Osaki EC-806R Massage Chair Instruction Manual

June 5, 2024
Osaki

EC-806R Massage Chair
Instruction Manual

IMPORTANT SAFETY INSTRUCTIONS

These safety instructions must be strictly followed in use to avoid personal injuries and property damage:
All the safety instructions are described in compliance with the degrees of the injuries or damage as a result of wrong use.
Warning: Actions leading to cause serious injuries or death
  Caution: Actions leading to cause minor injuries or property damage
■ Pay attention to the symbols before safety instructions (an example is given below).
Actions that must be absolutely forbidden
Actions that must be done

Warning

Mast be followed|

■  IMPORTANT SAFETY INSTRUCTIONS
When using an electrical appliance, basic precautions should always be followed, including the following: Read all instructions before using (this appliance).

---|---
■  DANGER-To reduces the risk of electric shock:
•  Always unplug this appliance from the electrical outlet immediately after using and before cleaning.
•  Never use pins or other metallic fasteners with this appliance.
•  Carefully examine the covering before each use. Discard the appliance if the covering shows any sign of deterioration, such as checking, blistering, or cracking.
•  Keep Dry-Do not operate in a wet or moist condition.
WARNING-To reduces the risks of burns, fire, electric shock, or injury to persons:
•  An appliance should never be left unattended when plugged in. Unplug from outlet when not in use and before putting on or taking off parts.
•  Close supervision is necessary when this appliance is used by, on, or near children, invalids, or disabled persons.
•  Use this appliance only for its intended use as described in this manual. Do not use attachments not recommended by the manufacturer.
•  Never operate this appliance if it has a damaged cord or plug, if it is not working properly if it has been dropped, damaged, or dropped into water. Return the appliance to a service center for examination and repair.
•  Do not carry this appliance by supply cord or using the cord as a handle.
•  Keep the cord away from heated surfaces.
•  Never operate the appliance with the air openings blocked. Keep the air openings free of lint, hair, and the like.
•  Never drop or insert any object into any opening.
•  Do not use outdoors.
•  Do not operate where aerosol (spray) products are being used or where oxygen is being administered.
•  To disconnect, turn all controls to the off position then remove the plug from the outlet.
•  Keep children away from extended foot support.
•  Connect this appliance to a properly grounded outlet only. See Grounding Instructions.
•  Use heated surfaces carefully. May cause serious burns. Do not use over insensitive skin areas or in the presence of poor circulation. The unattended use of heat by children or incapacitated persons may be dangerous.
•  Do not operate under a blanket or pillow. Excessive heating can occur and cause fire, electric shock, or injury to persons. SAVE THESE INSTRUCTIONS

■ Persons with the following conditions or under these medical treatments should consult a physician before using this appliance.

Warning

Mast be followed|

  1. Persons with a pacemaker cannot use this product. The chair may cause an electronic malfunction to the medical device;

  2. Patients with malignant tumors;

  3. Patients with heart disease;

  4. Persons unable to feel or insensitive to heat on their skin such as a diabetic patient;

  5. Pregnant women or ones that have just given birth;

  6. Persons with poor blood circulation such as a diabetic patients;

  7. Osteoporosis patients, spinal fracture patients, or persons with acute painful disease or injuries such as joint sprains or muscle strains;

  8. Persons with any injuries should not use this appliance;

  9. Persons with higher or lower body temperature, fever, inflammation, cold symptoms, high blood pressure, or any poor health conditions should consult a physician before using this product;

  10. Avoid falling asleep in this chair; Anyone with spinal or nerve conditions; Persons with protrusion of intervertebral disc;

  11. Do not wear loose clothing or jewelry as it might get caught with the massage mechanism;

  12. Keep long hair away from the moving massage mechanism while in use.

Otherwise, discomfort or even physical injuries may occur.

---|---
If you feel unwell while using or after using the chair, stop immediately and contact your physician.
Do not use the chair again unless approved by your doctor.

Before operating or adjusting the chair, be sure that there are no obstructions that can cause
damage to your chair. No pets or persons, near, in front, or under the chair to avoid serious injury.

Before using the chair, lift up the backrest pad and check the middle cover area where the massage rollers travel up and down. Be sure the middle nylon cover is not unzipped and has no signs of damage or tear caused by the roller heads. Using the chair while the roller heads are exposed could cause physical injury and electrical shock.
When using the chair for the first time, it is recommended that you select the “Demo” mode to get familiar with various massage features of the chair.
Do not use the chair for more than 30 minutes each time.
Do not massage a single part of your body for more than 5 minutes.
Failing to follow these instructions, discomfort or even physical injuries may occur.
After using the chair, it is recommended that the chair is unplugged from the power outlet to avoid
any surges caused by outages. It is HIGHLY ADVISABLE TO ALWAYS USE A SURGE PROTECTOR.
Keep children or minors from using the chair without supervision to avoid misuse that could result in serious injuries.

