ed electrician install the proper receptacle.
- Install the unit on a fl at, sturdy surface. Failure to do so could result in damage or excessive noise and vibration.
- The unit must be kept free from obstruction to ensure proper function and to mitigate safety hazards.
- Do not modify the length of the power cord or use an extension cord to power the unit.
- Do not share a single outlet with other electrical appliances. Improper power supply can cause fi re or electrical shock.
- Do not install you air conditioner in a wet room such as a bathroom or laundry room. Too much exposure to water can cause electrical components to short circuit.
- Do not install the unit in a location that may be exposed to combustible fas as this could cause fi re.
- The unit has wheels to facilitate moving. Make sure not to use the wheels on thick carpet or to roll over objects as this could cause tipping.
- Do not operate a unit that been dropped or damaged.
- The appliance with the electric heater shall have at least 1 meter space from combustible materials.
- Do not touch the unit with wet or damp hands or when barefoot.
- If the air conditioner is knocked over during use, turn off the unit and unplug it from the main power supply immediately. Visually inspect the unit to ensure there is no damage. If you suspect the unit has been damaged contact a technician or customer service for assistance.
- In a thunderstorm, the power must be cut off to avoid damage to the machine due to lightning.
- You air conditioner should be used in such a way that it is protected from moisture. e.g. condensation, splashed water, etc. Do not place or store you air conditioner where it can fall or be pulled into water or any other liquid.
- Unplug immediately if this occurs.
- All wiring must be performed strictly in accordance with the wiring diagram location inside the unit.
- The units circuit board (PCB) is designed with a fuse to provide over current protection. The specifi cations of the fuse are printed on the circuit board.
- When the water drainage function is not in use keep the upper and lower drain plugs fi rmly installed in the unit. The drain plugs can be a choking hazard to children.
CAUTION
- This appliance is not intended for use by persons (including children) whose physical, sensory or mental capabilities may be different or reduced, or who lack experience or knowledge, unless such persons receive supervision or training to operate the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. Children must be supervised around the unit at all times.
- If the power supply cord is damaged it must be replaced by the manufacturer, its service agent or similarly qualifi ed persons in order to avoid a hazard.
- Prior to cleaning or other maintenance, the appliance must be disconnected from the power supply.
- Do not remove any fi xed covers. Never use this appliance if it is not working properly or if it has been dropped or damaged.
- Do not run cord under carpeting. Do not cover cord with throw rugs, runners or similar coverings. Do not route cord under furniture or appliances. Arrange cords away from traffi c and where it will not be tripped over.
- Do not operate a unit with a damaged power cord, plug, power fuse or circuit breaker. Discard the unit or return to an authorized service facility for examination and/or repair.
- To reduce the risk of fi re or electric shock do not use this air conditioner with any solid-state speed control device.
- The appliance shall be installed in accordance with national wiring regulations.
- Contact the authorized service technician for repair or maintenance of this unit.
- Contact the authorized service installer for installation of this unit.
- Do not cover or obstruct the inlet or outlet grilles.
- Do not use this product for functions other than those described in this instruction manual.
- Before cleaning turn off the power and unplug the unit.
- Disconnect the power if strange sounds, smells or smoke comes from it.
- Do not press the buttons on the control panel with anything other than your fi ngers.
- Do not remove any fi xed covers. Never use this appliance if it is not working properly or if it has been dropped or damaged.
- Do not operate or stop the unit by inserting or pulling out the power cord plug.
- Do not use hazardous chemicals to clean or come into contact with the unit. Do not use the unit in the presence of infl ammable substances or vapour such as alcohol, insecticides, petrol, etc.
- Always transport your air conditioner in a vertical position and stand on a stable, level surface during use.
- Always contact a qualifi ed person to carry out repairs. If the damaged power supply cord must be replaced with a new power supply cord obtained from the product manufacturer and not repaired.
- Hold the plug by the head of the power plug when removing it.
- Turn off the appliance when not in use.
Note about fl uorinated gasses
- Fluorinated greenhouse gases are contained in hermetically sealed equipment. For specifi c information on the type, the amount and the C02 equivalent in tonnes of the fl uorinated greenhouse gas on some models. Please refer to the relevant label on the unit itself.
