KLARSTEIN 10030744 Summershine Slim Light Shower Instruction Manual

June 5, 2024
Klarstein

KLARSTEIN LOGO

SUMMER SHINESLIM
Light Shower

10030744
www.klarstein.com
Version (ZP-LND018915V2-IM-2022-01-10-0A)

Dear Customer,
Congratulations on purchasing this device. Please read the following instructions carefully and follow them to prevent possible damage. We assume no liability for damage caused by disregard of the instructions and improper use. Scan the QR code to get access to the latest user manual and more product information.

https://use.berlin/10030744

TECHNICAL DATA

Item number 10030744
Dimensions (W x H x D) 260 x 150 x 17 mm
Weight 450 g
Lighting elements LEDs
Light intensity > 10.000 lux in 6 cm
Mains connection 12 V DC 1 A
Operating Environment 0 to +40 °C, and relative humidity from 30 % to 90 %.

Atmospheric pressure: 700-1060 hPa
Storage Environment| -10 to +60 °C, and relative humidity of max. 90 %. Atmospheric pressure: 700-1060 hPa
Transport Environment| -10 to +60 °C, and relative humidity of max. 90 %. Atmospheric pressure: 700-1060 hPa
Product Classification| 1. Class II equipment
2.No applied part
3. Protection against ingress of water: IP21
4. Not category AP / APG equipment
5. Mode of operation: Continuous operation.
The maximum length of the power cord| 2000 mm

Included in delivery:

  • Light shower
  • Power adapter
  • Instruction manual

Maximum output of optical radiation for the appliance

Radiance Output Risk group classified by IEC 60601-2-57:2011 Max. Wert
EUVA: Eye UV-A Exempt group 1.0X104 Wm-²
ES: Actinic UV skin and eye Exempt group 1.0X104 Wm²
EIR: Infrared radiation hazard exposure limits for the eye Exempt group

1.0X10¹ W.m²
EH: Thermal hazard for the skin| Exempt group| 2.0X10¹Wm-²
LB: Blue light| Exempt group| 5.0 x10¹ W.m.²•srl
LR: Retinal thermal| Exempt group| 5.0 x10¹Wm- ²•sr-1

ABOUT THE LIGHT SHOWER

Notes on operation
Congratulations on the purchase of your light shower. The product is very durable and will provide you with many years of use, provided you handle it correctly. Please keep your receipt, these instructions, and the original packaging for reference and storage.
Please read the instructions carefully to get the most benefit from your new device, However, the instructions are not a substitute for advice from a qualified medical advisor.

Intended use
The device is used to treat seasonal depression or winter depression. Daylight increases the energy level of many people and helps them to better adapt to the rhythm of the day and to be more alert. Light showers have been proven to treat the winter blues for several years.

How does the light shower work?
In autumn and winter, the number of sunlight decreases as the days become shorter. The lack of sunlight causes a problem with certain chemicals in the brain in many people and prevents the hypothalamus from working properly. The lack of light, in return, stimulates the production of the hormone melatonin, which makes you sleepy. The light shower radiates with the strength of sunlight, simulating the lack of light during the dark seasons. At the same time, the dangerous UV rays contained in sunlight are filtered out. The extra light helps the brain reduce and level the production of the hormone melatonin, reducing the symptoms of winter depression.

Symptoms of winter depression
Winter depression can manifest itself through the following symptoms:

  • You feel low, listless and fatigued.
  • You have trouble concentrating.
  • You feel lacking in energy.
  • You need more sleep.
  • You are less active than usual.

Contraindications
Use is counterproductive and not recommended for the following diseases and symptoms. Always consult your family doctor first before use if you are affected:

  • Severe depression.
  • Recent eye surgery or diagnoses where bright light should not be allowed to enter the eyes.
  • High blood pressure.
  • Photosensitive skin or lupus erythematosus.

