Thank you for purchasing the Lumatek Zeus 1000W Pro linear multi-light bar LED fixture. This manual describes how to install and use the Zeus Pro fixture; please read this manual thoroughly before attempting to install or operate any Lumatek Zeus Series system. If you are not comfortable with the installation of high performance lighting systems, you should seek the services of a qualified installation professional.
PRODUCT DESCRIPTION
The Lumatek Zeus 1000W Pro LED is an electronic horticultural LED fixture using a wide-array design with two integrated 500W Pro intelligent LED drivers making the fixture externally controllable & dimmable. The ZUES 1000W Pro fixture is an ultra-high performance full-cycle top lighting solution for commercial horticulture cultivation, with the power and flexibility to scale from propagation and cloning through vegetative growth to higher light intensities in bloom. In this manual the Lumatek Zeus 1000W Pro LED will be referred to as: “the LED fixture”.
PRODUCT INFORMATION AND SPECIFICATIONS
3.1 General Product Information
PRODUCT NAME | Zeus 1000W PRO LED |
---|---|
MANUFACTURER | Lumatek EU |
PRODUCT CODE | LUMLED009 |
EAN | 5.061E+12 |
PLUG TYPE | UK/EU |
3.2 Technical Specifications
PPF | 2925 μmol/s |
---|---|
EFFICACY | Up to 2.9 μmol/J |
SPECTRUM | Full-spectrum F |
LIGHT SOURCE | Higher spec LUMILEDS (W) & Osram (R) LED |
DIMENSIONS (LxWxH) | 1700 x 1099.6 x 48.2mm |
WEIGHT | 17.5Kg |
LIFE SPAN | 60000H |
WORKING TEMPERATURE | -20ºC — +40ºC |
WORKING HUMIDITY | 20% – 90% |
WATERPROOF / DUSTPROOF | IP65 |
BEAM ANGLE | 120º |
MANUAL DIM/EXTERNAL LIGHTING CONTROLLER | 0-10V analog protocol |
INPUT
VOLTAGE (V)| DIMMING
RATIO| INPUT
POWER(W)| INPUT
CURRENT(A)
---|---|---|---
Vmains=230V
50/60Hz AC| 100%| 1075| 4.76
75%| 821| 3.66
50%| 530| 2.41
25%| 268| 1.36
Vmains=240V
50/60Hz AC| 100%| 1075| 4.56
75%| 820| 3.51
50%| 530| 2.33
25%| 267| 1.33
Vmains=277V
50/60Hz AC| 100%| 1075| 3.99
75%| 818| 3.08
50%| 530| 2.1
25%| 268| 1.26
3.3 Fixture Dimensions
3.4 Spectral Quantum Distribution Graph
The Zeus Pro series use higher spec highly efficient top bin horticultural
white & red LEDs to creat a balanced full spectrum of quality light ideal for
photosynthesis.
3.6 Environment
The LED fixture is intended to be used in climate-controlled grow rooms and
indoor farms.
The product may be used in damp environments but may not be used in wet
environments or outdoors.
The product will operate in ambient temperatures from -10ºC to 40ºC but will
function at optimal level between 20ºC to 30ºC.
The product will operate in 20% – 90% humidity, non-condensing.
3.7 Legal
This product is CE-certified compliant with LVD and EMC directive test
standards.
SAFETY RECOMMENDATIONS AND WARNINGS
Warning! Carefully read the warnings below before using or working with the product!
-
Always adhere to the local rules and regulations when installing or using the LED fixture.
-
Do not open or disassemble the LED fixture as it contains no serviceable parts inside. Opening or modifying the LED fixture can be dangerous and will void the warranty.
-
Do not use the LED fixture when either the LED fixture or its power cable are damaged. Replace the power cable with correctly rated cable only.
-
Modifications to the cables can lead to unwanted electromagnetic effects which may make the product not comply with legal requirements.
-
Do not expose the LED fixture to:
Condensing humidity, heavy mist or direct spray;
Ambient temperatures outside the specified range; Dust and contamination;
Direct sunlight during use or HID light may heat up the driver. -
Always disconnect the LED fixture from the mains before performing any maintenance.
-
Always allow for a cool-down period of at least 20-30 minutes before touching the LED light bars. Touching the LED bars when the fixture is lit or immediately after may result in burns!
-
Natural convection removes heat away from the heatsink. In order for the system too properly cool itself, at least 5cm of space is required between the fixture and the roof of your grow area. Do not use abrasive materials or aggressive cleaning agents to clean the LED fixture as this may damage the secondary optics. Instead use a clean dry fabric/cloth.
-
Do not use the LED fixture near flammable, explosive or reactive substances. The LED fixture can reach temperatures of 40ºC.
-
Do not use sulphur vaporizers or water misters.
-
The installation and use of the LED fixture is the responsibility of the end user. Incorrect use or installation can lead to failure and damage to the LED fixture. Damage to the LED fixture and electronic circuitry as a result of incorrect installation and use revokes the warranty.
CONTENTS
INSTALLATION
Warning! Mounting and installing the LED fixture must be in accordance with
the applicable local laws and regulations.
Warning! The installer is responsible for correct and safe installation.
Warning! Ensure the local cabling can support the voltage and current
requirements of the LED fixture.
Warning! Avoid coiled cables and keep mains leads separated to help prevent
electromagnetic interference.
Warning! Do not connect or disconnect the LED fixture under load.