- Installation, service, maintenance and repair of this unit must be performed by a certifi ed technician.
- Product installation and recycling must be performed by a certifi ed technician.
WARNING for using R32 refrigerant
- Do not use means to accelerate the defrosting process or to clean other than those recommended by the manufacturer.
- The appliance shall be stored in a room without continuously operating ignition sources for example, open fl ames, an operating gas appliance or an operating electric heater.
- Do not pierce or burn.
- Be aware that the refrigerants may not contain an odour.
- The appliance should be installed, operated and stored in a room with a fl oor area according to the amount of refrigerant to be charged. For specifi c information on the type of gas and the amount, please refer to the relevant label on the unit itself. When there are differences between the label and the manual on the minimum room area description, the description on the label shall prevail.
- Compliance with national gas regulations shall be observed.
- Keep ventilation openings clear of obstruction.
- The appliance shall be stored so as to prevent mechanical damage from occurring.
- A warning that the appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specifi ed for operation.
- Any person involved with working on the refrigerant circuit should hold a current, valid certificate from industry accredited assessment authority which authorizes their competence to handle refrigerants safely in
- accordance with an industry-recognized assessment specifi cation.
- Servicing shall only be performed as recommended by the manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use
- of flammable refrigerants.
- Please follow the instruction carefully to handle, install, clear and service the air conditioner to avoid any damage or hazard. Flammable refrigerant R32 is used within this air conditioner. When maintaining or disposing of the air conditioner the refrigerant must be recovered properly and should not be allowed to discharge to the air directly.
- No open fi re or device-like switch which may generate spark/arcing shall be around air conditioner to avoid causing ignition of the flammable refrigerant used.
- Please follow the instruction carefully to store or maintain the air conditioner to prevent mechanical damage from occurring.
- Flammable refrigerant -R32 is used in air conditioners. Please follow the instruction carefully to avoid any hazard. For specifi c information on the type of gas and the amount, please to the relevant label on the unit itself.
- The appliance shall be stored in a room without continuously operating open fl ames (for example an operating gas appliance) and ignition sources (for example an operating electric heater).
- Transport of equipment containing fl ammable refrigerants
- See transport regulations.
- Marking of equipment using signs
- See local regulations.
- Disposal of equipment using flammable refrigerants
- See national regulations.
- Storage of equipment/appliances
- The storage of equipment should be in accordance with the manufacturer’s instructions.
- Storage of packed (unsold) equipment
- Storage package protection should be constructed such that the mechanical damage to the equipment inside the package will not cause a leak of the refrigerant charge. The maximum number of pieces of equipment permitted to be stored together will be determined by local regulations.
Information on servicing
-
Checks to the area: Prior to beginning work on systems containing fl ammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.
-
Work procedure: Work shall be undertaken under a controlled procedure so as to minimize the risk of a flammable gas or vapour being present while the work is being performed.
-
General work area: All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confi ned spaces shall be avoided. The area around the work space shall be sectioned off. Ensure that the conditions within the work area have been made safe by removing all flammable material.
-
Checking for the presence of refrigerant: The area shall be checked with an appropriate refrigerant detector prior to and during work to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, i.e. non-sparking, adequately sealed and intrinsically safe.
-
Presence of fi re extinguisher: If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fi re extinguishing equipment shall be available to hand. Have a dry powder or C02 fi re extinguisher adjacent to the work area.
-
No ignition sources: No person carrying out work in relation to a refrigeration system that involves exposing any pipework that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to risk of fi re or explosion. All possible ignition sources including cigarette smoking, should be kept suffi ciently far away from the site of installation, repairing, removing and disposal during which fl ammable refrigerant can possibly be released to the surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make sure there are no flammable hazards or ignition risks. No smoking signs shall be displayed.
-
Ventilated area: Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.
-
Checks to the refrigeration equipment: Where electrical components are being changed, they shall be fi t for the purpose and to the correct specifi cation. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt consult the manufacturer’s technical department for assistance.The following checks shall be applied to installations using flammable refrigerants:
-
The charge size is in accordance with the room size within which the refrigerant-containing parts are installed.
