QUINEAR QN-071A Air Compression Leg Recovery System User Manual

June 14, 2024
QUINEAR

QUINEAR QN-071A Air Compression Leg Recovery System

QUINEAR-QN-071A-Air-Compression-Leg-Recovery-System-
Product

Please read the instructions carefully before use and keep it well for further reference.

Safety Precautions

Please read the following safety precautions carefully to ensure the safe and correct use of the QUIN EAR Air Compression Leg Recovery System.

Warnings
No modification of this equipment is allowed.

  • If you experience severe pain, or any unusual symptoms, or want to remove the sleeves in an emergency during use :
    • Press the power button to stop the device or disconnect the hoses;
    • Remove the sleeves and consult your doctor.
  • Consult your doctor before using this device if you have any of the following conditions;
    • Experiencing inflammation, an infection, or pain of unknown origin, at or near the site of application;
    • Have bone fractures or dislocations at or near the site of application
    • Receiving medical treatment, or having a contraindication requiring the use of any medical control unit.
    • Using pacemakers or other medical devices which are susceptible to electrical interference;
    • Suffering from malignant tumors;
    • Suffering from cardiac diseases;
    • Suffering from osteoporosis;
    • Having serious peripheral neuropathy dysfunction or sensory disturbance caused by diabetes;
    • Being unsuitable to do the massage because of traumas on the body;
  • Keep it out of the reach of infants, children, and people without the ability to use it independently.
  • Don’t use another power adapter but the original one.
  • Don’t scratch, damage, process, excessively bend, pull, or twist the power cord of the power adapter. Otherwise, it may cause fire or electric shock.
  • It is not allowed to be used when the power adapter dysfunctions or the plug is loose.
  • Don’t plug or unplug the power adapter with wet hands.
  • Don’t put the control unit in the quilt or use the machine in high-temperature conditions.
  • It is forbidden to remodel, disassemble, or repair the machine without permission.

Cautions

  1. Only use the power supply provided by the system. Using a different power supply may cause the system to operate incorrectly.
  2. Don’t use it in the bathroom or other humid places.
  3. Keep it out of the reach of children.
  4. Unplug the power adapter when you are not using it.
  5. Don’t walk around when you are using this device or wearing the sleeves.
  6. Do not leave the system, power supply, or any accessories where they could be damaged by children, pets, pests, or liquids.
  7. The attachments are designed to be used by only one person at a time.

FAQs

  • 01; How does this product work?
    A 1: This is an air compression device, with 4 air chambers(foot, lower calf, upper calf, and thigh) inflated and deflated with a sophisticated sequence to stimulate hand kneading and stroking, maximize blood flow throughout the body to help with reduced muscle soreness and/or pains to the treated areas, and improve circulation.

  • 02: How many massage modes, and what’s the difference?
    A2: There are 3 massage modes, please check the difference below:

    • Mode1: Sequence Mode

    • Mode 2: Circulation Mode

    • Mode 3: Combination Mode

  • Q3: What should I do if I feel the massage strength is too weak or too strong?
    A3: There are 8 levels of massage intensity available, please select the intensity that is fit for you. If you still feel it’s too strong at the lowest setting, please stop using the device, we suggest to consult your doctor before your next use.

  • Q4: How long should I use it?
    A4: It is recommended to use it once or twice a day, no more than 30 minutes at a time. But you can use it longer if you feel too tired and want it to be massaged longer to work on the soreness.
    05: Can I only apply on one leg?
    A5: Both sleeves need to be connected to make it work, you can wear one of the sleeves on the desired leg and let another sleeve lay aside which will also be inflated/deflated at the same time even with nothing inside. We suggest to
    use both sleeves at the same time to get better relief.
    Q6: Why does the control unit make sound?
    A6: The sound comes from the working air pump in the control unit, providing air continuously to the airbags in the sleeves, it’s a low sound and that’s a normal phenomenon.

  • Q7: When should I use this product?
    A7: This product pushes the blood to flow and effectively removes muscle soreness and fatigue, you can use it anytime you want. You can use it before a workout to warm up your muscles, use it after exercise for better and faster recovery, or use it when you are back home after a long day of work.

Specifications

Troubleshooting

QUINEAR-QN-071A-Air-Compression-Leg-Recovery-System-fig-
\(5\)

You’re welcome to reach us at [email protected] if further assistance is needed.

