ECOR PRO LD800 80 Litre Compressor Dehumidifier Instruction Manual

June 5, 2024
ECOR PRO

ECOR PRO LD800 80 Litre Compressor Dehumidifier
LOGO

ECOR PRO LD800 80 Litre Compressor Dehumidifier

ECOR PRO LD800 80 Litre Compressor Dehumidifier
PRODUCTTHANK YOU
Dear Sir, Madam,
Congratulations on purchasing your ECOR PRO LD800.
A true investment and asset for any home. In addition to dehumidification, the LD800 can provide fresh air to the living environment as well as keeping the energy in your home. Even the power used in the LD800 is put back into the home. Unique heat recovery system that will provide you with many years of energy saving in your home while protecting your home from the harmful affects of excess humidity such as dampness, condition & mould. Keep you & your family healthier with fresh air & save money keeping expensive heat in your home with your ECOR PRO LD800.
Yours sincerely,
ECOR PRO
Customer Service Department

  • Before using your unit for the first time, please ensure that is has been standing for 2 hours in it’s upright position before it is plugged in.
    ECOR PRO LD800 80 Litre Compressor Dehumidifier 01

Your unit helps to avoid:

  •  dampness
  • condensation
  •  mould
  •  smells

Aiding other problems caused by “bad” air conditions:

  •  sickness
  •  headaches
  •  allergies

Your unit brings:

  • DIY heat loss solution

GENERAL SAFETY
For safety reasons, please read this manual carefully before operating. Persons who are not familiar with this manual must not use this unit. We strongly recommend keeping this manual in a safe place for future reference. This appliance is safe, however, as with other electrical appliances, use it with care. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge.
Warning!
Never operate this appliance if it has a damaged cord or plug. If the supply cord is damaged, it must be replaced by an approved service representative or similar qualified person in order to avoid any hazards.
There should be direct access to the electrical plug after connecting the power!
Do not use your unit under the following conditions:
ECOR PRO LD800 80 Litre Compressor Dehumidifier 01

  • IF the power cable wires are frayed 0r  damaged

ECOR PRO LD800 80 Litre Compressor Dehumidifier 03

  • Where the power cable may be  damaged
    ECOR PRO LD800 80 Litre Compressor Dehumidifier 04

  • If the unit is placed unevenly
    ECOR PRO LD800 80 Litre Compressor Dehumidifier 05

  • If the unit is, or can be in contact with chemicals
    ECOR PRO LD800 80 Litre Compressor Dehumidifier 06

  • If there is a risk of liquid falling on the unit”
    ECOR PRO LD800 80 Litre Compressor Dehumidifier 26

  • If the unit is immersed with  water
    ECOR PRO LD800 80 Litre Compressor Dehumidifier 07

  • Close to a heat source
    ECOR PRO LD800 80 Litre Compressor Dehumidifier 08

  • Where there is a risk of interference  by foreign objects
    ECOR PRO LD800 80 Litre Compressor Dehumidifier 09

  • If an extension cord is needed to reach an outlet
    ECOR PRO LD800 80 Litre Compressor Dehumidifier 10

  • When small children may be left  unattended

  • This appliance must be grounded and should only be  connected to   a grounded 230V ~/ 50 Hz main supply.

  • The installation must be in accordance with the regulations of the country where the unit is used.

  • The unit is designated for indoor operation only.

  • This product is not made for DIY repair

INSTALLATION FOR INDOOR AREAS

Ideal for crawl spaces / home lofts
garages / warehouses / offices / whole home
Advantages
LD800 home dehumidifier, ventilator and heat recovery is 225% efficient at retaining heat from the home and introduction of fresh air.

Ecor Pro LD800:

Whole Home Dehumidifier, Ventilator & Heat Recovery Unit 

ECOR PRO LD800 80 Litre Compressor Dehumidifier 11Mechanical heat conserved and re-introduced into the home:

  •  Airflow 350 – 450 m3/h
  •  Dehumidification up to 80 litres / day
  •  Dehumidification at AHAM conditions up to 90 pints
  •  Adjustable fresh air slider up to 100 m3/hr fresh air
  • Pollen filter, easily changeable.
  • Can be included into an air ducting system.
  • Can be combined with a central air system.
  • One inlet and two outlets.
  •  All can be T-ducted to take air from multiple points or redeliver air to several points.
  •  Can run on fan only just to filter and circulate air in summer:
  • Fresh air inlet (150 mm).
  •  Water drainage via side brass compression. connector (19 mm).
  •  Top / Back or Top and Back exhausts (250 mm).
  •  All metal construction and housing.
  •  Useable ceiling hung in lofts.