-
The ventilation machinery and outlets are operating adequately and are not obstructed.
-
If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant.
-
Marking to the equipment continues to be visible and legible. Markings and signs that become illegible must be corrected.
-
Refrigeration pipe or components are installed in a position where they are unlikely to be exposed
to any substance which may corrode refrigerant-containing components, unless the components are constructed of materials that are inherently resistant to being corroded or are suitably protected against being corroded. -
Checks to electrical devices: Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are advised.
Initial safety checks shall include
- That capacitor are discharged. This shall be done in a safe manner to avoid possibility of sparking.
- That no live electrical components and wiring are exposed while charging, recovering or purging the system.
- That there is continuity of earth bonding.
Repairs to sealed components
- During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers, etc. If it is absolutely necessary to have an electrical supply to equipment during servicing then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation.
- To ensure that by working on electrical components the casing is not altered in such a way that the level of protection is affected, particular attention shall be paid to the following:
- Damage to cables, excessive number of connections, terminals not made to original specifi cation, damage to seals, incorrect fi tting of glands, etc.
- Ensure the apparatus is mounted securely.
- Ensure that seals or sealing materials have not degraded such that they no longer serve the purpose of preventing the ingress of fl ammable atmospheres. Replacement parts shall be in accordance with the manufacturer’s specifi cations.
Note: The use of silicon sealant may inhibit the effectiveness of some
types of leak detection equipment. Intrinsically safe components do not have
to be isolated prior to working on them.
Repair to intrinsically safe components
Do not apply any permanent inductive or capacitance loads to the circuit
without ensuring that this
will not exceed the permissible voltage and current permitted for the
equipment in use. Intrinsically
safe components are the only types that can be worked on while live in the
presence of a fl ammable atmosphere. The test apparatus shall be at the correct
rating. Replace components only with parts specifi ed by the manufacturer.
Other parts may result in the ignition of refrigerant in the atmosphere from a
leak.
Cabling
Check that cabling will not be subject to wear, corrosion, excessive pressure,
vibration, sharp edges or any other adverse environmental effects. The check
shall also take into account the effects of aging or continual vibration from
sources such as compressors or fans.
Detection of fl ammable refrigerants
Under no circumstances shall potential sources of ignition be used in the
searching for or detection of refrigerant leaks. A halide torch or any other
detector using a naked flame shall not be used.
Leak detection methods
The following leak detection methods are deemed acceptable for systems
containing flammable refrigerants:
- Electronic leak detectors shall be used to detect fl ammable refrigerants but the sensitivity may not be adequate or may need recalibration. Detection equipment shall be calibrated in a refrigerant-free area. Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used.
- Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and shall be calibrated to the refrigerant employed and the appropriate percentage of gas (25% maximum) is confi rmed.
- Leak detection fl uids are suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper or pipe-work.
- If a leak is suspected, all naked fl ames shall be removed or extinguished.
- If a leakage of refrigerant is found which requires brazing, all of the refrigerant shall be recovered from the system or isolated by means of shut off valves in a part of the system remote from the leak. Oxygen free nitrogen (OFN) shall then be purged through the system both before and during the brazing process.
Removal and evacuation
When breaking into the refrigerant circuit to make repairs or for any other
purpose conventional procedures shall be used. However, it is important that
the best practice is followed since fl ammability is a consideration. The
following procedures shall be adhered to:
- Remove refrigerant.
- Purge the circuit with inert gas.
- Evacuate.
- Purge again with inert gas.
- Open the circuit by cutting or brazing.
- The refrigerant charge shall be recovered into the correct recovery cylinders. The system shall be ushed with OFN to render the unit safe. This process may need to be repeated several times. Compressed air or oxygen shall not be used for this task.
- Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fi ll until the working pressure is achieved, then venting to atmosphere and finally pulling down to a vacuum. This process shall be repeated until no refrigerant is within the system. When the fi nal OFN charge is used, the system shall be vented down to atmospheric pressure to enable work to take place. This operation is absolutely vital is brazing operations on the pipe-work are to take place.
- Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available.
Charging procedures
In addition to conventional charging procedures, the following requirements
shall be followed:
- Ensure that contamination of different refrigerants does not occur when using charging equipment. Hoses or lines shall be as short as possible to minimize the amount of refrigerant contained in them.
- Cylinders shall be kept upright.
- Ensure that the refrigeration system is earthed prior to charging the system with refrigerant.
- Label the system when charging is complete, if not already labeled.
- Extreme care shall be taken not to overfi ll the refrigeration system.
- Prior to recharging the system it shall be pressure tested with OFN. The system shall be leak tested on completion of charging but prior to commissioning. A follow-up leak test shall be carried out prior to leaving the site.
Decommissioning
Before carrying out this procedure, it is essential that the technician is
completely familiar with the equipment in all its detail. It is recommended
good practice that all refrigerants are recovered safely. Prior to the task
being carried out, an oil and refrigerant sample shall be taken in case
analysis is required prior to re-use of reclaimed refrigerant. It is essential
that electrical power is available before the task is commenced.
- A. Become familiar with the equipment and its operation.
- B. Isolate system electrically.
- C. Before attempting the procedure ensure that:
- Mechanical handling equipment is available if required for handling refrigerant cylinders.
- All personal protective equipment is available and being used correctly.
- The recovery process is supervised at all times by a competent person.
- Recovery equipment and cylinders conform to the appropriate standards.
- D. Pump down refrigerant system, if possible.
- E. If a vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of the system.
- F. Make sure that cylinder is situated on the scales before recovery takes place.
- G. Start the recovery machine and operate in accordance with the manufacturer’s instructions.
- H. Do not overfi ll cylinders. No more than 80% volume liquid charge.
- I. Do not exceed the maximum working pressure of the cylinder, even temporarily.
- J. When the cylinders have been fi lled correctly and the process is completed, make sure that the cylinders and the equipment are removed from the site promptly and all isolation valves on the equipment are closed off.
- K. Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked.
Labeling
Equipment shall be labeled stating that it has been decommissioned and emptied
of refrigerant. The label shall be dated and signed. Ensure that there are
labels on the equipment stating the equipment contains fl ammable refrigerant.
Recovery
When removing refrigerant from a system, either for servicing or
decommissioning, it is recommended good practice that all refrigerants are
removed safely.
When transferring refrigerant into cylinders, ensure that only appropriate
refrigerant recovers cylinders are employed. Ensure that the correct number of
cylinders for holding the total system charge are available. All cylinders to
be used are designed for the recovered refrigerant and labeled for that
refrigerant, i.e. special cylinders for the recovery of refrigerant. Cylinders
shall be complete with pressure relief valve and associated shut-off valves in
good working order. Empty recovery cylinders are evacuated and, if possible,
cooled before recovery occurs.
The recovery equipment shall be in good working order with a set of
instructions concerning the equipment that is at hand and shall be suitable
for the recovery of fl ammable refrigerants. In addition, a set of calibrated
weighing scales shall be available and in good working order. Hoses shall be
complete with leak-free disconnect couplings and in good condition. Before
using the recovery machine, check that is it in satisfactory working order,
has been properly maintained and that any associated electrical components are
sealed to prevent ignition in the event of a refrigerant leak. Consult the
manufacturer if in doubt.
The recovered refrigerant shall be returned to the refrigerant supplier in the
correct recovery cylinder
and the relevant waste transfer note shall be arranged. Do not mix
refrigerants in recovery units and especially not in cylinders. If compressors
or compressor oils are to be removed, ensure that they have been evacuated to
an acceptable level to make certain that flammable refrigerant does not remain
within the lubricant. The evacuation process shall be carried out prior to
returning the compressor to the suppliers. Only electric heating to the
compressor body shall be employed to accelerate this process. When oil is
drained form a system, it shall be carried out safely.
