KLARSTEIN 10034680 Metrobreeze New York 7K Air Conditioner Instruction Manual

June 5, 2024
Klarstein

KLARSTEIN 10034680 Metrobreeze New York 7K Air Conditioner

KLARSTEIN 10034680 Metrobreeze New York 7K Air Conditioner-
fig1

Dear Customer,
Congratulations on purchasing this device. Please read the following instructions carefully and follow them to prevent possible damages. We assume no liability for damage caused by disregard of the instructions and improper use. Scan the QR code to get access to the latest user manual and more product information.

TECHNICAL DATA

Item number 10034680, 10034681
Power supply 220-240 V ~ 50/60 Hz

NOTES ON REFRIGERANT R290

Warnings

  • The air conditioning system must be kept and transported upright. Otherwise, irreparable compressor damage may occur. Leave the unit for at least 24 hours before putting it into operation.
  • Switch off the device and disconnect it from the power supply before cleaning.
  • Make sure that the product creates a steady stream of air. Ensure the air inlets and outlets are not blocked.
  • To prevent leaks, operate this unit on a horizontal surface.
  • Any person performing work on a refrigerant circuit should have a current certificate from an industry-accredited assessment body. This ensures competence for the safe handling of refrigerants according to an industry-recognized assessment specification.
  • If the device stops working, dispose of it properly.
  • Store the device in a well-ventilated place when not in use.
  • Store the device so that it is not damaged.
  • Repairs may only be carried out by the manufacturer or authorized specialist company.
  • Do not damage any components of the refrigerant circuit. Escaping refrigerant may not be noticed because it is odourless.
  • Maintenance and repairs must be carried out under the supervision of specialists in the use of flammable refrigerants.

Information for rooms with refrigerant pipes

  • Limit the piping to a minimum.
  • Be careful not to damage the piping.
  • Appliances with flammable refrigerants may only be installed in a well-ventilated room.
  • Comply with national gas regulations.
  • All mechanical connections must be freely accessible for maintenance purposes.
    CAUTION
    Risk of fire! This device contains the flammable refrigerant R290. If the refrigerant escapes and is exposed to an external ignition source, there is a risk of fire.

SAFETY INSTRUCTIONS

Special notes

  • Only use agents recommended by the manufacturer for defrosting or cleaning.
  • Never store the appliance in a room in which there are permanent sources of ignition (e.g. open flames, a switched on gas appliance or a switched on electric heater).
  • Do not puncture or burn the appliance.
  • Note that coolant may be odorless.
    Note: Only use the unit in rooms larger than X m² (see table):Model| X (m²)
    ---|---
    5000 BTU/h, 7000 BTU/h, 8000 BTU/h| 4 m²
    9000 BTU/h, 10000 BTU/h, 10500 BTU/h| 12 m²
    12000 BTU/h, 14000 BTU/h, 16000 BTU/h,18000 BTU/h| 15 m²

General safety instructions

  • The device is only suitable for indoor use.
  • Do not use the product if it needs to be repaired or if it has not been installed properly.
  • Do not use the product in the following areas:
    • near heat sources,
    • in areas where oil can splash,
    • in areas exposed to direct sunlight,
    • in areas where splash water can occur,
    • near bathtubs, in washrooms, near showers or swimming pools.
  • Never insert your fingers or other objects into the ventilation openings. In particular, warn children of the dangers this may cause.
  • Ensure that the unit is held vertically during transport and storage so that the compressor is correctly positioned.
  • Always turn off the appliance before cleaning and unplug it from the wall outlet.
  • Switch off the appliance before moving it and unplug it from the wall outlet. Move the appliance slowly and carefully.
  • To avoid the risk of fi re, do not cover the unit.
  • All fan connections must comply with local electrical safety regulations. If necessary, refer to these regulations.
  • Supervise children so that they do not play with the unit.
  • If the power cord is damaged, it must be replaced by the manufacturer, customer service or a similarly qualifi ed person to avoid danger.
  • This equipment may be used by children over the age of 8 and by persons (including children) with limited physical, sensory or mental capabilities and/or lack of experience and knowledge, provided they have been instructed in the use of this equipment by a person responsible for their safety and understand the hazards associated with the use of this equipment. Cleaning and maintenance of the appliance may only be carried out by children under supervision.
  • The appliance must be installed in accordance with national wiring regulations.
  • Type and voltage of fuses: T, 250 V AC, 2 A or higher.
  • Contact customer service for cleaning and maintenance.
  • Do not pull the power cord, deform or modify it, or immerse it in water. Incorrect handling of the power cord may result in damage to the equipment and/or electric shock.
  • National gas regulations must be observed.
  • Do not block the ventilation openings.
  • Do not operate the appliance solely by inserting or removing the power plug, as this may result in electric shock or fi re due to heat.
  • Immediately unplug the appliance from the wall outlet if it emits strange noises, odours or smoke.