Optional
ECOR PRO LD800 80 Litre Compressor Dehumidifier 11

  • Optional controller to give on–off controls and regulate user-set environment.
    Out of the box
    You will find in the shipping carton:

  • LD800 unit, complete with sealed wire and plug.

  • 4 adjustable feet.
    (Place the adjustable feet in the holes underneath the unit and set the unit level).

  • Remove the tyrap (as indicated.
    Check the rating plate, if the unit is made for the current you use.

  • Remove tie after installation.

HOW IT WORKS

Your ECOR PRO LD800 dehumidifier controls the Relative Humidity by passing the air through the unit forcing the excess moisture to condensate over a cooling heat exchanger. This condensate water flows safely into a fixed drain. The dried air then passes through a final heat exchanger where it is warmed before it re-enters the area at a slightly elevated temperature. The level of dehumidifying is set withe a digital humidistat control.(not supplied). Ideal humidity is defined as being between 40-60%(Relaltive Humidity) on an average annual base.
40% RH – 60% RH

ECOR PRO LD800 80 Litre Compressor Dehumidifier 15 Points to consider before installation:

  • Fresh air Intake (ø 150 mm)
  •  I nlet moist air (ø 250 mm)
  •   Changeable air filter – Filter must be placed
  • Drain – Drainage tube connection point (female 3/4” – 19 mm)
  • Rear outlet (ø 250 mm) – Warmer, dried and cleaner air
  • 2nd outlet (optional) – Easy to fit additional duct if desired
  • Connecting a controller (optional) – see next page
  • Connecting to the mains (refer to the rating plate)
    For the most efficient use, outside doors and windows should be kept closed when the dehumidifier is operating.

POSITIONING YOUR LD800
WARNING
Before using the appliance it should be left in an upright position for at least 2 hours. Your unit can be installed in any area with a relative humidity that is too high; such as a basement, play area, shed, archive room, swimming pool, boat, etc, The unit will begin to protect from the harmful effects of excess moisture as soon it is installed an plugged in. The unit can stand on the floor or hung on a wall. When positioning your unit, ensure that it is placed level. Best results are obtained when windows and doors are closed, thus preventing the possible influx of fresh, too humid, air.

  • This appliance must be grounded and should only be connected to a grounded 230V ~/ 50 Hz main supply.
  • The installation must be in accordance with the regulations of the country where the unit is used.
  • The unit is designated for indoor operation only.

Connecting a controller (optional)
Optional controller to give on-off controls and regulate user-set environment. The controller is used to sense the conditions in the home. When the humidity gets beyond the user defined level. the LD800 will automatically start working. More complex controllers can be fitted to react to temperature and CO2.
ECOR PRO LD800 80 Litre Compressor Dehumidifier 16

  • A For connecting to central air or heating controller
  • B To control dehumidification
  • C To control just the fan only and circulate air, but not dry the air

Continuous drainage operation – side humidity
Drainage tube connection point. Excess water can be drained to the eaves, or suitable drain. If gravity drain is not possible, an additional pump should be fitted.

  • 3/4” (19mm) female water outlet
    Into drain at eaves or central drain system.
    The pipe must be positioned so that there is a gradual downward slope from the connecting point to the drain. Ensure that the outlet of the drainage pipe is not under the water level of the drain.

Note:
In very cold weather conditions, precautions should  be taken  to prevent the drainage tube from freezing.
Fresh air Intake (ø 150 mm)
Can take air from the loft space (which often has heat from the home and solar gain from  roof tile sunlight absorption) or alternatively can be ducted to the outside through the roof (with suitable connection) or to the roof eaves, to draw fresh air in.
Fresh air regulator
Simple slider setting to allow the right amount of fresh air into the home – set by user.
ECOR PRO LD800 80 Litre Compressor Dehumidifier 18

  • Knob to loosen
  • fasten the slider

If the dehumidifier does not operate:

  • Make sure the unit is plugged in.
  •  Ensure the controller (optional) is turned on.

If the unit is noisy:

  • Make sure the dehumidifier is standing solidly and level.

If the unit is leaking:

  • Check the drainage tube for correct fitting.
  • Check for twists and bends in the drainage tube.
  • Check the drainage tube for a sufficient slope.
  • Check and make sure that the outlet of the drainage pipe is not under  the  water-level in the drain.

IMPORTANT:
This dehumidifier should not be used in temperatures below 5 oC or above 35 oC.
Installation – suitable for all indoor areas whether in the home, retail outlets, offices or other
Your unit can be installed in any area. Fresh, clean, dry air can be ducted as needed. Damp air can be extracted where needed. Can cope with a whole home if placed in a loft, basement or cupboard if ducted correctly. Can even manage that air of a swimming pool environment (special coating permits).
ECOR PRO LD800 80 Litre Compressor Dehumidifier 18

  • Fresh air Intake (ø 150 mm)– Can take air from the loft space (which often has heat from the home and solar gain from roof tile sunlight absorption) or alternatively, can be ducted to the outside through the roof (with suitable connection) or to the roof eaves to draw fresh air from outside.
    Fresh air regulator – Simple slider setting to allow the right amount of fresh air into the home set by user.