INSTALLATION INSTRUCTIONS
LOCATION
This air conditioner is designed for single or double-hung windows. Since
window designs vary, it may be necessary to make some modifi cations for safe
installation. This air conditioner is not designed for vertical, slider-type
windows or “through the wall” installation. Ensure that the window and frame
are structurally sound and free from dry or rotted wood. Install the air
conditioner in a window on a side of the building which favors more shade than
sunlight. If the appliance must be in direct sunlight, it is advisable to
provide a shade awning over the appliance to ensure effi cient functioning. Do
not install the appliance where leakage of combustible gas is suspected.
This appliance is designed to evaporate condensation under normal conditions.
Under extremely hot or humid conditions, excess condensation may overfl ow to
the outside. The appliance should be installed where condensation cannot drip
on pedestrians or neighboring properties. Provide suffi cient clearance around
the appliance to allow ample air circulation. The rear of the appliance should
be outdoors, it should not be in a garage or another room. Keep the appliance
away from obstacles and at least 76 cm (30 inches) above the ground. Ensure
that curtains and other obstructions do not block air fl ow to the appliance.
REQUIRED TOOLS
- Screwdrivers: Phillips and flat head.
- Power Drill: 3.2mm (1/8”) diameter drill bit
- Pencil
- Measuring Tape
- Scissors
- Carpenter’s Level
ACCESSORIES
The following accessories are included with the appliance and should be used during the installation.
- 13 mm (1/2 inch) screws (x7)
- 9.5 mm (3/8 inch) screws (x4) (Factory-installed on some models.)
- Safety Lock
- Adhesive foam seal
- Regular foam seal
- “L” shaped mounting bracket (Factory-installed on some models.)
- Bracket for wood windows (x2)
- Bracket for vinyl windows (x2)
- Weatherstripping (x5)
- Side curtains (x2)
INSTALLATION
Attach the side curtains to the appliance by sliding the curtain frame into
the side channel of the cabinet. The curtains are labeled “left” and “right on
the frames. This refers to the left and right
sides of the appliance when facing the front of the appliance.
Cut the regular foam seal to fi t the area of the window sill that the air
conditioner will rest on.
Place the air conditioner into the window with the “L” shaped mounting bracket
positioned in front of the upper sash. The bottom of the cabinet should be
positioned on the recessed portion of the window frame. Pull the upper window
sash down until it rests just behind the front fl ange of the “L” shaped
mounting bracket.
Expand the side curtains on each side and secure the top of the frames to the
window sash using one 13 mm (1/2”) screw on each side of the “L” shaped
mounting bracket.
Attach the clamps on the lower part of each curtain to the window sill using
one 13 mm (1/2”) screw on each side of the cabinet.
Place the adhesive foam seal into the opening between the inside and outside
windows and attached the safety lock to the outside window frame using two 13
mm (1/2”) screws.
Check the Tilt Angle
The air conditioner should be tilted down towards the outside approximately 3°
to 4°. This tilt will encourage any condensed water to drain to the outside.
If any condensed water leaks to the inside of the house, check the tilt angle
and adjust as necessary. Measure the tilt angle from the front of the
cabinet’s edge. The difference in height between the front and the back of the
appliance, labeled “A” on the image below, should be approximately:2.5 cm –
3.5 cm (1” – 1 3/8”)
L BRACKET
The “L” shaped bracket may come factory installed on some models.
If the “L” shaped bracket is not pre-installed, attach it to the top of the
cabinet as shown below using the provided 9.5 mm (3/8”) screws (x4).
OPERATING INSTRUCTIONS
CONTROL PANEL
- Remote Control Receiver: Ensure this receiver is not obscured by curtains or other items as it could impact remote control functioning.
- Follow Me Indicator Light: Illuminates when the Follow Me function is active. Follow Me can only be set from the remote control.
- Power Button: Used to turn the appliance on or off.
- Mode Button: Used to choose the operating mode.
- Temperature Control Buttons: Used to adjust the set temperature in 1° increment and the timer function in 30-minute increments up to 10 hours and then in 1-hour increments up to 24 hours.
- Display Panel: Displays the set temperature, the ambient temperature and the timer settings. To change the temperature scale being displayed, press the up and down buttons at the same time.
- Fan Button: Used to set the fan speed. The fan can be set to Low, Medium, High and Auto.
- Wireless connect button: Used to connect to a wireless network.
- Energy Saver Button: Used to set the energy saver function.
- Filter Button: The indicator light will illuminate as a reminder to check the fi lter. Once the fi lter has been cleaned, use this button to resume operation.
- Sleep Button: Used to set the Sleep function.
- Timer Button: Used to set the auto on and auto off timer.
REMOTE CONTROL
- Display Panel: Displays the set temperature and the timer settings. To change the temperature scale being displayed, press the °C/°F button.
- Temperature Control Buttons: Used to adjust the set temperature in 1° increments and the timer function in 30 minute increments up to 10 hours and then in 1 hour increments up to 24 hours.
- Mode Button: Used to choose the operating mode.
- Follow Me Button: Used to set the follow me function.
- °C/°F button: Use to change the temperature scale.
- LED Button: Press to turn the LED backlight on or off.
- Power Button: Used to turn the appliance on or off.
- Sleep Button: Used to set the sleep function.
- Fan Button: Used to set the fan speed. The fan can be set to low, medium, high and auto.
- Timer On Button: Used to set the auto on a timer.
- Timer Off Button: Used to set the auto off timer.
- Energy Saver Button: Used to set the energy saver function.
- Lock Button: Press the °C/°F button and the timer button at the same time to lock the remote control and prevent the settings from being inadvertently changed.
REMOTE CONTROL BATTERIES
The remote control requires two AAA alkaline batteries (included). Batteries
should be replaced when:
- No sound is heard when attempting to program the appliance.
- The appliance does not respond to a command issued by the remote control.
Battery replacement
- Slide the rear cover on the remote in the direction of the arrow.
- Insert two AAA batteries following the same orientation depicted inside the battery chamber (+/-).
- Reinstall the rear cover.
- If the remote control will not be used for extended periods of time, the batteries should be removed.
Notes
- Protect the remote control from high temperatures, and keep it away from radiation exposure.
- Keep the control panel receiver out of direct sunlight.
- Do not mix old and new batteries.
- Do not mix alkaline, standard (carbon-zinc), or rechargeable (ni-cad, ni-mh,etc) batteries.
- The remote operates within a range of 8 meters (26 ft.) from the receiver located inside the main appliance. Any obstruction between the receiver and remote may cause signal interference, limiting the ability to program the main unit.
REMOTE CONTROL REGULATIONS
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the
following measures:
- Reorient or relocate the receiving antenna
- Increase the separation between the equipment and receiver
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
- Consult the dealer or an experienced radio/TV technician for help
Changes or modifi cations not approved by the party responsible for FCC and
Industry Canada compliance could void the user’s authority to operate the
equipment. This appliance complies with Part 15 of the FCC Rules and license-
exempt RSS standards.
Operation is subject to the following conditions:
- This device may not cause interference.
- This device must accept any interference received, including interference that may cause undesired operation.
This equipment complies with FCC RF and IC RSS-102 radiation exposure limits
set forth for an uncontrolled environment. This equipment should be installed
and operated with minimum distance 20cm(8 inches) between the radiator and
your body.
This device complies with RSS-247 of Industry Canada. Operation is subject to
the condition that this device does not cause harmful interference.
This device complies with Canadian CAN ICES-3 (B) / NMB-3 (B)
This device contains
- FCC ID: 24951-MZNA19
- IC: 12575A-MDNA19
OPERATING MODES
There are four operating modes to choose from. Press the mode button
repeatedly to choose the desired mode. The adjacent indicator light will
illuminate to show which mode has been selected.
- Cool Mode Choose cool mode to set the cooling function. Use the temperature control buttons to choose the desired temperature. When cool mode is selected, the fan speed can be adjusted by pressing the fan button.
- Dry Mode Choose dry mode to remove excess moisture from the air during periods of high humidity. All water pulled from the air will condense inside the appliance and drain out the back. The fan speed will be automatically set and cannot be modifi ed in dry mode.
- Fan Mode Choose fan mode to run the internal fan without engaging the cooling function. Press the fan button repeatedly to choose the fan speed.