Instructions for Handling Damage

  • In case of damage to the device, contact the manufacturer, the customer service or a similarly qualifi ed person.
  • If damage occurs, turn off the power, unplug the power cord, and contact the manufacturer, the service representative, or a similarly qualifi ed person.
  • The power cord must be securely earthed.
  • If the power cord is damaged, turn off the power to avoid danger and unplug the power cord from the wall outlet. The power cord must be replaced by the manufacturer, customer service or a similarly qualifi ed person.
    WARNING
    Risk of injury! Repairs to the coolant circuit may only be carried out by trained specialist personnel. Never attempt to repair the unit yourself!

DEVICE OVERVIEW

KLARSTEIN 10034680 Metrobreeze New York 7K Air Conditioner-
fig3

CONTROL PANEL AND REMOTE CONTROL

KLARSTEIN 10034680 Metrobreeze New York 7K Air Conditioner-
fig4

1 ON/OFF Switch device on/off.
2 ****

MODE

| Press several times to select cooling, wind or

dehumidification.


3

| ****

ARROW KEYS

| In cooling mode, press to increase/decrease temperature. In Timer mode, press to set the time for the on/off timer.

Press both buttons simultaneously to toggle between

°C/°F.

4| SPEED| Press repeatedly to set the fan speed (high/low).
5| ****

TIMER

| In standby mode, press to set the power-on timer time. When the power is on, press to set the power-off timer time.
6| DISPLAY| Displays the set temperature/time.
7| RECEIVER| Receives the signal from the remote control.
8| °C/°F| Press button to toggle between °C/°F.
9| SLEEP| In cooling mode, press to activate sleep mode.

HOW TO INSTALL THE WINDOW SEAL

Installing the window sealing is easy. You can attach it to a tilted window or to a laterally opened window. Our demonstration is performed on a laterally opened window. It is especially suitable for low positions of the exhaust pipe. The velcro tape must be attached on three sides. Leave out the side with the window being connected to the frame. Clean the frame and dry it first, so that the tape sticks.

KLARSTEIN 10034680 Metrobreeze New York 7K Air Conditioner-
fig5

INSTALLATION

OPERATION AND MODES

  • Cooling mode
    • When the air conditioner is in COOL mode or the cooling mode is selected after switching on, the COOL indicator light lights up.
    • Press the ARROW KEYS to set the desired temperature between 16-30 °C. The temperature will be set between 16-30 °C and the temperature will be set between 16- 30 °C.
    • Press the SPEED button to set the speed (high/low).
  • Fan mode
    • When the air conditioner is in FAN mode or the fan mode is selected after turning on, the fan indicator light FAN lights up.
    • Press the SPEED button to set the speed (high/low).
    • The temperature cannot be set in this mode.
  • **Dehumidification mode

**

  * If the room temperature exceeds 17°C (62°F) after entering dehumidification mode, the compressor is turned on.
  * If the room temperature drops below 59°F (15°C), the compressor is turned off.
  * When the room temperature returns to above 17°C, the compressor restarts.  

In dehumidification mode, the fan runs at low speed by default. Wind speed and temperature cannot be adjusted. The temperature cannot be adjusted.
Note: When using the dehumidification function, be sure to attach the one water hose (not included) for permanent drainage. Otherwise, the dehumidification performance will deteriorate and the alarm [FL] will appear as soon as the collection container is full.

  • Sleep mode
    • Press the SLEEP button on the remote control or press and hold both arrow buttons on the control panel to switch to sleep mode.
    • In sleep mode, the fan runs at low speed and cannot be adjusted.
    • When you press the SPEED button in sleep mode, [SL] appears on the screen.
  • Timer mode
    • In standby mode, press the TIMER button to set the power on timer. Press the arrow buttons to set the time (0-24 hours). The set time is shown in the display.
    • When the power is on, press the TIMER button to set the off timer. Press the arrow keys to set the time (0-24 hours). The set time is shown in the display.
  • Drainage method
    This product is equipped with an automatic water evaporation system. The condenser is cooled with the circulation water to improve cooling performance and save energy.