6.1 Fixture assembly & installation
The fixture frame uses a folding design for easier use and storage. After
removing the components from the packaging, open the frame fully.
There is a hinge-lock metal plate for each hinge to secure and balance the
fixture. Align each plate correctly with hinge and push onto outside of
frame/hinge and click into place.
Fig. hinge-lock plates connect by pushing onto outside of frame over each
hinge.
6.2 Connect the LED light bars
Warning! The light bars are shipped with protective plastic covers over the
diodes.
Please ensure these protective covers are removed before use!
6.3 Changing and replacing light bars and modular use
The LED fixture’s modular design uses intelligent LED drivers which can
decrease or increase power to match the amount of 100W light bars installed on
the fixture automatically. If not all light bars are required, the drivers
will only draw power required for the number of light bars connected eg if six
light bars are connected the drivers will only draw 600W to power them.
Warning! At least one light bar must be installed in the fixture before
switching on.
6.4 Installing the fixture
Warning! Mount the system to something that can hold the weight of the LED
fixture.
Ensure all light bars are installed correctly and are secure.
Carefully turn the fixture over and attach the metal cable hangers to the
mounting hooks.
Hang the fixture in required position and height.
For optimal performance; position fixture 50 -100cm above plant canopy for a
1.5 x 2m light spread.
Ensure the fixture is hung horizontally.
6.5 Connecting the manual dimmer or external lighting controller
The dimmer control or lighting controller is connected to the ‘SIG IN’
connector on the fixture frame.
This enables light intensity (PPF output) to be adjusted according to
requirement. The LED fixture light intensity can be adjusted without changing
relative spectral power distribution or losing efficiency. Remove dust cap and
ensure male & female connectors are correctly aligned and then push together
until click-locked. To disconnect; turn twist-lock anti-clockwise and pull
apart.
6.6 Connecting fixtures in series for external control
For detailed instructions please refer to the Lumatek Control Panel
manual.
Position and hang each fixture appropriately. Zeus series fixtures use 0-10V
signal protocol for control.
Connect controller output signal cable to fixture 1 SIG IN connector.
Connect daisy-chain control signal cable from fixture 1 SIG OUT connector to
fixture 2 SIG IN connector.
Continue to connect fixtures in series for up to 100 fixtures per controller,
see Fig.
6.7 Connecting the LED fixture to the mains
Warning! Make sure mains power is switched off.
Warning! Ensure the power supply cable is not coiled and does not touch any
hot surfaces.
Warning! Connect the cables according to local rules, safety regulations and
electrical code.
Warning! If not using an external lighting controller ensure external
switching gear can cope
with theinrush current of the LED fixture. Always use a timer contactor
suitable for switching
a capacitive load. Never use household timers to switch the LED fixture!
Ensure the LED fixture power supply cable twist-lock connector is correctly
aligned to the AC INPUT connector on the fixture frame and push together until
click-locked. Connect mains power plug to switching gear/power supply. Switch
on mains power.
PRECAUTIONS WHEN USING THE LED FIXTURE
Warning! Always ensure at least one light bar is connected to the fixture
before switching on.
The Zeus 1000W Pro fixture has two intelligent 500W Pro LED drivers which can
increase or decrease power to match the amount of light bars connected to the
system automatically. Warning! Always wait 20 – 30 minutes for the LED light
bars to cool down.
INSPECTION, MAINTENANCE AND REPAIR
Warning! Disconnect the LED fixture from mains before performing any
maintenance or repairs.
Warning! Do not connect or disconnect the LED fixture under load.
Warning! Do not open or disassemble the LED fixture, it contains no
serviceable parts inside. Opening the LED
fixture can be dangerous and will void the warranty.
Warning! Always wait 20 – 30 minutes for the LED light bars to cool down.
Caution! Do not clean the LED fixture with detergents, abrasives or other
aggressive substances.
Regularly check the LED fixture for dust or dirt build up. Clean if necessary.
Contamination may cause overheating and decreased performance.
Clean the outside of the LED fixture using a dry or damp cloth.
Regularly check the cables of the LED fixture to ensure it is undamaged.
STORAGE AND DISPOSAL
Store the LED fixture in a dry and clean environment, with an ambient
temperature of -25ºC to 55ºC.
The product must not be discarded as unsorted municipal waste but must be
collected separately for the purpose of treatment, recovery and
environmentally sound disposal.
WARRANTY
Lumatek Ltd warrants the mechanical and electronic components of their product to be free of defects in material and workmanship if used under normal operating conditions for a period of five (5) years from the original date of purchase. If the product shows any defects within this period and that defect is not due to user error or improper use Lumatek Ltd shall, at its discretion, either replace or repair the product using suitable new or reconditioned products or parts. In case Lumatek Ltd decides to replace the entire product, this limited warranty shall apply to the replacement product for the remaining initial warranty period, i.e. five (5) years from the date of purchase of the original product. For service; return the product to your shop with the original sales receipt.
**STAY UP TO DATE WITH OUR SOCIAL MEDIA CHANNELS
GENERAL :info@lurnatek-lighting.corn
SALES SUPPORT :orders@gumatek-lighting.com
TECHNICAL SUPPORT :techsupport@Vumatek-lighting.com
CONTACT: +44(0)1233 280567
VISIT US ATWWW.LUMATEK-LIGHTING.COM**
References
- Sustainable LED lighting solutions | Philips lighting
- LUMATEK Professional Grow Lighting | Ballasts | Lamps | Reflectors
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>