Possible side effects
The following side effects may occur during treatment with the light shower:

  • Headache
  • Sleep problems
  • Eyestrain
  • Nausea

What you can do about it:

  • Increase the distance from the light shower.
  • Don‘t use it late at night or just before going to sleep.
  • Take a break for a few days until symptoms go away and try again.

SIGNS AND SYMBOLS

The following symbols appear in this manual, on the device or on its accessories:

| Read operating instructions before use| **| Caution: Consult accompanying documents
---|---|---|---
| Specifies serial number of the device.| | Authorized
Representative in the European Community.
| ON/OFF| | Class II Equipment
| Date of Manufacture| | Manufacturer
| Importeur| | DC Polarity
`
MD| Medical Device| IP21**`| Ingress Protection Rating

SAFETY AND PERFORMANCE STANDARDS

This appliance has been designed and manufactured to conform to the highest standards of safety and performance, including electromagnetic compatibility (EMC). This appliance conforms to the applicable requirements of the following:
This appliance meets the requirement of the Medical Device Directive 93/42/EEC / Medical Device Regulation (EU) 2017/745 for medical devices.
The appliance ist complied with the following emission and immunity standards, and test level:

Emissions Test Standard Compliance
RF emission CISPR 11 Group 1
RF emissions CISPR 11 Class B
Harmonic emissions IEC 61000-3-2 Class A
Voltage fluctuations/flicker emissions IEC 61000-3-3 Comply
Immunity Test standard IEC 60601-1-2 Test Level

Level**
---|---|---
Electrostatic
discharge (ESD) IEC 61000-4-2| ± 8 kV contact
± 2 kV, ± 4 kV, ± 8 kV, ± 15 kV air| ± 8 kV contact
± 2 kV, ± 4 kV, ± 8 kV, ± 15 kV air
Electrical fast transient/burst IEC 61000-4-4| ± 2 kV for power supply lines ± 1 kV signal input / output 100 kHz repetition frequency| ± 2 kV for power supply lines Not applicabel
100 kHz repetition frequency
Surge IEC 61000-4-5| ± 0.5 kV, ± 1 kV differential lines
± 0,5 kV, ± 1 kV, ± 1 kV common mode| ± 0.5 kV, ± 1 kV differential lines Not Applicable
Voltage dips, interruptions and variations on power supply input lines
IEC 61000-4-11| 0 % UT; 0.5 cycle. At 0°, 45°, 90°, 135°, 180°, 225°, 270° and 315°
0 % UT; 1 cycle and 70 % UT; 25/30 cycles;
Single phase: at 0°.0 % UT; 250/300 cycle| 0 % UT; 0.5 cycle. At 0°, 45°, 90°, 135°, 180°, 225°, 270° and 315°
0 % UT; 1 cycle and 70 % UT; 25/30 cycles;
Single phase: at 0°.
0 % UT; 250/300 cycle
Power frequency (50/60 Hz) magnetic field
IEC 61000-4-8| 30 A/m
50 Hz/60 Hz| 3 A/m
50 Hz/60 Hz
Conducted RF IEC 61000-4-6| 3 V
0.15 MHz – 80 MHz
6 V in ISM and amateur radio bands between 0.15 MHz and 80 Mhz
80 % AM at 1 kHz| 3 V
0.15 MHz – 80 MHz
6 V in ISM and amateur radio bands between 0.15 MHz and 80 Mhz
80 % AM at 1 kHz
Radiated RF IEC 61000-4-3| 10 V/m
80 MHz – 2.7 GHz
80 % AM at 1 kHz| 10 V/m
80 MHz – 2.7 GHz
80 % AM at 1 kHz

Note: UT is the a.c. mains voltage prior to application of the test level.