- Auto Mode Auto mode is a pre-set factory program that automatically defi nes the mode and fan speed based on the set temperature, the ambient temperature and the ambient humidity.
TEMPERATURE CONTROL BUTTONS
The temperature control buttons will modify the set temperature in 1°
increment. The temperature control buttons will modify the set time of the
timer function in 0.5-hour increments up to 10 hours and then in 1-hour
increments up to 24 hours maximum.
-
SLEEP
The sleep function can be used to conserve energy during sleeping hours. When selected, the set temperature will increase by 1°C/2°F every half hour for one full hour. The appliance will hold the new set temperature for 6 hours before automatically returning to normal operation. The Sleep Function can be canceled at any time by pressing the Sleep Button. -
ENERGY SAVER
The energy saver function will automatically cycle the fan on and off when the compressor is not in use to minimize how often the compressor needs to turn on.
When selected, the fan will continue to run for 3 minutes after the compressor turns off. The fan will then cycle on for 2 minutes in 10 minute intervals until the ambient temperature is above the set temperature, at which point the compressor will turn on and cooling will resume. -
FOLLOW ME
There is a temperature sensor built into the remote control that will monitor the room temperature. Keep the remote control with you and the appliance will automatically adjust the set temperature based on the temperature where you are located.
The remote will display the temperature at its location. The remote will send a signal to the air conditioner every 3 minutes, so long as you remain within the range of the appliance.
The follow-me light on the control panel will illuminate for 5 seconds every 3 minutes to indicate that it has received a signal from the remote. If the appliance does not receive a signal from the remote during any 7-minute interval it will beep to indicate that the follow me mode has ended.
The maximum distance for the follow-me feature is 8 meters (26 feet). This feature is available in cool and auto modes. -
WIRELESS CONNECTION
This appliance can be controlled with a wireless application on your wireless device. Visit https://www.danby.com/support/#apps to download the application and learn about its operation. -
TIMER
The timer can be used to turn the appliance on or off after a set period of time. The control panel has one timer button. Press once to set the auto off timer and twice to set the auto off timer. The remote control has separate timer on and timer off buttons. -
Auto On Timer
-
Press the timer on button on the remote or press the timer button on the control panel twice.
-
Use the temperature control buttons to select the desired amount of time before the appliance should turn on.
-
Use the mode button to select the desired mode.
-
Use the fan button to select the desired fan speed.
-
The time selected will appear on the display panel and will count down until the appliance turns on.
-
Auto Off Timer
-
Press the timer off button on the remote or press the timer button on the control panel once.
-
Use the temperature control buttons to select the desired amount of time before the appliance should turn off. The appliance will run in the currently selected mode.
-
The time selected will appear on the display panel and will count down until the appliance turns off.
Using On and Off Timers Simultaneously
The on and off timers can be used at the same time. To set the appliance to
turn on, run for a set period of time and then turn off, set the auto on timer
fi rst and then set the auto off timer. To set the appliance to run for a
period of time, turn off for a period of time and then turn back on, set the
auto off timer fi rst and then set the auto on timer. Both indicator lights
will illuminate and the display will count down to the appliance either
turning off or on, whichever function was set fi rst. The timer will not cycle
the appliance on and off indefi nitely. The on and off timers will function one
time and then the appliance will return to regular functioning. Turning the
appliance off or unplugging the appliance will clear all memory settings,
including the timer.
AIR FILTER
The air fi lter should be cleaned approximately every 2 weeks. The air filter
may require more frequent cleaning if there is signifi cant dander or fur in
the air.
Approximately every two weeks, the fi lter indicator light on the control panel
will illuminate as a reminder to clean the filter. Follow the steps below to
clean the fi lter and return the appliance to normal functioning.
- The air filter is located behind the front intake grill. To remove the air filter, grasp the grille on both sides and gently pull forward and then remove the fi lter.
- Use a vacuum cleaner with a soft brush attachment to remove any large debris or dust build-up from the air fi lter.
- Wash the fi filter in lukewarm, soapy water, below 40°C (104°F), or use a neutral cleaning agent.
- Rinse the filter with clean water and dry thoroughly before reinstalling in the appliance.