  • Inlet moist air (ø 250 mm) – Can have single or multiple inlets by using Y or T connectors to the inlet pipe connected to other rooms to draw air from typically the bedrooms into the unit.

  • Rear outlet. (ø 250 mm)- Often ducted to central location in the home such as landing.

2nd outlet (optional)– Easy to fit additional duct to the living area (on top of the unit).
LD800 included in a ducted system
ECOR PRO LD800 80 Litre Compressor Dehumidifier 20 Side humidity – Drainage tub connection point. Excess water can be drained to the eaves, or suitable drain. If gravity drain not possible an additional pump should be fitted.
Controller (optional) – A controller is used to  sense the conditions in the home. When the  humidity gets beyond the user defined  level the LD800 will automatically start working. More complex Controllers can be fitted to react to temperature and CO2.
Changeable filter – Filters the air before  heat is extracted and circulated back into the  home, helping allergy sufferer.
Top viewECOR PRO LD800 80 Litre Compressor Dehumidifier
21 LD800 can be incorporated in a central air system
ECOR PRO LD800 80 Litre Compressor Dehumidifier 22 CLEANING
Disconnect from the mains before cleaning or servicing the unit or any of its components.
Housing (all metal housing)
Wipe regularly clean with a moist cloth (a soft, damp cloth) and a mild household detergent, Never use aggressive chemicals, petrol, agressive detergents or other cleansing solutions.
Air filter (HEPA type)
Remove for periodic replacement, helping to redeuce the need to dust and helping against bacteries, helping to prevent allergies. Air circulation is impeded and the efficiency of the dehumidifying and air purifying functions decreases when the filter is dirty. It is therefore good practice to replace the filter at regular intervals. The precise intervals depend on the room in which the appliance operates and on how frequently it is used. Replace the filter at least once a year. If you do not replace the filter in time, the unit gets dirty inside and the dirt may cause damage.
Caution
This unit should not be operated without the air filter fitted. Operation without the air filter may damage the heat exchangers.
Servicing
Have your unit once a year serviced by a qualified engineer.
How to place a new filter :
ECOR PRO LD800 80 Litre Compressor Dehumidifier 23

  • A. Remove the magnetic seal (filter access door) on one of the two sides.

  • B. Remove the small metal plate by loosening the screw.

  • C. Slide the filter out of the unit.
    Place the new filter (C).

  • Replace the small metal plate (B) with the screw.
    Replace the magnetic seal (A) carefully to cover the door.

TECHNICAL DATA

ECOR PRO LD800 80 Litre Compressor Dehumidifier 24

Dehumidifier, Ventilator & Heat recovery Unit|

LD800

Model D005A-80L

---|---
Rated voltage| 230V ~
Rated frequency| 50 Hz
Rated input| 890 W
Rated current| 4.0 A
Resistance Class| IP20
Air flow| 350-450 m3/h
Rated dehumidifying capacity| 80 l/day (300C – RH 80%
Applicable temperature| 5-35 oC
Refrigerant / Weight| Environmentally friendly R410A / 660 g
Max. allowable pressure| Discharge 5.0 MPA Suction 1.2 MPA
Dimensions (mm)|
Length| 800 ( 640)
Width| 374
Height| 495
Weight| 36 kg

Low Voltage Directive 2014/35/EU – EMC Directive 2014/30/EU Specifications may change without prior notice.

WIRING DIAGRAM – LD800

220-240 V / AC • 50 HZ • SINGLE PHASE
ECOR PRO LD800 80 Litre Compressor Dehumidifier 26 GUARANTEE CONDITIONS
The LD800 is supplied with a 24-month guarantee, commencing on the date of purchase. All material and manufacturing defects will be repaired or
replaced free of charge within this period. The following rules apply:

  • We expressly refute all further damage claims, including claims for collateral damage.
  • Repairs to or replacement of components within the guarantee period will not result in an extension of the guarantee.
  • The guarantee is invalidated if any modifications have been made, non genuine parts are fitted or repairs are carried out by third parties.
  • Components subject to normal wear, such as the filter, are not covered by the guarantee.
  • The guarantee is valid only when you present the original, dated purchase invoice and if no modifications have been made.

Disposal
Waste electrical and electronic products must not be disposed of with household waste.
This product should be taken to your local recycling centre for safe treatment.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals