LUMATEK 30W UV Supplemental Light LED Bar Instruction Manual
- June 9, 2024
- LUMATEK
Table of Contents
- LUMATEK 30W UV Supplemental Light LED Bar
- INTRODUCTION
- PRODUCT DESCRIPTION
- PRODUCT INFORMATION AND SPECIFICATIONS
- SAFETY RECOMMENDATIONS AND WARNINGS
- CONTENTS
- INSTALLATION
- INSPECTION, MAINTENANCE AND REPAIR
- STORAGE AND DISPOSAL
- WARRANTY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
LUMATEK 30W UV Supplemental Light LED Bar
INTRODUCTION
Thank you for purchasing the Lumatek 30W UV supplemental LED Light Bar. This manual describes how to install and use the light bar; please read this manual thoroughly before attempting to install or operate any Lumatek system. If you are not comfortable with the installation of high performance lighting systems, you should seek the services of a qualified installation professional.
PRODUCT DESCRIPTION
The Lumatek 30W UV supplemental LED Light Bar has been specifically designed
to augment Lumatek Zeus series full-spectrum LED grow light systems during the
plant’s flowering growth stage. Designed to fit directly on the Lumatek Zeus
LED fixtures, this unit has an independent power source and can also be
connected togeth-er in series with daisy-chain link cables.
Recent research shows strategic exposure of indoor-grown plants to UVA & UVB
light can increase secondary metabolite and essential oil production as well
as inhibiting mold, mildew & pest infestation, minimizing the need for
chemical intervention.
The 30W UV bar was specially designed to provide the ideal UV-B [280-315 nm]
and UV-A [315-400 nm] radia-tion doses to your plants based on scientific
support. A single fixture can provide 2.2 kJ/day (12 hours) of UV-B energy and
518 kJ/day (12 hours) of UV-A output. This translates to a fixture output of
100 mW of UV-B and 12000 mW UVA. Lumatek ensures that this fixture does not
produce UV-C radiation.
Daisy-chain link cable will allow you to easily connect several fixtures
together in series. To ensure unit perfor-mance, this LED bar has a single
input and output socket for the Power Cable or Daisy Chain link Cable,
depending on the use of that bar. For this reason, the Power (4m) and Daisy
Chain (1.5m) cables are sold separately.
PRODUCT INFORMATION AND SPECIFICATIONS
General Product Information
- PRODUCT NAME 30W UV supplemental LED Light Bar
- PRODUCT CODE LUMLED013
- MANUFACTURER Lumatek Ltd
- EAN 5060560031611
- PLUG TYPE UK/EU
Technical Specifications
- UV-A (315-400NM) 12000 MW
- UV-B (280-315NM) 100 MW
- INPUT VOLTAGE 220-240V AC 50-60HZ
- DRIVER 30W, 220-240V AC 50-60HZ INTEGRATED
- INPUT POWER 30W (+/- 5%)
- FOOTPRINT 1.2 X 0.6 M
- WATERPROOF/DUSTPROOF IP65
- LIFE SPAN L90 > 8500 HRS
- LIGHT DISTRIBUTION 140º
- LIGHT SOURCE UVA & UVB LED
- DIMENSIONS 1000 X 48 X 42 MM
- WEIGHT 1.2KG
- THERMAL MANAGEMENT PASSIVE HEAT SINK
- POWER FACTOR 0.98
- MAX AMBIENT TEMPERATURE 25ºC
- WORKING TEMPERATURE -10º — +40ºC
- WORKING HUMIDITY 20% – 90% NON-CONDENSING
- DIMMABLE NO
- DAISY-CHAIN CAPABILITY YES (MAX 30 PCS)
Fixture Dimensions
Spectral Quantum Distribution Graph
The 30W UV bar has been developed for use with Lumatek Zeus full spectrum LED fixtures. It is recommended to use two UV bars to supplement each fixture .
Light distribution curve
Environment
The LED fixture is intended to be used in climate-controlled grow rooms and
indoor farms.
The product may be used in damp environments but may not be used in wet
environments or outdoors. The product will operate in ambient temperatures
from -10ºC to 40ºC but will function at optimal level between 20ºC to 30ºC.
The product will operate in 20% – 90% humidity, non-condensing.
Legal
This product is CE & UKCA certified compliant with LVD and EMC directive
test standards.