Follow the local code and regulations about the use of electrical products.
Use a 110V-120V, 60Hz power supply.
(Do not use the chair in a country this product is not designed for or connect it with a transformer.)
It may lead to electrical shock, product failure, or internal components overheating causing a fire
hazard.

Make sure the power cable is firmly plugged into the outlet to avoid power surges and short and electrical shocks. Electrical shocks may cause internal components to overheat causing fire hazards.
Wipe and clean the power plug regularly with a dry cloth to avoid dirt or moisture building up.
Mast be followed| In the case of any abnormality with the functions of the chair, stop using the chair immediately and pull out the power plug to avoid smoke, fires, and electric shocks.
Abnormality and fault examples
If the chair is plugged in and the power switch is in the “ON” position and if the chair is not responding.
When the chair is turned off but still operating.
If you detect any burning smell or abnormal sounds.
If you detect any parts of the upholstery that seemed to have melted due to overheating.
→In any of these listed issues have occurred STOP using the product and unplug from the power outlet. Have the product inspected by an authorized service center.
Forbidden| Do not put any cushions or obstructions between the backrest pad and the backrest. This may
damage the mechanism and result in personal injury.

When moving or handling the chair, be sure to hold onto the recommended supported area. Otherwise, parts of the chair may break resulting in serious injury.

Warning

Forbidden

|

■  People with the following health issues should NOT use this chair:
Persons for whom massage is not advisable by doctors. Such as persons with thrombosis, serious aneurysms, acute venous aneurysms, various skin inflammations (such as subcutaneous tissue inflammation), or various skin infections. Otherwise, it may aggravate or cause serious injury.

---|---
■ Anyone with physical injuries or poor health should NOT use this product.
Persons with acute lumbago, protrusion of intervertebral disc, or displacement of a lumbar vertebra.
Otherwise, it may aggravate or cause serious injury.
■ Do not put hands, arms, or feet into the traveling massage mechanism while the chair is operating.
■ Keep small children away from the chair. Climbing could result in falls that could lead to serious injuries.
■ Do not climb onto the backrest or the armrests.
■ Do not apply excessive pressure leaning back on the backrest.
■ Keep your head away from reachable areas of the backrest and the back cover.
■ Young persons or persons with physical disabilities that can not operate the chair on their own, should not use this product without supervision. Anyone with weak physical conditions should consult a doctor before using the chair.
■ When massaging the neck area, pay attention to the intensity of the massage and make sure it does not hurt the neck muscles or nerves.
■ Do not damage the power cord.
Do not damage, alter, bend, twist or use it with any extension cords. Do not place the power cord close to a heater.
A damaged power cord may result in electric shocks, short circuits, or fires.
Please consult with the retailer/dealer from which you bought the product or a designated authorized service center
about maintaining your power cord.

■ When engaging the heat function of massage wheels, avoid prolonged contact with the skin in one position. Otherwise, low-heat burns may occur.
Even if the temperature is relatively lower at 40~60, low- heat burns may happen in spite of no obvious hot or painful sensation.

Wet-hand operation forbidden

| ■ Do not insert or pull out the power plug when your hands are wet. Otherwise, electric shocks may happen.
Disassembly Forbidden|

■ Do not refit, disassemble or repair the product without the help of an authorized service provider.
Otherwise, fires, abnormal movements, or personal injuries may happen.