Product Description

Control Unit

Display Screen
Display current setting and working status (remaining time and pressure range)

  1. Current Mode
  2. Current Strength
  3. Current Pressure
  4. Remaining Time
  5. Compressing Chamber

Massage Sleeve

  1. Sleeve Hose Connector
  2. Foot Air Chamber
  3. Lower Calf Chamber
  4. Upper Calf Chamber
  5. Thigh Chamber
  6. Zipper
  7. D Buckle: hang sleeve or assist in wearing

Air Hose

  1. Junction Box for Sleeves’ Hoses
  2. Connector to the Control UnitQUINEAR-QN-071A-Air-Compression-Leg-Recovery-System-fig- \(8\)

Adapter

Operating Instructions

Please read safety precautions carefully before using the product. In order to get a better massage, please use it according to the instructions.

  1. Inserting the sleeve hose connectors firmly to the hose.

  2. Connect the hose to the control unit, you will hear an audible ‘click’.

    • Two sleeves need to be connected to make it work.
  3. Connect the adapter well with the outlet and the control unit, there will be a ‘Di’sound and the screen will flash display for 1 second.

  4. Put the sleeves on your leg properly. Tips:

    • Please make sure the zipper is zipped up completely before wearing, never try to use the system with the zipper partially or totally unzipped
    • You can use the D Buckle on top of the sleeve to assist with putting it on quickly.
  5. Find a comfortable position sitting, reclined, or lying down. Press the power button to start.

  6. There is a ‘Di’ sound, the screen will light up and display the current setting

  7. It will begin with a default setting of Mode 1(Sequence Mode), Min Intensity (the lowest), 20-minute timing

  8. Press the mode button to change the massage mode. 3 modes are optional, see the difference in FAQS A2 session.

  9. Press the intensity button to adjust air pressure intensity, 8 levels are available.

    • We suggest you start with low intensity for the first use, and gradually increase after you get used to it.
  10. Press the time button to change between 3 treatment session times, 20 mins, 25 mins, or 30 mins. The time can be adjusted anytime while the session is running.

  11. The device will automatically shut off after the treatment time is up, you can press the button if you wanna enjoy more or end the massage earlier at any time.

Notes After Use

  1. If you are done using the device, turn off the control unit by pressing the power button, and disconnect the adapter from the control unit and the outlet.
  2. Disconnect the hose from the control unit by pressing the button on top of it and pulling away.
  3. Disconnect the sleeves from the hose, and remove them from your legs.
  4. Pack all the accessories into the original package or into the storage bag.QUINEAR-QN-071A-Air-Compression-Leg-Recovery-System-fig- \(21\)

Cleaning

Make sure to cut off the power before you clean the device.

  1. If dirty, please wipe the control unit, sleeves, and hoses with a damp, clean cloth.
  2. Dry thoroughly with a clean cloth.
  3. Don’t use gasoline, alcohol, diluent, or other irritating liquids to wipe the machine in case it causes malfunction or the components are damaged or discolored.
  4. Don’t allow foreign matters to enter the hoses.
  5. Don’t dry clean.

Storage & Maintenance

  1. Don’t disassemble the device by yourself. It has no user-serviceable parts. When service or repairs are required, please contact customer service at [email protected].
  2. Keep it out of the reach of infants, children, and people without the ability to use it independently.
  3. Don’t place it in high temperature and humidity conditions.
  4. Avoid direct sunlight.
  5. Avoid needles puncturing the sleeves and hoses.
  6. Don’t place heavy stuff on it.
  7. Keep the open ports of the control unit, hose interconnect, and power inlet free of debris.
  8. Do not allow lint or dust to accumulate on the control unit or the hose interconnects. If lint or dust accumulates, wipe down the system with a dry cloth before use.

Disposal
Please adhere to the local regulations when you dispose of the waste.

Package includes

  • 2 x Massage Sleeves(with hoses attached)
  • 1 x Control Unit
  • 1 × Air Hose Connector
  • 1 x Power Adapter/ AC100-240 V, 50/60Hz; DC12V1A
  • 1 x User Manual
  • 1 × Portable Storage Bag

Contact Us

  • If you have any problems during use, please feel free to contact our after-sales support team at any time.
  • E-mail: [email protected].
  • Note: Please tell us your order number along with the problems you meet in the email. Pictures or videos are welcomed for faster and better service.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

QUINEAR User Manuals

Related Manuals