SAFETY RECOMMENDATIONS AND WARNINGS
Warning! Carefully read the warnings below before using or working with the
product!
The LUMATEK 30W UV Supplemental LED light Bar produces UVB (near UV Erythemal)
and UVA (near UV-black light) electromagnetic radiation with wavelengths from
280 to 400 nm.
To avoid any biological affects in physical human body, please switch the
power off when installing and/or during the maintenance processes on your grow
system.
If turning Off UV Bars won’t be possible, all exposed skin should be covered
with opaque material including face, neck, head, hands, and arms. It is
assumed that other body parts are covered if wearing proper labora-tory
attire; long pants, closed toe shoes, gloves, long sleeve lab coats and
protective glasses.
Do not look directly at the light as the UVB radiation from the light fixture
can damage eyes and skin.
Do not restrict the airflow across the fixtures to avoid any heat build-up
which may reduce drastically the lifetime of your UV supplemental LED bars.
Do not put the UV Supplemental LED Bar in contact with any surface while still
ON.
Only use on plants.
-
CAUTION! Ultraviolet Radiation (UV)
-
Do not look directly into the UV light during operation
-
Wear protective eyewear to avoid exposure to UV light
-
Avoid direct skin & eye exposure to UV light
-
Keep out of reach of children
-
Do not open or disassemble the LED fixture as it contains no serviceable parts inside. Opening or modifying the LED fixture can be dangerous and will void the warranty.
-
Do not use the LED fixture when either the LED fixture or its power cable are damaged. Replace the power cable with correctly rated cable only.
-
Modifications to the cables can lead to unwanted electromagnetic effects which may make the product not comply with legal requirements.
-
Do not expose the LED fixture to:
Condensing humidity, heavy mist or direct spray;
Ambient temperatures outside the specified range;
Dust and contamination;
Direct sunlight during use or HID light that may heat up the driver. -
Always disconnect the LED fixture from mains before performing any maintenance.
-
Always allow for a cool down period of at least 20-30 minutes before touching the LED fixture. Touching the LED fixture when the fixture is lit or immediately after may result in burns!
-
Natural convection removes heat away from the heatsink. In order for the system too properly cool itself, at least 5cm of space is required between the fixture and the roof of your grow area.
-
Do not use abrasive materials or aggressive cleaning agents to clean the LED fixture as this may damage the secondary optics. Instead use a clean damp or dry fabric/cloth.
-
Do not use the LED fixture near flammable, explosive or reactive substances. The LED fixture can reach temperatures of 40ºC.
-
Do not use sulphur vaporizers or water misters.
-
The installation and use of the LED fixture is the responsibility of the end user. Incorrect use or installation can lead to failure and damage to the LED fixture. Damage to the LED fixture and electronic circuitry as a result of incorrect installation and use revokes the warranty.
CONTENTS
1 X MANUAL
[PLS NOTE:
POWER & DAISY-CHAIN CABLES ARE SOLD SEPARATELY]
INSTALLATION
- Warning! Mounting and installing the LED fixture must be in accordance with the applicable local laws and regulations.
- Warning! The installer is responsible for correct and safe installation.
- Warning! Ensure the local cabling can support the voltage and current requirements of the LED fixture.
- Warning! Avoid coiled cables and keep mains leads separated to help prevent electromagnetic interference.
- Warning! Do not connect or disconnect the LED fixture under load.
Fixture assembly & installation
WARNING! The light bar is shipped with a protective plastic cover over the diodes. Please ensure this protective cover is removed before use !
Recommended Coverage
The Lumatek 30W UV Supplemental LED Bar was designed to fit directly into the
Zeus fixtures. To make sure you achieve the best light spread over the canopy,
we recommend: Integrate a minimum of 2 units of 30W UV Supplemental Light LED
Bar, with:
-
ZEUS 465W 2.6 – 1.2 x 1.2 m footprint
-
ZEUS 600W 2.6 – 1.4 x 1.4 m footprint
-
ZEUS 465W PRO 2.9 – 1.2 x 1.2 m footprint
-
ZEUS 600W PRO 2.9 – 1.4 x 1.4 m footprint
-
ZEUS 1000W Xtreme CO2 – 1.5 x 1.5 m footprint w/ CO2 Supplement
Integrate a minimum 3 units of 30W UV Supplemental Light LED Bar, with: -
ZEUS 1000W PRO – 2.0 x 1.5 m footprint
Recommended UV-B + UV-A Radiation Application
Always mix the supplemental UVB + UVA radiation with the Lumatek Zeus Full
Spectrum LED Range.
The UV bars have been designed for 12 hours operation to match the flowering
photoperiod and can be switched ON/OFF at the same time as the Zeus full-
spectrum fixture.
UV strategic exposure to flowering plants can begin from 4 weeks before
harvest and particularly the last 2-3 weeks of bloom when flower and resin
development is most present.
For a good UV radiation spread, ensure to install the recommended minimum
units and follow the distance to canopy referred on the Grow Light Strategies
table, download from: https://lumatek-lighting.com/education/
If you notice plant damage, we recommend to increase the distance between
fixture and canopy or decrease the UV light output delivered to your plants by
reducing the UV photoperiodic time.
Connecting the UV bar to the mains power
- Warning! Make sure mains power is switched off.
- Warning! Ensure the power supply cable is not coiled and does not touch any hot surfaces.
- Warning! Connect the cables according to local rules, safety regulations and electrical code.
- Warning! Do not connect or disconnect the LED fixture under load.
The Lumatek UV LED bar power cable (4m) and the UV LED bar daisy chain cable (1.5m) are both sold sepa-rately.
The power cable should be connected to the UV bar power input port;
Remove dust cap from UV bar Input connector.
Correctly align connectors and push together until ‘click-locked’.
Connect mains power plug to switching gear/power supply.
Switch on mains power.
To disconnect;
Switch OFF mains power
turn power cable connector twist-lock anti-clockwise and pull apart from bar connector port.
Connecting UV bars together in series with daisy chain cables
A UV bar power cable is required to power the first UV bar and then further UV
bars can be connected in series from the first bar and powered with the UV
daisy chain cables.
Maximum 30pcs UV bar can be daisy-chained from one power source.
Ensure mains power is OFF
Using the Lumatek UV daisy chain cable; connect UV bar [1] power output port
to UV bar [2] power input port by correctly aligning connectors and push
together until ‘click-locked’.
Continue until all UV bars are connected.
Switch on mains power.
To disconnect;
Switch OFF mains power
Turn daisy chain cable connector twist-lock anti-clockwise and pull apart from
bar connector port.
Warning! Do not connect or disconnect the UV bars under load.
INSPECTION, MAINTENANCE AND REPAIR
- Warning! Disconnect the LED fixture from mains before performing any maintenance or repairs.
- Warning! Do not connect or disconnect the LED fixture under load.
- Warning! Do not open or disassemble the LED fixture, it contains no serviceable parts inside. Opening the LED fixture can be dangerous and will void the warranty.
- Warning! Always wait 20 – 30 minutes for the LED light bars to cool down before handling.
- Caution! Do not clean the LED fixture with detergents, abrasives or other aggressive substances.
Regularly check the LED fixture for dust or dirt build up. Clean if necessary. Contamination may cause overheating and decreased performance.
Clean the outside of the LED fixture using a dry or damp cloth.
Regularly check the cables of the LED fixture to ensure it is undamaged.
STORAGE AND DISPOSAL
Store the LED fixture in a dry and clean environment, with an ambient
temperature of -25ºC to 55ºC.
The product must not be discarded as unsorted municipal waste but must be
collected separately for the purpose of treatment, recovery and
environmentally sound disposal.
WARRANTY
Lumatek warrants the mechanical and electronic components of their product to be free of defects in materi-al and workmanship if used under normal operating conditions for a period of one (1) year from the original date of purchase. If the product shows any defects within this period and that defect is not due to user error or improper use Lumatek shall, at its discretion, either replace or repair the product using suitable new or recondi-tioned products or parts. In case Lumatek decides to replace the entire product, this limited warranty shall apply to the replacement product for the remaining initial warranty period, i.e. one (1) year from the date of purchase of the original product. For service; return the product to your shop with the original sales receipt.
info@lumatek-lighting.com
www.lumatek-lighting.com
References
- Sustainable LED lighting solutions | Philips lighting
- LUMATEK Professional Grow Lighting | Ballasts | Lamps | Reflectors
- Lumatek Education | Know all about lighting grow, growing plants and more
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>