  Caution

Mast be followed| ■ The following persons (even if they are physically healthy at present) should consult a physician before using the product.
(1) Persons with muscular atrophy due to old age or below normal weight;
(2) Persons feeling lumbago with pain in the muscles and joints of the lower back;
(3) Persons suffering from sprains or bruising easily;
(4) Persons with motion sickness;
(5) Persons who received a heart operation or another vascular operation. It may cause serious injury if not addressed properly.
Otherwise, it may aggravate or cause serious injury.
■ Before sitting on the product, make sure there are no foreign objects between any two parts of the chair.
(Make sure there are no foreign objects on the back cover, the backrest, the seat surface, the lower leg/foot massage section, or the inside surface of the back cushion.)
Otherwise, accidents, injuries, or product faults caused by clamping of hands, feet, or other articles may occur.
Before sitting on the seat, make sure the massage wheels are in the retracted positions.
■  Turn off the massage function before you get off the chair.
When the lower leg/foot massage section is not retracting after the massage, retract the footrest with the remote button.
When unplugging the chair, always hold onto the plug and not the cord to avoid damaging the power cord. A damaged cord could result in shock and serious injuries.
■ Before moving the chair, be sure the backrest is up and the footrest is retracted in default positions.
Otherwise, injuries may happen.
■ When moving the product by dolly, lay mats on the floor to avoid markings or damage to the floor. Do not roll the chair on engineered wood or softwood floorings. Otherwise, marks and damage may occur.
■ Keep the safety lock key.
■ Keep children away from the remote control.
■ Before moving the chair, make sure there are no obstructions around. If lifting is required, make sure to lift from the steel frame of the chair. Be sure to maintain good balance or the heavy chair could tip and fall on the movers, causing serious injuries.
■ Symptoms such as skin inflammation, itching, or swelling when using the chair, stop using the product immediately, and consult a physician.
Forbidden| ■ Do not use the product with other electrical devices at the same time, such as a heating blanket.
■ Do not place your hands, arms, feet, or any parts of your body to massage areas that are not designed for the body parts to avoid discomfort or injuries. Do not put the knees between the calf massager. This may cause serious injury.
■ Do not fall asleep while using the product. Do not use the product after drinking alcohol.
■ If the airbag on the seat is not completely deflated, do not stand or jump on the seat or put things on it. It could risk puncture.

  Caution

Forbidden

|

Do not put hands or feet between the footrest and seat base. Do not put hands or feet between the footrest and side panel. Do not put hands or feet between the seat base and side panel.
Do not put hands or feet between the upper and the lower part of the footrest. Do not put hands or feet in the gap of the seat base.
Do not put pets on the massage chair.
Do not pull out the power plug or turn off the power switch suddenly during massage operation.

---|---
Do not stand or sit on the back cover. The chair may topple.
Do not stand or sit on the armrests.
Do not stand or sit on the lower leg/foot massage section or the footrest.
Do not drag or push the product after it is installed.
Do not move the product while there is a person sitting on it.
Do not use the product with other heating devices such as electric blankets. Otherwise, fires may occur due to overheating.
Do not leave the remote controller on the seat, always return it to its holder.
If there is any foreign objects between the backrest and the backrest pad, stop using the chair and turn it off. Remove the foreign object and make sure the chair is operating properly before using it again.

Wet-hand operation forbidden

| Do not place this chair in locations with high humidity such as the bathroom. Moisture will destroy electrical components resulting in product failure or worst, electrical shock and other serious injuries.
Product wetting forbidden| Do not use any liquid aerosol sprays around the chair. Otherwise, electric shocks, short circuits,s or product failure may happen.
Pull out the power plug| Before cleaning or maintaining the product, always unplug the power cord.

In the case of a power failure, pull out the power plug at once. It is highly recommended to plug the chair into a surge protector to protect the chair from shorting during outages.
■ When the product is not in use, pull out the power plug.

GROUNDING INSTRUCTIONS
This product must be grounded. If it should malfunction or break down, grounding provides a path of least resistance for the electric current to reduce the risk of electric shock. This product is equipped with a cord with an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. Danger-Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or serviceman if you are in doubt as to whether the product is properly grounded. Do not modify the plug provided with the product – if it will not fit the outlet, have a proper outlet installed by a qualified electrician.

Product parts

Air Bags Massage Position

Before use

1. Before use (installation position)

  • Make sure there is enough space to recline the chair and for the user to get in and out of the chair freely. PLEASE MAKE SURE TO USE A MAT OR RUG UNDER THE CHAIR IF YOU PLACE THE CHAIR ON TOP OF A HARD SURFACE LIKE HARWOOD AND CERAMIC FLOORS.
  • Do not expose the product directly under the sunlight or in a high-temperature place (e.g., in front of heating equipment or by a window where sunlight can cause the synthetic leather to fade to melt or crack )
  • Place a mat below the product to avoid floor damage. The mat should cover the product’s area in contact with the floor and the footrest’s area in contact with the floor (minimum dimensions: 63″x31.5″). See the figure.
  • Install the product close to a power socket.