SAFETY AND PERFORMANCE STANDARDS
(CONTINUED)

Guidance and manufacturer’s declaration – electromagnetic immunity

Radiated RF IEC 61000-4-3(Test specification for ENCLOSURE PORT
IMMUNITY to RF wireless
communications equipment| Test Frequency
(MHz)| Band (MHz)| Service| Modulation| Maximum
power (W)| Distance

(m)

| IMMUNITY
TEST LEVEL
(V/m)
| 380 -390|

TETRA 400

|

Pulse
modulation 18 Hz

| 1.8| 0.3| 27
385
450| 430-470| GMRS 460,
FRS 460| FM ± 5 kHz deviation 1 kHz sine| 2| 0.3| 28
710| 704 –

787

| LTE Band
13, 17| Pulse modulation
217 Hz| 0.2| 0.3| 9
745
780
810| 800 –

960

| GSM 800/900
TETRA 800 iDEN
820 CDMA 850
LTE Band 5| Pulse modulation
18 Hz| 2| 0.3| 28
870
930
1720| 1700 –

1990

| GSM 1800; CDMA  900; DECT; LTE Band 1, 3, 4, 25; UMTS| Pulse modulation
217 Hz| 2| 0.3| 28
1845
1970
2450| 2400 -2570| BT, WLAN, 802.11
b/g/n RFID 2450,
LTE Band 7| Pulse modulation
217 Hz| 2| 0.3| 28
5240| 5100-

5800

| WLAN 802.11 a/n| Pulse modulation
217 Hz| 0.2| 0.3| 9
5240
5785

SAFETY INSTRUCTIONS

  • Do not use the light shower in damp places.
  • Before use, remove all packaging and check the device for damage. If you are unsure, contact customer service.
  • The device may only be used by suitable persons.
  • Children should be supervised during use. This light shower is not a toy.
  • They do not need special training for this device.
  • Keep the power cord away from heat and open fire.
  • The minimum distance between the light shower and flammable objects must be 1 m.
  • The operating voltage must correspond to that indicated on the rating plate.
  • After use, disconnect the power plug and allow the light shower to cool down.
  • Never touch the light shower with wet hands. Keep them away from moisture.
  • Protect the light shower from strong impacts.
  • Never pull on the power cord, grasp the plug to pull it.
  • If the power cord is damaged, it must be replaced immediately by qualified personnel.
  • Never attempt to repair the light shower yourself.
  • Disconnecting from the mains can only be done by pulling the mains plug. Always use an easily accessible power outlet.
  • Do not use the device near volatile substances, pure oxygen or nitrous gases.
  • The device does not require any adjustment.
  • The device has no components that can be repaired or maintained.
  • The user must not touch the appliance and the person to be treated at the same time.
  • The device must not be modified.
  • In case of health concerns of any kind, consult your family doctor!

Important notes on electromagnetic compatibility (EMC)

  • Use of this appliance adjacent to or stacked with another device should be avoided because it could result in improper operation. If such use is necessary, this appliance and the other device should be observed to verify that they are operating normally. If the appliance does not light on or flickering, it means that the appliance is not operating normally.
  • Do not use near active HF surgical equipment and the RF shielded room of an ME system for magnetic resonance imaging, where the intensity of EM disturbances is high. • Do not change any cable without the authorization of the manufacturer. The use of cables other than those specified or provided by the manufacturer of this appliance could result in increased electromagnetic emissions or decreased electromagnetic immunity of this appliance and result in improper operation.
  • Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm to any part of this appliance, including the power cable. Otherwise, degradation of the performance of this equipment could result.
  • If the appliance does not light on or flickers due to the electromagnetic disturbances do not use it and try to place the appliance in another location.
  • For maintaining the basic safety and essential performance with regard to electromagnetic disturbances for the expected service life, precautions shall be taken when the site of use is in the vicinity (e.g. less than 1.5 km away) of AM, FM or TV broadcast antennas.