CLEANING AND CARE

  • Switch off the appliance before cleaning and unplug the appliance from the wall outlet.
  • Do not use gasoline or other chemicals to clean the product.
  • Do not wash the appliance directly.
  • If the unit is damaged, contact customer service.

Cleaning the air filter

  • The air filter can be blocked by dust/protection and should be cleaned once every two weeks.
  • Open the ventilation grille and remove the air filter.
  • Clean the air filter with a neutral detergent and lukewarm water. Then dry the filter in the shade.
  • Replace the air filter and all other components.

If the appliance will not be used for a long time

  • Remove the plug from the drain and install the supplied water hose. Place the other end of the water hose in a bucket or drain. Replace the plug.
  • Run the appliance in fan mode (FAN) for 2 hours until the inside is dry.
  • Turn off the unit and unplug it from the wall outlet.
  • Wash and reassemble the filter strainer.
  • Remove the exhaust air duct and stow it in a dry place.
  • Cover the unit with a plastic bag and store in a dry place.

TROUBLESHOOTING

Problem Possible cause Suggested solution
The device is not running. The plug has not been

plugged in.

| Insert the plug.
The display shows FL.| Drain the water and then restart the appliance.
The timer has expired.| Wait 3 minutes and then

restart the appliance.

The unit goes off and on

all the time.

| The unit is in direct sunlight.| Close the curtain.
Doors and windows are open. There are heat sources in the room.| Close doors and windows and remove heat sources.
The filter is dirty.| Clean the filter.
The air inlets or outlets are

blocked.

| Clean the air inlets or outlets.
The unit makes loud

noises.

| The unit is not level.| Place the unit on a level surface.
The compressor is not

running.

| The unit has just been

switched off.

| Wait 3 minutes and then

restart the unit.

Error codes

E1| The evaporator coil sensor is

broken.

| Have the sensor replaced by a specialist company.
---|---|---
E2| The room temperature sensor

is broken.

| Have the sensor replaced by a specialist company.
E4| Frost protection: The coil temperature is too low and the entire air conditioning system is switched off.| If the temperature rises above 8 °C again, the protection is deactivated and the previous operating state is automatically restored.

PRODUCT DATA SHEET

Information according to regulation (EU) No. 626/2011

Information according to regulation (EU) No. 206/2012

Model identifier(s) 10034680, 10034681
Description Symbol
Rated capacity for cooling Prated for cooling
Rated capacity for heating Prated for heating
Rated power input for cooling PEER
Rated power input for heating PCOP
Rated Energy efficiency ratio EERd
Rated Coefficient of performance COPd
Power consumption in thermostat-off mode PTO
Power consumption in standby mode PSB

Electricity consumption of single/double

duct appliances

(indicate for cooling and heating separately)

| DD: QDD SD: QSD|

0,8

| DD: kWh/a SD: kWh/h
Sound power level| L WA| 62| dB(A)
Global warming potential| GWP| 3| kgCO2 eq.
Contact details

for obtaining more information

| Chal-Tec GmbH,

Wallstraße 16, 10179 Berlin, Germany.

DISPOSAL CONSIDERATIONS

If there is a legal regulation for the disposal of electrical and electronic devices in your country, this symbol on the product or on the packaging indicates that this product must not be disposed of with household waste. Instead, it must be taken to a collection point for the recycling of electrical and electronic equipment. By disposing of it in accordance with the rules, you are protecting the environment and the health of your fellow human beings from negative consequences. For information about the recycling and disposal of this product, please contact your local authority or your household waste disposal service. This product contains batteries. If there is a legal regulation for the disposal of batteries in your country, the batteries must not be disposed of with household waste. Find out about local regulations for disposing of batteries. By disposing of them in accordance with the rules, you are protecting the environment and the health of your fellow human beings from negative consequences.

MANUFACTURER & IMPORTER (UK)

Manufacturer:
Chal-Tec GmbH, Wallstrasse 16, 10179 Berlin, Germany.

Importer for Great Britain:
Chal-Tec UK limited
Unit 6 Riverside Business Centre
Brighton Road
Shoreham-by-Sea
BN43 6RE
United Kingdom

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals