COMPCOOLER COMP-UICS-7430 Univest Ice Water Cooling System User Manual
- June 5, 2024
- COMPCOOLER
Table of Contents
- COMPCOOLER Introduction:
- Product Categories
- BACKGROUND OF PERSONAL COOLING SYSTEM
- COMPCOOLER Personal ICE Water Circulation Cooling System (PICS)
- Description:
- Components List
- Optional Components
- Operation Processes
- Safety:
- Warranty:
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Univest ICE Water Cooling System
Model: COMP-UICS-7430
Rev. B
Operation Manual
Compcooler Technology
Jan. 2021
COMPCOOLER Introduction:
Compcooler Technology specializes in working on personal cooling & heating systems for harsh conditions. Compcooler has established its resume as a manufacturer for Military, Electronic, and Medical cooling equipment. The employees at Compcooler’s state-of-the-art manufacturing facility have been producing liquid heating & cooling systems for over 15 years. Quality system: ISO9001 and AS9100 registered facility. Certifications for major items: CE, FCC, UL, PSE, CB, FDA.
Product Categories
- Personal ICE Water Circulation Systems
- Micro Refrigeration Chiller Units
- Liquid Heating & Cooling Chiller
- Liquid Cooling & Heating Garment
- Industrial Chiller Unit Module
- Customized Cooling Systems
Certifications for major items
Quality System for facility
BACKGROUND OF PERSONAL COOLING SYSTEM
In conditions of extreme heat, people may be at risk of heat stress where the body is under stress from overheating. Heat stress is not only a serious condition for workers, but it can result in occupational illnesses and injuries, heat-related discomforts, and illnesses include heat exhaustion, heat cramps, heat rash, or even heat stroke. Symptoms can range from profuse sweating to dizziness, cessation of sweating, and collapse. At greatest risk of heat stroke are the elderly, children, and people with medical conditions, however, even young and healthy individuals can succumb to heat if they participate in strenuous physical activities during hot weather. It will need immediate action to cool the person until help arrives.
LIQUID CIRCULATION COOLING SYSTEM
A liquid circulation cooling system is an active cooling solution, it can cool the body temperature fast to decrease the incidence of thermal stress and heat stroke while increasing comfort, safety, focus, and endurance. A liquid circulation system includes a liquid circulation unit and a cooling garment. Mini a pump circulates cold water from the chiller or ICE bladder to cooling channels embedded on the cooling garment and continuously flows around the body, it will keep the user’s body temperature at a comfortable and safe range.
BENEFITS OF LIQUID COOLING SYSTEM
Reduction in body core temperature increased duration. Reduction in skin
temperature, decrease in hydration need Reduction in heart rate, improve
mental acuity Reduction in sweat rate, maintain physical performance
COMPCOOLER Personal ICE Water Circulation Cooling System (PICS)
PICS includes a liquid circulation unit and liquid cooling garment. A mini pump circulates the cold ICE water from the bladder to a micro-tubing cooling channel embedded on the liner of the garment, it continuously flows around the body to reduce body core temperature and keep the user at a comfortable cool range in hot conditions.
Detachable Bladder: 1.5L, 2.0L, 3.0L and 4.0L (Hydration) Cooler Unit: 6L, 25L
Cooler
Pump Control Unit: ON/OFF mode: cold water circulation only Flow control mode:
3 levels of water flow control Temp control mode: precise temp control for
circulation of liquid
Liquid Temperature range: 2°C-10°C (36 °F -50 °F ) Cooling time:
1-3 hours for 1.5L frozen bladder
3-6 hours for 3.0L frozen bladder
4-8 hours for a 6L ICE Cooler
8-12 hours for 25L ICE Cooler
Operation Ambient: 2°C-65°C (36 °F -148 °F )
Univest ICE Water Cooling System
Model: COMP-UICS-7430
Description:
Compcooler Univest ICE Water Cooling System (UICS) combines an ICE water circulation unit and liquid cooling vest as one item, this significant improvement provides better wearability for end users. UIC includes 3L quick- release bladder, mini water pump, rechargeable battery, and Univest. A mini pump circulates cold water from the bladder to the micro tubing cooling channel embedded on the mesh liner, and continuously flows around the body, it keeps the user cool and comfortable in hot conditions. Waterproof and breathable outer fabric, interlayer 3D material, reduce the weight loading, stretch soft mesh liner, better skin touch feeling, ergonomic vest design, comfort to wear, easy don. University was designed for outwear application?
Components List
Item | Description | Quantity |
---|---|---|
1 | Univest Cooling System | 1 |
2 | Mini water pump | 1 |
3 | Battery 7.4V 2200mAh | 1 |
4 | 3.0L Bladder | 1 |
5 | Manual | 1 |
Univest ICE Water Cooling System (On/Off Mode)
Model: COMP-UICS-7430BG
University Material:
Outer Fabric: 320T Nylon Taslon
Waterproof 5000WR
Breathable 3000MVP
Color: Beige
Interlayer: 3D fabric
Liner: Soft mesh with Micro-tubing cooling channel
Adjustable device: Stretch strap with Velcro
Color: Black and beige
Cooling Channel: Silicon Tubing
Zipper: YKK
ICE Water Circulation System
Interior Backpack: Reflective Insulation
Bladder: 3.0L quick-release bladder
Pump: 7.4V diaphragm pump
Connector: quick fitting
Switch: ON/OFF
Zipper: Waterproof zipper
Battery: 7.4V 2200mAh rechargeable Li-Ion battery
Noise: 45dBA
Dry weight: 1KG
University Performance:
Cooling time: 2-4 hours by 3.0L frozen bladder,
1-3 hours by Ice cubes
Circulation: 500ml/min
Temperature Range: 46℉-68℉
Battery-Operated: 8 hours
Operation Ambient: 0℃-60℃ (32℉-140℉)
Garment Size:
Item | XS/S | M/L | XL/XXL | 3XL/4XL |
---|---|---|---|---|
Chest | 84cm/33.1” | 100cm/39.4” | 108cm/42.5” | 126cm/49.6” |
Length | 64cm/25.2” | 68cm/26.8” | 70cm/27.6” | 73cm/28.8” |
Note: Garment size has 15% expansion stretch (max 15cm/6”) by adjustable device
Optional Components
-
Pump unit
Flow control mode, 3 levels pump control
Level I 200ml/min
Level II 350ml/min
Level III 500ml/min -
Battery
7.4V 5A Rechargeable battery
Univest ICE Water Cooling System (On/Off Mode)
Model: COMP-UICS-7430BK
Black Univest ICE Water Cooling System
Univest ICE Water Cooling System (Flow Control Mode)
Model: COMP-UICS-7430BK-FC
Black Univest ICE Water Cooling System (Flow Control)
Model: COMP-UICS-7430BG-FC Beige Univest ICE Water Cooling System (Flow Control)
Flow Control Pump Unit
3 levels of water flow control
Fire Resistant Univest ICE Water Cooling System (On/Off Mode)
Model: COMP-UICS-7430-FR
High Visible Univest ICE Water Cooling System (On/Off Mode)
Model: COMP-UICS-7430-HV
Operation Processes
Preparation and Unit Checking
-
Battery Charging
Full Charge of battery, LED light of charger change from RED to GREEN
TIPS: press “Remaining Battery Capacity” on the battery, 3 Led lights mean 80-100%, 2 lights mean 60-80%, and 1 light means 50% less. -
Bladder Connection:
Fill water into Roll-Top, connect the bladder Outlet/Inlet with Univest Checking: bladder no leaks, quick fittings connection is fine, once you hear a click, it’s in position. Checking: Vest no leaks, quick fittings connection is fine. -
Start circulation:
Press the On/Off switch, Pump circulates water from the bladder into micro tubing cooling channels of Univest, then flows back to the bladder. Users may see the water flow back to the bladder from the Inlet fitting.
Checking: Battery works fine, and the pump works fine. -
Bladder Freeze:
Step I- Freeze Bladder: Fill water into ROLL TOP. Water must be below FILL LINE to create an air pocket.
Step II-After the bladder is frozen, fill a small amount of circulation water into the roll top.
Step III-Connect ICE bladder to cooling unit, Outlet, and Inlet.
Step IV-Start circulation with the ON/OFF switch or Temp controller.
ICE Cubes option:
For instant use, fill ICE cubes with small amount of water into Roll Top. (ICE cubes may melt faster than frozen bladder.)
Operation step I
-
Bladder connection:
Fill a small amount of circulation water into the roll-top for quick operation Connect the bladder with Univest by quick fittings
Tips: if the bladder was not laid flat or not created an air pocket in the fridge, quick fittings are possible to be frozen, please be patient for fitting melt or unfreeze quick fittings by tap water. -
Battery connection
Connect the battery with the pump unit by 4017 plugs.
Operation Step II
-
Put on Univest:
adjust the side body fit device and make sure the cooling channel contacts your skin.
Tips: The user may adjust the size to a comfortable range and get better cooling performance. -
Start cooling
Users may press the On/Off switch to start cold water circulation or stop circulation. -
Extend cooling time
Users may replace the frozen bladder to extend the cooling time.
Users may fill in ICE cubes for quick cooling operation.
Clean and Maintenance
- Univest:
Users may use wet clothing to clean the Univest exterior dirty directly. Prefer to clean by hand wash then hang dry. Machine wash: wash Univest using a front-loading wash machine with cold water on a gentle/delicate cycle.
Note: DO NOT BLEACH, NO IRON, NO DRYER, TUMBLE DRY ON LOW
Components Renewal
- Battery: the user may purchase an extra replacement battery or a 7.4V 5A battery.
- Bladder: the user may purchase more extra bladders to extend cooling time.
- Pump: the user may purchase a flow control pump unit to replace the On/Off pump unit.
Storage:
Unit Storage
Please empty the circulation water from the circulation system and vest before storage.
-
Bladder empty: disconnect the bladder from Univest, and empty the liquid.
-
Vest empty: connect the empty bladder with Univest, lean or upside down, and press On/Off to restart circulation, the pump will push the water inside the cooling channel and return to the bladder,
Tips: make sure no water re-circulation from the bladder to the vest. -
Unit dry: please hang dry the bladder and unit more than 10 hours before storage.
-
Restart system: after long-term storage, please fill in clean water and run the unit for more than 10 minutes to the reactive pump.
Battery Storage
- Shall be in the clean and dry ventilation room at temperature 0℃-35℃ (32℉-95℉)
- Shall keep out of fire or heat and avoid touching corrosion elements
- Shall be charged every 6 months during storage
- Keep the battery out of children’s reach
Please STOP using the battery if any abnormal is found!
Safety:
It is important to become thoroughly familiar with the manual and operating characteristics of the unit. It is the owner’s responsibility to assure proper operator training, installation, operation and maintenance of the unit. Observe all warnings can result in injury to the operator and severe mechanical damage to the unit.
Warranty:
Compcooler Warrants to the Original Purchaser that products sold shall be free
from defects material and workmanship for warranty period not exceed one year
from the date
of shipment. Compcooler agrees to correct the original user of this product,
either by repair or at the manufacturer’s election by replacement. This
warranty shall not apply if the defect or malfunction was caused by accident,
neglect, unreasonable use, improper service, or other causes not arising out
of defects in material or workmanship. The manufacturer’s sole obligation
under this warranty is limited to the repair or replacement of a defective
product and shall not, in any event, be liable for any incidental or
consequential damages of any kind resulting from the use or possession of this
product.
Personal Thermal Technology,
Keep your body cool and comfortable in harsh conditions!
COMPCOOLER, PERSONAL THERMAL TECHNOLOGY
www.compcooler.com
info@compcooler.com
IS09001 AS9100 Certified Facility