Important notes on operation

  •  This device is not intended for commercial or clinical use, but exclusively for personal use in the private household! The use of the daylight shower is NOT a medical treatment.
  • If you are taking medication such as painkillers, antihypertensives, or antidepressants, you should consult your doctor before using the daylight shower.
  • People with retinal diseases should be examined by an ophthalmologist before starting to use the daylight shower, just as diabetics.
  • Please do not use in case of eye diseases such as cataracts, glaucoma, diseases of the optic nerve in general, and inflammation of the vitreous humor.

Maintenance and repairs

  • Do not attempt to repair the device yourself. This could result in serious injury. Failure to do so will void the warranty.
  • If this device is damaged in any way or does not work, do not continue to use it. Try troubleshooting the problem (see Troubleshooting). If it persists, contact customer service or the dealer, as special tools are required to make repairs. Never attempt to repair the device yourself.
  • Do not expose the screen to direct sunlight, spotlights or other sources of heat.
  • Do not use alcohol or ammonia-based liquids to clean the screen.

DEVICE OVERVIEW

KLARSTEIN 10030744 Summershine Slim Light Shower -
fig1

1 Lampshade
2 On/Off button
3 Hole for the stand
4 Storage space for the stand
5 Mains connection
6 Stand

COMMISSIONING AND OPERATION

Before operation

  1. Remove the stand from the storage compartment.
  2. Insert one end of the stand into the hole on the back of the unit.
  3. Place the unit on a flat surface about 20 cm from your eyes. The light should hit the side of your face slightly.
  4. Plug the device into a 220-240 V outlet. Insert the plug firmly into the outlet and use an outlet that is close to the installation site. Route the cord so that no one will trip over it.

Operation

  1. Press a power button to turn on the device.
  2. While using it, you can read, write, make phone calls or do work. While using the device, try to keep the recommended distance of 20 cm between your eyes and the device. The recommended treatment time is about 2 hours. Important: do not look directly into the light all the time. During the first sessions, you may experience eye pain and headache, which will not occur during the following sessions. In this case, interrupt the application and reduce the duration of use. Do not leave the device unattended during operation.
  3.  In the darkest season of the year, you should apply the application for at least consecutive days or longer, depending on your personal condition.
  4. When you are finished with the application, press the on/off button to turn off the device.

CLEANING AND STORAGE

  • Before cleaning, turn the unit off and unplug it from the wall outlet.
  • Do not handle the device with wet hands.
  • Clean the device with a damp cloth and some washing-up liquid.
  • Make sure that no water enters the device.
  • Clean the device once a month.
  • If you do not use the device for a longer period of time, store it in a dry place.
    Keep out of the reach of children. Do not leave the device plugged in if you are not going to use it for a long time.

TROUBLESHOOTING

Problem Possible cause Solution
No light. Switched off. Switch on.
No power. Connect to mains.
No current. The cable is broken and must be replaced by a specialist company.
LEDs have reached the end of their service life. If the device needs to

be repaired, contact the manufacturer or a specialist company in your area.

The LEDs are broken.

DISPOSAL CONSIDERATIONS

If there is a legal regulation for the disposal of electrical and electronic devices in your country, this symbol on the product or on the packaging indicates that this product must not be disposed of with household waste. Instead, it must be taken to a collection point for the recycling of electrical and electronic equipment. By disposing of it in accordance with the rules, you are protecting the environment and the health of your fellow human beings from negative consequences. For information about the recycling and disposal of this product, please contact your local authority or your household waste disposal service.

DECLARATION OF CONFORMITY

European Authorised Representative:
Global mind Consumer Electronics GmbH
Ernst-Mantius-Str. 11, 21029 Hamburg, Germany
Manufacturer:
Zero-Plus International Limited Room 1004, 10/F., Join-In Hang Sing Centre,
71-75 Container Port Road, Kwai Chung,
New Territories, Hong Kong
E-mail: sales@zeroplus.hk
Imported by:
Chal-Tec GmbH, Wallstraße 16, 10179 Berlin, Germany.
This product conforms to the following European Directives:
93/42/EWG 2011/65/EU/2017/745/EU