FERM EBM1004P Corded Electric Blower Instruction Manual

June 5, 2024
FERM

FERM EBM1004P Corded Electric Blower

ELECTRIC DUST BLOWER EBM1004P

Thank you for buying this FERM product. By doing so you now have an excellent product, delivered by one of Europe’s leading suppliers. All products delivered to you by Ferm are manufactured according to the highest standards of performance and safety. As part of our philosophy we also provide an excellent customer service, backed by our comprehensive warranty. We hope you will enjoy using this product for many years to come.

SAFETY INSTRUCTIONS

Read the enclosed safety warnings, the additional safety warnings and the instructions. Failure to follow the safety warnings and the instructions may result in electric shock, fire and/or serious injury. Save the safety warnings and the instructions for future reference.

The following symbols are used in the user manual or on the product:

| Read the user manual.
---|---
| Do not use in wet conditions or expose it to rain.
| Always wear eye protection!
| Wear hearing protection.
| Risk of flying objects. Keep bystanders away from the work area.
| Do not touch the fan. The fan blades will continue to rotate for a short time after machine is switched off.
| Risk of electric shock
| Class II machine – Double insulation – You don’t need an earthed plug.
| The product is in accordance with the applicable safety standards in the European directives.

Additional safety instructions for blowers

  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

  • Children should be supervised to ensure that they do not play with the appliance.

  • This tool is intended for household use only.

  • Only use attachments recommended in this manual.

  • Keep ventilation openings free of anything that may reduce the air flow.

  • Do not use to pick up anything that is burning
    or smoking, such as cigarettes, matches, freshly cut metal shavings or hot ashes.

  • Do not use to pick up flammable or combustible liquids such as gasoline or use in areas where they may be present.

  • Do not use without dust container or and filter in place.

  • Do not use outdoors or on wet surfaces.

  • Use extra care when using on stairs.

  • Always use protective goggles, a cap and mask when using the blower.

  • Never point the nozzle at anyone in the vicinity when using the blower.

  • Always use the dust bag when collecting dust, chips and the like.

  • Never operate the appliance while people, especially children, or pets are nearby.

  • Do not wear loose clothing or jewellery that can be drawn into the air inlet. Keep long hair away from the air inlets.

  • Before using, check the supply and extension cord for signs of damage and aging.

  • Do not use the appliance if the cord is damaged or worn.

  • If a cord becomes damaged during use, disconnect the supply cord from the mains immediately. DO NOT TOUCH THE CORD BEFORE DISCONNECTING THE SUPPLY.

  • Do not carry the appliance by the cable.

  • Keep all nuts, bolts and screws tight to be sure the appliance is in safe working condition.

  • Disconnect the appliance from the mains supply · whenever you leave the machine;

  • before clearing a blockage;

  • before checking, cleaning or working on the appliance;

  • if the appliance starts to vibrate abnormally.

  • Check the dust bag frequently for wear or deterioration.

  • Replace worn or damaged parts.

  • Use only genuine replacement parts and accessories

  • Store the appliance only in a dry place.

Electrical safety

Warning! When using electric tools, basic safety precautions should always be followed to reduce the risk of fire, electric shock and personal injury. Read all these instructions before attempting to operate this product and save these instructions.

| Always check that the power supply corresponds to the voltage on the rating plate.
---|---
| The machine is double insulated in accordance with EN60745; therefore no earth wire is required.

Replacing cables or plugs

If the replacement of the supply cord is necessary, this has to be done by the manufacturer or his agent in order to avoid a safety hazard.

Using extension cables

Only use an approved extension cable suitable for the power input of the machine. The minimum conductor size is 1.5 mm2 . When using a cable reel always unwind the reel completely.

MACHINE INFORMATION

Intended use

The blower has been design for blowing & cleaning applications as well as for light suction purposes.

Technical specifications
Voltage 220 – 240 V~
Frequency 50 Hz
Power input 600 W
No load speed 0-13.900/min
Max. air speed 4.1 m3 /s
Nozzle diameter 30 mm
Sound pressure (Lpa) 82.1 dB(A) k=2.5 dB(A)
Sound power (Lwa) 95 dB(A) k=2.5 dB(A)
Vibration 2.994 m/s2 k=1.5 m/s2
Vibration level

The vibration emission level stated in this instruction manual has been measured in accordance with a standardised test given in EN 60335; it may be used to compare one tool with another and as a preliminary assessment of exposure to vibration when using the tool for the applications mentioned
– using the tool for different applications, or with different or poorly maintainted accessories, may significantly increase the exposure level
– the times when the tool is switched off or when it is running but not actually doing the job, may significantly reduce the exposure level

Replacing cables or plugs If the replacement of the supply cord is necessary, this has to be done by the manufacturer or his agent in order to avoid a safety hazard.