2. Check the space around the product.
Make sure there is no person, pet, or other object close to the product. 

3. Make sure there are no foreign 0 objects in the seams of the product.

Caution

  • Do not put hands or feet between the footrest and seat base.
  • Do not put hands or feet between the footrest and side panel.
  • Do not put hands or feet between the seat base and side panel.
  • Do not put hands or feet between the upper and lower parts of the footrest.
  • Do not put hands or feet in the gap of the seat base.
    otherwise, injuries may happen.

4. Inspect the power line and power plug

Do not be entangled by the power line.
Make sure the plug is fully inserted.
Warning

  • Inspect the power cord of dirt or dust that may have collected. Be sure the cord is kept clean and with NO visible damage.
    Otherwise, the lint and dust may lead to an electrical fire. Wipe down the plug with a dry cloth.

  • Do not damage the power line or the power plug.
    Do not bend or twist the power cord for any reason.
    Do not place the power cable under heavy objects such as the chair Itself. Keep the power cord away from any heating sources such as the heater vents, motors, and anything that may generate heat.
    A damaged power line or power plug may result in electric shocks, short circuits, or fires. Please consult the shop you bought the product or an authorized service center about the maintenance method of the power line or the power plug.

5. Power on the product

  1. Insert the power plug into the power socket.
  2. Turn the switch to the “I” (ON) position to activate the chair.

Warning

  • Be sure the power cord is firmly and completely inserted into the power outlet
    Otherwise, electrical shocks or fires may occur because of overheating or power shorts.

  • Abide by the regulations on the use of the socket and the wiring devices strictly.

  • Use a 110-120V-, 50160Hz power supply. (Do not use the product in a foreign country or connect it with a transformer without permission.)
    Otherwise, electric shocks, product faults, or fires because of overheating may happen.

  • Do not insert or pull out the power plug with wet hands.
    Otherwise, an electric shock may happen.

6. Make sure the massage wheels are retracted If the rollers die not at the top of the backrest in the retracted position, press the “ON” button to bring it back to the default position.

7. Make sure the fabric is not damaged nor cracked
Inspect the synthetic leather portion in which the massaging rollers travel along with the backrest. Be sure there is no damage or unusual wear.

Warning

  • Before use, raise the back cushion and check whether the fabric lining pointed out in the figure is undamaged.
    ( Even if the fabric is slightly damaged, stop using the product immediately. Pull out the power plug and send notify the manufacturer for a replacement cover.)
    If the product is used when there is fabric damage, you may get injured or get an electric shock.

The controller instructions

Power switch on top of the controller 1. Power switch on the top of the controller

  • ON /OFF button
  • Press this button to start the massage chair. Touch any massage function massage.
  • Press this button again to turn off the massage chair, and it will return to its original position.
    icon to start

2. Touch screen

  • There are 8 function options on the touch screen for users to select.
  • The setting is in the top left corner.
  • Pause is on the top right corner.

Operation guide

1. Manual

  • Touch this icon, the screen will turn to the [Manual] page.
  • There are 4 different massage programs for the parts of the back area.
  • Users can select and start the program they prefer.
  • Kneading/Tapping/Shiatsu has two kinds of massage techniques for selection.

NOTE:
(1) 4D Mechanism:

  • There are 7 adjustable levels for the 4D mechanism intensity.
  • In massage mode, the mechanism intensity will be set to default.

(2) Intensity/ Strength/ Speed:

  • There are 5 different levels for adjustment.

(3) Upward/ Downward icon:

  • When pressing the [Spot] button, it will stop the massage rollers from moving up or down and the massage rollers will stay at that point.
  • In order to change the spot location of the massage rollers, just press the up or down icon and stay at the position that prefers.

(4) Width:

  • The width of the massage can be adjusted for tapping, shiatsu, and rolling.
  • Press the left and right arrow icons.

(5) Spot:

  • The spot massage allows users to select a spot for any part of the back area.
  • Touch the icon a time to activate spot massage at the spot that prefers.
  • Touch the icon again to stop the function.

(6) Partial:

  • The partial message allows users to select a region(1/4 of the back).
  • Touch the icon a time to activate the partial massage.
  • Touch the icon again to stop the function.

2. Advanced

  • When pressing [ Advanced ], the screen will change to the according page.
  • There are 4 programs to select from.
  • Users can select and start the program that prefers.

NOTE:

  • Heating:
    The heated rollers will activate in the auto program. Touch this icon to turn off the heating from the rollers. Touch again to turn it on.

  • Calf kneading:
    When selecting this program, you can control the speed of the calf kneading.

  • Foot kneading:
    The footrest is equipped to knead(rollers) and compress(mechanical).