- Press the filter button on the control panel to resume normal functioning.
Note: Do not operate the appliance without the air fi lter installed.
ERROR CODES
If the display panel shows any of the below error codes, unplug the appliance,
let it stand for 5-10 minutes and then plug it back in. If the error persists,
call for service.
- AS – Ambient temperature sensor error
- ES – Evaporator temperature sensor error
- E4 – Display board communication error
- Lo – Room temperature is lower than 0°C (32°F) HI – Room temperature is higher than 37°C (99°F)
CLEANING
To avoid possible electric shock, ensure that the appliance is unplugged
before performing any cleaning or maintenance.
The outside of the appliance can be wiped clean with a soft cloth or with a
lukewarm, damp cloth if necessary.
Do not use gasoline, benzene, thinner or any other chemicals to clean this
appliance as these substances can cause damage to the fi nish and deformation
of plastic parts.
Never pour water directly onto the appliance as this will cause deterioration
of electrical components and wiring insulation.
END OF SEASON CARE
Before removing the appliance from service for the year, operate the appliance
on high fan mode for half a day to ensure the inside of the appliance
is dry. This will help avoid the growth of mold or mildew inside the
appliance. Ensure the fi lter is clean and dry. Store the appliance covered in
a dry location.
Note: When installing or removing the appliance from the window, ensure that
caution is taken to prevent it from falling backward. It is recommended that
installation or removal is completed with assistance to prevent injury to
persons or damage to property or the appliance.
DISPOSAL
Check for local regulatory compliance regarding approved and safe disposal of
this appliance.
FREQUENTLY ASKED QUESTIONS
Can I leave my AC in place through the winter?
This is not recommended. Please bring your AC unit indoors during the winter
months.
What are the standard wattage and amps used?
Information pertaining to watts and amps can be found on the rating plate
located on the side of the unit.
When should I use the exhaust hose?
The exhaust should be used in cool, dry and heat modes. It is not required in
fan mode.
Can I use an extension cord?
No, an extension cord may not be used.
Is there supposed to be Styrofoam in the unit?
The Styrofoam that is inside the unit acts as insulation. Do not remove it.
Only remove loose packaging.
Why do I hear water in the unit?
Water is collected during the air conditioning process. This water will drain
out of the unit and onto the ground and is why the unit should be installed on
a slight downward tilt.
How much does it cost to run the unit?
Please refer to the energy guide on the front of the appliance or at
www.Danby.com.
Odors
Odour is caused by the formation of mold or mildew on internal surfaces. This
can happen when there is poor air circulation, a dirty fi lter or the air
conditioner was not used for a period of time.
- Ensure the fi lter is clean.
- Run the unit on fan mode to remove any internal moisture.
- Check for any blockages in the drain lines and ensure there are no obstructions.
Please give your unit a hard reboot. Unplug it and plug it back in after 15-20
minutes. This allows the unit to warm and drain if there is any frost stopping
draining and go back to factory settings
For odour in a unit, we suggest using an algaecide tablet. You fi rst need to
turn the unit off, remove the lower grill and fi lter from the grill at the
base of the unit, and then place the tablet in base.
TROUBLESHOOTING
The appliance will not operate
- Plug is not fully inserted into the wall outlet
- Blown fuse or circuit breaker
Insuffi cient cooling
- Air fi lter is dirty
- Blocked air fl ow
- Appliance size is too small for application
Noise
- Inadequate support in window installation; double-check that all screws are tight and the installation is securE
Water dripping inside
- The appliance is not properly angled to allow water to drain to the outside
Water dripping outside
- On very hot or humid days dripping water from the back of the appliance is normal
Frost build-up
- When outdoor temperatures are below 18.3°C (65°F) frost may form when the appliance is in cooling mode
- Switch the appliance to fan-only mode until the frost melts
References
- Danby® the Appliance Specialists | Canada
- Danby® the Appliance Specialists | Canada
- Customer Support | Danby Canada
- Product Registration | Danby Canada
- Danby® the Appliance Specialists | Canada
- Customer Support | Danby Canada
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>