Protect yourself against the effects of vibration by maintaining the tool and its accessories, keeping your hands warm, and organizing your work patterns

Description

The numbers in the text refer to the diagrams down below.

1. Outlet
2. On/Off Switch
3. Lock-on button
4. Suction port
5. Nozzle
5a.Nozzle extension piece
6. Dust bag
8. Variable speed wheel

OPERATING

| Before adding or removing the nozzle from the machine, first remove the power plug from the wall socket.
---|---

Mounting accessories

Dust blower function
Fig. A + B

  • Attach the nozzle (5) to the outlet (1).
  • Turn the nozzle (5) clockwise to lock it in place.

Dust suction function
Fig. A + C

  • Attach the nozzle (5) to the suction port (4).
  • Attach the dustbag (6) to the outlet (1).

After use, always empty the contents of the dust bag in a dust bin. Open the zipper to release the dust from the dust bag.

Operation

The On/Off switch
Fig. A

  • Switch the machine on by pressing the On/Off swtich (2).
  • Releasing the On/Off switch (2) will turn the machine off again.

Switch-lock
Fig. A

  • Lock the On/Off switch by pressing the On/Off switch (2) and then pressing the lock-on button (3).
  • Release the switch lock again by pressing the On/Off switch (2) shortly.

Adjusting the air speed
Fig. A
The air speed can be adjusted by the dial wheel.

  • To increase the air speed turn the variable speed wheel (8) up (to higher number)
  • To decrease the air speed turn the variable speed wheel (8) down (to lower number)

MAINTENANCE

| Before cleaning and maintenance, always switch off the machine and remove the mains plug from the mains.
---|---

Clean the machine casings regularly with a soft cloth, preferably after each use. Make sure that the ventilation openings are free of dust and dirt. Remove very persistent dirt using a soft cloth moistened with soapsuds. Do not use any solvents such as gasoline, alcohol, ammonia, etc. Chemicals such as these will damage the synthetic components.

Replace power cords

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.

ENVIRONMENT

Faulty and/or discarded electrical or electronic apparatus have to be collected at the appropriate recycling locations

Only for EC countries
Do not dispose of power tools into domestic waste. According to the European Guideline 2012/19/EC for Waste Electrical and Electronic Equipment and its implementation into national right, power tools that are no longer usable must be collected separately and disposed of in an environmentally friendly way

WARRANTY

The warranty conditions can be found on the separately enclosed warranty card.

The product and the user manual are subject to change. Specifications can be changed without further notice.

Spare parts list

Article no. Description Position no.
480375 Left fan cover 1
480376 Screw M5 2
480377 Washer Ø14155,2 3
480378 Fan 4
480379 Screw ST4*35 5
480380 Right fan cover 6
480381 Flat washer Ø145,21 7
480382 Bearing 609RS 8
480383 Flat washer Ø189,21 9
480384 Screw ST4*40 10
480385 Stator 11
480386 Rotor 12
480387 Insulation ring 13
480388 Bearing 608RS 14
480389 Left handle cover 15
480390 cable sheath 16
480391 Cable 17
480392 Switch 18
480393 Screw ST4*16 19
480394 Tension disc 20
480395 Carbon brush cap (2pcs) 21
480396 Carbon brush (2pcs) 22
480397 Carbon brush holder (2psc) 23
480398 Spring (2pcs) 24
480399 Right housing part 25
480400 Blow tube 26
480401 Dust bag 27

DECLARATION OF CONFORMITY EBM1004P – ELECTRIC DUST BLOWER

We declare under our sole responsibility that this product is in conformity with
directive 2011/65/EU of the European parliament and of the council of 8 June on the restriction of the use of certain hazardous substances in electrical and electronic equipment is in conformity and accordance with the following standards and regulations:

EN 62233, EN 55014-1, EN 55014-2, EN 61000-3-2, EN 61000-3-3
EN 60335-1, EN 60335-2-100

2014/35/EU, 2011/65/EU, 2012/19/EU, 2014/30/EU

Zwolle, 01-02-2021
H.G.F. Rosberg
CEO FERM

FERM – Lingenstraat 6 – 8028 PM – Zwolle – The Netherlands

Documents / Resources

| FERM EBM1004P Corded Electric Blower [pdf] Instruction Manual
EBM1004P, Corded Electric Blower, EBM1004P Corded Electric Blower
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

FERM User Manuals

Related Manuals